Check-Q-meter type FD

Similar documents
Double throttle/check valve Type Z2FS B/ (New Series) Huade América 1

Pilot operated check valves, Types SV and SL...40B/ (new series) Huade América 1

RE / Check-Q-meter type FD, series 2X. Ordering details FD 2X / V * Symbols 1/8. Replaces: 03.92

Size 6 10 up to 31.5 MPa up to 120L/min

Directional Control Valves, electrically operated Type WE 5 Huade América 1

Proportional flow control valve 2-way versiontype 2FRE 6...RC

Vickers Counterbalance Valve. CB Series Mainfold Mounting 315 Bar SAE Flange Mounting L/min Subplate Mounting

Size 10 to 32 up to 35 MPa up to 1100 L/min

Proportional Electro-Hydraulic Relif and Flow Control Valves,Type PQ10-20/ Huade América 1

Pressure shut-off valve pilot operated, type DA/DAW...50B/(New Series) Huade América 1

PILOT OPERATED PRESSURE REDUCING VALVE TYPE DR

4/2- and 4/3-way proportional directional valves, direct actuated, without electrical feedback, Type 4WRA. Huade América 1

Pressure relief valves,type DB3U Huade América 1

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

VINCKE INDUSTRIAL HYDRAULIC VALVES INTRODUCTION

Throttle/Isolating and Throttle/Check Valves Type DV/DRV Huade América 1

Size10 to 32 up to 28/35 MPa up to 1100 L/min

Proportional flow control valve 2-way version, Type 2FRE 10, Huade América 1

Rexroth Hydraulics. Pressure reducing valve, pilot operated, type 3DR 3DR 10 P 6X Y 00 RE /10.97

Pilot Operated Directional Control Valves Series D1VP, D3DP, D4P, D9P, D11P

4/2 and 4/3 Proportional Directional Valves Direct Control, Type 4WRE, Series 1X,with electrical feedback. Huade América 1

RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)

Pilot operated check valve

Directional Seat Valve Series D4S (Denison)

Check valve, pilot operated

Chapter 5: Flow Valves

PILOT OPERATED PRESSURE RELIEF VALVE TYPE DB/DBW

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

Pilot operated pressure relief valve

Pressure relief valve, type DB/DBW...30B/

WK /2 WAY CARTRIDGE VALVE TYPE URZS 16 COVER FOR CARTRIDGE VALVE TYPE ULZS 16. size 16 up to 42 MPa 140 dm 3 /min DESCRIPTION OF OPERATION

Proportional pressure reducing valve Types DRE and DREM

Proportional Pressure Relief Valve Series RE*T

Directional Control Valve Series D3W Soft Shift

Throttle Check Valve Series FM

Pressure relief valve, pilot operated

RSP 7-06 R S P FUNCTIONAL DESCRIPTION ORDERING CODE. DIRECTIONAL CONTROL VALVES KE /13 D n 06 p max 32 MPa Q max 80 dm 3 /min

VALVES RANGE FOR OPEN LOOPS T E C H N I C A L C A T A L O G

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Directional Control Valve Series 4D01 (DENISON)

HYDRAULICS VINCKE INDUSTRIAL HYDRAULIC VALVES

Double throttle check valve Type Z2FS 10

DENISON HYDRAULICS High Flow Seat Valve Cartridges CEHFE, C1C

Pressure reducing valve, pilot operated

4/3, 4/2 and 3/2 explosion-proof solenoid directional valve

ISO cartridge valves type LIDD and LIQV Flow control, ISO 7368 sizes 16 63

Pipe burst safety valve

Pump Safety Block Model DBA... / DBAW, Series 1X

Pressure reducing valve, pilot operated Type DR

Pressure sequence valve pilot operated

Proportional Pressure Reducing Valves Series PE*W (Parker), R4R (Denison)

Subplates (AP) and multi-station subplates

Proportional Throttle Valves Series TDL

Flow control valve. Rectifier plate. Type 2FRM5,10,16. Type Z4S5, 10, 16 01/ Sizes 5, 10 and 16 Up to 315 bar Up to 160 L/min

Chapter 6: Check Valves

Check valve, pilot operated

Directional spool valve type WMM 16 hand lever operated

VPP2-04. Functional Description HA /2003. Directly operated pressure relief valves. Replaces HA /2002

