Model: 180REOZJD 208-600 V Diesel Ratings Range 60 Hz Standby: kw 145--180 kva 181--225 Prime: kw 135--165 kva 169--206 Standard Features Kohler Co. provides one-source responsibility for the generating system and accessories. The generator set and its components are prototype-tested, factory-built, and production-tested. The 60 Hz generator set offers a UL 2200 listing. The generator set accepts rated load in one step. The 60 Hz generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards. The generator set complies with ISO 8528-5, Class G2, requirements for transient performance in all generator set configurations. Select the Decision-Maker 550 controller for improved voltage regulation and ISO 8528-5, Class G3, compliance. The 60 Hz generator set engine is certified by the Environmental Protection Agency (EPA) to conform to Tier 3 nonroad emissions regulations. A one-year limited warranty covers all systems and components. Two-, five-, and ten-year extended warranties are also available. Alternator features: The unique Fast-Response II excitation system delivers excellent voltage response and short circuit capability using a permanent magnet (PM)-excited alternator. The brushless, rotating-field alternator has broadrange reconnectability. Other features: Controllers are available for all applications. See controller features inside. The low coolant level shutdown prevents overheating (standard on radiator models only). Integral vibration isolation eliminates the need for under-unit vibration spring isolators. Generator Set Ratings 130 C Rise Standby Rating 105 C Rise Prime Rating Alternator Voltage Ph Hz kw/kva Amps kw/kva Amps 4S15 120/208 3 60 180/225 625 165/206 573 127/220 3 60 180/225 590 165/206 541 120/240 3 60 150/188 452 140/175 421 139/240 3 60 180/225 541 165/206 496 220/380 3 60 145/181 275 135/169 256 277/480 3 60 180/225 271 165/206 248 347/600 3 60 180/225 217 165/206 198 RATINGS: All three-phase units are rated at 0.8 power factor. All single-phase units are rated at 1.0 power factor. Standby Ratings: Standby ratings apply to installations served by a reliable utility source. The standbyratingisapplicabletovaryingloadsforthedurationofapoweroutage. Thereisnooverloadcapabilityforthisrating. RatingsareinaccordancewithISO-3046/1, BS5514, AS2789, anddin 6271. Prime Power Ratings: Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528/1, overload power in accordance with ISO-3046/1, BS 5514, AS 2789, and DIN 6271. For limited running time and base load ratings, consult the factory. Obtain the technical information bulletin (TIB-101) on ratings guidelines for the complete ratings definitions. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. GENERAL GUIDELINES FOR DERATION: Altitude: Derate 0.5% per 100 m (328 ft.) elevation above 1000 m (3300 ft.). Temperature: Derate 1.0% per 10 C (18 F) temperature above 25 C (77 F). G5-288 (180REOZJD) 9/08f
Specifications Manufacturer Type Exciter type Leads: quantity, type Voltage regulator Insulation: Material Temperature rise Bearing: quantity, type Coupling Amortisseur windings Voltage regulation, no-load to full-load Permanent magnet (PM) alternator Alternator Kohler Alternator Specifications 4-Pole, Rotating-Field Brushless, Permanent-Magnet 12, Reconnectable Solid State, Volts/Hz NEMA MG1 Class H 130 C, Standby 1, Sealed Flexible Disc Full ±2% Average 550 controller (with 0.5% drift due to temperature variation) 