PRESSURE FILTER Series HPV 60-150 DN 25 PN 420 Sheet No. 1478 E 1. Type index: 1.1. Complete filter: (ordering example) HPV. 90. 10VG. HR. E. P. -. G. 5. -. D2. AE 1 2 3 4 5 6 7 8 9 10 11 12 HPV = pressure filter with differential pressure-valve 2 nominal size: 60, 90, 150 3 filter-material and filter-fineness: 80 G = 80 m, 40 G = 40 m, 25 G = 25 m stainless steel wire mesh 25 VG = 20 m (c), 16 VG = 15 m (c), 10 VG = 10 m (c), 6 VG = 7 m (c), 3 VG = 5 m (c) Interpor fleece (glass fibre) 4 resistance of pressure difference for filter element: 30 = p 30 bar HR = p 160 bar (rupture strength p 250 bar) 5 filter element design: E = single-end open 6 sealing material: P = Nitrile (NBR) V = Viton (FPM) 7 filter element specification: VA = stainless steel 8 connection: G = thread connection according to ISO 228 9 connection size: 5 = G 1 10 filter housing specification: 11 internal valve: D1 = differential pressure-valve p 3,5 bar D2 = differential pressure-valve p 7,0 bar 12 clogging or : - = without AOR = visual, see sheet-no. 1606 AOC = visual, see sheet-no. 1606 AE = visual-electrical, see sheet-no. 1615 VS1 = electronical, see sheet-no. 1617 VS2 = electronical, see sheet-no. 1618 1.2. Filter element: (ordering example) 01E. 90. 10VG. HR. E. P. - 1 2 3 4 5 6 7 01E. = filter element according to INTERNORMEN specification 2 nominal size: 60, 90, 150 3-7 see type index-complete filter 1) connection for the potential equalisation, only for application in the explosive area 2. Dimensions: type HPV 60 HPV 90 HPV 150 connection G 1 A 237 302 411 B 178 243 352 C 270 335 445 weight kg 6,5 7 8 volume tank 0,3 l 0,4 l 0,6 l EDV 04/11 Changes of measures and design are subject to alteration! Friedensstrasse 41, 68804 Altlussheim, Germany phone fax +49 - (0)6205-2094-0 +49 - (0)6205-2094-40 e-mail url sales@internormen.com www.internormen.com
3. Spare parts: item qty. designation dimension article-no. HPV 60-150 1 1 filter element 01E. 60-150 2 1 O-ring 22 x 3,5 304341 (NBR) 304392 (FPM) 3 1 O-ring 54 x 3 304657 (NBR) 304720 (FPM) 4 1 support ring 61 x 2,6 x 1 304660 5 1 screw plug G ½ 304678 6 1 clogging, visual AOR or AOC see sheet-no. 1606 7 1 clogging, visual-electrical AE see sheet-no. 1615 8 1, electronical VS1 see sheet-no. 1617 9 1, electronical VS2 see sheet-no. 1618 10 1 O-ring 15 x 1,5 315357 (NBR) 315427 (FPM) 11 O-ring 22 x 2 304708 (NBR) 304721 (FPM) 12 1 O-ring 14 x 2 304342 (NBR) 304722 (FPM) 13 1 screw plug 20913-4 309817 item 13 execution only without clogging or 4. Description: The pressure filters of the series HPV 60-150 are suitable for a working pressure up to 420 bar. The pressure peaks are absorbed by a sufficient margin of safety. The HPV-filter is in-line mounted. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside. Filter elements are available down to 4µm (c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available up to a pressure difference resistance of p 160 bar and a rupture strength of p 250 bar. The differential pressure-valve opens independently of the operating pressure at a chosen differential pressure-valve between IN and OUT and leaves an unfiltered partial-flow flowing from IN to the tank. 5. Technical data: temperature range: - 10 C to + 80 C (for a short time + 100 C) operating medium: mineral oil, other media on request max. operating pressure: 420 bar test pressure: 600 bar connection system: thread connection according to ISO 228 housing material: C-steel sealing material: Nitrile (NBR) or Viton (FPM), other materials on request installation position: vertical Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). 