Albér BDSUi and Albér BDSU-50. Battery Monitoring Systems For UPS Battery Cabinets

Similar documents
Liebert. EXM UPS kva/kw Efficient, Scalable, Intelligent Power Optimized for Midsize IT

Battery Monitoring Why Technology Matters. Mats Karlstrom V.P. Sales & Marketing, Alber

Liebert. EXM UPS kva/kw Efficient, Scalable, Intelligent Power Optimized for Midsize IT

Liebert. APS UPS 5-20 kva Flexible, efficient scalable UPS for room or row-based applications

Battery Maintenance Solutions for Critical Facilities

SENTINEL BATTERY MONITORING

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

NetSure. 211 Series DC Power System

Integrated Inverter/Battery Monitoring System (IBMS)

Symmetra PX 250/500. Scalable from 100 kva kw to 500 kw, parallel capable up to 2,000 kw

Battery Monitor Products. Trust Your Batteries TM. Doing it right!

Features and Benefits

Symmetra PX 96/160. Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

ENGINEERED TO ORDER SOLUTIONS

Extended Battery Cabinet for Nfinity

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

Battery Monitoring System

NetSure 5100 ORDERING GUIDE. 48V & 24V DC Power System (40 A to 600 A)

Valve Regulated Lead Acid (VRLA) Battery Series Designed for UPS Standby Power Applications FEATURES & BENEFITS

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

engineered to order solutions

SITE PLANNING DATA LIEBERT EXM 3-PHASE UPS: KVA/KW, 60HZ, VAC, SINGLE INPUT

Automatic DC Power Supply/Battery Charger

PowerFlex 6000 Medium Voltage AC Drives

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

DSS BATTERY DIAGNOSTIC SERVICE SYSTEM

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

ACTIVE ECO MODE IN SINGLE-PHASE UPS. Miguel Rascon AC Power Senior Product Manager

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

CHAIN WEAR ANALYSIS WITH LUBECON

Stationary Battery Testing

SUBSTATION EQUIPMENT - Page 1 of 8

SAFETY RULES. An Update on Lithium-ion Battery Use in Critical Facilities

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Hydro Plant Risk Assessment Guide

Liebert GXT4. Intelligent, Reliable UPS Protection 5kVA - 10kVA

APPLICATION GUIDE. ACH580 Managing total cost of ownership of HVAC systems

HYBRID POWER FOR TELECOM SITES

Using cloud to develop and deploy advanced fault management strategies

Cellwatch Battery Monitoring Systems

Battery Monitoring Systems

NterpriseIP Solution Adaptive, high-availability power system for IP Telephony. Business-Critical Continuity for Communications

L kw Distributed Energy Storage System Unit (SU50)

Est Battery Data Logger BDL3000

Symmetra PX. Symmetra PX250/500kW Scalable from 25kW to 500kW Parallel-capable up to 2000kW

Symmetra PX 100 kw. Scalable from 10 kw to 100 kw Modular, scalable, high-efficiency power protection for data centers

UPS Battery Maintenance Training

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Nfinity Battery Run Time Charts

Illuminator Series CR NEMA 3R

Technical Report TR

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

VERTIV XTE 401 SERIES. Ordering Guide

HIGH-PERFORMANCE MEDIUM VOLTAGE LOAD-COMMUTATED CURRENT SOURCE INVERTER POWER ELECTRONICS FOR INDUSTRIAL APPLICATIONS SISTEMI INDUSTRIALI

esure Rectifiers and NetSure DC Power Systems Krunoslav Štibi May 30thth, 2012

MKN-DSP SERIES - THREE PHASE

Emerson SmartCabinet for DELL VRTX Technical Guide

UPS5000-E (25-75 kva) Series

ValveLink SNAP-ON Application

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Business Case for Battery Monitoring

White Paper. Direct Current Load Banks for Battery Capacity Testing

Expect More From An Energy Storage Solution BATTERY FREE DC ENERGY STORAGE FOR UPS BILL WOLFE NORTHEAST REGIONAL MANAGER

