Aqua-safe. Waterproof Plug & Socket Connectors Simply better designed

Similar documents
Powerline QC. Single Power Connectors. Ten 47 Limited

MX150L ASSEMBLY INSTRUCTIONS

EASYBOX Series. Weather-proof enclosures

Powerline. Single Power Connectors. Ten 47 Limited

LIVE DEMATEABLE CONNECTOR TERMINATION / HOOK UP PROCEDURE

Spec Sheet: IEC309 Switched Socket, Horizontal 16A. Part Number

Powerline. Single Power Connectors. + Ten 47. Ten 47 Limited

Spec Sheet: IEC309 Panel Socket, Angled 16A IP67. Part Number

PIL0478 ISSUE 01/ 07/16

900 Series Buccaneer BUCCANEER FOR POWER. IP68 rating tested at 1.054kg/sq cm (15lb/sq in) 10m depth for 2 weeks. Trailing Neutral on 5 pole

Cable Glands & Accessories

IP65/IP66 ABS/Polycarbonate Screw Lid Boxes

900 Series Buccaneer BUCCANEER BUCCANEER

400 Series Buccaneer BUCCANEER POWER. bulgin

Power Distribution Enclosures. Pillar shells and in-ground feeder pillars

LIFEGUARD PRODUCT CATALOGUE. power distribution system.

LUMOTAST FK. General data. Content

All our Eterna Emergency Exit Signage comply with current Exit Signage Regulations using the Signs Directive format.

ReadyMoor Series II. ReadyMoor Series II Quick Release Hooks and Capstans. Efficient cost effective mooring solutions off the shelf. Ready to go.

Unused flameproof threads for cable glands have to be closed with certified plugs.

POWER CONNECTOR TERMINATION / HOOK UP PROCEDURE

1SLC811001B0202. Wiring ducts. the widest choice for greater convenience and speed at work

Underfloor to desk 231

XC VALVE RANGE. alco-valves.com

IEC60309 PLUGS AND SOCKETS

EPIC CIRCON M23 Series

Datasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX

Comfort and safety when you need it most

sira CERTIFICATION KSG, KSGDS and KCG Range of Cable Glands

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

7000 Series Buccaneer

International approvals.

Boston Gear LOR Series

SERVICE PROCEDURES FOR CLUTCH HYDRAULIC UNITS

The specified data apply only if actuators/signal indicators are combined with contact blocks and lamp sockets within the same product range.

ROM Series. Established Leaders in Flow Control. Installation Manual. Valve Actuators

Creative Links to World Electronics

MK Electric IP Solutions

SRS SEALED ROTARY SENSORS

4000 Series Buccaneer

DEVI EasyConnect Heating Cable Connection System

Safety Lampholders and Pendants

Energy Supply Systems

A good connection. International approvals.

NS Feeder pillar up to 3200A

P r o d u c t o v e r v i e w

P17. Tempra PRO. a range you can rely on CATALOGUE PAGES INSIDE. GLOBAL SPECIALIST in electrical and digital building infrastructures

Pan and Tilt Head CDD2416-T

Meadow Park, Bourne Road, Essendine, Stamford, Lincolnshire, PE9 4LT Tel Fax Web.

AMPSEAL 16* Connector System 24 JUN 13 Rev C


6000 Series Buccaneer. Secure, quick connector mating and release. 30 twist locking Tamperproof lock prevents accidental un-mating

METERING VALVE 2" STEM GUIDED

What is the secret to our success?

Easytork Solenoid Valve IOM

HP20 Series. Utilizes a Small #20 Size Shell Accommodates Up to 646 MCM Cable Patents Pending

BYV Series Butterfly Valve Product Guide FLOW CONTROL

Cable Connectors GET CONNECTED

Emergency Light Fitting for Fluorescent Lamps Series 6009

CHECKLIST & COMPONENTS

7000 Series Buccaneer

STRAIGHT BLADE PLUGS & CONNECTORS

In-Place-Inclinometer Installation Manual

The Teconnex V Clamp

Washdown Industrial/Light Marine UniGuard

INSTALLATION I N S T R U C T I O N S

anchor winches mini genius

The Grasshopper. Golf Buggy. Owners Manual Classic - Cobra - Junior (Twin Motor)

INFO. SHEET: E1:1 INSPECTION & TESTING OF ELECTRICAL EQUIPMENT

Pöppelmann KAPSTO product range: 3,000 solutions. Free samples. No minimum order quantities. Available from stock. We are doing it.

