GLO GT416. Benchtop Centrifuge. User s Manual. Glotech Co., Ltd

Similar documents
1580R User s Manual. Multi-Purpose, High Speed Centrifuge. Gyrozen Co., Ltd.

1236R User s Manual. Multi-Purpose, High Speed Centrifuge

624R User s Manual. Compact Bench-Top Refrigerated Centrifuge

Multi-Purpose, High Speed Centrifuge 1248R/1580R User s Manual

BlueSpin Cryo. (Cat. No. BSD-CRYO)

Operating Manual Cellspin

Operation Manual Supra R22

Low Speed Centrifuge. Large capacity Swing out rotor takes 12 x 15mL Conical tubes, 4 x 100mL tubes or 20 vacu-tainers

Large Capacity, High-Speed Centrifuge

Clinical, Low-Speed Centrifuge. Clinical, Low-Speed Centrifuge. Applications. 59 Order & Inquiry /

1248/R, 1236R, 1580/R

1236R // 1248R LOW. capacity. HIGH G-Force High g-force 25,910 x g for fast centrifugation and efficient separation FAST HIGH

Large Capacity, High-Speed Centrifuge

CONTENTS. 3 MAINTENANCE 3.1 Service and Maintenance Maintenance and cleaning Glass breakage Disinfection

Micro. Centrifuges.

ScanFuge Centrifuges for IVF

Instruction Manual for Table Top Centrifuge Z 366

Instruction Manual for Table Top Refrigerated Centrifuge Z 36 HK

Supra R30. High Speed Centrifuges. High Speed Centrifuge. Supra R30 / Supra R22 / Supra R17 / Supra R12

MICRO CENTRIFUGES. Experts in Laboratory Equipment

BLOOD BANK REFRIGERATED CENTRIFUGE

LABORATORY LOW SPEED CENTRIFUGE

Simple design with easy-to-use features

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

LABORATORY LOW SPEED REFRIGERATED CENTRIFUGE

DM0636 Multi-purpose Centrifuge

OPERATING MANUAL. Mega 17R HIGH SPEED REFRIGERATED CENTRIFUGE HANIL SCIENCE INDUSTRIAL CO., LTD. PRINTED IN KOREA

XCM12 Mini-Centrifuge

High Speed Micro-Centrifuge User manual

Packed with new features

OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION.

swing-out rotor MULTIBAS+

PrO-ASTM Centrifuges. Centurion. C1015 Micro Prime Centrifuge. A Micro that offers: Oil testing. Petroleum testing, ASTM methods

PrO-Ed Centrifuges. Centurion. C1015 Micro Prime Centrifuge. A Micro that offers: Education, Schools. C1015. (230V 50/60Hz). 1.C1015.

Bio Lion Table Top Centrifuge XC-L5

HIGH SPEED REFRIGERATED CENTRIFUGE.

EBA 21 Small Centrifuge

Rugged steel cabinet construction ensures quiet operation and long term reliability.

Thermo Scientific Heraeus Primo and Primo R Centrifuges. Flexible and efficient, compact high-performance centrifuges

MIKRO R HETTICH DATA SHEET MICROLITRE CENTRIFUGES FASTER RESULTS IN MOLECULAR BIOLOGY FEATURES HIGHLIGHTS

D2012 & D2012 plus High Speed Mini Centrifuge

USER MANUAL. D2012 High Speed Mini Micro-Centrifuge SCILOGEX, LLC.

Bio Lion Table Top Centrifuge XC-H165

PrO-Vet Centrifuges. Centurion. Veterinary, Equine & Cytology. Scientific Limited

Heal Force Multipurpose Centrifugeses

D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge DLAB Laboratory Instruments Limited

Thermo Scientific Heraeus Primo and Primo R Centrifuges. Flexible and efficient, compact high-performance centrifuges


INSTRUCTION MANUAL FOR BENCH TOP CENTRIFUGE Z 200 A

Combi R515. Multi-purpose Centrifuges. Multi-purpose Centrifuge. Combi R515 / Combi 508

Supra 22K. Silence Safety Speed. Features. High Speed Centrifuge. Ergonomically designed model of High Speed Centrifuge.

It s Your Turn. Eppendorf Centrifuge 5702, 5702 R and 5702 RH

PrO-Cyto Centrifuges 61

REFRIGERATED CENTRIFUGE. LRF-A1 Series

3 Liter Programmable Centrifuges

REFRIGERATED CENTRIFUGE. LRF-A2 Series

USER MANUAL PRF DUO. Clinical Centrifuge. Before using centrifuge, please carefully read this user manual for efficient operation and safety.