Battery Technology for Data Centers and Network Rooms: Site Planning

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

Power Conversion System The Best Technology for your photovoltaic and storage system

Low and medium voltage service. Power Care Customer Support Agreements

Liebert. PSI & PSI-XR 750VA - 3kVA & 1kVA-3kVA High Performance Power Protection for Servers and Networking Equipment

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

MGE TM Galaxy TM 7000 GFC

1-Phase Intelligent ATS

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

LIEBERT: A CLEAR PATH TO THE FUTURE

ASPIRO & GUARDIAN BATTERY MANAGEMENT WITH ACC EXTENDED CONTROLLER

Orion BMS Purchasing Guide Rev. 1.2

Evolution 650/650 Rack 1U 850/850 Rack 1U 1150/1150 Rack 1U 1550/1550 Rack 1U Installation and user manual FR/AA - Page 1

AMS ValveLink SNAP-ON Applications

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

MGE TM Galaxy TM 7000

Asian paper mill increases control system utilization with ABB Advanced Services

High Effective Availability Decentralized UPS HEAD-UPS (c) 3.0 High Effective Availability Decentralized UPS-HEAD-UPS(c)

Sorensen XG Series / XTR Series W A. 850 W, 1U Half Rack Programmable DC Power Supplies V

Battery Aging Analysis

Magellan Utility Scale Energy Storage

Aurora Single Phase Emergency Lighting Inverters

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Pulsar EXtreme 2200C / 3200C

80V 300Ah Lithium-ion Battery Pack Data Sheet

Flexible, Customizable Power Solutions for Mission Critical Success

CHEMICALS AND REFINING. ABB in chemicals and refining A proven approach for transforming your challenges into opportunities

ET9500 BEMS Interface Box Configuration Guide

Baker PPX Power Packs

BMS-3923 Battery Monitoring System

Nuvation Low-Voltage BMS

Transcription:

Albér BDSUi and Albér BDSU-50 Battery Monitoring Systems For UPS Battery Cabinets

ALBÉR BDSUI AND ALBÉR BDSU-50 Maximize Your Uptime with an Albér Battery Monitoring System How Confident Are You That Your Batteries Will Be Available When You Need Them? Unplanned data center outages present a difficult and costly challenge for organizations. While eliminating downtime altogether is a challenging undertaking, organizations can start with the most frequent cause of unplanned outages uninterruptible power supply (UPS) battery failure. In most cases, the ability to keep critical systems running through power outages is dependent on the UPS. However, a UPS is only as reliable as the batteries that support it. Batteries are one of the most low-tech components supporting today s missioncritical data centers but they are the most vulnerable part of an UPS system. While the vast majority of unplanned outages last less than ten seconds, a single bad battery cell can cripple a data center s entire backup system, particularly if adequate UPS redundancy has not been implemented. Ponemon Institute Study on Data Center Outages. Top root cause of unplanned outages experienced during the last 2 years UPS battery failure Accidental EPO/human error UPS capacity exceeded Cyber attack IT equipment failure Water incursion Weather related Heat related/crac failure UPS equipment failure * 15% 20% 33% 29% 32% 35% 29% 33% 27% 30% 34% More than one response permitted 48% 51% 46% 55% 53% 65% Albér Battery Monitoring Systems Have Been Proven To Increase Critical Power Reliability According to a recent analysis of actual field results of batteries in real-world UPS environments by Vertiv s service organization, data centers with Albér battery monitoring systems installed on-site had a reduced rate of outages due to bad batteries. The use of Albér battery monitoring systems by customers increased the Mean Time Between Failure (MTBF) by more than double when compared to preventive maintenance alone. While outages still occurred at some of these sites, most of these incidents were isolated to human error where customers were not watching the alarm data provided by the battery monitoring system. The remote use of Albér battery monitoring systems by Vertiv technical experts resulted in no outages due to bad batteries. Not only does remote monitoring lift the burden of monitoring from internal personnel, but in many cases, it also integrates onsite and remote preventative maintenance activities in order to maximize battery availability. FY 2013 FY 2010 While batteries are one of the most low-tech components supporting today s mission-critical data centers, they are the most vulnerable part of an UPS system. 2