3-Phase Sensing, ±0.25% Unbalanced load capability 100% of Rated Standby Current One-step load acceptance 100% of Rating Peak motor starting kva: (35% dip for voltages below) 480 V 4S15 (12 lead) 620 Engine Engine Specifications Manufacturer John Deere Engine model 6068HF485 Engine type 4-Cycle, Turbocharged, Charge Air-Cooled Cylinder arrangement 6 Inline Displacement, L (cu. in.) 6.79 (414) Bore and stroke, 106 x 127 (4.19 x 5.00) Compression ratio 17.0:1 Piston speed, m/min. (ft./min.) 457 (1500) Main bearings: quantity, type 7, Replaceable Insert Rated rpm 1800 Max. power at rated rpm, kwm (BHP) 235 (315) Cylinder head material Cast Iron Crankshaft material Forged Steel Valve material: Intake Chromium-Silicon Steel Exhaust Stainless Steel Governor: type, make/model JDEC Electronic L14 Denso HP3 Frequency regulation, no-load to full-load Isochronous Frequency regulation, steady state ±0.25% Frequency Fixed Air cleaner type, all models Dry Application Data NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting. Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds. Sustained short-circuit current enabling downstream circuit breakers to trip without collapsing the alternator field. Self-ventilated and dripproof construction. Vacuum-impregnated windings with fungus-resistant epoxy varnish for dependability and long life. Fast-Response II brushless alternator with brushless exciter for excellent load response. Exhaust Exhaust System Exhaust manifold type Dry Exhaust flow at rated kw, m 3 /min. (cfm) 42.8 (1510) Exhaust temperature at rated kw, dry exhaust, C ( F) 527 (980) Maximum allowable back pressure, kpa (in. Hg) Min. 4 (1.2) Max. 10 (3.0) Exhaust outlet size at engine hookup, 98 (3.86) Engine Electrical Engine Electrical System Battery charging alternator: 24 Volt Ground (negative/positive) Negative Volts (DC) 24 Ampere rating 45 Starter motor rated voltage (DC) 24 Battery, recommended cold cranking amps (CCA): Quantity, CCA rating each Two, 950 Battery voltage (DC) 12 G5-288 (180REOZJD) 9/08f
Fuel Fuel System Fuel supply line, min. ID, 11.0 (0.44) Fuel return line, min. ID, 6.0 (0.25) Max. lift, fuel pump: type, m (ft.) Electronic, 1.8 (6.0) Max. fuel flow, Lph (gph) 92.7 (24.5) Fuel prime pump Manual Fuel filter Secondary 2 Microns @ 98% Efficiency Primary 30 Microns Water Separator Yes Recommended fuel #2 Diesel Lubrication Application Data Fuel Consumption Diesel, Lph (gph) at % load Standby Rating 100% 51.5 (13.6) 75% 39.3 (10.4) 50% 27.5 (7.3) 25% 15.8 (4.2) Diesel, Lph (gph) at % load Prime Rating 100% 46.9 (12.4) 75% 36.3 (9.6) 50% 25.5 (6.7) 25% 14.8 (3.9) Lubricating System Type Full Pressure Oil pan capacity, L (qt.) 32.5 (34.4) Oil pan capacity with filter, L (qt.) 33.4 (35.3) Oil filter: quantity, type 1, Cartridge Oil cooler Water-Cooled Cooling Radiator System Ambient temperature, C ( F) 50 (122) Engine jacket water capacity, L (gal.) 11.3 (3.0) Radiator system capacity, including engine, L (gal.) 27.6 (7.3) Engine jacket water flow, Lpm (gpm) 230.9 (61) Heat rejected to cooling water at rated kw, dry exhaust, kw (Btu/min.) 85.8 (4880) Heat rejected to air charge cooler at rated kw, dry exhaust, kw (Btu/min.) 66.6 (3790) Water pump type Centrifugal Fan diameter, including blades, 787 (31) Fan, kwm (HP) 8.6 (11.5) Max. restriction of cooling air, intake and discharge side of radiator, kpa (in. H 2 O) 0.125 (0.5) Operation Requirements Air Requirements Radiator-cooled cooling air, m 3 /min. (scfm) 368.1 (13000) Combustion air, m 3 /min. (cfm) 15.9 (560) Heat rejected to ambient air: Engine, kw (Btu/min.) 41.8 (2380) Alternator, kw (Btu/min.) 14.4 (820) Air density = 1.20 kg/m 3 (0.075 lbm/ft 3 ) Controllers Decision-Maker 550 Controller Audiovisual annunciation with NFPA 110 Level 1 capability. Programmable microprocessor logic and digital display features. Alternator safeguard circuit protection. 