BATH FILLER & BATH / SHOWER MIXER Installation & aftercare instructions

Transair: Advanced Pipe Systems Pocket Installation Guide [1/2"] [1"] [1 1/2"] [2"] [2 1/2"] [3"] [4"] [6"]

Underfloor Busbar. Betatrak Underfloor Busbar. 82

LMV RANGE CONTENTS. General information

ISO 1500 TORQUE WRENCH LOADER WITH 90 ROTATION

Commando Safetyswitch

IP44 - IP66 Rated RCD, Power & Cable Management

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

Product Data For FARNELL

workshop specifications Plexo³ IP 65 cabinets

Order from MARYLAND METRICS P.O. Box 261 Owings Mills, MD USA web:

P: E: W: 1 of 20 MEG DS 034 A

Central Battery Systems

Product Brochure. Dodge ISN bearings

ACOUSTIC CONTAINER RANGE

Rittal CM Compact System Enclosures

E3 VISE ACTION Compression Latch

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Eazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

weatherproof wiring accessories IP rated accessories designed to protect against water and dust ingress in the most arduous of conditions

Electrak power track underfloor power distribution systems

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Figure 1: HB Series Ball Valve Cross Sectional View DISASSEMBLY WARNING: MAKE CERTAIN THE SYSTEM IN WHICH THE VALVE IS INSTALLLED IS EXHAUSTED OF ALL

WRENCHES TORQUE. Motorq Professional Torque Wrenches

Water-Proof Connectors

RAFIX 22 QR. General data. Content

Supply+ are the leading supplier of specialist products.

DAH Left Hand Hose Inlet Kit Instruction Sheet For Use with 700 SERIES DAH Dilution at Hand Blend Centers

Transcription:

Aqua-safe Waterproof Plug & Socket Connectors Simply better designed

2 Aqua-safe Simply better designed Elkay s Aqua-safe is the only all-round solution for safely connecting and carrying power through wet / damp environments or adverse weather conditions. The range available from Elkay covers a multitude of domestic, commercial and industrial uses. Typical applications include: Gardens to power outside lighting and water pumps Local Authorities / Councils Temporary Street Lighting Marine and Boat Builders Portable electricity generator manufacturers There is an increasing demand for safe outdoor electrical applications and therefore a need for a range of cost effective, fully waterproof connectors. The main features of the Elkay Aqua-safe range are outlined on these pages. Product features Increased cable acceptance range The existing product range has been extended to increase the cable acceptance ranges: Improved current capacity 10 amps, now increased to 16 amps. Simplified assembly of inner connectors Active latch mechanism to access the inner connectors for quicker wiring. Click latch mechanism The conventional approach of connector halves that screw together has been discarded and replaced by a simple click latch mechanism. A latch system is more reliable than a screw thread as there is no doubt when the connector is fully mated. Aqua-safe s latch mechanism is also highly innovative with only one moving part. This is a sliding ring that carries three lugs, which engage with slots on the male section of the connector. The lugs are totally enclosed so there is no risk of damage to the catches. Collar allows fast mating and un-mating of connector halves 5 9mm (existing) 8 13mm (new) 12 16mm (new) Simple click latch mechanism for a positive, secure installation Housings are keyed to prevent mis-assembly Cable gland technology For the cable entry points, Elkay have utilised existing cable gland technology to provide clamping and waterproofing at either end of the connector body. Because the seal deforms so well, each size of gland can accommodate more sizes of cable than competitive products, helping reduce inventory. Secure sealing To ensure effective sealing between mating housings, we have opted for a single O ring that is carried in a groove on the male half of the connector and is a comfortable fit inside the second half of the connector. With Elkay Aqua-safe, if the latch is snapped home then the sealing will work. Our design provides both an audible and tactile response when activated. The O ring sealing system provides IP68 protection (at 2 bar). Effectively the Elkay Aqua-safe range is waterproof up to a depth of 20 metres. Tel: +44 (0)1686 611500 Direct Sales: +44 (0)1686 611511 Fax: +44 (0)1686 611501

