Air Bear Right Angle. Media Air Cleaner READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

Similar documents
Air Bear Supreme and Air Bear Cub. Media Air Cleaners READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE. TRION

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

Complete Whole House Air Cleaning System Photronic Base Media Air Cleaner OWNERS GUIDE

READ AND SAVE THESE INSTRUCTIONS. Air Boss MP600M Vertical Air Flow Mist Precipitator Industrial Applications. TRION

INSTALLATION, OPERATION, AND MAINTENANCE INSTRUCTIONS. Part Number: P DM

Air Boss Model M3000. Industrial Air Cleaner READ AND SAVE THESE INSTRUCTIONS. TRION

CA3000C & CA6000C Cartridge Air Cleaners

WR Air Accessory Mounting Brackets

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Installation Manual for Ecology

Product Data. FILCAB, FILCAR & EZ Flex Efficient Mechanical Air Cleaner. Sizes 016, 020, 024. FILCAB Filter Cabinet. FILCAR Media Filter

INSTALLATION INSTRUCTIONS

RESPA -SD or Gideon HVAC Fresh Air Filtration System Installation Guidelines for John Deere 450J, 550J, 650J, 700J, 750J, 850J Crawlers

Product Data. Filter Cabinet (FILCAB) Cartridge Filter (FILCAR) EZ Flext (EXPXX) Sizes 16, 20, 24. Filter Cabinet (FILCAB) Cartridge Filter (FILCAR)

MULTI-STAGE FILTRATION SYSTEM INSTALLATION INSTRUCTIONS

HARDWARE KIT INSTALLATION GLOVES

IQAir Perfect 16 ID-Series MERV16 Micro-Particle Filtration System. Perfect 16. Installation Manual

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS SINGLE HORIZONTAL ACCESS DOOR PANTRY INSERT MANUAL

Further information: Berriman Associates Model 850P.2 Owners Manual

idrive Power Cord Extender Installation Instructions MODELS: 3960M/3961S (1) 25 POWER CORD DRILL WITH 3/32 DRILL BIT

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

Air Boss CA3000C & CA6000C. Installation Operation Maintenance Manual. Cartridge Air Cleaners

Tiller Lock Assembly

FILCAB, FILCAR & EZ Flex Sizes 016, 020, 024

Installation & Maintenance of the Fresh-Aire UV Airborne Duct System for Commercial HVAC Systems. Parts Included. Optional Parts

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

Product Data. FNCCAB & FILCCFNC High Efficiency Fan Coil Filtration. Sizes 014, 017, 021 & 024. FNCCAB Filter Cabinet. FILCCFNC Media Filter

VOLUMETRIC FILTER MODELS T450 T500 T600 T700 T600B T700B

Table of Contents. Technical Information Warning Statement

Installation Instructions

Nelsen Filtration Cartridge Systems

Air Boss M-Series Media & Adsorption Air Cleaner

Model 8144NC Fresh Air Ventilator

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

Installation Instructions

OWNER S MANUAL MODEL FSHEPA375 WHOLE-HOUSE TRUE HEPA AIR CLEANER IMPORTANT: PLEASE READ MANUAL BEFORE OPERATING UNIT

C.I.Agent HFF Oil Stop Valve

Air Curtain. Installation, Operating and Maintenance Instructions

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

MODEL FA1 Mini Air Filtration System. Operations Manual

Miracle State Of The Art Air Filtration System!

OPERATOR S MANUAL MODEL GC-STC-V

Warning Statement Read Before Riding

Cast Iron WARNING CAUTION. CAUTION Some parts may contain sharp edges especially as noted in manual. Wear protective gloves if necessary.

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

HSIV PLOW OPERATOR S MANUAL

Ride Rite Warranty Evaluation Guide

FLEETWOOD TRAVEL TRAILER SLIDEOUT SYSTEM OWNER S MANUAL

ROCK HARD 4X4 JEEP WRANGLER JK 2/4-DOOR L EVAP CANISTER RELOCATION KIT PART #: RH-6005-B Installation Manual

Installation Instructions

US Water Systems Magna Pre-Filter

FNCCAB and FILXXFNC High Efficiency Fan Coil Filtration Sizes 14, 17, 21 and 24. Product Data A FNCCAB Filter Cabinet

4101 / 4102 READ INSTALLATION INSTRUCTIONS IN ITS ENTIRETY BEFORE INSTALLING YOUR COIL-RITE KIT PARTS LIST OPERATING PRESSURES. Figure A DESCRIPTION

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

StormPro BA Series Sump Pump

HA/HAB Fiberglass Wall Mount Ventilators

"SPOAU" DEDICATED 100% OUTSIDE AIR UNITS Self Contained Single Package or Split System Units

