E-training. Operating characteristics and sizing of pneumatic actuators. The main types of pneumatic actuator

Similar documents
E-training. Positioners (Pneumatic, Electro pneumatic, I to P converters) Pneumatically actuated valves can be positioned in a number of ways.

CENTAC Inlet and Bypass Valve Positioners

PNEUMATIC ON OFF GLOBE VALVE

Smart Positioner YT-2400L,R Installation manual

CVS Rack and Pinion Pneumatic Actuator

Pneumatic-Pneumatic Positioner YT-1200L,R Installation manual

AV INSTALLATION, OPERATION & MAINTENANCE MANUAL

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Installation & Operation Manual

DDH hydraulic series. Spring return & double acting Compact actuator DUXVALVES B.V. BORNSESTRAAT PB ALMELO, THE NETHERLANDS

C Series Pneumatic Rack & Pinion Rotary Actuators

CHBE320 LECTURE III ACTUATOR AND CONTROL VALVE SELECTION. Professor Dae Ryook Yang

Fisher VBL Volume Booster

Fisher 657 and 667 Diaphragm Actuators

Fisher 480 Series Yokeless Piston Actuators

GP & GH Range. Pneumatic and Hydraulic Actuators for Quarter-Turn Valves. Established Leaders in Actuation Technology

Pneumatic Positioner PNY Series USER'S MANUAL. Max-Air Technology. Version 1.0

SY Series Scotch Yoke Actuators

SERIES M STANDARD FEATURES STANDARD OPTIONS. Double acting or spring return. Heavy duty housing, torque plug and piston rod design.

Pneumatic Rotary Actuator Type 3278

[P F/A] CHAPTER ,' II ' Hydraulic Actuators. cylinders. what cylinders consist of.

Automation is the techniques and equipment used to achieve automatic operation or control.

Nor East. Instructions. Safety Messages. Inspection. Parts Nor East Controls. Service. Type 05 Air-O-Motor Actuator Used With Globe Valves

Chapter 11: Valves and Actuators with the NAMUR-interface

flowserve.com Limitorque LRP Limitorque Rack & Pinion Pneumatic Actuator

KEYSTONE FIGURE 79 PNEUMATIC ACTUATOR OPERATING AND MAINTENANCE INSTRUCTIONS

User s Manual. Pneumatic Positioner. Series 58. J Flow. Series 58. J Flow

KTM PNEUMATIC ACTUATORS AW, AWN SERIES (FOR LARGE SIZED VALVES)

Changes in direction.! Using pulleys with belts

Fisher SS-263 Volume Booster

Anodised aluminium construction for anti-corrosion and superior wear performance on internal surfaces

Model DFLP Linear Actuator

The Series 3800 Rotary piston actuator are designed to operate rotary valves, such as Ball valves. Butterfly valves and Plug valves

Connectors for Diagnostic Testing with the FlowScanner Valve Diagnostic System

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

Spring return pneumatic quarter-turn actuator for spring end torques to 685,500 lb.in.

4th GENERATION PNEUMATIC ACTUATOR

Double and Single Acting Pneumatic Quarter-turn Actuators with Flexible Valve and Accessory Mounting

COMPACT PNEUMATIC ACTUATOR 4x4

CSY SERIES. Pneumatic Rotary. Actuator. Double-Acting or Spring-Return Torques up to 2,500,000 in-lb Modular Design

Manual Quarter Turn Valve Actuators

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Baumann Sanitary Diaphragm Angle and Inline Control Valve

BSM Series Pneumatic & Hydraulic Actuator Systems for Valves and Dampers

Spring Return and Double Acting Pneumatic Quarter-turn Actuators Operations Manual

Introduction Parker Series spring return (AC/AO) or double acting (AD) rack and pinion actuators are compact, simply designed devices that are quality

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

ACTUATORS AND AUTOMATIC VALVES

SPECIALTY CONTROL VALVES FOR UREA PLANTS

Model DFR Valve Actuator

Type 1035/El-O-Matic Rack-and-Pinion Rotary Actuator

CONTROLS. S98 Pneumatic Actuator

range to scotch-yoke pneumatic & hydraulic actuators, rack and pinion actuators and relevant control systems.

