Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Similar documents
Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Operating instructions Solenoid interlock AZM /.. 1. About this document. Content

Operating instructions Switching cushion with safety function SSG-SK. 1. About this document. Content

Operating instructions Pull-wire emergency-stop switches EX-ZQ About this document. Content

Operating instructions Trapped key system SHGV / SVE / SVM. 1. About this document. Content

Operating instructions Actuator and Emergency exit AZ/AZM 200-B30 AZ/AZM 201-B About this document. Content

Operating instructions Solenoid interlock AZM About this document. Content

Operating instructions Safety sensor EX-CSS About this document. Content. 7 Disassembly and disposal 7.1 Disassembly Disposal...

Operating instructions Solenoid interlock AZM 170

Operating instructions Safety foot switches T.FH UEDR.. 1. About this document. Content

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Operating instructions Solenoid interlock AZM About this document. Content

AZM 161SK 12/12RKED/TU 024

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Encontrará el manual de instrucciones actual en su idioma oficial de la UE en nuestra página de Internet www. schmersal.net.

Safety door-handle system STS

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Operating instructions Solenoid interlock AZM About this document. Content

Solenoid interlock AZM 200 The non-contact interlock.

Technical data. Standards: IEC/EN BG-GS-ET-15

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Installation and Operating Instructions

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator

Safety Sensor CSS 180 Product Information

Safety switches with separate actuator

Safety rope switches with reset for emergency stop

ZB0050 / ZB0051 ZB0070 / ZB0071

Door locking devices. 4 Schmersal Industrial Switchgear

FL series position switches

Safety switches for hinges

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Ex m Solenoid Operator Type 0519

Guard locking systems for the protection of man and machine

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

Installation and Operating Instructions

SEPK 02.0 / SEPG 05.3 / SEP 01.0 / SEP 01.4 / SEPLC 05.2 / SEP 07.0 / SEP Operating instructions Two-hand control panel

Online data sheet. i15-em0123 Lock i15 Lock SAFETY LOCKING DEVICES

Operating Instructions

Safety switches with separate actuator

Operating Instructions

Safety rope switch without reset for simple stop

HST -LS Interlocking device (Translation of Original Manual)

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Safety rope switch with reset for emergency stop

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

EStrong-series Emergency Stop

LR-LX-LK-LW Safety Switches with separate actuator

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

SFS-UFS Single Foot Switches

CAUTION CM-SE CM-S21 CM-S41

F3S-TGR-KHL1/-KHL3/-KHL3R

Hinged Safety Door Switch

SG-B1 SERIES / SG-A1 SERIES

Operating Instructions

Position switches FR series

Position switches FD series

AC 100. Operating instructions Pneumatic Crimper AC 100. Date of issue: 05/2010. Keep for future use!

Floor and fine adjustment switches

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

MKey9-series Safety Interlock Switch with Guard Locking

Datasheet - MV8H Y

Position Switches Series 8074/2

Single foot switches - PX and PA series

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Sense7-series Non-contact coded safety switch

Safety switches for hinged doors

Components for safety applications

Safety. Operating instructions Solenoid valve VGP DANGER. Contents WARNING CAUTION. Changes to edition Elster GmbH Edition 10.

Switches with manual reset

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Translation of the Original operating instructions Lifting device Z 70 /...

NPA-CP Pendant Control Station

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

NPA-CP. Pendant control station. OPtiONs. FeAtures. CertiFiCAtiONs

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Operating Instructions

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

Safety. Operating instructions Solenoid valve for gas VG 6 VG 15/10 DANGER. Contents WARNING CAUTION. Changes to edition 07.15

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Gate Box with Safety Interlocking & RFID UGB-KLT Operating Instructions

Position Switches Series 8070/2

LK Position Switches TECHNICAL DATASHEET.