FNCCAB & FILBBFNC Sizes 014, 017, 021 & 024

LIGHTSTICK / LIGHTSTICK PLUS Germicidal Ultraviolet Light

WARNING OPERATING PRESSURES: READ INSTALLATION INSTRUCTIONS COMPLETELY BEFORE INSTALLING YOUR KIT

VLF-797 CLEAN BENCH INSTALLATION AND SERVICE MANUAL Volt Model Volt Model

2-Pack Indoor/Outdoor Simulated Security Cameras. Owner s Manual

POWER GEAR SLIDE-OUT MANUAL

MPG526-L Kayak Stacker Instructions

21", 33", 45", & 61" Installation & Operation Manual

HR-20P Pneumatically Controlled Pressure Regulator

INSTALLATION GUIDE. Rainier Coil Pull Down Kitchen Faucet PB-K01

MODEL 950C-NP-UV Installation and Owners Manual

Model G14SD Vapor Management System

RANGE HOODS USER INSTRUCTIONS

Installation Instructions

Installation Instructions

PART NUMBER: F-706RLSS REVOLUTION LIFT: SLING-SEAT OPTION

STOP. LP-50DEF-BRL Lever Hand Pump System Barrel Mounting. Owner s Manual DO NOT RETURN THIS PRODUCT TO THE STORE! SAVE THESE INSTRUCTIONS

Tower Dryer. Wiring Diagrams Manual PNEG-554r09

Installation Instructions To ensure that your installation proceeds smoothly--please read these instructions carefully before you begin.

Installation manual 2 Leveling kit GM x 4. Part # Part # Important customer information: GM x 4

BCFS Belt Driven Centrifugal Filtered Supply Fans

US Patent 0540, 400 Other Patents Pending. Read this manual completely before assembling and riding our PET PRO-FLEX 500. Always wear a Helmet!

INSTALLATION GUIDE KPF Single Lever Kitchen Faucet With Pull-Out Sprayer

Installation & Operation Manual Chef Base

MODEL FIXED MOTOR BRACKET

INSTALLATION INSTRUCTIONS CARE AND MAINTENANCE

US Water ORP Booster Injection System

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

INSTALLATION MANUAL VAN SOLUTIONS FOR THE WAY YOU WORK. Models & E. Terra Cotta Ave Fax

HYDRAULIC LEVELING SYSTEMS OPERATIONS MANUAL (For systems with touch pad part number , , , , or no number at all)

QSI (Q-Star) Electronics Owner s Manual

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS

OPERATOR S MANUAL FABRIC 3-BAG GRASS CATCHER PART NO PRINTED 8/2012 PRINTED IN USA

BEAM Alliance central vacuum system. U.S. Price

Installation Instructions for Pressure Balancing Valve Set with Volume Control. Limited Lifetime Faucet Warranty

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Operating Manual PFB-2500

Installation Instructions

ipd Catback Oval Tube Exhaust System S60R ( ), V70R ( ) ipd #120056

Kitchen Tech Series Air Curtain

Transcription:

READ AND SAVE THESE INSTRUCTIONS UNITS NOT FOR COMMERCIAL USE Media Air Cleaner TRION www.trioniaq.com

Table of Contents Introduction... 1 Dimensions... 2 Installation... 3 Maintenance... 4 Warranty... 5

Introduction Your media air cleaner is a high efficiency air filtration device designed to remove dirt, dust, pollen, and other microscopic particles from the air passing through it. How It Works Dirty air enters the air cleaner by way of the return air duct system in your home. Particles are collected by the special pleated filter media. The pleats provide an exceptionally large filtering face area in a very compact space, which allows maximum dirt holding capacity with minimum air flow resistance. www.trioniaq.com 1

Specifications Dimensions Airflow Airflow 4 1/2 8 or 10 Adjustable 10 24 1/2 0.187 TYP 1 8 10 3/4 1/2 23 3/8 23 1/2 13 1/2 7 1/2 OPENING 1 1/4 15 1/2 25 5/8 2 Application The air cleaner is to be installed in a forced air heating, cooling, and ventilation system. It should be installed in the system such that all the system air is circulated through the air cleaner. Maximum performance is obtained when the system blower is set for continuous operation. 2 www.trioniaq.com

Installation Installation Requirements Locate the air cleaner in the return air duct next to the blower compartment. In this location, the blower motor and the cooling coils will be kept clean. Do not install the air cleaner in the discharge air duct. Do not install the air cleaner where it is directly exposed to UV Lighting. The unit must be readily accessible for periodic inspection and replacement of the filter cartridge to maintain maximum efficiency and trouble-free operation. A clean coil will reduce utility cost by maintaining the coil s efficiency. Failure to replace the filter cartridge can cause damage to the cooling system. Allow a minimum of 30 clearance in front of the access panel for filter cartridge replacement. TYPICAL INSTALLATION Air Cleaner Installation and Maintenance The right angle media air cleaner has been designed specifically for highboy furnaces with direct installation to the heating and cooling system return air duct. The duct opening of the air cleaner is supplied with an adjustable inlet flange. The unit is shipped with the flange set at 24 x 8. If the incoming duct is 24 x 8, attach the duct directly to the flange and secure with sheet metal screws through the pre-drilled holes. TRION S AIR BEAR RIGHT ANGLE INSTALLATION If the flange requires adjustment to 24 x 10, remove the five #6 sheet metal screws securing the flange to the cabinet. Adjust flange to 24 x 10 and secure with screws. Proceed with installation. AIR BEAR RIGHT ANGLE SPACE SAVER Smaller Footprint! Select Location for the Air Cleaner Select a location that is readily accessible for periodic inspection and cleaning. Allow a minimum of 30 in front of the access panel for filter removal. Direction of Airflow through the Air Cleaner Note: The air cleaner is designed for easy access from either side. Select the location and locate air cleaner opening next to furnace. Install the door handle on the front panel to allow easy access for filter cartridge removal. The direction arrow on the filter cartridge must point in the direction of air flow. Mounting holes are provided in the air cleaner cabinet for duct work attachment. The.187 holes are sized for #8 sheet metal screws or 1/8 rivets. www.trioniaq.com 3

