Installation Note for Solvent Selection Valve Upgrade Kit (G1360A)

Similar documents
Agilent 210/218 - Binary Pump

10 Maintenance. Agilent Technologies. This chapter describes the maintenance of the module Infinity Binary Pump User Manual

Agilent 210/218 - Isocratic Pump

Agilent SD-1 Purification System ml/min

1260 Infinity II Degasser User Manual. 5 Maintenance

Agilent InfinityLab LC Series 1260 Infinity II Delay Coil Organizer

Agilent 1290 Infinity II Ultra Low Dispersion Kit

Installation of the 2 position/10 port valve into the 1100 series thermostatted column compartment

Installing a Purged Packed (PP) Inlet

Agilent 1200 Series Manual Injector

Agilent 1100 Series Thermostatted Column Compartment. Reference Manual

Agilent InfinityLab LC Series Multi-wash Upgrade Kit

Installing a Purged Packed Inlet

Installing the CO 2 Cryogenic Oven Cooling Kit

Agilent 1260 Infinity Micro Degasser

Installing the 6850 Direct Valve Column Connector Kit

Agilent 1200 Series Micro Vacuum Degasser

Agilent 1260 Infinity Quaternary Pump VL

Agilent 1290 Infinity Autosampler

Installing a Cool On-Column Inlet

Installing a PTV Inlet

Agilent 1260 Infinity Manual Injector

Agilent 1290 Infinity Binary Pump

Agilent 1200 Series Nano Pump

Installing a PTV Inlet

Agilent 1260 Infinity Binary Pump VL

Agilent G4239C Valve Kit - Instructions

Agilent InfinityLab Quick Change Valve G4237A

Agilent 1290 Infinity Quaternary Pump

Agilent InfinityLab Quick Change Valve G4235A Instructions

Agilent 1290 Infinity Quaternary Pump

SCION tc ILLUMINATED DOOR SILLS Preparation

A-dec 541 Delivery System and 545 Assistant s Instrumentation

Agilent InfinityLab Quick Change Valves G4231A/C and G4232C/D

Agilent Valve Kit G4231A/B/C and G4232B/C/D

Dual-Needle Infinity II Upgrade Kit

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an in-out filter.

Agilent G1554A On-Column Capillary Inlet with EPC

Agilent 1100 Series Isocratic Pump. Reference Manual

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with an out-in filter.

Agilent 1200 Series Preparative Pump

Installation Guide. Volatiles Interface for 6890 Gas Chromatograph Accessory G2319A

HP Adjustable Depth Fixed Rail Kit Installation

Agilent 1200 Series Capillary Pump

Agilent G5632 Valve Kit Instructions

Agilent G3969A Transfer Line Interface for an Agilent 7697A HS Accessory

TOYOTA SOLARA CONVERTIBLE XM SATELLITE RADIO Preparation. Part Number: Mounting Kit PT

Agilent Valve Kit G4231A/B and G4232A/B/C

E-200 Module Service Kit

Installation Guide. Heater Interface Cable for Mass Sensitive Detector Accessory G1590A

Agilent G2738A Upstream Capillary Interface

260 Solvent Vapor Exit Accessory

Nickel Catalyst Tube on a 6820 GC, Accessory G4318A

Agilent 1200 Series High Performance Autosamplers & Micro Well Plate Autosampler

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

Lamp House with 2.5 kw lamp

Installation Guide. Nitrogen-Phosphorus Detector on 6890 GC Accessories G1575A, G1576A, G1594A, G1599A

Installation Guide Stack Mount Kit for Philips G5 and MP5/20/30/40/50/60/70 Monitor

Service Information. Oil change kit for ZF 8HP automatic transmission

A-dec O Clock Delivery System

Installation Guide. Flame Ionization Detector on a 6890 GC. Accessories G1561A, G1562A, G1591A, G1598A

CAUTION Fuel Lift Pump. Initial Check. Resistance Check.