12- or 24-volt engine electrical system capability. Remote start, remote annunciation, and remote communication options. Refer to G6-46 for additional controller features and accessories. Decision-Maker 3+, 16-Light Controller Audiovisual annunciation with NFPA 110 Level 1 capability. Microprocessor logic, AC meters, and engine gauge features. 12- or 24-volt engine electrical system capability. Remote start, prime power, and remote annunciation options. Refer to G6-30 for additional controller features and accessories. G5-288 (180REOZJD) 9/08f
KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-565-3381, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KohlerPower.com Additional Standard Features Alternator Protection (standard with 550 controller) Battery Rack and Cables Emission Compliant Engine Integral Vibration Isolation Oil Drain Extension Operation and Installation Literature Available Options Approvals and Listings CSA Approval IBC Seismic Certification UL 2200 Listing Enclosed Unit Sound Enclosure (with enclosed critical silencer) Weather Enclosure (with enclosed critical silencer) Weather Housing (with roof-mounted critical silencer) Open Unit Exhaust Silencer, Critical (kit: PA-354809) Exhaust Silencer, Hospital (kit: PA-365349) Flexible Exhaust Connector, Stainless Steel Fuel System Auxiliary Fuel Pump Flexible Fuel Lines Fuel Pressure Gauge Subbase Fuel Tanks Subbase Fuel Tank with Day Tank Controller Common Failure Relay Communication Products and PC Software (550 controller only) Customer Connection Dry Contact (isolated alarm) Prime Power Switch (550 controller only) Remote Annunciator Panel Remote Audiovisual Alarm Panel Remote Emergency Stop Remote Mounting Cable Run Relay Cooling System Block Heater (recommended for ambient temperatures below 0 C [32 F]) Radiator Duct Flange Electrical System Alternator Strip Heater Battery Battery Charger, Equalize/Float Type Battery Heater Line Circuit Breaker (NEMA type 1 enclosure) Line Circuit Breaker with Shunt Trip (NEMA type 1 enclosure) Safeguard Breaker (16-light controller) Paralleling System Reactive Droop Compensator Voltage Adjust Control Voltage Regulator Relocation Miscellaneous Air Cleaner, Heavy Duty Air Cleaner Restriction Indicator Crankcase Emissions Canister Engine Fluids (oil and coolent) Added Rated Power Factor Testing Rodent Guards Skid End Caps Literature General Maintenance NFPA 110 Overhaul Production Warranty 2-Year Basic 2-Year Prime 5-Year Basic 5-Year Comprehensive 10-Year Major Components Dimensions and Weights Overall Size, L x W x H, : 2975 x 1250 x 1692 (117.13 x 49.21 x 66.62) Weight (radiator model), wet, kg (lb.): 1542.2 (3400) W NOTE: This drawing is provided for reference only and should not be used for planning installation. Contact your local distributor for more detailed information. DISTRIBUTED BY: H Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 Other Options L 2006, 2007, 2008 by Kohler Co. All rights reserved. G5-288 (180REOZJD) 9/08f