3 Proven cable gland technology for high cable sealing and retention Flexibility Connector halves are interchangeable so both male and female halves of a connector will fit in either housing. 3 pole 250V versions are standard, but connectors to suit low voltage applications are also available. Versions to accept 1-8 poles are under development. Sealing caps for both male and female housings To maintain IP rating when the connectors are separated. Ingress protection to IP68 2 bar (20m depth). Dust proof and water tight for use in a variety of industrial and commercial applications. To assemble, cable is pushed though the housing without taking the gland components apart Safe connections Connector elements simply slot into the housings and are rotated to lock them. Each half rotates counter to its mate so the two stay locked in once mated. Guides and stops inside the housings ensure the connectors stay aligned to each other. Each terminal is identified for ease of assembly Bulkhead or panel mounted fittings It is now possible to fix the mounting of one half of the Aqua-safe connector either by bulkhead (flanged) or panel mounting (threaded). Bulkhead screwed male and female options Bulkhead flanged male and female options Email: sales@elkay.co.uk www.elkay.co.uk

4 The In-Line Aqua-safe range Simply better designed In-Line 5 to 9mm In-Line 8 to 13mm Standard in-line product The in-line range is typically used where temporary connections are required for power. The range offers a variety of cable acceptance sizes, whilst maintaining a compact working envelope. The housings are defined as either Female or Male. The Female housing has the collar moulding, and the Male housing is smaller in diameter, and fits inside the opposite housing. The inner connectors are defined as either a Plug or Socket according to the metal inserts. The product can be supplied as a mated pair, or as separate halves to mate with either bulkhead or panel mounted version shown on the opposite page. The table below shows the standard stock items, but other variations are available. Standard assembly is the socket connector supplied in the Male housing. Elkay always recommend that the Aqua-safe be installed with power connected to the socket inner connector, but if a specific application dictates this is not possible or if the connections are incorrectly assembled during installation, the connector remains touch-safe. Refer to the table on inside back cover for further details on customising Aqua-safe. 80mm max MALE 85mm max In-Line 12 to 16mm ø 40mm ø 35.5mm FEMALE 140mm max ASSEMBLED Description Connector Details Cable Range Pack Qty 185-9000 Aqua-safe In-Line Waterproof Connector Assembly 3 Pole Plug & Socket 5-9mm 1 185-9100 Aqua-safe In-Line Waterproof Connector Assembly 3 Pole Plug & Socket 8-13mm 1 185-9200 Aqua-safe In-Line Waterproof Connector Assembly 3 Pole Plug & Socket 12-16mm 1 185-0A1011-P030-1 Aqua-safe In-Line Waterproof Female Housing 3 Pole Plug 5-9mm 1 185-0A1021-P030-1 Aqua-safe In-Line Waterproof Female Housing 3 Pole Plug 8-13mm 1 185-0A1031-P030-1 Aqua-safe In-Line Waterproof Female Housing 3 Pole Plug 12-16mm 1 185-1A1011-S030-1 Aqua-safe In-Line Waterproof Male Housing 3 pole Socket 5-9mm 1 185-1A1021-S030-1 Aqua-safe In-Line Waterproof Male Housing 3 pole Socket 8-13mm 1 185-1A1031-S030-1 Aqua-safe In-Line Waterproof Male Housing 3 pole Socket 12-16mm 1 Low voltage versions are also available as standard, see specification sheet on page 7. Tel: +44 (0)1686 611500 Direct Sales: +44 (0)1686 611511 Fax: +44 (0)1686 611501

