Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions

Similar documents
E818/828 Series Fugitive Emissions 150# and 300# Flanged 2" - 8" Two-Piece Ball Valves Installation, Operation and Maintenance Instructions

Solenoid Block Kit for Series 90 Modular Accessory System Installation, Operation and Maintenance Instructions

Metal Characterized-seated Control Valve 1. /4" 4" CPT 44 and 1 /2" 4" CPT 51/52 Installation, Operation and Maintenance Instructions

Installation, Operation and Maintenance Instructions Series 608 Ball Valve

USER INSTRUCTIONS. Installation Operation Maintenance. NAF Setball SF Ball Sector Valves. Experience In Motion FCD NFENIM A4 09/16

Vogt Valves The Connection Bulletin for Forged Steel Globe Valves for Water-Free Chlorine Service Class 300, 600 & 800 CB 07

McCANNA Actuation Systems B

MARPAC K SERIES. Full Bore Fire Safe Flanged Ball Valves

Vogt Valves The Connection Bulletin for Y Pattern Globe & Check Valves Class 1690 & Class 2680 CB 18

Valtek Spring Cylinder Linear Actuators

Worcester Controls Directional Ball Valves

USER INSTRUCTIONS. NAF Trunnball DL Ball Valves. Installation Operation Maintenance. Experience In Motion FCD NFENIM A4 01/15

DeviceNet Interface For Series 75 Electric Valve Actuators

TECHNICAL BULLETIN. Audco Ball Valve. Reduced Bore Fire safe Flanged Ball Valves 51/52 Series. Experience In Motion

flowserve.com Limitorque LRP Limitorque Rack & Pinion Pneumatic Actuator

WORCESTER CONTROLS F519/529/819/829. Full Bore Fire Safe Flanged Ball Valves

INSTRUCTION MANUAL. Anchor Darling 1878 Swing Check Valves. Installation Operation Maintenance. Sizes 1/2 through 2 FCD ADENIM

NAF Duball DL Pocket Ball Valves TECHNICAL BULLETIN FCD NFENTB A4 11/17

USER INSTRUCTIONS. Worcester Actuation Systems. Installation Operation Maintenance. Experience In Motion. Series 75 Electric Valve Actuator

USER INSTRUCTIONS. Valtek Control Products Spring Cylinder Linear Actuators. Installation Operation Maintenance. Experience In Motion

OpTK. Product Instruction Manual. Spring Cylinder Rotary Actuators INTRODUCTION SAFETY INFORMATION INSTALLATION. Leading Technologies For Control

Tri-Pac E325 / E525 Ball Valve Three-Piece Bolted Body, In-Line Maintainable, Regular and Full Port. McCANNA/MARPAC Valves RO400-R4

Valtek Flow Boosters

Worcester Controls H

Installation Instructions

Limitorque Accutronic MX/WTR Performance and Dimensions. Limitorque Actuation Systems

Installation Instructions

Flowserve Anchor Darling Isolation Valve Application

Kämmer Series Low Flow Valve

/2" 2" Series 94 and FZ94 Three-Piece Ball Valves, 1

Kämmer Series Low Flow Valves

TECHNICAL BULLETIN. NAF Setball SF Ball Sector Valves. Experience In Motion. flowserve.com. NAF Setball FCD NFENTB A4 02/16

Flowserve Spring Diaphragm Rotary Actuators

Valtek VL-HC Spring Cylinder Linear Actuators

Kämmer Series Split Body Valves

RACK & PINION ACTUATORS 2R40 to 2R1750 Series Installation & Maintenance Manual

flowserve.com Flowserve Solenoid Valves Namur, Remote and Banjo Mounted Designs for Precision Control

MERIDIAN, 2 or 3 PIECE, TRUNNION MOUNTED BALL VALVES

Installation Instructions

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

Rotary Valve Maxflo + 60 and 80 Opening type NT

TECHNICAL BULLETIN. NAF Trunnball DL Ball Valves. Experience in Motion FCD NFENTB A4 09/14