MTC Series. Double Acting and Spring Return Actuator and Accessories. MasterTorq. Pneumatic Actuators. Atex Class 2

Fisher 656 Diaphragm Actuator


AQA GCSE Design and Technology 8552

VALVITALIA VALVE OPERATORS

SMART POSITIONER YT-2300 SERIES USER'S MANUAL

Syslog Technologies Innovative Thoughts

MORIN. Pneumatic and hydraulic actuators EXPERIENCE MORE

Model DFRP Rotary Actuator

D-Series Rack & Pinion Pneumatic Actuators

PNEUMATIC RACK & PINION ACTUATOR

TOP-QUALITY PNEUMATIC ACTUATOR

General Hook-Clamp Features:

Pumps,Compressors & Valves Maintenance. Malaysia, Kuala Lumpur, Fraser Place Kuala Lumpur. Training Course : Training Course For One Week In

Fisher 3024C Diaphragm Actuator

Lesson 5: Directional Control Valves

SECTION CONTROL VALVE ACTUATORS

VW Arc-Weldable Strain Gauge

E Range of Electro - Hydraulic Linear and Rotary Actuators. Technical Specification.

HYDRAULIC ACTUATORS EC-SERIES. ELFORCONTROLS Actuators and Valves Automation

IMPACT REGISTER, INC. PRECISION BUILT RECORDERS SINCE 1914

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

Baumann Sanitary Angle Control Valve

Removing the Actuator for Valve Repair IMPORTANT! READ THIS BEFORE PROCEEDING!

Service Guide JATCO Environmental Protection Tank Model J-7000

NE January 2016 SINGLE SEATED CAGE VALVES SERIES 9100 MODEL Previously manufactured by Dezurik and Honeywell

P.E.D. SIL3 HIGH PERFORMANCE HEAVY DUTY ACTUATOR DRS

Operation Manual For KITZ B Series Pneumatic Valve Actuators

Distributed By: M&M Control Service, Inc

Trouble Shooting Guide for V100 Positioner

Pneumatic Control Valve Assembly Type 3331/3278

CBB-Series Scotch-Yoke Pneumatic Actuators Improved Design - Compact, Lightweight To Suit All Applications And Environment

Dassault Systèmes Automotive Powertrain Assembly Analysis with Abaqus

2.10. page Accessories for smart valve automation

BR 30a. Pneumatic Multi-turn Actuator. Application: Special designs:

Moments. It doesn t fall because of the presence of a counter balance weight on the right-hand side. The boom is therefore balanced.

Double Acting and Spring Return Direct Gas Quarter-turn Actuators Output Torques to 6,500,000 lb.in.

ELECTRO-HYDRAULIC ACTUATION SYSTEMS

Flow Line Controls. Installation & Operations Manual SERIES 20/21 Pneumatic Actuators

International Journal of Advance Engineering and Research Development. Design and Development of Pneumatic Stirrup Bending Machine

Air Operated 3 Way Stainless Steel Ball Valve

BULLTIN B PISTON ACTUATOR. The Actuator that Delivers Maximum Torque for Minimum Air Consumption

N-Line Valves. Surface Stepping Actuators

Biffi Morin S series actuators

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Declaration of Conformity

Surface Safety Valves Protecting Your Personnel, Facilities, Environment and Natural Resources

Transcription:

Welcome to the K Controls e-training course designed to deliver useful Pneumatic Valve Actuation application information in small instalments. To unsubscribe or to register a colleague to receive these documents Click here Operating characteristics and sizing of pneumatic actuators The main types of pneumatic actuator Pneumatic actuators provide (rotary) torque or (linear) thrust to operate a valve via the application of compressed air to a piston, diaphragm or vane. Pistons or vanes are sealed with elastomeric "O" rings. Linear actuators apply the thrust from a piston or diaphragm directly, whereas rotary or quarter turn actuators convert thrust to torque via mechanisms such as a scotch yoke, rack and pinion or vane. Scotch yoke design: Rack and pinion design: Vane design: If compressed air is available pneumatic actuators can be used in place of electric equivalents because they can operate faster and more frequently, their cost is usually lower (especially when fail safety is required), they are often more compact (on smaller valves) and they can readily be adapted for use in hazardous areas.

