C1000 Series Automatic Cap Bank

Similar documents
CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Metal-enclosed medium-voltage power factor correction system

Metal-enclosed medium voltage power factor correction system

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Horizontal Circuit Switchers

FIXED POWER FACTOR CORRECTION EQUIPMENT 5KV CLASS MEDIUM VOLTAGE SECTION Z

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Technical Specification For Outdoor Substation Harmonic Filter Banks

EMPAC Metal enclosed capacitor bank for wind applications

SWITCHGEAR DIVISION PRODUCT PROFILES

Ultravar TM AUTOMATIC POWER FACTOR CORRECTION & HARMONIC SOLUTIONS

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

Indoor or Outdoor 2400 to 14,400 Volts 600 to 14,400 Kvac, 3 Phase, 60 Hz

Medium Voltage Metal-Enclosed Switches

Horizontal Circuit Switchers

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Fixed, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Automatic, Medium-Voltage, Pad-Mounted, Three-Phase Power Capacitor Bank Guide Form Specification

Medium Voltage Metal-Enclosed Switches

35-kV Safefront 200 Amp SuperWell Primary Capacitor Station Pad-Mounted Outdoor

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Power Break II Switchboard

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Solid Dielectric, Single Phase Recloser

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

Three-Phase Pole Mounted Recloser

CP Automatic capacitor bank

15-kV Safefront 200 Amp Primary Capacitor Station Pad-Mounted Outdoor

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Design Standard. Capacitor Bank. Detailed specifications follow. PART 1 - GENERAL

STANDARD SPECIFICATION FOR PAD-MOUNTED CAPACITOR BANKS FOR 15kV or 25kV APPLICATIONS

Solid Dielectric, Single Phase Reclosers

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

Solar Power Switchgear & Energy Storage Renewable Energy Systems

SWITCHED POWER FACTOR AND *********HARMONIC CORRECTION EQUIPMENT MEDIUM VOLTAGE SECTION 16280E

Q pole Pole Mounted Capacitor System

Publication No.: PSG

Technical Specification for Pole Mounted Capacitor Rack

SERIES 802 / 812 SPECIFICATION 15KV & 25KV PADMOUNTED LIQUID-INSULATED VACUUM LOAD INTERRUPTERS AND FUSE ASSEMBLIES

35-kV Safefront SuperWell Mini-Switch Source Isolated Pad-Mounted Switchgear 50 Amp (Max) Clip-Mounted Current Limiting Fuses

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Switchgear Skid, C1192

AIR CORE REACTORS. Phoenix Electric Corporation

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

Underground Distribution Switchgear

15-kV Wall-Mount Switchgear Three-Phase Indoor/Outdoor 600 Amp S&C Mini-Rupter Switch

Design Standard. Purpose: Design Standard:

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Technical brochure. The Vector series The ABB comprehensive solution for automatic power factor correction

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

Medium Voltage Capacitors

Automatic COSYS PFC. Automatic power factor correction system NEW

Solid Dielectric, Triple Option Reclosers Catalog O-vst14

Medium Voltage Equipment 5-15 kv GM-SG and 38 kv GM38 Metal-Clad Switchgear General

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Solid Dielectric, Three Phase Reclosers CATALOG VS11

solutions RUS accepted

Solid Dielectric, Independent Pole Operated Reclosers Catalog O-vst16

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Metal Clad VCBs ~ Mk1

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

100 / 110 DRYWELL FUSE SPECIFICATION

Specification Pad-Mounted Capacitor Bank with Dual Fusing Integral Load-Interrupter on Line-Side Fuse Mountings

MEDIUM VOLTAGE AIR INSULATED ARC-RESISTANT LOAD BREAK AND DISCONNECT SWITCHES

SafeGear Motor Control Center Arc Resistant Metal-Clad Construction Descriptive Bulletin

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

LV Capacitor Bank APC

15-kV Live Terminal 600 Amp Group Operated Pad-Mounted Metal-Enclosed Outdoor Switchgear 140 Amp (Max) Clip Mount Current-Limiting Fuses

SafeGear TM Motor Control Center Arc resistant metal-clad construction Motor Control Center Descriptive bulletin

Customer Substation Manual

Gas Insulated Metal-clad Switchgear, HMGS!

Submersible Vacuum Fault Interrupters

Typical Specification

5kV to 38kV, 630 Amp to 4000 Amp Indoor or Outdoor Application

Power System Solutions (PSS)

Visual comparison of Plain & Hazy PP Film

A. Submit manufacturer's literature and technical data before starting work.

Descriptive Bulletin. R-MAG TM magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

Solid Dielectric, Three Phase Reclosers Catalog O-vs18

WARREN COUNTY, N.Y. M/E REFERENCE A. Submit manufacturer's product data on all motors and adjustable speed drives.

