SPECIFICATION SHEET 1. APPLICATION H/P & Cooling Type Air conditioner Rated & Frequency... 208~230V 1Φ 60Hz Refrigerant.. R-22 2. COMPRESSOR DATA Pump Type Rolling Piston Type Displacement. 33.43cc/rev Oil Type NOC(ATMOS-NM56EP) & SUN OIL(Suniso-4GSD) Initial Charged. 750cc Net Weight(Included Oil).....19.9kg Painting.. Black Suction Tube I.D.... 16.03mm Discharge Tube I.D. 9.70 mm 3. MOTOR DATA Motor Type.. Permanent Split Capacitor Locked Rotor Amps.. 55.0Amp at 230 V Motor Resistance. Main Winding : 1.07 Ohm at 20 Sub Winding : 2.01 Ohm at 20 Insulation Class E Class 4. ELECTRICAL COMPONENTS Overload Protector... INTERNAL Running Capacitor... 45uF / 450 VAC
SPECIFICATION SHEET 5.NOMINAL PERFORMANCE (V) 208 220 230 Note Cooling Capa. (Btu/h) 24,655 24,844 24,500 - Running Current (A) 10.92 10.46 10.00 - Input (W) 2,234 2,259 2,220 - EER (Btu/W.h) 11.03 11.00 11.00 - Noise (dba) - - 63.0 Max of 4 point measurement at 90cm from surface Vibration (µm) - - 70.0 Larger tangential vibration displacement at 90 & 180 points RATING CONDITION Condensing Temperature. 54.4 (130 F ) Evaporating Temperature. 7.2 ( 45 F ) Return Gas Temperature.. 35.0 ( 95 F ) Liquid Temperature.. 46.1 (115 F ) Ambient Temperature... 35.0 ( 95 F ) Compressor Cooling. 1 m/s air cooling * Return Gas Temp. for Noise & Vibration is 15.0 ( 59 F ) 6.GENERAL CHARACTERISTICS No Item Characteristics 1 2 3 Operating voltage range Starting voltage Hydrostatic pressure rise Within ±10% of the rated voltage No less than 85% of the rated voltage at compressor terminal in pressure balancing condition Max. 145 kg/ cm2.g 4 Residual moisture/residual impurities 80 mg Max / 50 mg Max 5 Insulation resistance 50 MΩ min (with 500 V DC mega tester) 6 Withstand voltage At 1800 V/sec(1250 v/min)leakage current is less than 2.5 ma
APPLICATION SHEET No Item Operational standards and limits 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Quantity of refrigerant charge Condensing temp (pressure) Evaporating temp (pressure) Compression ratio Suction gas superheat Liquid subcool Discharge gas temp. Max. 115 Motor winding temp. Bottom shell temperature Abnormal pressure rise On-Off cycle Oil level Vibration of tubing Tube stress Spacing of tubing Length of tubing Height difference of tubing Tilt of operation Storage External shock Prohibition of air or vacuum operating Terminal Cover & Nut Fasten Torque Split type:max. 1,990g / Window type:max. 1,390g (Need to the special discussion in case of excess) 28 ~ 65 (10.50 ~ 26.51 kg/ cm2.g) -25 ~ +12.7 (1.02 ~ 6.50 kg/ cm2.g) 2 ~ 8 Sufficient superheat is proffered for preventing liquid flood back Sufficient liquid subcool is proffered Max. 130 Min. 5 higher than condensing temp. Max. 48.0 kg / cm2 G On/Off= Min. 3 Minutes / Min. 3 Minutes Total 200,000 cycles Steady-state : higher than 5mm based bottom plane of cylinder Transient-state : higher than bottom plane of bottom flange Tubing vibration displacement : Max 0.8mm (±10% of rated voltage) If the resonance of the pipe can be checked, above condition is not necessary Starting & stop : less than 3.5 kg/ mm2 Normal operating : less than 1.25 kg/ mm2 Between tube and moving parts : Min. 13.0 mm Between tube and non-moving parts : Min. 10.0 mm Max. 15m between indoor and outdoor sections (Need to the special discussion in case of excess) Max. 7m between indoor and outdoor sections (Need to the special discussion in case of excess) The allowable tilt of compressor under operation should be 5 or less Do not open compressor rubber plugs more than 10 minutes before use Max. storage time : 1 year from manufacturing External shock should be less than 60 G Do not operate the compressor in air or vacuum 15±5 kgf- cm
APPLICATION ENVELOPE
PERFORMANCE CURVE BASED ON SUCTION TEMP. : 35 (95 F) SUB COOL TEMP. : 8.3 (15 F) AMBIENT TEMP. : 35 (95 F) VOLTAGE : 230V
OUTDRAWING DIMENSION The foot angle is +30 degree from horizontal line that connecting compressor body center with accumulator center. UNIT: mm MODEL NO. DIMENSIONS Accum (O.D) A B(±3.0) C D E J K F TUBE (I.D) G(±0.15) H(±0.15) 55A240IUBEM 282.9 124.8 346.2 35.0 15.0 15.0 56.2 77.4 9.70 16.03
ACCESSORY DIMENSION ITEM COVER TERMINAL PART NO. DB63-02310A Q'TY 1 REMARK - Material : SABIC N1250 - Color : Black - UL 94, 5VA nonflammable property shall be satisfied.
