Installing an Auxiliary Pressure Control Module

Similar documents
Installing an Auxiliary Pressure Control Module

Installation Guide. Auxiliary Pressure Control Manifold on 6890 GC Accessory G1570A

Installing a Purged Packed (PP) Inlet

Installing a Cool On-Column Inlet

Installing a PTV Inlet

Installing a PTV Inlet

Installing the CO 2 Cryogenic Oven Cooling Kit

Installation Guide. Flame Ionization Detector on a 6890 GC. Accessories G1561A, G1562A, G1591A, G1598A

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

Installing the Flame Ionization Detector EPC Flow Control Manifold

Installation Guide. Thermal Conductivity Detector on a 6850 GC Accessory G2623A

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

Installation Guide. Purged Packed Inlet, Electronic Pneumatics Control on 6890 GC Accessory G1551A

Agilent G1554A On-Column Capillary Inlet with EPC

Installation Guide. Heater Interface Cable for Mass Sensitive Detector Accessory G1590A

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

Installation Guide NPD/ECD Chemical Filters Accessory 19199N

Installation Guide Thermal Conductivity Detector Accessory 19232E

Installing a Purged Packed Inlet

Nickel Catalyst Tube Accessory 19205A

Valve Box and Valve Accessories G4315A, G4316A, G4317A

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory

Agilent G3510A/G3511A Multimode Inlet

Installing the 6850 Direct Valve Column Connector Kit

Nickel Catalyst Tube on a 6820 GC, Accessory G4318A

Agilent G2738A Upstream Capillary Interface

Replacing the Battery in the Patriot SPS 250, SPS 300 and SPS 450

Installation Instructions. PowerFlex 700 Drive - Frame 8 Components Replacement

Agilent G4367A Auxiliary Electronic Pressure Control (Aux EPC) Module

Replacing the Batteries in the Fortress LI 660

29 Installation Step 1. Unpacking the GC Cable diagrams Step 2. Placing the GC system on the benchtop Step 3. Turning the power on

SITRANS F. Ultrasonic Flowmeters. Hi-Precision Mounts. Operating Instructions. Answers for industry.

Model 4430 Photoionization Detector (PID) Operator s Manual

HP Adjustable Depth Fixed Rail Kit Installation

Deans Switch Microfluidics

Agilent 490 Micro GC Internal and External Mount Genie Filter Brackets

Electrically Held to Mechanically Latched Contactor

N/S= Not Shown Bold = Part available for purchase. Italic = Part not available for purchase, listed and shown for reference only.

Agilent G2333B (Single) and G2334B (Dual) Flame Photometric Detectors

Agilent G2855A Deans Switching System

Agilent 6890 Gas Chromatograph

260 Solvent Vapor Exit Accessory

MA-5200 Series MA-5300 Series

Forbidden Diesel Performance Ford 6.7L Powerstroke EGR Delete Instructions 6.7L EGR DELETE BY FORBIDDEN DIESEL PERFORMANCE. Page 1

VISOR AUDIO KIT P/N , APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

Siemens Drives & PLCs

NPD to FID conversion on SRI 8610C or 310C GC July2012

5000TOC Sensor Service Manual

ELECRAFT KX3 Application Note

Alcatel-Lucent 7310 DC Metro Cell AWS (B4) Kit MC-DBR1, MC-DBR2, MC-DBR3, MC-DBR4, MC-DBR5. Installation Manual

If there is additional labor or other costs above the 4 hrs labor you must call VMAC for approved coverage

Exchange of rollers from the XTS-Mover

PowerFlex 700 Drive - Frame 8 Components Replacement

DANI Transformer Oil Gas Analyzer

Installation Instructions. PowerFlex 700 Drive - Frame 7 Components Replacement

Galaxy VM. Battery Breaker Box Installation 09/

HP Modular Cooling System 200/100 Options Installation Guide

MP-5400 Series. Application. Features. Applicable Literature. Electronic Positive Positioning Hydraulic Actuator General Instructions

Agilent 6850 Series II Network GC System G2630A Performance Specifications

1310 Inlets. 1 of 36. Jun Illustrated Parts Breakdown Agilent 6890 Gas Chromatograph Service Manual

Universal Splice Tray Installation Instructions

Switching DC Power Supply

S4M Pulley and Gears Maintenance Kit

CP-8301-xxx Series. Application. Features. Applicable Literature. 1 to 15 Vdc Input Electronic Actuator Drive General Instructions

Agilent G2647A (Single) and G2648A (Dual) Flame Photometric Detector Update Kits

Torque Module Installation and User Guide for model 250i Motorcycle Dynamometers.