BGE STRATEGIC CUSTOMER ENGINEERING

POWER FACTOR CORRECTION MOTOR LOAD (ML) FIXED CAPACITOR

Descriptive Bulletin. R-MAG magnetically actuated dead tank outdoor vacuum circuit breaker 15.5 kv - 38 kv

Westinghouse Electric Corporation Distribution and Control Business Unit Assemblies Division Bloomington, Indiana

Transcription:

C1000 Series Automatic Cap Bank Metal Enclosed - Medium Voltage Capacitors Assemblies Fixed / Auto Medium Voltage 5, 15, 25 and 35 kv Class Customized to your specifications The Reactive Power Solution Gentec Capacitor C1000 Assemblies provide automatic control of main bus power factor, reduce demand on substation transformers, improve main bus voltage and eliminate poor power factor rate penalties. Compact and versatile, Gentec capacitor assemblies are specifically designed to meet the stringent reliability requirements of the main plant substation and distribution system. They also offer improved economy, ease of maintenance and simplified operation. Additionally, Gentec assemblies can be customized to meet your specifications. Gentec provides the most compact and cost effective capacitor assemblies available. Each assembly is a complete power factor correction unit, completely factory tested and assembled prior to shipment. The unit is shipped ready for installation and start-up requiring the user to simply set it in place connect the incoming line, control voltage and CT signal circuits and adjust the settings to the power factor controller. Metal Enclosed Industrial Assemblies Utility Assemblies Pad Mount Assemblies Custom Designed TECHNICAL DATA - C1000 Series Rated Voltage / Phase 5 kv to 25 kv / 3 phases Rated Frequency 50 Hz or 60 Hz Rated Power 20 to 12000 kvar Power Factor Controller 12 steps N12 or NC12 Insulation Level 60-95-125 kv BIL Power Losses 0.5 w/kvar Continuous Overvoltage 110 % Continuous Overcurrent 135 % Mounting Type Floor Mounting Bracket Enclosure Type Indoor and outdoor Temperature Class -40 C to 55 C o Average 24h: + 45 C Color ASA 61 (Light Grey) Construction Standard UL, CSA, IEC

Standard Components Gentec C1000 provides the following items as standard components on all 5 to 25 kv Capacitor Assemblies. Power Capacitors Gentec utilizes single-phase, with single or double bushing power capacitors of welded stainless steel construction with non-pcb dielectric fluid with internal discharge resistors. The capacitors are mounted directly behind hinged access doors for complete visual inspection. The capacitor mounting frame allows individual capacitors to be removed easily, without disturbing adjacent units, by simply removing the lower bolted access panel and tilting the capacitors forward. Individual Capacitor Fuses The capacitors can be individually protected by non-expulsion, capacitor-rated, current limiting fuses with blown fuse pop-up indicators. The individual capacitor fuses are firmly mounted directly to the top of the capacitor bushings (capacitors with internal fuse design are also available with no fuses configuration). Oil or Vacuum Contactor The 5 kv assemblies use a 5 kv, 200 & 400 A continuous (thermal), 60kV BIL, 3-Pole, electrically-operated switches rated for capacitor switching duty. The 15 and 25 kv assemblies use 3, 15 kv, 200 A continuous 95 and 125 kv BIL, single pole electrically-operated vacuum switches and motor operated for oil type. All are rated for capacitor switching duty. The oil or vacuum contactors are located directly behind a hinged access door to allow for inspection. The vacuum contactors can be accessed or uncounted by removing the contactor mounting bolts and the bolted upper access panel. On occasion, the vacuum contactors in 15 kv assemblies may be replaced with three, 15 kv, single-phase oil switches if space is available. Note: Maximum symmetrical short circuit current must be known. Current limiting fuses may be necessary to protect the vacuum contactor from high short circuit currents in excess of 6 ka. Group Fuses When required (with external fuse capacitor design), the group fuses provided are the current limiting, non-expulsion, clip-style type which can provide overall short circuit protection for the entire capacitor bank. Located behind the hinged access doors of the incoming section, the group fuses serve as a means of isolating the entire bank (as well as increasing the contactor fault close rating to 55 ka on 5 kv capacitor assemblies). Damping reactor When required, inrush limiting inductors are provided to limit the high frequency inrush current resulting from energization of the capacitor step under back-to-back switching conditions. Main Bus Used in multiple step banks to feed the individual enclosure modules from the incoming line section. The main bus is insulated has full roundedges, electrical-grade copper bar with 60 kv BIL at 5 kv and 95 kv BIL at 15 kv support insulators. Ground Bus All capacitors assemblies are furnished with a ¼ x 2, round-edge, electrical grade copper bus extending the length of the bank with provisions for the user ground lug attachments inside both end modules. Ground Switch A ground switch is provided as a convenient means to ensure that all stored energy has been discharged from the capacitors while providing maximum safety. The manually operated ground switch, with padlock able handle is key interlocked with the incoming line disconnect and compartment doors to ensure proper sequence of operation. Page 2 of 5