6. Symbols: without with electrical AE 30 and AE 40 AE 50 and AE 62 AE 70 and AE 80 with visual AOR/AOC VS1 VS2 7. Pressure drop flow curves: Precise flow rates see INT-Expert-System Filter respectively p-curves ; depending on filter fineness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 Verification of collapse/burst resistance ISO 2942 Verification of fabrication integrity ISO 2943 Verification of material compatibility with fluids ISO 3723 Method for end load test ISO 3724 Verification of flow fatigue characteristics ISO 3968 Evaluation of pressure drop versus flow characteristics ISO 16889 Multi-pass method for evaluating filtration performance E 1478 E
PRESSURE FILTER Series HPV 170-450 DN 25-40 PN 420 Sheet No. 1479 D 1. Type index: 1.1. Complete filter: (ordering example) HPV. 360. 10VG. HR. E. P. -. G. 7. -. D2. AE 1 2 3 4 5 6 7 8 9 10 11 12 HPV = pressure filter with differential pressure-valve 2 nominal size: 170, 240, 360, 450 3 filter-material and filter-fineness: 80 G = 80 m, 40 G = 40 m, 25 G = 25 m stainless steel wire mesh 25 VG = 20 m (c), 16 VG = 15 m (c), 10 VG = 10 m (c), 6 VG = 7 m (c), 3 VG = 5 m (c) Interpor fleece (glass fibre) 4 resistance of pressure difference for filter element: 30 = p 30 bar HR = p 160 bar (rupture strength p 250 bar) 5 filter element design: E = single-end open 6 sealing material: P = Nitrile (NBR) V = Viton (FPM) 7 filter element specification: VA = stainless steel 8 connection: G = thread according to ISO 228 9 connection size: 5 = G 1 6 = G 1 ¼ 7 = G 1 ½ 10 filter housing specification: 11 internal valve: D1 = differential pressure-valve p 3,5 bar D2 = differential pressure-valve p 7,0 bar 12 clogging or : - = without AOR = visual, see sheet-no. 1606 AOC = visual, see sheet-no. 1606 AE = visual-electrical, see sheet-no. 1615 VS1 = electronical, see sheet-no. 1617 VS2 = electronical, see sheet-no. 1618 1.2. Filter element: (ordering example) 01E. 360. 10VG. HR. E. P. - 1 2 3 4 5 6 7 01E. = filter element according to INTERNORMEN specification 2 nominal size: 170, 240, 360, 450 3-7 see type index-complete filter 2. Dimensions: type HPV 170 HPV 240 HPV 360 HPV 450 connection G 1 G 1 ¼ G 1 ½ G 1 G 1 ¼ G 1 ½ G 1 G 1 ¼ G 1 ½ G 1 G 1 ¼ G 1 ½ A 337 337 342 387 387 392 467 467 472 572 572 577 B 263 263 265 313 313 315 393 393 395 498 498 500 C 350 350 350 400 400 400 480 480 480 585 585 585 D 74 74 77 74 74 77 74 74 77 74 74 77 E 73 73 75 73 73 75 73 73 75 73 73 75 F 46 57 63,5 46 57 63,5 46 57 63,5 46 57 63,5 weight kg 13,5 14,5 14,9 14,8 15,8 16,2 16,7 17,7 18,1 19,2 20,2 20,6 volume tank 0,7 l 0,9 l 1,2 l 1,6 l EDV 04/11 1) connection for the potential equalisation, only for application in the explosive area Friedensstrasse 41, 68804 Altlussheim, Germany phone fax +49 - (0)6205-2094-0 +49 - (0)6205-2094-40 Changes of measures and design are subject to alteration! e-mail url sales@internormen.com www.internormen.com