Installation Instructions

Limitorque Actuation Systems B320 Series. Rugged and dependable bevel gear operators for manual or motorized valve control applications

Experience In Motion. Flowserve Control Valve Products North American Quick Response Centers

Limitorque Actuation Systems PT Series Worm Gear Operator

Edward. Equiwedge Forged Gate Valvee. Experience In Motion

USER INSTRUCTIONS. Limitorque HBC Series. Installation Operation Maintenance. Experience In Motion FCD LMENIM A4 (10/14)

Installation Instructions

USER INSTRUCTIONS. Limitorque TM V Series. Installation Operation Maintenance. Experience In Motion FCD LMENIM AQ 02/15

USER INSTRUCTIONS. Spring Diaphragm Rotary Actuators. Installation Operation Maintenance. Experience In Motion FCD VLAIM /12

USER INSTRUCTIONS. Installation Operation Maintenance. Limitorque Actuation Systems L75 Series. Experience In Motion. Electric Valve Actuator

TECHNICAL BULLETIN. NAF Duball DL Ball Valves. Experience in Motion FCD NFENTB A4 12/14

Limitorque HBC Series Worm Gear Operators

S-17 CATALOG. Forged Steel Strainers

Installation Instructions

THD-SERIES S11DA280 THRU S27DA1020 & S11SR280 THRU S27SR1020 DOUBLE ACTING & SPRING RETURN SCOTCH YOKE ACTUATORS

Desuperheater FCD VLENTB /11. Experience In Motion

Product Specification

Installation Instructions

Installation Instructions

Accord DS/DM Series UltraSwitch Switch box

Installation Instructions

RVX Upgrade. ISO 13709/API 610 back pullout retrofit. Experience In Motion

Installation Instructions

Limitorque. HBC Series Worm gear operators proven in the most demanding situations

Valtek Valdisk 150. Valtek Valdisk 150. Control Valves. Flowserve Corporation, Valtek Control Products, Tel. USA

Installation Instructions

Mark 100. Technical Bulletin F C D F C A T B

flowserve.com Durco PlugSeal Valve ASME Class 600 Plug Valves Serving the Worldwide Desalination Industry Experience In Motion

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

SY-SERIES S04DA75 THRU S06DA180 & S04SR75 THRU S06SR180 DOUBLE ACTING & SPRING RETURN SCOTCH YOKE ACTUATORS

Valtek Tek-Check Control Valves Valtek Tek-Check

Plug Valve Solutions for the Upstream Exploration and Production Pipelines Production manifolds, test manifolds and other dirty services

Kämmer Multi-Z Severe Service Valves

CONNECTION BULLETIN. Vogt Valves. Experience In Motion. Zero Leakage Forged Steel Check Valves Class 800. FCD VVABR /04 (Replaces CB-03)

Edward Valves. Maintenance Manual for Edward Forged Steel Valves. Bolted and Screwed Bonnet Types V-376 R3

Installation Operation Maintenance

Valtek MaxFlo Control Valves

Valtek Tek-Check. Check Valves

V-SEGMENT SERIES V-Port Segment Control Valves (VS/VV/VM) Installation & Maintenance Manual

Installation Operation Maintenance

Installation Operation Maintenance

Valtek Position Pac GENERAL INFORMATION INSTALLATION INSTRUCTIONS OPERATION. Valtek Linear Actuators

AV INSTALLATION, OPERATION & MAINTENANCE MANUAL

flowserve.com Kämmer Multi-Z Kämmer Multi-Z Severe Service Valves

Series 51/52 Flanged Ball Valves Standard and Anti-Static Valves in ANSI Class 150 and 300. Worcester Controls. FCD WCABR (Part PB 51)

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Power-Seal High Performance Butterfly Valve: Series P1 Installation & Maintenance Manual