DM1424 Hematocrit Centrifuge

EBA 21. Small Centrifuge

MODEL 853VES. Model 853VES Operator s Manual. Laboratory Centrifuge IVD

EBA 21. Benchtop Centrifuge

Extremely quiet due to unique flexible drive system. Super High-Speed Centrifuge. Refrigerated - 30,000 rpm / 70,434 xg

STANDARD OPERATING PROCEDURES SOP: 1002 PAGE: 1 of 5 REV: 0.0 DATE: 12/23/96

INSTRUCTION MANUAL. CAT Place Table Top Centrifuge

Max. 22,000 rpm / 48,700 xg, full 3 liter capacity

UNIVERSAL 320/320 R Benchtop Centrifuges classic/cooled

Instruction Manual for the Z 216 MK Refrigerated Microcentrifuge

Instruction Manual for Table Top Centrifuge Z 366

MODEL 853VES Model 853VES Operator s Manual

Operating Manual. Multi Purpose Centrifuge Combi - 514R

USER MANUAL. D3024 & D3024R High Speed (Refrigerated) Micro-Centrifuge SCILOGEX, LLC.

Multi-Purpose Rotor & Micro Rotor can be used in this convenient unit.

Clinical Centrifuge. Before using centrifuge, please carefully read this user manual for efficient operation and safety.

air-cooled 18,000 rpm 25,356 xg 24,000 rpm 45,078 xg refrigerated Table-Top High-Speed Centrifuges High performance instrument for the daily routine

Centrifuge. Model XC-2000 Operating Manual

ROTINA 420/420 R Benchtop Centrifuges classic/cooled

Instruction Manual. Labnet Spectrafuge 7M Microcentrifuge

MODEL 755VES Model 755VES Operator s Manual

Large Centrifuge. Continent 512R I Continent 512R Plus I Combi 514R I Combi 408. Large Centrifuge

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

Instruction Manual for Compact Centrifuge Z 206 A

Jouan B4i Multifunction Centrifuge Series


Centrifuge Operator / Service Manual

Universal Centrifuge 320/320R

The VELOCITY Range BENCH TOP CENTRIFUGES

Mini Micro Centrifuges

Centrifuge 5804 / 5804 R / 5810 / 5810 R. Instruction Manual Mode d'emploi succinct Instrucciones breves

Frontier TM Centrifuge FC5515 / FC5515R Instruction Manual

ROTINA 380 /380R Benchtop Centrifuges classic/cooled

Instructions for Using Micro Plus Multiwell Plate Carriers

Benchtop Low Speed Centrifuge. Labocon Scientific Limited

OPERATION MANUAL OM3121

ISO-9001:2008 CENTRIFUGES CATALOG. Phone: Fax: Web: expotechusa.com

Immunity: EN capacity 75 µl Capillaries. 1,5 x 75 mm. Rotor and Lid as evaluation disc incl.

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

SORVALL. Evolution OPERATING INSTRUCTIONS PN

Centrifuge. Model XC-1000 Operating Manual

Thermo Scientific Heraeus Multifuge 1 Benchtop Centrifuges. Versatile centrifugation for demanding laboratories

MIKRO 185 HETTICH DATA SHEET MICROLITRE CENTRIFUGE SMALL FOOTPRINT WITH UNMATCHED CAPACITY FEATURES HIGHLIGHTS

Transcription:

Benchtop Centrifuge GLO GT416 User s Manual Glotech Co., Ltd

Contents 1. GLO GT416G Performance 2. Precautions 3. Technical Specifications 4. Installation 4 1. Delivery Checklist 4 2. Unpacking the Instrument 4 3. Installation Place 4 4. Supply the Power 4 5. On/off and the door open 4 6. Rotor coupling and disassembling 5. Operation 5 1. Control Panel 5 2. Function Description 5 3. Operation Sequence 5 4. Miscellaneous Functions 6. Maintenance 7. Trouble Shooting 8. Ordering Information

1. Performance Compact design with automatic door release Max. 4,000 rpm/2,826 g, Time setting to 99 min 59 sec or continuous Rapid acceleration and deceleration SOFT start/stop function for gentle acceleration/deceleration Digital display of speed and remaining time Automatic RPM/RCF conversion Automatic recognition and alarms for imbalance, over speed and over heat Program memory for up to 10 Unique air flow cooling internal design Three layered safe door with auto lock function Complete with autoclavable, fixed angle rotor (16 x 15 ml tubes) or swing out rotor (4 wings or 6 wings) with buckets (50 ml, 15 ml, 2 x 15 ml, etc) A range of adaptors being available for both rotors for tubes from 3 ml to 15 ml

1 1. Delivery Checklist GLO GT416G Existing Type Comparison of centrifugation. Centrifugal separation of blood in the direction of action. Blood seokim After centrifugation Rotor Swing out Rotor Fixed angle Rotor Product