3. Spare parts: item qty. designation dimension article-no. HPV 170-450 1 1 filter element 01E. 170-450 2 1 O-ring 34 x 3,5 304338 (NBR) 304730 (FPM) 3 1 O-ring 75 x 3 302215 (NBR) 304729 (FPM) 4 1 support ring 81 x 2,6 x 1 304581 5 1 screw plug G ¾ 308529 6 1 clogging, visual AOR or AOC see sheet-no. 1606 7 1 clogging, visual-electrical AE see sheet-no. 1615 8 1, electronical VS1 see sheet-no. 1617 9 1, electronical VS2 see sheet-no. 1618 10 1 O-ring 15 x 1,5 315357 (NBR) 315427 (FPM) 11 O-ring 22 x 2 304708 (NBR) 304721 (FPM) 12 1 O-ring 14 x 2 304342 (NBR) 304722 (FPM) 13 1 screw plug 20913-4 309817 item 13 execution only without clogging or 4. Description: The pressure filters of the series HPV 170-450 are suitable for a working pressure up to 420 bar. The pressure peaks are absorbed by a sufficient margin of safety. The HPV-filter is in-line mounted. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside. Filter elements are available down to 4µm (c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available up to a pressure difference resistance of p 160 bar and a rupture strength of p 250 bar. The differential pressure-valve opens independently of the operating pressure at a chosen differential pressure-valve between IN and OUT and leaves an unfiltered partial-flow flowing from IN to the tank. 5. Technical data: temperature range: - 10 C to + 80 C (for a short time + 100 C) operating medium: mineral oil, other media on request max. operating pressure: 420 bar test pressure: 600 bar connection system: thread according to ISO 228 housing material: C-steel sealing material: Nitrile (NBR) or Viton (FPM), other materials on request installation position: vertical Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). 6. Symbols: without with electrical AE 30 and AE 40 AE 50 and AE 62 AE 70 and AE 80 with visual AOR/AOC VS1 VS2 7. Pressure drop flow curves: Precise flow rates see INT-Expert-System Filter respectively p-curves ; depending on filter fineness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 Verification of collapse/burst resistance ISO 2942 Verification of fabrication integrity ISO 2943 Verification of material compatibility with fluids ISO 3723 Method for end load test ISO 3724 Verification of flow fatigue characteristics ISO 3968 Evaluation of pressure drop versus flow characteristics ISO 16889 Multi-pass method for evaluating filtration performance E 1479 D
PRESSURE FILTER Series MDV 40-63 DN 15-20 PN 200 Sheet No. 1419 C 1. Type index: 1.1. Complete filter: (ordering example) MDV. 40. 10VG. HR. E. P. -. G. 3. -. D2. AE 1 2 3 4 5 6 7 8 9 10 11 12 MDV = medium pressure filter with differential pressure-valve 2 nominal size: 40, 63 3 filter-material and filter-fineness: 25 VG = 20 µm (c), 16 VG = 15 µm (c), 10 VG = 10 µm (c), 6 VG = 7 µm (c), 3 VG = 5 µm (c) Interpor fleece (glass fibre) 4 resistance of pressure difference for filter element: 30 = p 30 bar HR = p 160 bar (rupture strength p 250 bar) 5 filter element design: E = single-end open 6 sealing material: P = Nitrile (NBR) V = Viton (FPM) 7 filter element specification: VA = stainless steel 8 connection: G = thread connection according to ISO 228 9 connection size: 3 = G ½ 4 = G ¾ 10 filter housing specification: 11 internal valve: D1 = differential pressure-valve p 3,5 bar D2 = differential pressure-valve p 7,0 bar 12 clogging or : - = without AOR = visual, see sheet-no. 1606 AOC = visual, see sheet-no. 1606 AE = visual-electrical, see sheet-no. 1615 VS1 = electronical, see sheet-no. 1617 VS2 = electronical, see sheet-no. 1618 1.2. Filter element: (ordering example) 01NL. 40. 10VG. HR. E. P. - 1 2 3 4 5 6 7 01NL. = standard filter element according to DIN 24550, T3 2 nominal size: 40, 63 3-7 see type index-complete filter 2. Dimensions: type connection A B C D weight kg volume tank MDV 40 G ½ 211 157 265 30 2,7 0,25 l MDV 63 G ¾ 271 217 325 36,5 3,2 0,35 l Connection assignments as shown in the table are standard according to DIN 24 550 T1. Are the connection assignments against DIN 24 550 T1, see item 9 of the type code. EDV 11/07 Changes of measures and design are subject to alteration! Friedensstrasse 41, 68804 Altlussheim, Germany phone fax +49 - (0)6205-2094-0 +49 - (0)6205-2094-40 e-mail url sales@internormen.com www.internormen.com