Quarter Master Series 94 Actuator

Valtek XL Series High Performance Positioner. for Control Valves

Valtek MaxFlo 3 Control Valves

USER INSTRUCTIONS. Valtek Valdisk TX3 Triple Offset Butterfly Control Valve. Installation Operation Maintenance. Experience In Motion

Fisher 657 Diaphragm Actuator Sizes and 87

Double Acting & Spring Return. SERIES 92/93 Rack & Pinion PNEUMATIC ACTUATOR. The High Performance Company

Mark 100. Installation, Operation and Maintenance Instructions F C D F C A I M

Valtek Auxiliary Handwheels and Limit Stops

Surepowr Series 100 Installation Manual

Valtek Beta Positioner. Valtek Beta Positioners. for Control Valves

IOM Manual. IOM Manual. Series 20/21.

Transcription:

WCAIM2049 (Part 18960) Series 72 Electri-SAFE On/Off Operation Including CLC Option Installation, Operation and Maintenance Instructions Series 72 actuators are electro-hydraulic quarterturn valve actuators. The design utilizes a double-rack, single-pinion concept, with each rack integrally cast to a piston. Both pistons are supported and centered by large, stainless steel guide rods. Standard units feature an extended top shaft for manual override capabilities and a completely modular design which allows simple attachment of a variety of accessories. All units feature a normally open solenoid valve which returns the actuator to its initial position when power is lost to the actuator. a WARNING: Series 72 actuators are electro-mechanical devices subject to normal wear and tear. Actuator life is dependent upon application and environmental conditions. If applied in hazardous services such as, but not limited to, media temperature extremes, toxins, flammables, or other services where improper or incomplete operation could produce a safety hazard, it is incumbent upon the system designer and the user to provide proper warning devices such as temperature sensors, oxygen sensors and flow sensors. CAUTION: Flowserve recommends that all products which must be stored prior to installation be stored indoors, in an environment suitable for human occupancy. Do not store product in areas where exposure to relative humidity above 85%, acid or alkali fumes, radiation above normal background, ultraviolet light, or temperatures above 120 F or below 40 F may occur. Do not store within 50 feet of any source of ozone. INSTALLATION NOTE: The Series 72 actuator is normally installed with its major axis parallel to the pipe line (this is mandatory when mounting actuator to 90 V1 diverter/three-way (D44 & T44) valves and CPT valves). The actuator can be oriented above, beside or beneath the valve without affecting its operation. B. Determine desired quadrant for bracket attachment and direction of mounting of actuator (in-line or cross-line). C. Attach mounting bracket to actuator using four (4) cap screws and lockwashers provided in mounting kit. To avoid any damage to the Series 72 actuator body, ONLY the proper length screws supplied with the mounting kit should be used. For small topmount style valves, attach bracket such that bracket nameplate will be to side of valve. For mounting to 818/828 Series valves, insert ISO locating ring into groove on bottom of actuator before attaching to bracket. Note: Ring can be permanently held in groove by applying Loctite to ring before inserting in groove. D. Attach bracket/actuator assembly to valve as follows: CAUTION: Ball valves can trap pressurized media in the cavity. If it is necessary to remove any valve body bolts, stem nuts or remove valve from the line, and if the valve is or has been in operation, make sure there is NO pressure to or in the valve and operate valve one full cycle. 1. Valve Models Top-Mount 44 ( 1 /4" 2"), 45 (2 1 /2" 4"), 51/52 ( 1 /2" 4"), 151/301 (3" 4"), Top Mount 59 ( 1 /4" 3"), WK70, WK74 and H71 ( 1 /2" 2"), 818/828 (2" 3"), 82/83 ( 1 /2" 3"), 94 ( 1 /2" 4"): NOTE: For above listed valves, it is not necessary to remove any valve body bolts or remove valve from line in order to mount actuator. a. Rotate valve ball and stem to position necessary to achieve desired operation. If any valve information is marked on stop plate or handle, it will be necessary to transfer this information to the bracket nameplate. Actuators come with an ISO locating ring used for optional ISO mounting. A. Determine mode of operation desired (normally open or normally closed) of the valve.