Troubleshooting Tips & Tricks for your GC Analyzer & CFT Application

Operation and Maintenance Instructions Manual BOOSTER. Volume amplifier

PowerFlex 700 Drive - Frame 9 Components Replacement

Corolla TNS600. RHD installation instructions. Model year: 2004 Vehicle code: **E12*R-****W

9.2, 9.2s, 9.20, 9.20s Treadmill

Installing the G2743A/G2745A Valve Actuator Kits

In addition to this instruction sheet, the following are included in this kit (some additional parts are included for future maintenance):

HP BladeSystem c7000 Carrier-Grade Options Installation Guide

10260S Series Actuators Auto-Manual Switch Replacement Instruction

Previa (RHD) - MMC PZ425-R PART NUMBER INSTALLATION INSTRUCTIONS TOYOTA NAVIGATION SYSTEM. (Production date 05/03)

Encore HD Mobile Powder Coating System

ISSUER: WRC 10/29/10 ENGINEERING: PROD/MTL: QA APPROVAL: REVISION HISTORY

Agilent G3348B Flame Photometric Detector

Oil-free piston compressors KK and piston vacuum pumps KV

Read these instructions thoroughly before attempting to install this option.

Battery Replacement. Installation Instructions. Summary of Changes. Catalog Number 2711P-RY2032. Original Instructions

Installation Note for Solvent Selection Valve Upgrade Kit (G1360A)

INSTALLATION OF OPTIC 3 INJECTOR SYSTEM ONTO AN SHIMADZU GC-2010 GAS CHROMATOGRAPH.

ComfortPoint Programmable Lon, VAV/Unitary Controllers

Lamp House with 2.5 kw lamp

I. Safety precautions

OPERATING MANUAL. High-efficiency AR Series. Stepping motor and driver package. Introduction. Applicable motor. Before use

An ISO 9001 Company. BOP 1KW-MG FIRMWARE RETROFIT KIT

Intended Users This manual is meant for Gasboy Authorized Service Contractors (ASCs) who will install this kit on Atlas units.

Agilent and ASTM. Update on Recent Activities. Page 1

BroadBand PowerShield. 20 AHr Battery. User Manual

MP and MP Diaphragm and Seal Kits for MP8000 Series Actuators

CoolWave 2 Phase Control Board and Cable Replacement Kit

UG-8 Speed Adjusting Devices. Product Manual (Revision NEW) Original Instructions. Pneumatic and Manifold Speed Setting for UG Type Governors

The pneumatic applicator complies with the following safety guidelines: CE

TOYOTA TACOMA EC REARVIEW MIRROR Preparation

DASH AUDIO KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Instr Rev 01 04/16 Page 1 of 6. Verify accessory fitment at Polaris.com.

GENUINE ACCESSORIES INSTALLATION INSTRUCTIONS. ITEM QTY DESCRIPTION Usage Chart Service Part Number. 1 1 Mirror Assembly w/ Compass 1

Section 5: Parts Replacement

Transcription:

Installing an Auxiliary Pressure Control Module Agilent 6850 GCs Accessory G3349B This kit contains: Description Quantity Cable tie.062-.625 diameter 2 Hex nut w/lockwasher 1 Disposable wrist strap 1 Minifold label 1 Restrictor kit 1 FID air restrictor (brown) 3 Blue dot restrictor 3 O-rings (6 pk) 1 Tube zero restrictor 3 External H 2 flow limiter 2 External Flow Restrictor Install Guide 1 Aux. press. control module assembly (with covers) 1 Back panel replacement for the GC 1 6850 GC user information CD 1 ChemStation software CD 1 Installation sheet (this document) 1 The module is factory-assembled. Do not disassemble it during installation.

Parts identification Parts identification Hex nut w/lockwasher Minifold label Aux. pressure control module assembly 2

Required tools Required tools Torx T-20 screwdriver Needle-nose pliers Overview Caution Before starting, review the safety information listed at the end of this document. 1. Disconnect the GC. 2.. 3. Restore the GC to operating condition. 3

Disconnect the GC Disconnect the GC WARNING Hydrogen gas is flammable and potentially explosive. Before replacing the module, turn off the hydrogen gas at the source. 1. Turn off the GC and unplug the power cord. Allow time for all heated zones to cool. 2. Disconnect all cables from the GC. 3. Turn all gases off at their sources. Disconnect the carrier and detector gas tubing from the back panel of the instrument. Disconnect gas supply tubing from these fittings 4

4. Remove the seven T-20 screws on the back panel. Save the screws. Remove 5. Tilt the top of the panel away from the GC. If you have a Series II GC, save this panel. Otherwise, set this panel aside because you will no longer use it. A new panel comes with the kit. Caution Always hold the module by its support bracket to avoid damaging board components. 1. Change one or more auxiliary channel frits, if needed. See Changing the flow restrictors (optional) on page 8. 5

2. If you will be using the back panel from the kit, use needle-nose pliers to remove the knockouts for the ribbon cable and power cable slots. Ribbon cable slot Low voltage power High voltage power 3. Remove the tape from around the new control module and thread the ribbon cable through the slot in the back panel. 4. Attach the ribbon cable to the pneumatics control board (at P9). Ribbon cable connector 6