The Effect of Battery Monitoring Systems on Critical Power System Reliability* Outages Per Million Hours 0.5 0.4 0.3 0.2 0.1 0.0 0.3902 On-Site PMs The use of Albér battery monitoring by customers increased the MTBF by more than double when compared to preventative maintenance alone 0.1814 On-Site PMs with Albér Battery Monitoring The remote use of Albér battery monitoring by Emerson technical experts resulted in no outages due to bad batteries 0 On-site PMs with Remote Monitoring using Albér Battery Monitoring DECIDE Helps you make more informed decisions, faster by analyzing data and utilizing built-in decision support functions that determine what matters and what doesn t Albér Monitoring Systems Substantially Increase Battery Availability *Analysis based on more than 450 million operating hours over a 3.5 year period for more than 24,000 strings of batteries under Vertiv contract prior to the end of their expected service life. Features and Benefits SEE Helps you proactively address battery related issues that you could never see before by allowing you to visualize all critical information and know the real state of health of your batteries at all times (in real-time or historical trending) SEE SEE ANALYZE UNDERSTAND DECIDE VALIDATE PLAN USER BENEFITS Increased Availability ALBÉR BATTERY MONITORING SYSTEM FEATURES Detects open and shorted batteries Provides advance warning of an impending battery failure Eliminate the risk of human error ACTION ACT Reduced Maintenance Costs Reduced Replacement Costs Increased Safety Enables extended maintenance intervals by basing maintenance on the condition of the batteries rather than arbitrarily timed schedules Automates all of the IEEE recommended practices for battery maintenance and testing except visual inspections Enables extended replacement intervals by basing replacement on the condition of the batteries rather than arbitrarily timed schedules Provides documentation to support warranty claims Detects and mitigates catastrophic conditions including thermal runaway Minimizes shock, arch-flash, burn and chemical risks by reducing personnel exposure to batteries Meets the rigorous safety requirements for test and measurement equipment under UL 61010-1 ACT Helps you take the right action with confidence at the right time by recommending the best corrective action Albér Battery Monitoring Systems provide the ability to make smarter and faster decisions resulting in higher availability, reduced costs, and ultimate confidence in your batteries. Improved Compliance Allows users to comply with International Fire Code (IFC) 608.3 by providing the ability to detect and control thermal runaway Provides documentation to demonstrate compliance with regulatory standards 3

ALBÉR BDSUI AND ALBÉR BDSU-50 See Issues Sooner By providing real-time system and component level visibility, Albér battery monitoring systems unique approach provides warning of imminent battery failures months in advance. COMPONENTS OF A BATTERY SYSTEM S OHMIC PATH Electro-chemical path Internal Cell Metallic path Inter-Cell (cell-to-cell) Inter-Tier Disconnect Switches (Center Breakers) Albér Brand B Brand Ca x x x Brand Ce x x x Brand M x x x Brand P x x x Electro-chemical path Albér Albér systems patented DC resistance test method (ohmic measurement process) uses a native DC current and a higher test current to provide earlier warning of approaching failures by maximizing accuracy and repeatability. Competition By using an AC (non-native) current and a lower test current, AC tests are very susceptible to ripple currents and electrical noise produced by the load and/or aging capacitors resulting in poor accuracy and repeatability. Ohmic Measurements Metallic path Albér Since batteries are DC devices, a DC resistance test method (ohmic measurement process) measures a battery s entire metallic path of an individual battery including the plates/ grids which constitute a significant portion of the total resistance of an individual battery. Competition Since AC testing is an abnormal battery condition, AC tests are unable to accurately measure the metallic path of plates/grids The measurement of the electronic and ionic conduction path within a battery cell, commonly known as the ohmic value of a cell, is closely related to its capacity and can be used to predict the battery cell s performance during a discharge. Even though there is a close correlation between a battery cell s ohmic value and its capacity, it is not completely linear. Therefore, ohmic measurements are not used as a direct indicator of capacity. Rather, they are used as a warning indicator that signals if a battery cell has deteriorated to a level that will affect the operating integrity of the overall battery system. Rest of the system Albér Since the battery monitor modules in Albér systems centralized architecture obtain power from a UPS protected AC power source, an Albér battery monitoring system is able to verify the integrity of the entire battery system by measuring the inter-cell, inter-tier/ inter-row/inter-shelf, and disconnect switch (central breaker) resistances. Competition Most of the competition utilizes a distributed (modular) architecture in which the battery monitoring modules obtain power directly from the batteries being monitored. Not only does this have an adverse impact on the lives of the batteries due to voltage imbalances caused by the modules, but distributed (modular) systems are unable to measure the other components of a battery system beyond the individual cells or jars themselves. 4