b. For 1 /4" 2" 44, 1 /2" 2" WK70 & WK74, 1 /4" 1 1 /2" 59 and 1 /2" 1 1 /2" H71 series top-mount style valves and 1 /2" 2" 51/52 and 1 /2" 1 1 /2" 82/83 Series valves with high-cycle stem packing as standard, remove handle nut, lockwasher, handle, separate stop plate (if any), retaining nut and stop pin(s). Add the two additional Belleville washers with their larger diameter sides touching each other. Add the self-locking nut to the stem and tighten while holding the stem flats with wrench. Tighten until Belleville washers are flat, the nut will "bottom", and then back nut off 1 /3 of a turn. The two additional Belleville washers and the self-locking nut are included in the mounting kit. CAUTION: The self-locking stem nut is difficult to tighten, and must fully flatten Belleville washers before backing off. For 2" 59, H71, 82/83 and 2 1 /2" 45, 82/83 valves, and valves 3" and larger with square stem, remove handle assembly, retaining nut, stop and stop screws. Replace with valve stem spacer or, if valve has graphite stem packing, with two Belleville washers, and replace retaining nut. NOTE: Belleville washers are installed with their larger diameter sides touching each other. Do not use stem spacer when Belleville washers are used. Using a wrench to prevent stem from turning, tighten retaining nut until stem packing is fully compressed or Bellevilles, if used, are fully flattened, then back off nut 1 /6 turn. Excessive tightening causes higher torque and shorter seal life. Large valves with V51 high-cycle stem packing option installed, (identified by two Belleville washers installed and handle assembly, stop, and stop screws removed), and 818/828 Series valves do not require stem area disassembly. For 1 /2" 2" 94 valves, remove handle (if any). Do not remove gland plate or gland bolts. For 3" 4" 94 & 2" 3" E818/828 valves, remove handle assembly, stop, and spacer (if any). Do not remove gland plate or gland bolts. For 2" 3" 818/828 valves, remove handle assembly, locking plates and hardware, and stop screw (if any). Do not remove stop plate. c. Center coupling on valve stem. d. Lower mounting bracket/actuator assembly over coupling and onto valve, making sure that male actuator shaft engages slot in coupling. e. Secure bracket to valve using cap screws and lockwashers, or bolts and nuts provided in mounting kit. Tighten securely. For small top-mount style valves, bracket nameplate will be to side of valve. Install set screws (if any) in the coupling and tighten securely. f. Determine if mode of operation is as desired; if not: Fail-Safe Actuators - The normal method of mounting is to have the actuator in-line with the pipe line and the valve and actuator in the FAIL-CLOSED position. For FAIL-CLOSED cross-line operation, invert actuator and cross-line mount actuator to pipe line. For FAIL-OPEN in-line operation, invert actuator. (NOTE: If in-line coupling is used, actuator does not need to be inverted.) Rotate the valve ball and stem 90, so coupling lines up with actuator shaft. Mount actuator in-line with the pipe line. For FAIL-OPEN cross-line operation, rotate the valve ball and stem 90, so coupling lines up with actuator shaft. Mount actuator cross-line to pipe line. g. Determine position indication. Buttons on position indicator are set up to show valve closed on in-line mounting, i.e., pistons together on actuator. If different indication is required: 1. Check which visual indication is required. 2. Check that indicator, when located on actuator shaft, will show correct indication. 3. To change indication, push out (remove) red and white buttons and reassemble in opposite positions. 4. Locate indicator on actuator shaft flats. Press firmly until location nibs snap into recess on actuator shaft. ELECTRICAL INSTALLATION AC Electrical Supply (on/off models with one integral solenoid): With assembly complete to this point, it is convenient to make conduit connections and bring wiring through enclosure. It should be noted that the successful use of this device in hazardous atmospheres or other detrimental environments depends on proper conduit construction techniques. The solenoid coil wattage and required amperage is as follows: Voltage Holding Amps* Watts 120 VAC 50/60 HZ.2 10 240 VAC 50/60 HZ.1 10 *Inrush is 80% greater than Holding values on AC solenoids. A. Remove limit switch cover and gasket. B. Attach power supply wires to terminal strip locations 7 and 8 per the wiring diagram shown below and also located on the inside of the limit switch cover. NOTE: All wiring to terminal strip should be inserted only to midpoint of strip. C. Attach the ground wire to the customer s green grounding screw located on the limit switch casting flange face. 2 Series 72 Electric-SAFE On/Off Operation Including CLC Option WCAIM2049