ACCESSORY DIMENSION ITEM OLP - SPRING PART NO. - Q'TY - REMARK - ITEM GROMMET ISOLATOR PART NO. DB63-00801A Q'TY 3 REMARK - Material : NR - Hardness : 40 ±4
ACCESSORY DIMENSION ITEM NUT PART NO. 6021-001142 Q'TY 1 REMARK -Material : SWCH10A ITEM GASKET PART NO. DB63-00817A Q'TY 1 REMARK - Material : EPDM RUBBER - Hardness : 80-85 - Thickness : 0.8 ± 0.2
ACCESSORY DIMENSION ITEM OVERLOAD PROTECTOR (OLP) PART NO. Q'TY - REMARK INTERNAL ITEM MOUNTING TYPE (1 FOOT TYPE) PART NO. Q'TY 1 REMARK A B C D 25.5 mm 0.5 ~ 2.0 mm 33.5 mm 11.5 mm
WIRING DIAGRAM
STANDARD EXPORT PACKING IN 20 FEET CONTAINER FRAME 55F Compressor Q ty / Carton 1 step 1 (pcs) 20 2 step 2 (pcs) 40 Carton Q ty (20Ft) 1 step 3 (Carton) 2 step 4 (Carton) Accessory Box 5 (Carton) Loading Quantity 6 (pcs) 4 16 3 720 Total Compressor Q ty = 1 * 3 + 2 * 4 = 6 (720 pcs)
A/C SET TEST DATA Please, fill in the below to check whether is applied or not the exact compressor to your A/C. 1. General data No Item 1 Air conditioner model name 2 Compressor name Data 3 Refrigerant volume Standard ( kg ). Max ( kg ) 4 Length of tubing (m) 5 Height difference of tubing (m) 6 Air conditioner Type Window ( ) or Split ( ) / Cooling ( ) or H/P ( ) 7 Sales area 2. Data in overload running condition & low temperature's No Condition Data 1 Overload running Item Cooling Indoor temp. DB/WB : / Out door temp. DB/WB : / Heating DB/WB : / DB/WB : / Item Low Cooling Rated High Volatage Low Heat pump Rated High Volatage (V) Input (W) Current (A) T-coil( ) T-top ( ) T-dis ( ) T-suction( ) T-cond ( ) T-eva ( ) High pressure ( kg / cm2.g) Low pressure ( kg / cm2.g)
No Condition Data 2 Low Temp. running Item Indoor temp. Out door temp. Cooling DB/WB : / DB/WB : / Heating DB/WB : / DB/WB : / Cooling Heat pump Low Rated High Volatage Low Rated High Volatage (V) Input (W) Current (A) T-coil( ) T-top ( ) T-dis ( ) T-suction( ) T-cond ( ) T-eva ( ) High pressure ( kg / cm2.g) Low pressure ( kg / cm2.g) 3. Starting ability data & stall's Items Judgment Test voltage (V) Test Current (A) High pressure ( kg / cm2.g) Low pressure ( kg / cm2.g) T-top ( ) Restarting ability after overload running Starting ability in soaking condition (Nekomi) 4. Electirc parts specification Electric parts OK ( ) NG ( ) OK ( ) NG ( ) Stall OK ( ) NG ( ) Running capacitor uf / Vac Starting capacitor uf / Vac Starting relay (Model name : ) PTC relay Ω V (Model name : ) OLP (Model name : )