Management Software Albér systems user-friendly management software translates data into actionable insights to maximize the availability of critical power systems dependent on stationary back-up batteries. The simple, intuitive software allows users to set thresholds and alarm notifications, view graphs and trends, and generate reports. The reports have built-in decision support that analyzes the data and provides suggestions for the best course of action. Albér Battery Xplorer (standard) is ideally suited for single site users with a few strings of batteries while Albér Battery Xplorer Enterprise (optional) is ideal for multi-site users with many strings of batteries. System View Alarm View String View View a trend graph showing the history of all the string level parameters Discharge View View data on parallel battery strings simultaneously View active alarms in a sortable and customizable grid View data captured during a discharge event FEATURE ALBÉR BATTERY XPLORER (STANDARD) ALBÉR BATTERY XPLORER ENTERPRISE (OPTIONAL) ALBÉR BATTERY XPLORER ENTERPRISE ADVANTAGE OVER ALBÉR BATTERY XPLORER Platform Windows OS WEB OS independent Setup and Configuration Not Applicable Diagnostics and Service Not Applicable Real-Time Monitoring Comparable level of functionality Alarm & Event Management Automatically centralizes alarms across multiple sites or systems and provides the ability to customize notifications Report Generation Comparable level of functionality Data Management Data Integration Aggregates data from multiple sites or systems and stores it in a centralized database Integrates data from other Albér stationary battery monitoring systems and Albér portable battery testing equipment Multi-Site Navigation Easily navigate across multiple sites and systems 5

ALBÉR BDSUI AND ALBÉR BDSU-50 Hardware Designed in accordance with the Institute of Electrical and Electronics Engineers (IEEE) recommendations for battery monitoring, maintenance, and testing, the Albér BDSUi and Albér BDSU-50 Battery Monitoring Systems are ideally suited for 12 and 16 volt sealed battery applications. The Albér BDSU-50 is designed to be mounted on top of any brand of UPS battery cabinet or open rack while the Albér BDSUi is designed specifically to integrate into Liebert UPS battery cabinets. An Albér Battery Monitoring System continuously scans and trends all critical battery parameters, providing detailed reports identifying probable root causes and recommended corrective actions. The result: a reliable, effective system that is efficient to deploy and intuitive to use. The systems consist of two primary components: yalbér Universal Xplorer Control Module (UXCM) a controller that stores the data, provides alarms, power and communication connections. Albér Universal Xplorer Battery Module (UXBM/50) yalbér Universal Xplorer Battery Module (UXBM/50) a battery module that measures all significant battery parameters and performs a patented DC resistance test (ohmic measurement process) to verify the integrity of the entire battery system. Albér Universal Xplorer Control Module (UXCM) The first battery cabinet utilizes one Albér UXCM module and one Albér UXBM/50 module. Each additional battery cabinet uses only one Albér UXBM/50 module linked to the single Albér UXCM module on the first battery cabinet. An Albér UXCM can communicate with up to eight Albér UXBM/50 module or battery cabinets. The Albér BDSUi is factory installed and tested inside Liebert UPS battery cabinets, eliminating the concerns associated with field installation. Since the Albér BDSUi is powered directly from the AC output bus of the UPS, it also eliminates the need to provide an external, protected AC power source. The Albér BDSUi is ideally suited for Liebert UPS external battery cabinets for 12V and 16V sealed battery applications: yliebert NXL UPS yliebert exl UPS yliebert NX 225-600 kva UPS yliebert exm UPS 6