For a given design of actuator, the pressure applied to the piston, diaphragm or vane will determine the output thrust or torque. The volume of air available and the rate at which it enters and exhausts the actuator will determine its speed. The addition of quick exhaust valves or adjustable speed restrictors can increase or decrease cycle times. The internal porting size of the actuator also determines the speed that can be obtained. It should also be noted that the torque output from rotary actuators is not always constant. As torque equals the force applied multiplied by the distance from the pivot point, actuator design is important. In a rack and pinion or vane type actuator the distance from the pivot point is constant throughout the stroke and so, therefore, is the torque. With a scotch yoke design however, the distance from the pivot point varies throughout the stroke and so, therefore, does the torque. As the torque requirement of most valves also varies throughout the stroke, an attempt should be made to match the operating characteristics of valve and actuator as closely as possible. The torque output from a given size of actuator has been increased with special designs. E.g. Two vane units attached together or in the case of quarter turn rack and pinion actuators, using double opposed or even four opposing pistons. Extended rack and pinion designs are available for multi-ported valves that operate through 180 degrees. Scotch yoke typical torque output (double acting): Solid line: Angled slot. Dotted line: Parallel slot Rack and pinion typical torque output (double acting): Vane typical torque output (double acting):

Piston and vane based devices can either use air for both strokes (known as "double acting") or air for one stroke and springs for the other (known as "single acting" or "spring return"). Piston devices will usually have one or more coil springs housed within the main actuator housing. Vane actuators have a clock type spring situated in an enclosure above or below the actuator. Diaphragm actuators will usually have springs to provide the thrust on the return stroke. When compressed air is allowed to vent from the actuator, the springs will automatically start to move the valve in the opposite direction to a pre-determined "failsafe" position. As the effective area of a diaphragm is quite large and the response is linear, it can operate with low pressures and be used to respond to a 3-15 psi control signal without the use of a positioner. Flat diaphragms have a limited stroke length. Moulded or rolling diaphragms permit longer strokes and are better at maintaining the effective area. When the springs are below the diaphragm the unit is said to be direct acting. When the springs are above the diaphragm the unit is said to be reverse acting. Whether a valve fails open or fails closed with a reverse acting actuator will be a function of valve design. Where the addition of springs would make the actuator too large or heavy, an accumulator tank may be installed to store air pressure. This adds an "air fail safe" facility to a double acting actuator. The process of filling and venting actuators is usually controlled by solenoid valves that are either fitted to each actuator or panel mounted remotely. Controlling the air supply to pneumatic actuators The process of filling and venting actuators is usually controlled by solenoid valves. For detailed information on how this is done see the e-training document on solenoid control. Failsafe pneumatic actuators One of the benefits of pneumatic actuators is that springs can be used to return a valve to its pre-determined "failsafe" position in the event of air, signal or solenoid failure. However, it is important to note that the failsafe position might be the last set position. If this is the case double acting actuators should be used with solenoid control that provides a "stay put" function.

A single acting or spring return actuator will need to be larger than the double acting equivalent. This is because air pressure is needed to both operate the valve and compress the springs at the same time. The torque or thrust available to operate the valve will also change throughout the stroke because the more a spring is compressed, the greater the force required to maintain it in any given position. This means that that the torque or thrust available at the beginning of the air and spring strokes will be greater than that available at the end of the air and spring strokes. This is very important when sizing a single acting (spring return) actuator to match the of a particular valve operating under a given set of conditions. Single acting (spring return) rack and pinion design: Rack and pinion typical torque output (single acting): From left to right: Start of air stroke, end of air stroke, start of spring stroke, end of spring stroke Reduced or fluctuating air pressure The air pressure available at the actuator needs to be established and monitored. For example, the pressure at the compressor could be 5 bar, while at the actuator it could have dropped to 4 bar. If a double acting actuator has been sized based on 5 bar then insufficient torque or thrust may be available to operate the valve at 4 bar. Another consequence of reduced or fluctuating air pressure can be the unwanted movement of spring return actuators. If the pressure is insufficient to keep the springs fully compressed at one end of travel the actuator will start to "creep" and a valve may start to move with unintended consequences. With multi-spring actuators the number of springs can be reduced so they will remain compressed at a lower pressure; however the resultant torque available will then be lower.