Industrial Generator Set Accessories Subbase Diesel Fuel Tanks Double-Wall Subbase Tank, Type 1 Double-Wall Subbase Tank, Type 2 Double-Wall Subbase Tank with Available Weather Enclosure Accessory Double-Wall Subbase Fuel Tanks Applicable to the following: 20ROZJB 20-230REOZJB 80-200REOZJC 80-275REOZJD Secondary Containment (SC) Tank The above-ground rectangular secondary containment tank mounts directly to the generator set, below the generator set skid (subbase). The secondary containment generator set base tank meets UL 142 requirements. Both the inner and outer tanks have emergency relief vents. The containment tank s double-wall construction protects against fuel leaks or ruptures. The inner (primary) tank is sealed inside the outer (secondary) tank. The outer tank contains the fuel if the inner tank leaks or ruptures. The generator set is designed to comply with the installation standards of NFPA 30 and NFPA 37. Standard Features Heavy-gauge construction Integral stub-up area Removable end channel for easy access to stub-up area Emergency pressure-relief vent inner and outer tanks Lockable fill cap and riser, 2 in. NPT Low fuel level switch for controller alarm (optional with Decision-Maker 1 controller) Mechanical fuel gauge Normal vent with riser and mushroom cap Fuel supply and fuel return openings Basin drain Float fitting for pump control for fuel transfer system model Overflow opening for fuel transfer system model G6-67 8/08j Page 1
Fuel Tank Features 1 ADV-6912A-A 4 3 2 1. Inner tank leak alarm kit 2. Fuel tank fittings and components (see Figure 2 for details) 3. Emergency pressure relief vent inner tank 4. 1/2 in. NPT for leak detection switch Figure 1 Double-Wall Subbase Fuel Tanks (Secondary Containment) 1. Emergency vent per NFPA 30 2 in. NPT 227--382 L (60--101 gal.) 3 in. NPT 413--1083 L (109--286 gal.) 4 in. NPT 1124--1874, 2347 L (297--495, 620 gal.) 5 in. NPT 2207, 2249, 2559--5526 L (583, 594, 676--1460 gal.) 2. 2 in. NPT raised manual fill cap with 51 mm (2 in.) riser 3. 2 in. NPT level gauge 4. 1 1/4 in. NPT normal vent with 127 mm (5 in.) riser and mushroom cap 5. 3/8 in. diptube with check valve, 3/8 in. NPT (female) customer fuel supply connection 6. 3/8 in. diptube, 3/8 in. NPT (female) customer fuel return connection 7. 2 in. NPT with low level switch 8. 2 in. NPT for sensor/pump control float 9. 1 in. NPT for overflow, 7.6 L (2 gpm) pump maximum 10. 1 in. NPT for tank fill Note: Items 2 and 3 are reversed on 864 mm (34 in.) width fuel tanks ADV-6912A-A Figure 2 Fuel Tank Fittings Top View (Figure 1, Item 2) G6-67 8/08j Page 2
Fuel Tank Accessories Inner tank leak alarm kit (see Figure 1) Low fuel alarm (Decision-Maker 1 controller only) High fuel level alarm switch (90% full) Above ground 19 L (5 gal.) fill/spill container with 39.4 m (12 ft.) normal vent riser and diptube for fuel overfill spills during fill up; external mount only with weather/sound enclosure with internal silencer (see Figure 3 or Figure 4) 1 1 2 2 3 3 ADV-7322D- ADV-7020D- 1. Vent 2. Spill tank, 18.9 L (5 gal.) 3. Drain, 1/2 in. NPT 1. Vent 2. Spill tank, 18.9 L (5 gal.) 3. Drain, 1/2 in. NPT Figure 3 Fill/Spill Container, 20--125 kw Figure 4 Fill/Spill Container, 135--275 kw G6-67 8/08j Page 3