5 The Bulkhead Aqua-safe Simply better designed Standard bulkhead product Bulkhead screwed Male If power is being distributed and controlled from a fixed installation, it may be more appropriate to mount products into an enclosure or electrical equipment. As an alternative to the in-line connector, Elkay offer complimentary mounting options including; Chassis / panel mounting (screwed) Supplied with M25 Locknut and Sealing Washer as standard, the thread has flats to orientate the housing during installation. Bulkhead / surface mounting (flanged) Flanged to suit surface mounting where space is restricted behind the application. Bulkhead screwed Female Each bulkhead / panel mounted housing can be used in conjunction with the appropriate mating in-line connector. Mounting details and general dimensions Screwed Bulkhead flanged Male MALE FEMALE Flanged Bulkhead flanged Female MALE FEMALE Description Mounting Style Connector Details Pack Qty 185-0B1000-P030-1 Aqua-safe Bulkhead Female Housing Flanged 3 Pole Plug 1 185-0E1000-P030-1 Aqua-safe Bulkhead Female Housing Screwed 3 Pole Plug 1 185-1B1000-S030-1 Aqua-safe Bulkhead Male Housing Flanged 3 Pole Socket 1 185-1E1000-S030-1 Aqua-safe Bulkhead Male Housing Screwed 3 Pole Socket 1 Email: sales@elkay.co.uk www.elkay.co.uk

6 Aqua-safe accessories, assembly and installation Accessories Female Sealing Cap supplied with Connector Strap Male Sealing Cap supplied with Connector Strap Sealing caps IP 68 Sealing caps can be fitted to each individual housing to maintain protection when the connectors are separated. This ensures electrical safety at all times, even when the connectors are not in use. The caps are operated in exactly the same manner as the connectors, by the latch mechanism held within the collar. A strap is also provided to retain the sealing cap onto the housings, for light static applications. Description Pack Qty 185-6100 Aqua-safe Male Sealing Cap with strap to suit all Female Housings 100 185-6200 Aqua-safe Female Sealing Cap with strap to suit all Male Housings 100 Assembly and installation To disconnect Aqua-safe, firstly separate the two halves. This is achieved by simply gripping the collar and pulling in the direction of the arrows. This un-locks and separates the connector. Mating Aqua-safe is even easier. Guidance ribs are provided on each housing to help align the two halves of the connector. Simply push the housings together, and full engagement is assured by an audible click which means both halves are locked together and the seal is complete. The design process utilised to develop Aqua-safe ensures that it is only possible to mate the housings providing the inner connectors are correctly installed. The internal connector elements simply slot into the housings and are rotated to lock them in place. Each half rotates counter to its mate so the two stay locked in once mated. Guides and stops inside the housings ensure the connectors stay aligned to each other and prevent mis-insertion. During the connection and disconnection process, the centre earth pin is 2mm longer than the others, and is the first one to make contact and the last one to break contact. This ensures electrical safety. As with all electrical connectors, it is important that the power is switched off before disconnecting the Aqua-safe. The Aqua-safe Active Latch Access to the inner connectors is quick and simple by inserting a screwdriver into the release latch, and rotating the connector 45 degrees anti-clockwise (until it reaches the stop). The connector is then free to slide out of the housing to terminate the individual conductors. Once the inner connector has been removed, the cable is simply pushed through the housing without disassembling the gland. This helps to save time during installation. The conductors are then assembled into each appropriate terminal. A cutting guide for the conductors is provided on the housing alignment ribs.the inner connectors are then re-fitted by sliding back into the housing and rotating 45 degrees clockwise so that the latch clicks into the locked position. To finish the assembly, the gland nut is then tightened onto the outer sheathing of the cable to provide total sealing and retention. 3 Pole Plug Inner Connector with active latch. 3 Pole Socket Inner Connector with active latch. Tel: +44 (0)1686 611500 Direct Sales: +44 (0)1686 611511