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

Transponder-coded. with guard locking

Transcription:

Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the safety switchgear. he operating instructions must be available in a legible condition and a complete version in the vicinity of the device. 1.2 arget group: authorised qualified personnel All operations described in this operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only. Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation. he machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components. 1.3 Explanation of the symbols used Information, hint, note: his symbol is used for identifying useful additional information. Caution: Failure to comply with this warning notice could lead to failures or malfunctions. Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine. x.000 / 01.201 / v.a. - 103001580- / D / 201-01-28 / AE-Nr. 5473 Content 1 About this document 1.1 Function...1 1.2 arget group: authorised qualified personnel....1 1.3 Explanation of the symbols used...1 1.4 Appropriate use...1 1.5 General safety instructions...1 1. Warning about misuse...1 1.7 Exclusion of liability...2 2 Product description 2.1 Ordering code...2 2.2 Special versions....2 2.3 Destination and use...2 2.4 echnical data...3 2.5 Safety classification...3 3 Mounting 3.1 General mounting instructions...3 3.2 Dimensions...3 4 Electrical connection 4.1 General information for electrical connection....4 4.2 Contact variants....4 5 Set-up and maintenance 5.1 Functional testing....5 5.2 Maintenance...5 Disassembly and disposal.1 Disassembly....5.2 Disposal...5 7 EU Declaration of conformity 1.4 Appropriate use he products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant. he safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter "Product description". 1.5 General safety instructions he user must observe the safety instructions in this operating instructions manual, the country-specific installation standards as well as all prevailing safety regulations and accident prevention rules. Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: www.schmersal.net. he information contained in this operating instructions manual is provided without liability and is subject to technical modifications. here are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed. 1. Warning about misuse In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded when safety switchgear is used. he relevant requirements of the standard ISO 14119 must be observed. 1

Solenoid interlock AZM 11../.. 1.7 Exclusion of liability We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with this operating instructions manual. he manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories. For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden; the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device. 2. Product description Manual release (for set-up, maintenance, etc.) he manual release is realised by turning the triangular key (M5 triangular key available as accessory), so that the locking bolt is pulled into the unlocking position. Please ensure that jamming by external influence on the actuator is avoided. he normal locking function is only restored after the triangular key has been returned to its original position. After being put into operation, the manual release must be secured by installing the plastic cover, which is included in delivery. Lateral manual release Manual release on the cover side or on the rear side (ordering suffix -ED/-EU) 2.1 Ordering code his operating instructions manual applies to the following types: AZM 11 ➀-➁➂ K➃-➄/➅-➆➇ No. Option Description ➀ CC Cage clamps SK Screw connection S Connector plug M 12 ➁ 11/03 1 NO / 4 NC with connector plug 11/12 2 NO / 3 NC with connector plug 12/03 1 NO / 5 NC 12/11 2 NO / 3 NC with connector plug 12/12 2 NO / 4 NC ➂ Latching force 5 N R Latching force 30 N ➃ A ➄ Lateral manual release ED Manual release on the cover side EU Manual release on the rear side ➅ Lateral emergency exit D Emergency exit on the cover side U Emergency exit on the rear side N Emergency release ➆ 024 U s 24 VAC/DC 110/230 U s 110/230 VAC ➇ Without LED G With LED riangular key K-M5 (101100887) available as accessory. Emergency release (ordering suffix -N) (Mounting and actuation only outside of the safety guard) he emergency release should only be used in an emergency. he solenoid interlock should be installed and/or protected so that an inadvertent opening of the interlock by an emergency release can be prevented. he emergency release must be clearly labelled that it should only be used in an emergency. he label can be used that was included in the delivery. o activate the emergency release in case of an emergency, the orange lever must be turned to the stop in the direction marked by the arrow. In this position, the safety guard can be opened. he lever is latched and cannot be returned to its original position. o cancel the blocking condition, the central mounting screw must be loosened to such extent that the lever can be turned back into its original position. he screw must then be re-tightened. Only if the information described in this operating instructions manual are realised correctly, the safety function and therefore the compliance with the Machinery Directive is maintained. 2.2 Special versions For special versions, which are not listed in the order code below 2.1, these specifications apply accordingly, provided that they correspond to the standard version. 2.3 Destination and use he solenoid interlock has been designed to prevent in conjunction with the control part of a machine, movable safety guards from being opened before hazardous conditions have been eliminated. Interlocks with the power to lock principle may only be used in special cases after a thorough evaluation of the accident risk, since the guarding device can immediately be opened on failure of the electrical power supply or when the main switch is opened. Emergency exit (Fitting and actuation only from within the hazardous area) o activate the emergency exit of the version in case of an emergency, the orange lever must be turned to the stop in direction marked by the arrow. he emergency exit function of the D and U versions is activated by pressing the red pushbutton. In this position, the safety guard can be opened. he blocking condition is cancelled by turning the lever in opposite direction or by pulling back the pushbutton. In unlocked position, the safety guard is protected against unintentional closing. Lateral emergency exit (ordering suffix -) Emergency exit on the cover side or on the rear side (ordering suffix -D/-U) he safety switchgears are classified according to ISO 14119 as type 2 interlocking devices. 2