Fuel Tank Weights and Dimensions Fuel Tanks for Open and Enclosed Generator Sets with 1040 mm (41 in.) and 1250 mm (49 in.) Skids Note: All fuel tanks are Type 1 (see page 1 for an illustration) kw 20REOZJB 20ROZJB 30REOZJB 40REOZJB 50REOZJB 60REOZJB 80REOZJB 80REOZJC 80REOZJD 100REOZJB 100REOZJC Kit No. Capacity, L (gal.) Length, Width, Height, Weight, kg (lb.) Est. Fuel Supply, Hours at 60 Hz with Full Load GM32625-KP1/KA1 291 (77) 305 (12) 316 (696) 33 GM32625-KP2/KA2 450 (119) 457 (18) 382 (843) 51 2000 (78.74) GM32625-KP3/KA3 613 (162) 610 (24) 449 (989) 70 GM32625-KP4/KA4 772 (204) 762 (30) 515 (1136) 88 GM32625-KP1/KA1 291 (77) 305 (12) 316 (696) 33 GM32625-KP2/KA2 450 (119) 457 (18) 382 (843) 51 2000 (78.74) GM32625-KP3/KA3 613 (162) 610 (24) 449 (989) 70 GM32625-KP4/KA4 772 (204) 762 (30) 515 (1136) 88 GM32625-KP1/KA1 291 (77) 305 (12) 316 (696) 25 GM32625-KP2/KA2 450 (119) 457 (18) 382 (843) 39 2000 (78.74) GM32625-KP3/KA3 613 (162) 610 (24) 449 (989) 53 GM32625-KP5/KA5 935 (247) 582 (1283) 81 GM32625-KP1/KA1 291 (77) 305 (12) 316 (696) 22 GM32625-KP2/KA2 450 (119) 457 (18) 382 (843) 34 GM32625-KP3/KA3 613 (162) 2000 (78.74) 610 (24) 449 (989) 46 GM32625-KP4/KA4 772 (204) 762 (30) 515 (1136) 58 GM32625-KP5/KA5 935 (247) 582 (1283) 72 GM32625-KP6/KA6 337 (89) 305 (12) 345 (761) 21 GM32625-KP7/KA7 522 (138) 457 (18) 416 (917) 32 2200 (86.61) GM32625-KP8/KA8 712 (188) 610 (24) 486 (1072) 44 GM32625-KP9/KA9 897 (237) 557 (1228) 55 762 (30) GM32625-KP19/KA19 1272 (336) 2800 (110.24) 683 (1505) 78 GM32625-KP6/KA6 337 (89) 305 (12) 345 (761) 17 GM32625-KP7/KA7 522 (138) 457 (18) 416 (917) 27 2200 (86.61) GM32625-KP8/KA8 712 (188) 610 (24) 486 (1072) 36 GM32625-KP10/KA10 1083 (286) 628 (1384) 56 GM32625-KP17/KA17 1499 (396) 2800 (110.24) 761 (1678) 77 GM32625-KP6/KA6 337 (89) 305 (12) 345 (761) 13 GM32625-KP8/KA8 712 (188) 2200 (86.61) 610 (24) 486 (1072) 28 GM32625-KP9/KA9 897 (237) 557 (1228) 35 762 (30) GM32625-KP19/KA19 1272 (336) 2800 (110.24) 683 (1505) 49 GM32625-KP21/KA21 1874 (495) 3302 (130.00) 877 (1934) 73 GM32625-KP11/KA11 382 (101) 305 (12) 375 (826) 13 GM32625-KP12/KA12 810 (214) 2400 (94.49) 610 (24) 524 (1156) 28 GM32625-KP13/KA13 1234 (326) 674 (1485) 43 GM32625-KP17/KA17 1499 (396) 2800 (110.24) 761 (1678) 52 GM32625-KP22/KA22 2249 (594) 3810 (150.00) 993 (2190) 78 GM32625-KP11/KA11 382 (101) 305 (12) 375 (826) 14 GM32625-KP12/KA12 810 (214) 2400 (94.49) 610 (24) 524 (1156) 31 GM32625-KP13/KA13 1234 (326) 674 (1485) 47 GM32625-KP17/KA17 1499 (396) 2800 (110.24) 761 (1678) 57 GM32625-KP22/KA22 2249 (594) 3810 (150.00) 993 (2190) 86 GM32625-KP14/KA14 432 (114) 305 (12) 404 (891) 14 GM32625-KP15/KA15 908 (240) 2600 (102.36) 610 (24) 562 (1239) 29 GM32625-KP16/KA16 1385 (366) 720 (1587) 44 GM32625-KP21/KA21 1874 (495) 3302 (130.00) 877 (1934) 59 GM32625-KP23/KA23 2627 (694) 4318 (170.00) 1109 (2446) 83 GM32625-KP11/KA11 382 (101) 305 (12) 375 (826) 12 GM32625-KP12/KA12 810 (214) 2400 (94.49) 610 (24) 524 (1156) 26 GM32625-KP13/KA13 1234 (326) 674 (1485) 40 GM32625-KP17/KA17 1499 (396) 2800 (110.24) 761 (1678) 49 GM32625-KP22/KA22 2249 (594) 3810 (150.00) 993 (2190) 73 G6-67 8/08j Page 4