DC Wiring DC Electrical Supply (on/off models with one integral solenoid): With assembly complete to this point, it is convenient to make conduit connections and bring wiring through enclosure. It should be noted that the successful use of this device in hazardous atmospheres or other detrimental environments depends on proper conduit construction techniques. The solenoid coil wattage and required amperage is as follows: Voltage Holding Amps Watts 24 VDC.45 10 A. Remove limit switch cover and gasket. B. Attach power supply wires to terminal strip locations 7 and 8 per the wiring diagram shown on previous page and also located on the inside of the limit switch cover. NOTE: All wiring to terminal strip should be inserted only to midpoint of strip. C. Attach the ground wire to the customer s green grounding screw located on the limit switch casting flange face. AC Electrical Supply (CLC models with two integral solenoids): With assembly complete to this point, it is convenient to make conduit connections and bring wiring through enclosure. It should be noted that the successful use of this device in hazardous atmospheres or other detrimental environments depends on proper conduit construction techniques. Control solenoid wattage for 120 VAC and 240 VAC is 6 watts. The failsafe solenoid coil wattage and required amperage is as follows: Voltage Holding Amps* Watts 120 VAC 50/60 Hz.2 10 240 VAC 50/60 Hz.1 10 *Inrush is 80% greater than Holding values on AC solenoids. A. Remove limit switch cover and gasket. B. Attach power supply wires to terminal strip locations 7 and 8 per the wiring diagram shown below and also located on the inside of the limit switch cover. NOTE: All wiring to terminal strip should be inserted only to midpoint of strip. C. Attach the ground wire to the customer s green grounding screw located on the limit switch casting flange face. WCAIM2049 Series 72 Electric-SAFE On/Off Operation Including CLC Option 3

INSTALLATION OF ACCESSORIES For details on installation of accessories, refer to the installation instructions contained in respective accessory kit. OPERATION The Series 72 Actuator opens when power is applied. The hydraulic pump/motor is turned off when the actuator reaches its full open position by the limit switch SW-1. Power is maintained to the normally open solenoid to keep the actuator in the open position. A. Basic Actuator The Series 72 actuator drive shaft rotates through a full 90 segment with approximately 2 overtravel at each end of travel. Rotation is accomplished by pumping hydraulic fluid into the center chamber, forcing the two opposing pistons apart, resulting in a counter-clockwise rotation of the drive shaft to the "open" position. Closure is accomplished by means of springs contained within the end caps which force the pistons together when the power to the solenoid has been interrupted. If rotation opposite to that described above is required, refer to the section on Installation for the proper procedure to reverse the rotation. B. Stroke Times On/Off Version: Standard stroke times of the Series 72 actuator are shown in the following table. Times shown represent average times under 50% load conditions at 72 degrees Fahrenheit environmental temperature. Opening and closing speeds will increase as the environmental temperature goes down. Actuator temperature can be controlled through the use of heater elements, heating bands, insulation, and other typical means for hydraulic equipment temperature control. The figures shown below are meant as an indication of obtainable speeds only. Faster or slower speeds are obtainable, if required, by using additional control equipment. Actuator Size 1572 2072 Opening @ 72 F 6 sec. 10 sec. Closing @ 72 F 1 sec. 3 sec. CLC Version: The Series 72 equipped with the CLC option can attain the same speeds as the On/Off Version, or be adjusted to attain slower opening or closing speeds. Control of the actuator s cycle time is achieved by breaking up the power applied to the actuator into a series of pulses. Opening and closing speeds will increase as the environmental temperature goes down. Actuator temperature can be controlled through the use of heater elements, heating bands, insulation, and other typical means for hydraulic equipment temperature control. The length of time a power pulse is applied is controlled by the ON adjustable control. The interval between pulses is controlled by the OFF adjustable control. To adjust, start with both controls at midpoint. To reduce cycle time on 120 VAC units, turn ON control in CW direction and OFF control in CCW direction. To increase cycle time turn ON control in CCW direction and OFF in CW direction. To reduce cycle time on 240 VAC units, turn ON control in CCW direction and OFF control in CW direction. To increase cycle time turn ON control in CW direction and OFF control in CCW direction. DC Wiring CCW/CW (OPEN/CLOSE) CW (CLOSE) CCW (OPEN) 4 Series 72 Electric-SAFE On/Off Operation Including CLC Option WCAIM2049