RS* /110 ED DOUBLE-ACTING THROTTLE FLOW CONTROL VALVE SERIES 30. Q max (see table of performances) THREADED PORTS CARTRIDGE TYPE

ZRV. Direct Operated Check Valve Series ZRV (Denison)

Pipe burst safety valve Type MHRB

Hydraulics. Axial Piston Pumps Series PVP. Introduction. With thru shaft option for multiple pump options Swash plate type for open circuit

RC /

RE / Central Hydraulics Valve LT43 for Tractors with Priority Function for Steering and Trailer Brake and Pilot Oil Valve.

Proportional Directional Valves pilot operated type 4WRZ, external pilot operated type 4WRH

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

Chapter 6: Check Valves

Pilot-Operated Pressure Relief Valve Series RM

Pressure reducing valve, direct operated, with pressure monitoring

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

2-WAY FLOW CONTROL VALVE TYPE UDRD6

HYDRAULIC PILOT CONTROL UNIT OF SANDWICH PLATE DESIGN

VJL Functional Description. Ordering Code VJL Spare Parts HA /2002. Logical 3-way check valves. Replaces HA /2001

Type of operation Depending on requirement either one or two dry DC-solenoid,

Pressure reducing valve, direct operated

LOGIC ELEMENTS SERIES 10 LC* LP* /103 ED CARTRIDGE VALVES ISO DIN COVERS FOR CARTRIDGE VALVES ND

Pressure relief valve, directly operated

DIRECTIONAL CONTROL VALVES CETOP3

Directional cartridge valve tight on both sides type 2URED6 3

Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Throttle and throttle check valve

29 158/ Proportional Pressure Relief Valve Models DBE and ZDBE, Series 1X. Ordering code DBE 6 1X G24 1/ PSI (315 bar)

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Chapter 7: Sandwich Valves

D4E DIRECT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 41

Chapter 10: Valves for Pipe Mounting

Proportional pressure reducing valve, pilot operated

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

DIRECTIONAL CONTROL VALVES CETOP3

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Proportional pressure reducing valve, 3-way variant, pilot operated

LUDV control block in mono block/sandwich plate design M7-20

p max 350 bar Q max 50 l/min bar bar 50 Ports dimensions: P - port (pressure) T - port (drainage) T - port (drainage) A/B - port l/min

Proportional pressure reducing valve, pilot operated

Pilot-Operated Directional Control Valves Series D3 - D11

Examples 3/2-way valve A T NO: Symbol

Pressure relief valve, pilot operated

Ports. Dr. Breit GmbH Carl-Zeiss-Straße 25 D Heiligenhaus phone-contact:

Chapter 5: Flow Valves

Check Valves, Size Spherical Poppet-type, Screw-in Design Series RKVE l/min, 350 bar (500 bar)

Transcription:

BEIJING HUADE HYDRAULIC INDUSTRIAL GROUP CO.,LTD. Check-Q-meter type FD Size 12,16,25,32 up to 31.5MPa up to 560 L/min RE27551/12.2004 Replaces RE27551/05.2001 Features: - Porting pattern to DIN 24 340, from D,ISO 5781 and CETOP-RP 121H - Pilot operated check valve, leak-free,- The check-q-meter controls the returning flow q V2 in relation to the flow being directed into the opposite side of the actuater q V1. With cylinders the area tratio( q V2 = q V1 ϕ ) has to be taken into account, - By-pass valve, free-flow in opposite direction, - Optional built-in secondary pressure relief valve (only for valve with flange connections). Functional, section Check-Q-meters are used in hydraulic systems to influence the speeds of hydraulic motors and cylinders independent of the load (prevents running away). In addition there is an isolator function for pipe burst safety. The check-q-meter comprises basically of the housing (1), main poppet (2), pilot part (3), pilot spool (4), damping spool (5) and pilot damping (6). QV