Fuel Tank Weights and Dimensions Fuel Tanks for Open and Enclosed Generator Sets with 1040 mm (41 in.) and 1250 mm (49 in.) Skids, continued Note: All fuel tanks are Type 1 (see page 1 for an illustration) kw 100REOZJD 125REOZJB 125REOZJD 135REOZJC 150REOZJB 150REOZJC 150REOZJD 180REOZJB 180REOZJC 180REOZJD Kit No. Capacity, L (gal.) Length, Width, Height, Weight, kg (lb.) Est. Fuel Supply, Hours at 60 Hz with Full Load GM32625-KP11/KA11 382 (101) 305 (12) 375 (826) 12 GM32625-KP12/KA12 810 (214) 2400 (94.49) 610 (24) 524 (1156) 26 GM32625-KP13/KA13 1234 (326) 674 (1485) 39 GM32625-KP17/KA17 1499 (396) 2800 (110.24) 761 (1678) 48 GM32625-KP22/KA22 2249 (594) 3810 (150.00) 993 (2190) 72 GM32625-KP14/KA14 432 (114) 305 (12) 404 (891) 12 GM32625-KP15/KA15 908 (240) 2600 (102.36) 610 (24) 562 (1239) 26 GM32625-KP16/KA16 1385 (366) 720 (1587) 39 GM32625-KP21/KA21 1874 (495) 3302 (130.00) 877 (1934) 53 GM32625-KP23/KA23 2627 (694) 4318 (170.00) 1109 (2446) 75 457 (18) 517 (1139) 20 GM32625-KP19/KA19 1272 (336) 2800 (110.24) 762 (30) 683 (1505) 34 GM32625-KP20/KA20 1537 (406) 766 (1688) 41 GM32625-KP22/KA22 2249 (594) 3810 (150.00) 993 (2190) 60 GM32625-KP24/KA24 3388 (895) 5436 (214.00) 1593 (3513) 90 457 (18) 517 (1139) 18 GM32625-KP19/KA19 1272 (336) 2800 (110.24) 762 (30) 683 (1505) 31 GM32625-KP20/KA20 1537 (406) 766 (1688) 37 GM32625-KP22/KA22 2249 (594) 3810 (150.00) 993 (2190) 55 GM32625-KP24/KA24 3388 (895) 5436 (214.00) 1593 (3513) 82 457 (18) 517 (1139) 16 2800 (110.24) GM32625-KP19/KA19 1272 (336) 762 (30) 683 (1505) 28 GM32625-KP21/KA21 1874 (495) 3302 (130.00) 877 (1934) 41 GM32625-KP22/KA22 2249 (594) 3810 (150.00) 993 (2190) 49 GM32625-KP24/KA24 3388 (895) 5436 (214.00) 1593 (3513) 73 457 (18) 517 (1139) 16 2800 (110.24) GM32625-KP19/KA19 1272 (336) 762 (30) 683 (1505) 27 GM32625-KP21/KA21 1874 (495) 3302 (130.00) 877 (1934) 40 GM32625-KP22/KA22 2249 (594) 3810 (150.00) 993 (2190) 48 GM32625-KP24/KA24 3388 (895) 5436 (214.00) 1593 (3513) 73 457 (18) 517 (1139) 17 2800 (110.24) GM32625-KP19/KA19 1272 (336) 762 (30) 683 (1505) 29 GM32625-KP21/KA21 1874 (495) 3302 (130.00) 877 (1934) 42 GM32625-KP22/KA22 2249 (594) 3810 (150.00) 993 (2190) 51 GM32625-KP24/KA24 3388 (895) 5436 (214.00) 1593 (3513) 76 457 (18) 517 (1139) 14 2800 (110.24) GM32625-KP20/KA20 1537 (406) 766 (1688) 28 GM32625-KP22/KA22 2249 (594) 3810 (150.00) 993 (2190) 41 GM32625-KP23/KA23 2627 (694) 4318 (170.00) 1109 (2446) 48 GM32625-KP25/KA25 3944 (1042) 6198 (244.00) 1814 (4000) 72 457 (18) 517 (1139) 14 2800 (110.24) GM32625-KP20/KA20 1537 (406) 766 (1688) 30 GM32625-KP21/KA21 1874 (495) 3302 (130.00) 877 (1934) 36 GM32625-KP23/KA23 2627 (694) 4318 (170.00) 1109 (2446) 51 GM32625-KP25/KA25 3944 (1042) 6198 (244.00) 1814 (4000) 76 GM32625-KP26/KA26 939 (248) 457 (18) 599 (1320) 18 2975 (117.13) GM32625-KP27/KA27 1609 (425) 762 (30) 782 (1724) 31 GM32625-KP28/KA28 2347 (620) 3454 (136.00) 1250 (49.21) 992 (2186) 46 GM32625-KP29/KA29 3096 (818) 4267 (168.00) 1197 (2638) 60 GM32625-KP30/KA30 4614 (1219) 5994 (236.00) 1950 (4300) 90 G6-67 8/08j Page 5
Fuel Tank Weights and Dimensions Fuel Tanks for Open and Enclosed Generator Sets with 1040 mm (41 in.) and 1250 mm (49 in.) Skids, continued Note: All fuel tanks are Type 1, except where noted (see page 1 for an illustrations) kw Kit No. Capacity, L (gal.) Length, Width, Height, Weight, kg (lb.) Est. Fuel Supply, Hours at 60 Hz with Full Load GM32625-KP26/KA26 939 (248) 457 (18) 599 (1320) 17 2975 (117.13) GM32625-KP27/KA27 1609 (425) 762 (30) 782 (1724) 29 200REOZJB GM32625-KP28/KA28 2347 (620) 3454 (136.00) 1250 (49.21) 992 (2186) 42 GM32625-KP29/KA29 3096 (818) 4267 (168.00) 1197 (2638) 55 GM32625-KP30/KA30 4614 (1219) 5994 (236.00) 1950 (4300) 82 GM32625-KP26/KA26 939 (248) 457 (18) 599 (1320) 17 2975 (117.13) GM32625-KP27/KA27 1609 (425) 762 (30) 782 (1724) 29 200REOZJC