2. Precautions The instrument must be installed on a flat, stable, horizontal and solid surface. Before operating the instrument, check if the rotor and the rotor lid are securely fastened. Do not move the instrument when it is not completely stopped. Operate with a stable & appropriate power inlet. Do not place dangerous materials within 30cm distance around the instrument. Only use rotors from Glotech Co., Ltd. with appropriate tubes for centrifugation. Do not use hazardous, inflammable or radioactive materials as samples. When it is necessary to use toxic or radioactive materials or pathogenic micro organisms which belong to the Risk Group II of WHO: Laboratory Bio safety Manual, follows national regulations. Use the emergency door open function only when the door key on the control panel is not working. The sample must be loaded weight balanced way not to cause imbalance. The density of sample material must not exceed 1.2g/ml at Max. RPM or RCF. Any improper handling or any usage of un qualified accessories is not able to be protected. 3. Technical Specifications GLO GT416 Max. RPM 4,000 rpm Max. RCF 2,848 xg Max. capacity 10ml x 4 Run time 99 min 59 sec or continuous Noise level 60 db Acceleration time 20 sec Deceleration time 25 sec Program memory 10 Imbalance Recognition Automatic Motor High torque AC induction motor Safety Lid lock Power & Frequency AC 220 230V, 50/60Hz Dimension (WxDxH) mm 375 x 480 x 260 Weight 19.5 Kg CE Certification Yes

4. Installation 4 1. Delivery Checklist 4 1 1. Main body, 1ea 4 1 2. Power cable, 1ea 4 1 3. Emergency door open tool, 1ea 4 1 4. User s manual, 1ea 4 1 5. Rotor 1 set 4 1 5. Rotor locking tool, 1ea 4 2. Unpacking the instrument 4 2 1. Open the box and lift out the instrument carefully together with the safety padding. 4 2 2. Remove the safety padding and vinyl wrap. 4 2 3. Place the instrument on the flat space. 4 3. Installation place 4 3 1. Install the machine at the solid and flat floor or table. If you place the centrifuge at the slope, the axis of rotation is possibly changed because of the rotor weight. 4 3 2. Install the machine about 30cm is departed from the wall because of the air circulation. 4 3 3. Install the machine at the place with appropriate temperature and humidity. It also has to be maintained with the proper temperature & humidity. 4 3 4. Install the machine at the place without any kinds of corrosive gases. 4 4. Supply the power 4 4 1. 416G model uses 110V or 220V. Check proper voltage of your instrument and connect to adequate power outlet. 4 4 2. If the power input is more than +/ 10% of the recommended voltage or fluctuating frequently, it may affect some functions of the instrument. It is advised to use AVR (Automatic Voltage Regulator). 4 4 3. If you want to use the instrument at other voltage range, please contact us. * The instrument is delivered filling with protection padding inside the chamber. If you start operation without removing the protection padding, Error 9 is appeared because the rotor cannot rotate. In this case, open the door manually using the emergency door open function refer to section 4 4 1 and remove the protection padding. Mount the rotor and turn on again. 4 5. On/off and the door open 4 5 1. Turn on the instrument by pressing the switch on the right side of the machine. 4 5 2. Press the Door button to open the door. 3 5 3. Remove the protection materials inside the chamber. 4 6. Rotor coupling and disassembling 4 6 1. Mount the rotor fitting with the motor shaft. 4 6 2. Grasp the rotor with one hand, and rotate the rotor nut in the direction of clockwise, until it is tightly assembled. 4 6 3. To disassemble the rotor, rotate the rotor nut in a counterclockwise direction.

5. Operation 5 1. Control Panel 5 1 1. Display FND: Shows the data of each function. 5 1 2. Up & down arrow: Uses to change input data. 5 1 3. Door: Uses to open the door. 5 1 4. RPM/RCF: Uses to switch the RPM/RCF display 5 1 5. TIME: Uses to set test time up to 99 min 59 sec (00: continuous) 5 1 6. START/STOP: Uses to start & stop operation. 5 1 7. PROG: Use to save a set of setting values or call the saved setting values. 5 1 8. SOFT START & STOP: Uses to accelerate or decelerate slowly. *If you press the arrow button longer than 3 seconds, the numbers change very rapidly and the set up is achieved faster. 5 2. Function Description 5 2 1. RPM Speed display unit : 10 rpm Speed setting unit : 10 rpm Speed accuracy : <± 2% (at maximum speed) 1Press the RPM/RCF button. 2Press the arrow button to change input value. 5 2 2. RCF (Relative Centrifugal Force) The conversion value from RPM to RCF is calculated automatically (based on the maximum radius and revolution) 1Press the RPM/RCF button twice. 2Press the arrow button to change input value.