3. Spare parts: item qty. designation dimension article-no. MDV 40 MDV 63 1 1 filter element 01NL.40 01NL.63 2 1 O-ring 22 x 3,5 304341 (NBR) 304392 (FPM) 3 1 O-ring 54 x 3 304657 (NBR) 304720 (FPM) 4 1 support ring 60 x 2,6 x 1 311779 5 1 screw plug G ½ 304678 6 1 clogging visual AOR or AOC see sheet-no. 1606 7 1 clogging visual-electrical AE see sheet-no. 1615 8 1 electronical VS1 see sheet-no. 1617 9 1 electronical VS2 see sheet-no. 1618 10 1 O-ring 15 x 1,5 315357 (NBR) 315427 (FPM) 11 1 O-ring 22 x 2 304708 (NBR) 304721 (FPM) 12 1 O-ring 14 x 2 304342 (NBR) 304722 (FPM) 13 1 screw plug 20913-4 309817 item 13 execution only without clogging or 4. Description: The pressure filters of the series MDV are suitable for a working pressure up to 200 bar and equiped with elements according to DIN 24 550 T3. The pressure peaks are absorbed by a sufficient margin of safety. The MDV-filter is in-line mounted. The filter element consists of star-shaped, pleated filter material which is supported on the inside by a perforated core tube and is bonded to the end caps with a high-quality adhesive. The flow direction is from outside to the inside. Filter elements are available down to 4µm (c). INTERNORMEN-Filter elements are known as elements with a high intrinsic stability and an excellent filtration capability, a high dirtretaining capacity and a long service life. INTERNORMEN-Filter are suitable for all petroleum based fluids, HW-emulsions, most synthetic hydraulic fluids and lubrication oils. INTERNORMEN-Filter elements are available up to a pressure difference resistance of p 160 bar and a rupture strength of p 250 bar. The differential pressure-valve opens independently of the operating pressure at a chosen differential pressure-valve between IN and OUT and leaves an unfiltered partial-flow flowing from IN to the tank. 5. Technical data: temperature range: - 10 C to + 80 C (for a short time + 100 C) operating medium: mineral oil, other media on request max. operating pressure: 200 bar test pressure: 260 bar connection system: thread connection according to ISO 228 housing material: aluminium forging alloy; C-steel sealing material: Nitrile (NBR) or Viton (FPM), other materials on request installation position: vertical Classified under the Pressure Equipment Directive 97/23/EC for mineral oil (fluid group 2), Article 3, Para. 3. Classified under ATEX Directive 94/9/EC according to specific application (see questionnaire sheet-no. 34279-4). 6. Symbols: without with electrical AE 30 and AE 40 AE 50 and AE 62 AE 70 and AE 80 with visual AOR/AOC VS1 VS2 7. Pressure drop flow curves: Precise flow rates see INT-Expert-System Filter respectively p-curves ; depending on filter fineness and viscosity. 8. Test methods: Filter elements are tested according to the following ISO standards: ISO 2941 Verification of collapse/burst resistance ISO 2942 Verification of fabrication integrity ISO 2943 Verification of material compatibility with fluids ISO 3723 Method for end load test ISO 3724 Verification of flow fatigue characteristics ISO 3968 Evaluation of pressure drop versus flow characteristics ISO 16889 Multi-pass method for evaluating filtration performance E 1419 C