GM32625-KP28/KA28 2347 (620) 3454 (136.00) 1250 (49.21) 992 (2186) 42 GM32625-KP29/KA29 3096 (818) 4267 (168.00) 1197 (2638) 55 GM32625-KP30/KA30 4614 (1219) 5994 (236.00) 1950 (4300) 82 GM32625-KP26/KA26 939 (248) 457 (18) 599 (1320) 16 2975 (117.13) GM32625-KP27/KA27 1609 (425) 762 (30) 782 (1724) 28 200REOZJD GM32625-KP28/KA28 2347 (620) 3454 (136.00) 1250 (49.21) 992 (2186) 41 GM32625-KP29/KA29 3096 (818) 4267 (168.00) 1197 (2638) 53 GM32625-KP30/KA30 4614 (1219) 5994 (236.00) 1950 (4300) 80 GM32625-KP26/KA26 939 (248) 457 (18) 599 (1320) 15 2975 (117.13) GM32625-KP27/KA27 1609 (425) 762 (30) 782 (1724) 25 230REOZJB GM32625-KP28/KA28 2347 (620) 3454 (136.00) 1250 (49.21) 992 (2186) 37 GM32625-KP29/KA29 3096 (818) 4267 (168.00) 1197 (2638) 48 GM32625-KP30/KA30 4614 (1219) 5994 (236.00) 1950 (4300) 72 GM32625-KP31/KA31 1840 (222) 460 (18) 586 (1292) 14 3100 (122.05) GM32625-KP32/KA32 1794 (474) 1250 (49.21) 869 (1916) 29 230REOZJD GM32625-KP33/KA33 2782 (735) 4200 (165.35) 1146 (2526) 46 GM32625-KP34/KA34* 3655 (966) 4900 (192.91) 1350 (53.15) 1589 (3503) 60 GM32625-KP35/KA35* 5526 (1460) 5100 (200.79) 1850 (72.83) 2038 (4493) 91 GM32625-KP31/KA31 1840 (222) 460 (18) 586 (1292) 13 3100 (122.05) GM32625-KP32/KA32 1794 (474) 1250 (49.21) 869 (1916) 27 250REOZJD GM32625-KP33/KA33 2782 (735) 4200 (165.35) 1146 (2526) 42 GM32625-KP34/KA34* 3655 (966) 4900 (192.91) 1350 (53.15) 1589 (3503) 55 GM32625-KP35/KA35* 5526 (1460) 5100 (200.79) 1850 (72.83) 2038 (4493) 83 GM32625-KP31/KA31 1840 (222) 460 (18) 586 (1292) 11 3100 (122.05) GM32625-KP32/KA32 1794 (474) 1250 (49.21) 869 (1916) 24 275REOZJD GM32625-KP33/KA33 2782 (735) 4200 (165.35) 1146 (2526) 37 GM32625-KP34/KA34* 3655 (966) 4900 (192.91) 1350 (53.15) 1589 (3503) 49 GM32625-KP35/KA35* 5526 (1460) 5100 (200.79) 1850 (72.83) 2038 (4493) 74 * Fuel tanks are Type 2. Add 152 mm (6 in.) to height dimension for I-beams. G6-67 8/08j Page 6
Fuel Tank Weights and Dimensions Fuel Tanks for Open Generator Sets with 864 mm (34 in.) Skids Note: All fuel tanks are Type 1 (see page 1 for an illustration) kw 20REOZJB 20ROZJB 30REOZJB 40REOZJB 50REOZJB 60REOZJB 80REOZJB 80REOZJC 80REOZJD 100REOZJB 100REOZJC Kit No. Capacity, L (gal.) Length, Width, Height, Weight, kg (lb.) Est. Fuel Supply, Hours at 60 Hz with Full Load GM32623-KP1/KA1 227 (60) 305 (12) 277 (610) 26 GM32623-KP2/KA2 356 (94) 457 (18) 338 (745) 40 2000 (78.74) 864 (34.02) GM32623-KP3/KA3 481 (127) 610 (24) 399 (879) 55 GM32623-KP4/KA4 738 (195) 521 (1149) 84 GM32623-KP1/KA1 227 (60) 305 (12) 277 (610) 26 GM32623-KP2/KA2 356 (94) 457 (18) 338 (745) 40 2000 (78.74) 864 (34.02) GM32623-KP3/KA3 481 (127) 610 (24) 399 (879) 55 GM32623-KP4/KA4 738 (195) 521 (1149) 84 GM32623-KP1/KA1 227 (60) 305 (12) 277 (610) 20 GM32623-KP2/KA2 356 (94) 457 (18) 338 (745) 31 2000 (78.74) GM32623-KP3/KA3 481 (127) 864 (34.02) 610 (24) 399 (879) 41 GM32623-KP4/KA4 738 (195) 521 (1149) 64 GM32623-KP11/KA11 973 (257) 2438 (95.98) 611 (1346) 84 GM32623-KP1/KA1 227 (60) 305 (12) 277 (610) 17 GM32623-KP2/KA2 356 (94) 457 (18) 338 (745) 27 2000 (78.74) GM32623-KP3/KA3 481 (127) 864 (34.02) 610 (24) 399 (879) 36 GM32623-KP4/KA4 738 (195) 521 (1149) 56 GM32623-KP11/KA11 973 (257) 2438 (95.98) 611 (1346) 73 GM32623-KP5/KA5 265 (70) 305 (12) 303 (667) 16 GM32623-KP6/KA6 413 (109) 2200 (86.61) 457 (18) 367 (810) 25 GM32623-KP8/KA8 708 (187) 864 (34.02) 762 (30) 498 (1098) 43 GM32623-KP11/KA11 973 (257) 2438 (95.98) 611 (1346) 60 GM32623-KP15/KA15 1272 (336) 2946 (116.00) 717 (1581) 78 GM32623-KP5/KA5 265 (70) 305 (12) 303 (667) 14 GM32623-KP7/KA7 560 (148) 2200 (86.61) 610 (24) 433 (954) 29 GM32623-KP8/KA8 708 (187) 864 (34.02) 762 (30) 498 (1098) 36 GM32623-KP11/KA11 973 (257) 2438 (95.98) 611 (1346) 50 GM32623-KP16/KA16 1480 (391) 3302 (130.00) 792 (1745) 76 GM32623-KP6/KA6 413 (109) 457 (18) 367 (810) 16 2200 (86.61) GM32623-KP8/KA8 708 (187) 762 (30) 498 (1098) 28 GM32623-KP11/KA11 973 (257) 2438 (95.98) 864 (34.02) 611 (1346) 38 GM32623-KP15/KA15 1272 (336) 2946 (116.00) 717 (1581) 49 GM32623-KP18/KA18 1866 (493) 3962 (156.00) 929 (2049) 73 GM32623-KP9/KA9 469 (124) 457 (18) 397 (876) 16 2400 (94.49) GM32623-KP10/KA10 806 (213) 762 (30) 536 (1182) 28 GM32623-KP14/KA14 1124 (297) 2692 (106.00) 864 (34.02) 664 (1464) 39 GM32623-KP16/KA16 1480 (391) 3302 (130.00) 792 (1745) 51 GM32623-KP19/KA19 2207 (583) 4623 (182.00) 1234 (2720) 77 GM32623-KP9/KA9 469 (124) 457 (18) 397 (876) 17 2400 (94.49) GM32623-KP10/KA10 806 (213) 762 (30) 536 (1182) 30 GM32623-KP14/KA14 1124 (297) 2692 (106.00) 864 (34.02) 664 (1464) 43 GM32623-KP16/KA16 1480 (391) 3302 (130.00) 792 (1745) 56 GM32623-KP19/KA19 2207 (583) 4623 (182.00) 1234 (2720) 84 GM32623-KP12/KA12 526 (139) 457 (18) 427 (941) 17 2600 (102.36) GM32623-KP13/KA13 905 (239) 762 (30) 574 (1265) 28 GM32623-KP15/KA15 1272 (336) 2946 (116.00) 864 (34.02) 717 (1581) 40 GM32623-KP17/KA17 1688 (446) 3658 (144.00) 866 (1909) 53 GM32623-KP20/KA20 2559 (676) 5232 (206.00) 1378 (3039) 80 GM32623-KP9/KA9 469 (124) 2400 (94.49) 864 (34.02) 457 (18) 397 (876) 15 GM32623-KP10/KA10 806 (213) 2400 (94.49) 762 (30) 536 (1182) 26 GM32623-KP14/KA14 1124 (297) 2692 (106.00) 664 (1464) 37 864 (34.02) GM32623-KP16/KA16 1480 (391) 3302 (130.00) 792 (1745) 48 GM32623-KP19/KA19 2207 (583) 4623 (182.00) 1234 (2720) 72 G6-67 8/08j Page 7
KOHLER CO., Kohler, Wisconsin 53044 USA Phone 920-565-3381, Fax 920-459-1646 For the nearest sales and service outlet in the US and Canada, phone 1-800-544-2444 KohlerPower.com Kohler Power Systems Asia Pacific Headquarters 7 Jurong Pier Road Singapore 619159 Phone (65) 6264-6422, Fax (65) 6264-6455 Fuel Tank Weights and Dimensions Fuel Tanks for Open Generator Sets with 864 mm (34 in.) Skids, continued Note: All fuel tanks are Type 1 (see page 1 for an illustration) kw 100REOZJD 125REOZJB Kit No. Capacity, L (gal.) Length, Width, Height, Weight, kg (lb.) Est. Fuel Supply, Hours at 60 Hz with Full Load GM32623-KP9/KA9 469 (124) 457 (18) 397 (876) 15 2400 (94.49) GM32623-KP10/KA10 806 (213) 762 (30) 536 (1182) 25 GM32623-KP14/KA14 1124 (297) 2692 (106.00) 864 (34.02) 664 (1464) 36 GM32623-KP16/KA16 1480 (391) 3302 (130.00) 792 (1745) 48 GM32623-KP19/KA19 2207 (583) 4623 (182.00) 1234 (2720) 72 GM32623-KP12/KA12 526 (139) 457 (18) 427 (941) 15 2600 (102.36) GM32623-KP13/KA13 905 (239) 762 (30) 574 (1265) 26 GM32623-KP15/KA15 1272 (336) 2946 (116.00) 864 (34.02) 717 (1581) 36 GM32623-KP17/KA17 1688 (446) 3658 (144.00) 866 (1909) 48 GM32623-KP20/KA20 2559 (676) 5232 (206.00) 1378 (3039) 73 DISTRIBUTED BY: Availability is subject to change without notice. Kohler Co. reserves the rightto change the design or specifications without notice and withoutany obligation or liability whatsoever. Contact your local Kohler generator distributor for availability. 2004, 2005, 2006, 2007, 2008 by Kohler Co. All rights reserved. G6-67 8/08j Page 8