IMPORTANT: If ON time adjustable control is at minimum and/or OFF time adjustable control is at maximum, the actuator will not rotate. The minimum ON pulse must allow the actuator to move a closed valve out of its seat. Verify proper CLC operation by opening a fully closed valve. C. Manual Operation In the event of power failure, the Series 72 actuator will cycle to the fail position, but can be cycled manually. This is accomplished by applying a wrench to the exposed top shaft of the actuator and turning it in the desired direction. Note that the actuator will not remain in the open position until power is restored to the fail-safe, normally open, solenoid. a WARNING: CARE MUST BE TAKEN TO ENSURE THAT THE ACTUATOR IS NOT OPERATED ELECTRICALLY WHILE MANUAL OPERATION IS BEING PERFORMED. D. Limit Switches The standard mounting configuration of the 72 Actuator to the valve is in-line, fail-closed. In this configuration, SW-1, as described in the wiring diagram (shown in electrical installation section and also located inside the limit switch cover) and shown in illustration below, will give indication when the actuator is in the open position, or CCW limit of rotation. SW-2 gives indication of the closed position, or CW limit of rotation. Actuator failure position may be changed by either inverting the actuator or mounting cross-line. In these cases, the limit switch must be mounted the same as described above, but SW-1 and SW-2 indication will be reversed from that above. If there is question as to which switch is going to indicate a given position, the actuator should be operated, and SW-1 and SW-2 checked to verify which switch will give the desired indication. CAUTION: Switches have been factory adjusted but should be rechecked after installation. Adjustment is as follows: 1. With actuator mounted in "standard" configuration, set actuator in closed position with the adjustment screw near its loose limit, adjust closed position switch SW-2 (see illustration) by tightening the adjusting screw until switch contacts click. Tighten the adjustment screw an additional 1 /4 turn. 2. Change actuator to its full open position and adjust open position switch SW-1. a) If the actuator does not open fully, back the adjusting screw out 1 /2 turn and cycle the actuator. b) If the actuator opens fully, and the motor continues to run, tighten the adjusting screw until the switch contacts click and tighten again by an additional 1 /4 turn. c) Cycle the actuator to verify the settings are correct. The limit switch SW-1 should stop the pump motor when the actuator is fully open. 3. Make electrical connections for the limit switches to the terminal strip, if applicable, in accordance with the wiring diagram inside the limit switch cover. 4. Install the limit switch cover. WCAIM2049 Series 72 Electric-SAFE On/Off Operation Including CLC Option 5