Ordering Code FD B / * Nominal size 12 = 12 Nominal size 16 = 16 Nominal size 25 = 25 Nominal size 32 = 32 For manifold mounting (cartridge valve) = K For sub-plate mounting = P For SAE flange connections DBV = F without secondary pressure relief valve = A wit secondary pressure relief valve = B (only for valve wih flange connecotions) Operation pressure of secondary pressure relief valve No code= Mineral oil V= Phospate ester B00 = Without orifice B30 = Orifice 0.30 mm (sizes 12 and 16) B40 = Orifice 0.40 mm (size 25) B60 = Orifice 0.60 mm (size 32) (other orifice diameters on request) B = Technology of Beijing Huade Hydraulic Series 12 (nominal size 12 16 25) = 12 Series 11 (nominal size 32) = 11 (10 to19: unchanged installation and connection dimensions) Symbols Without secondary pressure relief valve With secondary pressure relief valve Valve type: FD 12 KA 12/B30.. FD 16 KA 12/B30.. FD 25 KA 12/B40.. FD 32 KA 11/B60.. Valve type: FD 12 PA 12/B30.. FD 16 PA 12/B30.. FD 25 PA 12/B40.. FD 32 PA 11/B60.. FD 12 FA 12/B30.. FD 16 FA 12/B30.. FD 25 FA 12/B40.. FD 32 FA 11/B60.. Valve type: FD 12 FB 12/B30.. FD 16 FB 12/B30.. FD 25 FB 12/B40.. FD 32 FB 11/B60.. RM

Circuit examples Note: Two check-q-meters cannot be used to control two cylinders which are forced mechanically to move together, as synchronisation and the same pressure cannot be guaranteed in each cylinder. Therefore, the cylinders have to be equipped with two pilot operated check valves, type SL. The check-q-meter is fitted in a common line. In this case, the load pressure must not exceed 20MPa! Characteristic curves (measured at v = 41 mm 2 and t = 50 ) Pressure difference in MPa Size Size Size Size Pressure difference p in relation to flow q v, measured at throttle position: Throttle fully open ( Px = 6 MPa) B to A Pressure difference in MPa Flow in L/min Size Size Size Size Flow in L/min Pressure difference in MPa Flow in L/min Pressure difference p in relation to flow q, measured v over the check valve A to B Technical data (for applications outside these parameters, please consult us!) Operating pressure, ports A, X (MPa) to 31.5 Operating pressure, port B (MPa) to 42 Pilot pressure, port X (flow control range) (MPa) min. 2 to 3.5, max. 31.5 Cracking pressure, A to B (MPa) 0.2 Setting pressure for secondary pressure relief valve (MPa) to 40 Flow (L/min) 80 size12 200 size16 320 size25 560 size32 Area ratio of the pre-opening Pressure fluid temperature range ( ) -30 to +80 Viscosity range (mm 2 /s) 10 to 800 poppet seat area 1 = area of pilot spool 20 Pressure fluid Mineral oil(for NBR seal) or Phospate ester (for FPM seal) RN

Unit dimensions: for SAE flange connections, without secondary pressure relief valve (Dimensions in mm) 1 Control Port 2 Nameplate Position of port A and port B may be arranged as desired,but dot occupy the position of the fixing screw holes Type B1 B2 D1 D2 D3 D4 D5 D6 D7 D8 D9 T1 L1 L2 L3 L4 L5 L6 FD12KA10 48 70 54 46 M42X2 38 34 46 38.6 16 M10 16 39 16 32 15.5 50.6 60 FD16KA10 48 70 54 46 M42X2 38 34 46 38.6 16 M10 16 39 16 32 15.5 50.6 60 FD25KA10 56 80 60 54 M52X2 48 40 60 48.6 25 M12 19 50 19 39 22 65 80 FD32KA10 66 95 72 65 M64X2 58 52 74 58.6 30 M16 23 52 19 40 25 71 85 Type L7 L8 L9 L10 L11 L12 Size Valve fixing screws/tighting torque M A (Nm) Weight FD12KA12 3 78 128 2.75 191 65 12 4-M10 70-10.9 69 2.8kg RD16KA12 3 78 128 2.75 191 65 12 4-M10 70-10.9 69 2.8kg RD25KA12 4 105 182 2.3 253 75 25 4-M12 80-10.9 120 2.8kg RD32KA11 4 115 198 2.3 289 94 32 4-M16 100-10.9 295 7.5kg RO