TOYOTA SIENNA XM SATELLITE RADIO Preparation

M-6642-MB Boss Oil Cooler INSTALLATION INSTRUCTIONS

Tools Needed for Mounting Cleá Filling Station

FlexJet - Flex Cable Replacement

TOYOTA TUNDRA HANDS FREE BLU LOGIC Preparation

Agilent G4236A 2D-LC Valve Installation Guide

Performance Inlet Manifold

Filter. Table of Contents. Section 10. Filter NOTE: This section applies to applicators with a Universal in-out filter.

7.3L Comp Wheel Upgrade F o r d P o w e r s t r o k e 7. 3 L

Installing the Flame Ionization Detector EPC Flow Control Manifold

Installation Instructions

A-dec 351 Assistant s Instrumentation on an A-dec 311/411/511 Dental Chair INSTALLATION GUIDE

Acura TSX 2009-up CH

CLEANING AUTOMATIC TRANSMISSION COMPONENTS

Replacing the Battery in the Patriot SPS 250, SPS 300 and SPS 450

Installing an Auxiliary Pressure Control Module

N/S= Not Shown Bold = Part available for purchase. Italic = Part not available for purchase, listed and shown for reference only.

SCION TC HANDS FREE BLU LOGIC Preparation

Installing the ONS M6 Shelf

Carousel Unit User Manual Replacing the Check Stand Motor

G1160A Agilent 1100 Series Multiple Purpose Switching Valve

DESCRIPTION. Replacement of batteries B ,2. Charging of batteries B ,4. Replacement of motor B ,6

Installation Guide. Flame Ionization Detector on a 6850 GC Accessory G2621

Replacing a Gun RTD. Instruction Sheet P/N B. 1. Introduction. Using this Instruction Sheet

LP Series Label Feeders

TOYOTA COROLLA ILLUMINATED DOOR SILLS Preparation

Volvo P1 Air Intake. ELEVATE Turbo Intake Pipe. MAF Sensor. Inlet Manifold. Air Filter Housing. ECU Cover

Installation Guide. Thermal Conductivity Detector on a 6850 GC Accessory G2623A

3.1 DISPENSER BLACK SHADOW SERIES. Tools Needed for Mounting SCS Dispenser Hammer

E-200 O-rings Service Kit

Upgrading the Sure Coat Modular Gun Control System

Agilent Online-SPE Direct Inject Kit G4744A

ELECRAFT K3 HIGH-PERFORMANCE METER TRANSCEIVER INSTALLING CRYSTAL I.F. FILTERS. Rev A, October 15, 2007

Agilent 1200 Series Binary Pump SL. User Manual

Installation Guide GE Healthcare Carescape Single Display Roll Stand Kit

TOYOTA VENZA HANDS FREE BLU LOGIC Preparation

Installing an H-200 Integral Right-Angle Module

Chevrolet Impala 2014-up* *Visit MetraOnline.com for up-to-date vehicle specific applications. KIT FEATURES

Transcription:

s1 Installation Note for Solvent Selection Valve Upgrade Kit (G1360A) This note describes how to install the solvent selection valve upgrade kit into an Agilent 1100 Series binary pump. General Information The programmable solvent selection valve combines two out of four solvents for binary pump formation or selects a different solvent for flushing the column. It cannot be used as an gradient valve. When installed the solvent selection valve can be activated from the set-up screens of your user interface. For channel A you can select between A1 and A2, for channel B you can select between B1 and B2. Position 1 is the upper connection of the valve, whereas position 2 is lower position of the valve. The valve outlet is the middle position of the solvent selection valve. Copyright Agilent Technologies 2000 1

Delivery Checklist Ensure all parts and materials have been delivered with the upgrade kit. The delivery checklist is shown in Table 1. Please report missing or damaged parts to your local Agilent Technologies sales and service office. Table 1 Solvent Selection Valve Upgrade Kit Description Quantity Part Number Solvent selection valve (SSV) 2 G1312-60000 Screw 2 5022-2112 Cable assembly, solvent selection valve 1 G1312-61602 Connecting tube 2 G1311-67304 Drawing tube 2 G1311-60003 Bottle 2 9301-1421 Figure 1 Solvent Selection Valve Upgrade Kit Drawing tube Cable assembly Screws SSV Bottles Connecting tubes 2