Specification 7 Approvals IEC 61984 Electrical Performance Voltage Rating: 250 Va.c./d.c Current Rating: 16 Amps (Max.) Wire Capacity: 4mm 2 (Max.) Temperature Range Minimum: Maximum: 25º Centigrade +80º Centigrade Waterproof Rating IP68 to 2 Bar (equivalent to 20 metres water depth approx.) Materials Inner Plug & Socket Connector: Outer Housing: Seals: Colour: Polycarbonate Glass Filled Nylon Nitrile Rubber Black (other colours pending) How to specify Aqua-safe Elkay have devised a part number which can be tailored to your specific product requirement. The table below show typical part numbers and how they are constructed. Each digit refers to specific criteria of the product. Our sales team are always ready to help you when you place your order, please find their contact number below. The 17 digit part number should be constructed using the options given below 185-0 A 10 11 - P03 1 * - 1 Available now: HOUSING HOUSING TYPE HOUSING GLAND SIZE / INNER CONNECTOR CAP / PACKING DETAILS COLOUR/MATERIAL TYPE STRAP DETAILS 0=Female (250V) A=In-Line 10=Black 00= Bulkhead 000 =None 0 =None 1=Single version (N/A) 1=Male (250V) B= Bulkhead 11=5 9mm P03 =3 Pole plug (250V) 1 =Male 2= Bulk pack(qty=10) flanged straight (single) 2=Female (50V - Low voltage) E = Bulkhead 21= 8 13mm S03 =3 Pole socket (250V) 2 =Female 3= Bulk pack(qty=25) screwed straight (single) 3=Male (50V - Low voltage) 31= 12 16mm PL3=3 Pole plug 3 =Male & Female 4= Bulk pack(qty=50) (single) (50V - Low voltage) SL3=3 Pole socket (50V - Low voltage) 5= Bulk pack(qty=100) Under development: (contact Sales/Engineering for availability) C= Bulkhead 20=Blue 1F =5 9mm P04 =4 Pole plug (250V) 4 =Special flanged 45º (flat) D= Bulkhead 30=Yellow 1M=5 9mm P08 =8 Pole plug (250V) flanged 90º (multi) F = Bulkhead screwed 45º 40=Grey G= Bulkhead 2F =8 13mm S04 =4 Pole socket (250V) screwed 90º (flat) 2M=8 13mm (multi) 3F =12 16mm (flat) 3M=12 16mm (multi) S08 =8 Pole socket (250V) NOTE: *1 WHEN SPECIFYING SEALING CAPS, IT SHOULD BE NOTED THAT A MALE CAP FITS INTO A FEMALE HOUSING, AND A FEMALE CAP FITS ON TO A MALE HOUSING. THEREFORE, DO NOT SPECIFY A MALE CAP TO FIT WITH A MALE HOUSING, AND VICE-VERSA. 2 ANY 0 SHOWN IN THE PART No. IS NUMERIC, NOT ALPHANUMERIC. 3 PLEASE NOTE THAT THE MATERIAL COLOUR (DIGITS 7 & 8 OF THE PART No.) REFERS TO THE MALE & FEMALE HOUSINGS ONLY. THE INNER CONNECTOR (PLUG & SOCKET) IS SUPPLIED IN WHITE MATERIAL FOR 250V, AND BLACK MATERIAL FOR LOW VOLTAGE (50V) AS STANDARD. 4 IF NOT SPECIFIED OTHERWISE, ELKAY WILL SUPPLY THE PLUG INNER CONNECTOR IN THE FEMALE HALF AND THE SOCKET INNER CONNECTOR IN THE MALE HALF (AS STANDARD WITH THE IN-LINE PRODUCTS). Fax: +44 (0)1686 611501 Email: sales@elkay.co.uk www.elkay.co.uk

Other Products available from Elkay Electrical include; Cable Glands Terminal Blocks and Connectors Energy Management Switches and Accessories Din Rail Terminals PCB Terminals Enclosures Bespoke Engineering Solutions With over 75 years experience, Elkay is the UK s premier manufacturer and distributor of interconnect and energy management solutions. As we have grown, so has our reputation for providing innovative and value-engineered products. And with our integrated design and manufacturing capability as well as our dedication to providing exceptional service, we are consistently able to match the changing needs of our diverse customer base. Our commitment to quality is demonstrated through our company-wide ISO 9001: 2000 certification and we are also represented on key European standards committees to help raise the standard of product safety. As part of an international group of companies we are continuing to build on our unrivalled expertise to increase the competitive performance of our customers. ELKAY ELECTRICAL Manufacturing Co. Ltd Mochdre Industrial Estate, Newtown, Powys, Wales SY16 4LF Tel: +44 (0)1686 611500 Direct Sales: +44 (0)1686 611511 Fax: +44 (0)1686 611501 Email: sales@elkay.co.uk www.elkay.co.uk LIT-067