5. Gather the excess gas tubing from the gang fitting block in a loop and tie it together with a cable tie. Cable tie Gas tubing 6. Attach the control module to the back panel by hooking the tabs on the module just inside the ribbon cable slot. Position it so you can insert the threaded stud through the hole in the panel. On the inside, use the hex nut with lockwasher to hold the stud in place. 7. Install the back panel. Nut holding stud in place Control module 7

Changing the flow restrictors (optional) The auxiliary channels are controlled by a pressure setpoint. To work properly, there must be adequate flow resistance downstream of the pressure sensor. The auxiliary channel pneumatics manifold provides a frittype restrictor for each channel. Four frits are available: Frit marking Flow resistance Agilent part number Blue Dot High 19234-60660 Red Dot Medium 19231-60770 Brown Dot Low 19231-60610 None (brass tube) Zero G1570-20540 The red dot frit is in all three channels when the instrument is shipped. Figure 1 and Figure 2 show approximate pressure/flow relationships for the three dot frits, assuming there is no significant resistance downstream of the frits. If the Zero resistance frit is installed, the user must provide flow resistance downstream and generate the pressure/flow relationships. WARNING When hydrogen is used, dangerously high flows are possible if insufficient flow resistance is provided downstream of the supply tube. Always use either the High (blue dot) or Medium (red dot) frit with hydrogen. You may also want to use the restrictor kit that comes with this accessory. Its installation document describes using it for the 6890 GC, but still applies to the 6850 GC. 8

80 (Ambient conditions: 25 C, 14.7 psia) 70 19234-60660 (blue dot) 60 Minimum source pressure (psig) 50 40 19231-60770 (red dot) 30 19231-60610 (brown dot) 20 10 0 0.1 1.0 10.0 100.0 1000.0 Gas Flow in ml/min Figure 1. Pressure requirements for AUX EPC flow restrictors with air, nitrogen, or helium 9

80 (Ambient conditions: 25 C, 14.7 psia) 70 60 19234-60660 (blue dot) Minimum source pressure (psig) 50 40 19231-60770 (red dot) 30 20 19231-60610 (brown dot) 10 0 0.1 1.0 10.0 100.0 1000.0 Gas Flow in ml/min Figure 2. Pressure requirements for AUX EPC flow restrictors with hydrogen 10

Changing an auxiliary channel frit 1. Locate the gang fitting block. It connects the three gas outlet tubes for the auxiliary channels to the pneumatics module. Gang fitting block 2. Remove the screw that holds the block to the pneumatics module. Pull the block free of the module and rotate it so that the frits are on top. Aux 4 Gas restrictors (frits) Aux 5 Aux 3 Aux 3 Aux 5 Aux 4 Gas outlets 3. Pull the frit to be changed out of the block. Also remove the O-ring that seals it. 4. Place an O-ring on the new frit. Place the O-ring/frit combination in the block. 5. Reconnect the block to the pneumatics module. Tighten the screw firmly. 11

Restore the GC to operating condition Restore the GC to operating condition 1. Reconnect all cables. 2. Restore power. 3. Display the Status / Settings / Auxiliary screen on the control module. If the module is installed correctly, this screen appears. An actual flow value appears when gases are off or not connected. This is not an error. After the gases are connected and the detector is operational, the actual flow values are equal to the setpoint values. If the screen reads Aux not installed, recheck your cable connections. 4. Enter 0 in each Aux field (3, 4, and 5) to zero the pressure sensors. 5. Connect the source gas lines to the module. 6. Restore carrier and other gases to the module and instrument. 7. Leak check all fittings. 12

Restore the GC to operating condition 13

Agilent Technologies, Inc. 2004 All Rights Reserved. Reproduction, adaptation, or translation without permission is prohibited, except as allowed under the copyright laws. Part number G3349-90007 First Edition, May 2004 Printed in USA Agilent Technologies, Inc. 2850 Centerville Road Wilmington, DE 19808-1610 Acknowledgements Torx is a U.S. registered trademark of Textron, Inc. Safety Symbols Warnings in the manual or on the instrument must be observed during all phases of operation, service, and repair of this instrument. Failure to comply with these precautions violates safety standards of design and the intended use of the instrument. Agilent Technologies assumes no liability for the customer s failure to comply with these requirements. In the manual A warning calls attention to a condition or possible situation that could cause injury to the user. A caution calls attention to a condition or possible situation that could damage or destroy the product or the user s work. On the instrument See accompanying instructions for more information. Indicates a hot surface. Indicates hazardous voltages. Indicates earth (ground) terminal. Indicates explosion hazard. Indicates radioactivity hazard. Indicates electrostatic discharge hazard. Indicates pinch hazard. G3349-90007