Solenoid interlock he entire concept of the control system, in which the safety component is integrated, must be validated to the relevant standards. he user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level. 2.4 echnical data Standards: IEC 0947-5-1, ISO 14119, BG-GS-E-19 Enclosure: glass-fibre reinforced thermoplastic, self-extinguishing Actuator and locking bolt: stainless steel 1.4301 Contact material: Silver Coding level according to ISO 14119: low Protection class: IP7 Contact type: Change-over with double break Zb, galvanically separated contact bridges Switching system: A acc. IEC 0947-5-1 slow action, NC contact with positive break Positive break travel: 10 mm Positive break force: 10 N for each NC contact fitted Connection: screw terminals or cage clamps or connector plug Cable type: flexible Cable section: min. 0.25 mm², max. 1.5 mm² (including conductor ferrules) Cable entry: 4 x M1 Holding force F: 2000 N Latching force: 30 N for ordering suffix R Actuating speed: max. 2 m/s Actuating frequency: max. 1000 operations/h Mechanical life: > 1 million operations Ambient temperature: 25 C +0 C Electrical data: Utilisation category: AC-15, DC-13 Rated operating current/voltage I e /U e : CC, SK, S 4-pole: 4 A /230 VAC; 2.5 A / 24 VDC; S 8-pole: 2 A / 24 VDC Rated impulse withstand voltage U imp : CC, SK, S 4-pole: 4 kv; S 8-pole: 0.8 kv Rated insulation voltage U i : CC, SK, S 4-pole: 250 V; S 8-pole: 0 V hermal test current I the : CC, SK, S 4-pole: A; S 8-pole: 2 A Rated control voltage U s : 24 VAC/DC; 110/230 VAC Magnet: 100% ED Power consumption: max. 10 W Max. fuse rating: A gg D-fuse Required rated short-circuit current: 1000 A AZM 11../.. 2.5 Safety classification Standards: ISO 13849-1 Envisaged structure: - Basically: applicable up to Cat. 1 / PL c - With 2-channel usage and fault exclusion mechanism*: applicable up to Cat. 3 / PL d with suitable logic unit B 10d NC contact: 2,000,000 B 10d NO contact at 10% ohmic contact load: 1,000,000 Service life: 20 years * If a fault exclusion to the 1-channel mechanics is authorised. MF d B10d dop x hop n x 300 s/h op 0,1 x n op t cycle (Determined values can vary depending on the application-specific parameters h op, d op and t cycle as well as the load.) If multiple safety components are wired in series, the Performance Level to ISO 13849-1 will be reduced due to the restricted error detection under certain circumstances. 3. Mounting 3.1 General mounting instructions hree mounting holes are provided for fixing the enclosure. he solenoid interlock is double insulated. he use of an earth wire is not authorised. he solenoid interlock must not be used as an end stop. Any mounting position. he mounting position however must be chosen so that the ingress of dirt and soiling in the used opening is avoided. Unused actuator openings must be sealed with slot sealing plugs. he safety component and the actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling, pinning). Please observe the remarks of the standards ISO 12100, 953 and ISO 14119. 3.2 Dimensions All measurements in mm. 8 18 20 32 72 Use ype 4X (Indoor Use) and 12 connector fittings. ightening torque rating: 4.4 lb in. 30 25 90 2 30 8 22,5 28 2 104 130 3