MAINTENANCE AND TROUBLESHOOTING CAUTION: THE ACTUATOR MUST BE ISOLATED ELECTRICALLY BEFORE ANY MAINTENANCE ACTIVITY OR COVER REMOVAL IS BEGUN. I. MAINTENANCE: Periodic checks should be performed to make certain that all mounting fasteners remain tight. II. TROUBLESHOOTING Any visible oil leakage is cause to replace the actuator. The actuator cannot be repaired and refilled with oil in the field. A. If actuator does not function, check to make sure: 1. That valve is free to rotate. This can be done as described in Manual Operation. 2. That actuator is the correct size. 3. That correct voltage is supplied to actuator. 4. That the motor is running, but the actuator does not move. If so, then replacement of the actuator may be required. B. If proper voltage has been verified and valve is free, proceed as follows: 1. Shut off power to the actuator and remove the limit switch cover. 2. Inspect all connections to the terminal strip and check for loose wires. 3. Turn on power to the actuator. a WARNING: EXPOSED ELECTRICAL CONNECTIONS CAN CAUSE SEVERE SHOCK. CARE MUST BE TAKEN TO PREVENT SHORT CIRCUIT CONNECTIONS FROM FINGERS, SCREWDRIVERS, AND TOOLS. 4. Check to see that the limit switch adjustment screws are set properly. If screws are tightened too much, the limit switch SW-1 will not allow the motor to run and the actuator will not operate. See OPERATION, Section D for adjustment procedure. Limit switch SW-2 does not affect the operation of the actuator. 5. If the motor still does not operate, turn off power to the actuator and replace the motor capacitor. If the motor still does not operate, replace the actuator. 6. Replace the cover gasket and cover, tightening all of the cover screws. C. If the actuator opens, but drifts closed and reopens in a cyclical operation: 1. Cycle the actuator a few times to see if the ball check valve will reseat. 2. If not, replace the actuator. The problem lies internal to the fluid passageway check valve and cannot be fixed in the field. D. If the actuator does not open, but the motor is running: 1. Remove the cover on the solenoid end of the actuator opposite the limit switch end. 2. Check the normally open solenoid to make sure the coil has voltage. 3. Replace the coil on the normally open solenoid if necessary. NOTE: When removing the solenoid, attach a chase string or wire to the coil wires as you pull the coil wires through the actuator. This will make feeding the new coil wires much easier. 4. If the solenoid coil has voltage and is operating properly, replace the actuator. Solenoid valve replacement cannot be done in the field without introducing air into the hydraulic system, and should be done at the factory. 6 Series 72 Electric-SAFE On/Off Operation Including CLC Option WCAIM2049

This page intentionally left blank. WCAIM2049 Series 72 Electric-SAFE On/Off Operation Including CLC Option 7

Flowserve Corporation has established industry leadership in the design and manufacture of its products. When properly selected, this Flowserve product is designed to perform its intended function safely during its useful life. However, the purchaser or user of Flowserve products should be aware that Flowserve products might be used in numerous applications under a wide variety of industrial service conditions. Although Flowserve can (and often does) provide general guidelines, it cannot provide specific data and warnings for all possible applications. The purchaser/user must therefore assume the ultimate responsibility for the proper sizing and selection, installation, operation, and maintenance of Flowserve products. The purchaser/user should read and understand the Installation Operation Maintenance (IOM) instructions included with the product, and train its employees and contractors in the safe use of Flowserve products in connection with the specific application. While the information and specifications contained in this literature are believed to be accurate, they are supplied for informative purposes only and should not be considered certified or as a guarantee of satisfactory results by reliance thereon. Nothing contained herein is to be construed as a warranty or guarantee, express or implied, regarding any matter with respect to this product. Because Flowserve is continually improving and upgrading its product design, the specifications, dimensions and information contained herein are subject to change without notice. Should any question arise concerning these provisions, the purchaser/user should contact Flowserve Corporation at any one of its worldwide operations or offices. For more information about Flowserve Corporation, contact www.flowserve.com or call USA 1-800-225-6989. FLOWSERVE CORPORATION FLOW CONTROL DIVISION 1978 Foreman Drive Cookeville, Tennessee 38501 USA Phone: 931 432 4021 Facsimile: 931 432 3105 www.flowserve.com 2003 Flowserve Corporation, Irving, Texas, USA. Flowserve and are registered trademarks of Flowserve Corporation. WCAIM2049 10/03 Printed in USA