5 2 3. Time Time display: 99 min 59 sec, 2 digit display Time is down counted after starting centrifugation. 1Press the TIME button. The display shows the previous time value and the minute LED and value blinks. 2Press the arrow button to change the minute value. 3Press the TIME button again to set the second value, then the second LED and value blinks automatically. 4Press the arrow button to change the second value. * After finishing the setting, your input value is saved automatically in 2~3 seconds. 5 2 4. Soft Start & Stop For the sensitive samples not to disturb contents by fast acceleration and deceleration, use SOFT START/STOP. Centrifuge is accelerated or decelerated slowly. Press SOFT START / STOP button instead of START button to use this function. 5 2 5. Program saving & recalling Use to save a set of setting values or call the saved setting values [Saving or Editing] 1 Press the PROG button longer than 2 seconds for saving your preferred set of the test values. 2 Check the message of PROGRAM SAVE: ## at the display, and any number of ## blinks. 3 Press the arrow button and select a number between 01 ~10. 4 Press the Enter button to complete the saving or editing. [Recalling] 1 To retrieve the saved program, just press the PROG shortly. Check the message of PROGRAM CALL: ## at the display. Choose the number with the arrow button, and then press the Enter button. 5 2 6. Door Press the Door button to open the door. The door is not opened while the instrument is running. 5 2 7. START / STOP Pressing the Start / Stop button, the operation is started to run with setting or stopped to run in any case.. 5 3. Operation Sequence 5 3 1. Connect the AC cord to the appropriate voltage. 5 3 2. Turn on the power switch located at the right side of the unit. Then the latest operating values are recalled with beeping sound. 5 3 3. Open the door and check the rotor. 5 3 4. Input the function values according to your preferences. 5 3 5. Press the START button to start the operation. 5 3 6. As soon as the set time is ended, the centrifugation will be ceased according to the setdeceleration level. If you want to interrupt before the set time, press the STOP button.

5 4. Miscellaneous Functions 5 4 1. In any cases needed for emergency open, you can use the emergency door open tool as long as the machine is idle. Insert the emergency tool into the emergency door open hole at the left upside of the unit. 5 4 2. Imbalance Alarm: When the rotor is imbalanced and the vibration is severe, the operation is urgently stopped with the error message on the display and the alarming sound. 6. Maintenance 6 1. Outer part of instrument 6 1 1. Clean the outside of the machine with a dry soft cloth. If necessary, dip the cloth with neutral detergents and clean contaminated parts. Keep completely dry after cleaning. 6 1 2. Do not use any volatile chemicals such as alcohol, benzene, etc. 6 1 3. If any rust appears, clean with neutral detergents and dry it. 6 2. Inner part of instrument 6 2 1. Keep dry inside the chamber after every use of the machine. 6 2 2. Clean the shaft always for avoiding an imbalance during the rotation. 6 2 3. If any part is contaminated, clean with neutral detergents. 6 3. Rotor 6 3 1. Clean the rotor if any parts are contaminated with samples. 6 3 2. Keep dry after usage. 6 4. Moving or shipping of instrument 6 4 1. If you need to move or ship the instrument, be cautious to protect the shaft from any physical impact. 6 4 2. Remove the rotor and fill inside the chamber with proper materials to keep the shaft on place. 6 4 3. It is recommended to move or ship rotors separately if no original safety padding is available.

7. Trouble Shooting Error Possible Causes Actions E 1 Failure to reach to 200RPM within 2sec. Check the RPM sensor. Check the connection of a RPM connector or a wire.* E 2 When running, the door is opened. Check the door latch. Stop running, power off and on. E 3 Over temperature of motor. Check the motor temperature. E 4 Low voltage Check supply voltage. Use AVR to provide proper voltage. E 5 High voltage Check supply voltage. Use AVR to provide proper voltage. E 6 Over speed Stop running, power off and on. Tuning of the firmware(download)* E 7 Failure of control system Stop running, power off and on. Tuning of the firmware(download)* E 8 Imbalance Check amount of samples. Check weight balances of samples. E 9 RPM sensor recognition error Check attached place of RPM sensor. Check connection of cable for RPM sensor. Change RPM sensor. * Any wire disconnection or tuning of the instrument must be performed only by a service engineer who is authorized by Glotech Co., Ltd. 8. Ordering Information Cat No. Product Description Capacity G1 7514 201 GLO GT416 Main Body, without Rotor Rotors & Accessories for GLO GT416 T1 111 010 Swing Rotor, GRS 10 4, includes 4 Buckets, GLB 10 4 x 10 ml T1 111 090 Bucket, GLB 10, 10 ml