Unit dimensions: for sub-plate mounting (Dimensions in mm) 11 fixing holes 1 Control port 3 Locating pin 2 Measuring port 4 Name plate 5 O-ring 6 Valve fixing holes(for size 32,6,the other 4) Subplates for:see page 70 NG12 16 G460/01 G460/02 G461/01 G461/02 NG25 G412/01 G412/02 G413/01 G413/02 NG32 G414/01 G414/02 G415/01 G415/02 Required surface finish of mating piece Type B1 B2 B3 H1 H2 H3 L1 L2 FD 12 PA12 66.5 85 70 85 42.5 70 32 7 FD 16 PA12 66.5 85 70 85 42.5 70 32 7 FD 25 PA12 79.5 100 80 100 50 80 39 11 FD 32 PA11 97 120 95 120 60 95 35.5 16.5 Type L3 L4 L5 L6 L7 L8 Weight O-Ring FD 12 PA12-35.5 43 73 65 140 9kg 21.3x2.4 FD 16 PA12-35.5 43 73 65 140 9kg 21.3x2.4 FD 25 PA12-49 60.5 109 75 200 18kg 29.82x2.62 FD 32 PA11 42 67.5 84 119.5 94 215 24kg 38x3 RP

Unit dimensions: for SAE flange connections, without secondary pressure relief valve (Dimensions in mm) 1 Control port 3 Flange fixing screws 5 Optional port B 7 O-ring 2 Measuring port 4 Blanking flange 6 Nameplate Type B1 B2 B3 B4 D1 D2 D3 D4 D5 H1 H2 FD12FA12 50.85 16.5 72 110 42 18 10.5 18 M10 36 72 RD16FA12 50.85 16.5 72 110 42 18 10.5 18 M10 36 72 RD25FA12 57.2 14.5 90 132 50 25 13.5 25 M12 45 90 RD32FA11 66.7 20 105 154 56 30 15 30 M14 50 105 Type L1 L2 L3 L4 L5 L6 T1 T2 Weight O-Ring FD12FA10 39 23.8 105 65 140 78 0.2 15 7kg 25x3.5 FD16FA10 39 23.8 105 65 140 78 0.2 15 7kg 25x3.5 FD25FA10 50 27.8 148 75 200 105 0.2 18 16kg 32.92x3.53 FD32FA10 52 31.6 155 94 215 115 0.2 21 21kg 37.7x3.53 RQ

Unit dimensions: for SAE flange connections, without secondary pressure relief valve (Dimensions in mm) 1 Control port 3 Flange fixing screws 5 Optional port B 7 O-ring 2 Measuring port 4 Blanking flange 6 Nameplate Type B1 B2 B3 B4 B5 D1 D2 D3 D4 D5 D6 D7 H1 H2 FD12 FB12 50.8 49 16.5 72 110 42 18 34 M22x1.5 10.5 18 M10 36 72 FD16 FB12 50.8 49 16.5 72 110 42 18 34 M22x1.5 10.5 18 M10 36 72 FD25 FB12 57.2 78 14.5 90 132 50 25 42 M27x2 13.5 25 M12 45 90 FD32 FB11 66.7 78 20 105 154 56 30 42 M27x2 15 30 M14 50 105 Type H1 L1 L2 L3 L4 L5 L6 L7 L8 T1 T2 T3 Weight O-Ring FD12 FB12 118 39 23.8 105 141.5 65 162 38 78 0.2 1 15 9Kg 25x3.5 FD16 FB12 118 39 23.8 105 141.5 65 162 38 78 0.2 1 15 9Kg 25x3.5 FD25 FB12 145 50 27.8 148 198 75 225 50 105 0.2 1 18 18Kg 32.92x3.353 FD32 FB11 145 52 31.6 155 215 94 240 50 115 0.2 1 21 24Kg 37.7x3.53 RR

Notice 1. The fluid must be filtered. Minimum filter fineness is 20 µm. 2. The tank must be sealing up and an air filter must be installed on air entrance. 3. Products without subplate when leaving factory, if need them, please ordering specially. 4. Valve fixing screws must be high intensity level (class 10.9). Please select and use them according to the parameter listed in the sample book. 5. Roughness of surface linked with the valve is required to. 6. Surface finish of mating piece is required to 0.01/100mm. RS All rights reserved-subject to revision