Solenoid interlock AZM 11../.. 4. Electrical connection 4.1 General information for electrical connection he electrical connection may only be carried out by authorised personnel in a de-energised condition. AZM 11S-../.. with connector AZM 11S-12/11... 13 14 21 22 41 42 51 52 3 4 71 72 AZM 11S-11/12... 13 14 21 22 41 42 51 52 3 4 71 72 If the risk analysis indicates the use of a monitored interlock they are to be connected in the safety circuit with the contacts indicated with the symbol. Appropriate cable glands with a suitable degree of protection are to be used. Remove the thin walls of the mounting holes by inserting the cable entry. AZM 11S-11/03... 1234 11 12 21 22 41 42 51 52 3 4 71 72 1234 1234 Puncturing the wall of the holes with auxiliary tools (e.g. screwdriver) can cause damage. AZM 11...-G with LED he contacts are shown in closed and locked condition. 4.2 Contact variants Contacts are shown in the de-energised condition and with the actuator inserted. AZM 11SK-12/12...G AZM 11CC-12/12...G 21 41 13 +24 VDC 3 51 71 A1 51 71 3 A2 13 21 22 14 41 42 52 724 A2 13 21 22 14 41 42 A1 51 71 3 52 724 P 22 YE YE 42 14 4 52 72 + 14 21 22 41 42 51 52 4 71 72 GN AZM 11SK-12/12... AZM 11CC-12/12... 13 14 21 22 41 42 51 52 3 4 71 72 A1 51 71 3 A2 52 724 11 21 22 12 41 42 AZM 11SK-12/03... AZM 11CC-12/03... 13 14 21 22 41 42 51 52 3 4 71 72 A2 11 21 22 12 41 42 A1 51 71 3 52 724 Key A Positive break NC contact Monitoring the interlock according to ISO 14119 P Actuated Not actuated P Key 14: guard open + : +24 VDC : 0 VDC 4: unlocked System condition Solenoid control LED Contacts Safety guard open 24V 0V On On (not locked) and locked yellow actuator yellow magnet 21-22 41-42 13-14 3-4 51-52 71-72 24V 0V On On On 0V 24V On On On On LED on LED off 4

Solenoid interlock AZM 11SK-12/03...G AZM 11CC-12/03...G 21 22 41 42 11 12 Key 12: guard closed + : +24 VDC : 0 VDC 4: unlocked YE +24 VDC YE 3 4 51 71 52 72 + 12 21 22 41 42 51 52 4 71 72 GN 5. Set-up and maintenance AZM 11../.. 5.1 Functional testing he safety function of the safety components must be tested. he following conditions must be previously checked and met: 1. Fitting of the solenoid interlock and the actuator 2. Check the integrity of the cable entry and connections 3. Check the switch enclosure for damage 5.2 Maintenance A regular visual inspection and functional test, including the following steps, is recommended: 1. Check for tight installation of the actuator and the switch 2. Remove particles of dust and soiling 3. Check cable entry and connections Adequate measures must be taken to ensure protection against tampering either to prevent tampering of the safety guard, for instance by means of replacement actuators. System condition Solenoid control LED Contacts Damaged or defective components must be replaced. yellow actuator yellow magnet 21-22 41-42 11-12 3-4 51-52 71-72 Safety guard open 24V 0V On. Disassembly and disposal.1 Disassembly he safety switchgear must be disassembled in a de-energised condition only. (not locked) and locked 24V 0V On On On On 0V 24V On On On On On.2 Disposal he safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislations. LED on LED off 5

Solenoid interlock AZM 11../.. 7. EU Declaration of conformity EU Declaration of conformity ranslation of the original Declaration of Conformity K.A. Schmersal GmbH & Co. KG Möddinghofe 30 42279 Wuppertal Germany Internet: www.schmersal.com We hereby certify that the hereafter described components both in their basic design and construction conform to the applicable European Directives. Name of the component: AZM 11 ype: See ordering code Description of the component: Interlocking device with electromagnetic interlock for safety functions Relevant Directives: Machinery Directive EMC-Directive RoHS-Directive Valid up to April 19, 201 200/42/EC 2004/108/EC 2014/5/EU Valid as of April 20, 201 200/42/EC 2014/30/EU 2014/5/EU Applied standards: DIN 0947-5-1: 2010 DIN ISO 14119: 2014 Person authorized for the compilation of the technical documentation: Oliver Wacker Möddinghofe 30 42279 Wuppertal Place and date of issue: Wuppertal, February 1, 201 AZM 11-E- Authorised signature Philip Schmersal Managing Director he currently valid declaration of conformity can be downloaded from the internet at www.schmersal.net. K. A. Schmersal GmbH & Co. KG Möddinghofe 30, D - 42279 Wuppertal Postfach 24 02 3, D - 42232 Wuppertal Phone: +49 - (0)2 02-4 74-0 elefax: +49 - (0)2 02-4 74-1 00 E-Mail: info@schmersal.com Internet: http://www.schmersal.com