Maintenance Maintenance The filter cartridge in the air cleaner must be replaced periodically. The frequency of filter replacement is best determined by visual examination. On average, MERV 11 filter cartridges should be replaced every 4-6 months of normal usage. Steps for Replacing Filter Cartridge 1. Open access door by lifting the handle and pulling the bottom of the door toward you. Remove door completely. 2. Tilt used filter cartridge to allow filter to be removed from cabinet. Pull used filter cartridge from cabinet. 3. Discard dirty filter cartridge in plastic bag in which replacement filter was received. 4. Slide new filter cartridge into cabinet with AIR FLOW arrow pointing in the direction of air flow. Care shall be exercised to place filter cartridge in angle holders on bottom and side of cabinet. 5. Replace access door. Note: Your installing dealer can supply media air cleaner replacement filter cartridges. Remember, periodic inspection and replacement of your filter will ensure high efficiency air cleaning with the frequency of filter replacement best determined by visual inspection. Model Supreme Supreme-HD MERV 8 MERV 11 MERV 13 MERV 8 MERV 11 MERV 13 Unit Part No. (British White) 447380-010 447380-510 447380-0010 266380-010 266380-510 266380-0010 Unit Part No. (Warm Grey) 447380-011 447380-511 Not Available 266380-011 266380-511 Not Available Media Part No. (3 Pack) 255649-102 259112-102 266649-102 255649-102 259112-102 266649-102 Media Size 5 D x 20 H x 24 1/2 W 4 www.trioniaq.com

Warranty MEDIA AIR CLEANER LIMITED LIFETIME WARRANTY This limited warranty covers TRION residential type media air cleaners, excluding door latch, disposable media cartridge, charcoal filter, accessories, ductwork, and installation. TRION warrants that all new TRION media residential air cleaners are free from defects in material and workmanship under normal, noncommercial use and service. TRION will remedy any such defects if they appear after installation from an Authorized TRION Dealer, subject to terms and conditions of this Limited Lifetime Warranty stated below: 1. THIS LIMITED LIFETIME WARRANTY IS GRANTED BY TRION, 101 MCNEILL ROAD, SANFORD, NC 27330. 2. This warranty shall extend only to any noncommercial owner who has purchased the residential media air cleaner other than for purposes of resale. 3. All components are covered by this limited warranty except expendable items such as charcoal filters and filter cartridges. 4. If within the warranty period, any TRION residential media air cleaner unit or component requires service, it must be performed by a competent heating and/or air conditioning contractor. 5. In order to obtain the benefits of this limited lifetime warranty, the owner must notify the dealer or distributor in writing or by phone, of any defect within 30 days of its discovery. If after reasonable time you have not received an adequate response from the dealer or distributor, notify in writing, by phone, or email: TRION, 101 McNeill Road, Sanford, NC 27330 / 1-800-884-0002 / customerservice@trioniaq.com. 6. This limited warranty does not apply to any part or component that is damaged in transit or when handling, has been subject to misuse, neglect or accident, has not been installed, operated and serviced according to TRION s instruction, has been operated beyond the factory rated capacity, or altered in any such way that its performance is affected. There is no warranty due to neglect, alteration, or ordinary wear and tear. TRION s liability is limited to the replacement of defective parts or components and does not include the payment of labor charges to remove or replace such defective parts. 7. TRION WILL NOT BE RESPONSIBLE FOR LOSS OF USE OF ANY PRODUCT, LOSS OF TIME, INCONVENIENCE, OR ANY OTHER INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES WITH RESPECT TO PERSON OR PROPERTY, WHETHER AS A RESULT OF BREACH OF WARRANTY, NEGLECT OR OTHERWISE. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE LIMITATION OR EXCLUSION IN THE PRECEDING SENTENCE MAY NOT APPLY TO YOU. 8. THIS WARRANTY GIVES YOU SPECIFIC RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE. 9. TRION reserves the right to make changes in the design and material of its products without incurring any obligation to incorporate such changes in units manufactured before the effective date of such a change. www.trioniaq.com 5

TRION 101 McNeill Rd. Sanford, NC 27330 P: 800.884.0002 F: 800.458.2379 www.trioniaq.com customerservice@trioniaq.com Form No. 247381-001 Rev. 10/17 TRION 2017. All Rights Reserved.