Communication Communication network connections are made by the Vertiv IS-UNITY-DP communication card, providing options for industry standard protocols. The card provides the ability to communicate with third-party Building Management Systems (BMS) and Network Management Systems (NMS). The web card protocol enables users to connect to the battery monitoring system via a web interface, premitting quick, real-time viewing of system status and alarms without the PC-based Battery Xplorer software. Standalone Battery Xplorer (BX) FIBER OPTIC UXBM/50 - Battery Module UXCM - Battery Monitor Controller RX TX 24V AC Enterprise Remote Battery Xplorer Enterprise (BXE) UXBM/50 Battery Module Cabinet #2 Up to 50 12V, or 30 16V Jars Cabinet #3-6 Up to 50 12V, or 30 16V Jars UXBM/50 Battery Module Cabinet #7 Up to 50 12V, or30 16V Jars Building Management MODBUS/SNMP UXBM/50 Battery Module Cabinet #8 Up to 50 12V, or 30 16V Jars - Each UXBM/50 Features: Ambient Temperature, Discharge and Ripple Current, Float Current, and Thermal Runaway Control * After being founded over 40 years ago, Albér systems continue to set the standard for monitoring and testing stationary batteries used in data center, industrial, telecommunication and utility applications. The company offers a full line of battery monitoring systems, portable and capacity test equipment and educational services. For more information about Albér products and services, please visit www.vertivco.com Specifications Module Level Measurements yindividual Module Resistance yindividual Module Voltage System Level Measurements yoverall Volts ystring current (Discharge, Float is optional) yripple Current yambient Temperatures yintertier/inter-row/inter-shelf Cable Resistance ymid String Disconnect Switch Resistance Power y3.6 amps at 115 VAC ±10% 60Hz or 1.8 amps at 230 VAC ±10% 60Hz yconfigurations: 12-volt or 16-volt jars Outputs y24 VAC power: For up to eight UXBM/50 units yalarm contacts: Two Form C: Assignable as Maintenance or Critical, Programmable for latching or non-latching Communication yethernet / Modbus TCP / BACnet IP / SNMPv1, v2c, v3 / Vertiv Protocol / HTTP / Email / SMS / Modbus RTU /BACnet MSTP Software ybattery Xplorer / Battery Xplorer Enterprise (Optional) Operating Environment ytemperature range: 5 C to 40 C (41 F to 104 F) yhumidity Range: y0% to 80% RH (non condensing) at 5 C to 31 C y0% to 50% RH (non condensing) at 32 C to 40 C yaltitude: 0 to 2000 meters above sea level yindoor use only Parameters/Features ynumber of cell channels: Up to eight strings of 40, 12 volt jars, six strings of 50, 12 volt jars or eight strings of 30, 16 volt jars Monobloc Voltage y12v range 0 to 18V 0.1% ±12mV y16v range 0 to 24V 0.1% ±16mV Internal Cell Resistance y0 to 32,000μΩ, 5% of reading ±2μΩ Dimensions and Weights: Albér Universal Xplorer Control Module (UXCM): y2u chassis ydimensions: 17.00"W x 3.49"H x 12.00"D yweight: 18.25 lbs. Albér Universal Xplorer Battery Module (UXBM/50): y1u chassis y17.00"w x 1.74"H x 12.00"D yweight: 8.50 lbs. yagency Approvals yul listed yce approved 7

VertivCo.com Vertiv Headquarters, 1050 Dearborn Drive, Columbus, OH, 43085, USA 2016 Vertiv Co. All rights reserved. Vertiv, the Vertiv logo are trademarks or registered trademarks of Vertiv Co. All other names and logos referred to are trade names, trademarks or registered trademarks of their respective owners. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Co. assumes no responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice. SL-29207 (R12/16)