Safety Information Safety Information WARNING The following procedures require opening the main cover of the binary pump. Always make sure the binary pump is disconnected from the line power when the main cover is removed. The security lever at the power input socket prevents that the pump cover is taken off when line power is still connected. WARNING To disconnect the binary pump from line, unplug the power cord. The power supply still uses some power, even if the switch on the front panel is turned off. WARNING When opening capillary or tube fittings solvents may leak out. Please observe appropriate safety procedures (for example, goggles, safety gloves and protective clothing) as described in the material handling and safety data sheet supplied by the solvent vendor, especially when toxic or hazardous solvents are used. NOTE The electronics of the binary pump will not allow operation when the top cover and the top foam are removed. A safety light switch on the main board will inhibit the operation of the binary pump. Always operate the binary pump with the top foam and top covers in place. CAUTION Internal components may be sensitive to electrostatic discharge (ESD). Always use an ESD kit (shipped with the standard accessory kit of your pump) when handling internal parts. 3

Installing the Solvent Selection Valve Upgrade Kit Tools required Screwdriver Pozidriv #1 Wrench 1/4 inch Wrench 14 mm Wrench 7 mm Wrench 5 mm The following procedure concentrates mainly on installation of new parts and gives only basic information about preparation steps, such as top cover removal, and so on. Refer to your Reference Manual in section Repairing Your Pump for detailed descriptions of these procedures. Before beginning this procedure: Switch off binary pump at the main power switch. Disconnect the solvent inlet tube and the adapter at the active inlet valve. Beware of leaking solvents due to hydrostatic flow. Remove the solvent cabinet from the binary pump. 1 Remove front cover, top cover, metal plate and top foam section. Remove the cover plate that covers the position of the solvent selection valve. 2 Disconnect capillaries, tubes and connectors from the two pump heads and the damper. Remove the mixing chamber from its holder. 4

3 Disconnect the connectors of the active inlet valve and the damper from the main board (J19, J24, J28), loosen the Z-panel screws and take out the damper. Remove the Z-panel. 4 Disconnect both pumps from the main board (J16, J17, J12, J27) and lift them out of the foam. 5 Remove the HPM board, for help see Exchanging the HPM Board in your Reference Manual. 6 Push the leak sensor cable through the bottom of the foam and lift the foam out. 5

7 Push the connector plate of the SSV cable assembly into the slit of the bottom foam. 8 Place the cable in the slit of the lower side of the foam and lead it through the hole in the foam. 9 Slide the leak sensor cable through the bottom foam (underneath the newly installed SSV connector plate). Replace the bottom foam and fix the leak sensor cable in the foam. 10 Reinstall the main board and reconnect all cables. The SSV cable will be connected to J30 on the board. 6

11 Slide the SSV block with the two selection valve into its position and fix with the two screws. 12 Replace the two pump units and connect to the main board (J16, J 17, J12, J27). 13 Place Z-panel into its position and replace the damper. Fix the Z-panel and reconnect the cables at the main board (J19, J28, J24). 14 Reconnect all capillaries, tubes and cables to the pump heads and the damper. Fix the mixing chamber in its holder. 7

15 Connect the two connecting tubes between the middle positions of the SSV s and the active inlet valve. 16 Replace top foam, metal plate and top cover. Reinstall the leak funnel with the waste tube and re-locate the waste tube in the holder in the leak pan. On completion of this procedure: 1 Place the binary pump back to its position in the stack, replace the solvent cabinet. Add the two additional bottles with the bottle head assemblies to the cabinet and connect the tubes to the solvent selection valve. 2 Connect the power cables to the pump and turn on the instrument. A1 B1 A2 B2 Copyright Agilent Technologies 2000 Printed in Germany Edition 04/00 Part No. G1360-90101