A typical actuator torque chart will show torque outputs at various positions and operating pressures. With rotary single acting actuators the torque varies with the degree of spring compression, therefore torque figures are given for each of four positions: Start of air stroke, end of air stroke, start of spring stroke and end of spring stroke. Sizing a pneumatic actuator The torque or thrust requirement of a valve is determined by a number of factors: Operating frequency some valves will have a tendency to stick if left in one position over a period of time. This will increase the torque requirement. Type of service a wet media will help reduce valve torque whereas a dry media will increase it. Temperature this affects the hardness of the seating materials which in turn alters the valves torque requirement. Chemical attack on the valve seats swelling of the seats may result in increased interference and therefore higher torque. Finish of the sealing surface different friction coefficients give rise to different torque. Stem torque or friction - that is mainly a function of the tightness of the stem nut that compresses the packing against the stem. Pressure pressure drop across the valve will directly affect the loading on the valve and therefore the torque or thrust required to move it. Dynamic forces - caused by fluid velocity through a partially closed valve. (Dynamic torque can be positive or negative at different points in the cycle). The valve manufacturer will usually add an overall factor of safety prior to stating the figure that should be used for actuator sizing. The resultant torque or thrust requirement of the valve can then be matched against the torque or thrust output of the actuator. It is important that the torque or thrust of the actuator does not exceed the mechanical strength of the valve stem or shaft. Should there be an obstruction in the valve an oversized actuator could cause the stem or shaft to twist or bend. Maximum valve torque usually occurs at the "break out" point and this is usually when the valve starts to move from the closed position. When flow through a valve has started the torque drops to its lowest point, known as the "running" torque. The way that the torque requirement of the valve is distributed over the open / close cycle should also be examined because economies can be made by matching the torque characteristic of the valve and actuator as closely as possible. The diagram below indicates the average torque characteristics for three different valve types, under line pressure and flow conditions, for opening followed by immediate closing.

Left Closed Centre Open Right Closed If you have any questions or comments, would like a colleague to receive this information or you would like the latest list of training documents, please use the contact details below: K Controls Ltd 2 Crown Way Crown Business Centre Horton Road West Drayton UB7 8HZ United Kingdom Phone: +44 (0)1895 449601 Fax: +44 (0)207 990 8111 E-mail: sales@k-controls.co.uk Web: www.k-controls.co.uk Blog: www.k-controls.info Visit us: View a map Valve type Butterfly valve Plug Valve Ball valve The ball and plug valves have similar characteristics. The main difference is the slight increase exhibited by the ball valve curve about the fully open position caused by the increasing surface area of the ball coming into contact with the seats. The butterfly valve has a very different characteristic and a negative torque requirement is shown for a period on closure of the valve. Any actuator used for this application must have a minimum amount of free movement in order retain control of the valve and prevent shock loads developing in this phase of operation. In summary when sizing a pneumatic actuator it is best to have as much information about the torque or thrust characteristics of both the valve and the actuator across all points of the cycle. However if this is not possible, then matching the maximum valve torque or thrust (including a safety factor) to the minimum torque or thrust available from the actuator (while checking stem strength limits are not exceeded) is a practical alternative. Trademarks K Controls has used all reasonable resources and efforts to indicate and supply information regarding trademarks used in this document. The absence of a trademark identifier is not a representation that a particular word or technology is not a trademark. All trademarks are property of their respective owners. If we have failed to properly show a trademark, please e-mail us and we will attempt to correct it. The ownership of all trademarks referred to in this document is acknowledged. Legal Disclaimer This document is written by K Controls for use by its clients. Although we make every reasonable attempt to verify the accuracy of the technical information and advice provided, we can take no responsibility for loss or damage resulting from its interpretation or application. K Controls is not in any way responsible, and has no legal liability, in respect of the contents of any other web site accessed via this document, nor for information provided via that site. All information accessed via links in this document is protected by international copyright laws and may not be reproduced in any form without the explicit written permission of the author. This E-mail and any files transmitted with it are confidential and may be legally privileged. It is intended solely for clients of K Controls Ltd. Any unauthorized recipient should advise K Controls immediately of the error. Copyright K Controls Ltd 2010 - All rights reserved.