Enclosures The Gentec C1000 Series Enclosures provide a long-lasting corrosion and weather resistant finish with an aesthetic appearance. The enclosures are easily and readily accessible by simply removing front and rear or by opening the front and rear access doors. Door stops limit door swing to 130 and prevent accidental closure. The enclosure provides housing ruggedness, durability and an attractive appearance, with minimal maintenance through the use of #11- gauge formed sheet steel. The enclosures are welded construction. While there are numerous colors from which to choose, standard colors are ANSI No. 61-Light Gray for indoor assemblies and ANSI No. 24- Dark Gray for outdoors units. The 4-inch structural steel base is painted with a paint to prevent corrosion. The enclosures are equipped with four (4) removable lifting lugs. Other features include: Hardware which cannot be removed externally Three-point latching on all doors with single or double door entry Baffled vent panels (outdoor units only) which provide protection against forced entry of foreign objects, weather elements or wildlife Optional pent ahead bolts for additional access restriction Provides adequate space for numerous component configurations Available Options: Gentec will customize standard capacitor assemblies to fit your specifications. The following is a list of available options for Capacitor Assemblies. Incoming Line Options Bottom or top cable entry Bus pad, lugs or cable terminators Roof bushing entry (requires special enclosure) Bushing wells Bank disconnect, 3 single-pole hook-stick Bank disconnect, group-operated Bank fuse, disconnect and non-disconnect style mounting Control / potential transformer (with primary CLF) Current transformer Enclosure Options External NEMA-rated control cabinet Auxiliary control section (part of main enclosure) Remote control cabinet mounting Vented panels Vent fans Key interlock scheme Control Options VAR sensing control (hand-off-auto) Manual control (on-off) Solid-state power factor control Voltage or current control Control cabinet lights and receptacles Blown fuse alarm system Programmable controller Custom micro-processor control Harmonic Filter Systems Custom engineered harmonic filter systems are available to assure a constant level of power quality. Incorporating reactors in series with capacitors will detune or lower the frequency of resonance, assuring efficient capacitor operation. Power factor correction capacitors may be subject to overloading (blown fuse) or failure, due to excessive current and voltage, created by harmonics. A reliable, cost effective solution is to install a harmonic filter system. Application Engineered Iron Core and Air Core Reactors Large Inrush Requirements Page 3 of 5

Industrial Capacitor Assemblies When economy of space is a prime concern, Gentec offers Capacitors Assemblies from 5 kv through 25 kv. The unique Industrial Cap configuration provides a more compact design with multiple step banks. The assembly does not require rear access and can be installed on or next to a wall. Utilizing the same components as standard assemblies, Industrial Capacitors units provide automatic power factor correction for 3 phase, 3 or 4 wire, resistance-grounded, grounded, ungrounded, 60 Hz systems. Each assembly is manufactured in strict accordance with applicable ANSI, IEEE, and NEMA standards. All capacitors are completely built and tested prior to shipment. Space Saver Capacitor assemblies are completely metal enclosed with durable, 11-ga. steel housings. A hinged access door provides front access to all components. Corrosion and tamper resistant construction with 3-point latching system and pad lockable handles insure safety and security in all indoor and outdoor applications. Industrial Cap units are available in fixed kvar manual switching and automatic switching (multistep) configurations. Vertical Stack Capacitor Assemblies (Utility) For constant large capacitance requirements, offers Vertical Stack Capacitor Assemblies. The vertical capacitor configuration reduces metal enclosed unit sizes to a minimum while allowing for higher system ratings with single bank mega VAR capacity. Corrosion and weather resistant 11-ga. formed sheet steel enclosure provides durable protection for all components. Tamper resistant construction with 3- point latching system with padlockable handles is standard to minimize unauthorized entry. Key interlock systems provide additional operator safety... Hinged front panel provides easy access to all components for maintenance or inspection. Each assembly is factory built and tested before actual installation on site. Applicable ANSI, IEEE, and NEMA standards are followed in the design, manufacture and testing of the capacitor assembly. Vertical Stack units may include circuit breakers, special reactors, relay arrangements, and unique design construction, depending on the utility requirements. Vertical Stack Capacitor Assemblies are generally customized to meet you specific requirements and are available from 5 kv through 25 kv for indoor and outdoor applications. Page 4 of 5

Reactive Power C1000 Series Option Basic Part. # System Voltage Reactive kvar No step Step / Kvar Type 1. 12, 3R Protection Device (s) ** Blown Fuse Ind. System Interlock Kvar + -- Suffix Suffix Suffix Suffix Suffix Suffix Suffix Suffix Fig # 1200 C1000 4160 1200 1 1200 1 B BFI KK 1 4800 C1000 12470 4800 8 600 1 B BFI KK 2 6000 C1000 13200 6000 3 2000 1 B BFI KK 2 9000 C1000 13800 9000 1 B BFI KK 2 12000 C1000 25000 12000 1 B BFI 2 *** C1000 *** *** *** *** ** ** ** ** *** Mdl 1 2 3 4 5 6 7 8 9 No C1000 4160 2400 4 600 1 B BFI KK *** Contact Factory OTHERS configuration are available on request ( No cost extra ) 1 C1000 Series for Standard HV Automatic Power Factor Correction 2 3 Total Reactive Power Kvar 4 5 Increment of Kvar / step 6 7 Option : B : Breaker LB : Loadbreak Switch G : Ground Switch 8 9 Model NC12 VAR Controller SWITCH OIL / VACUUM REACTOR DAMPING / FILTER CURRENT LIMITING FUSE CAPACITOR KVAR FEEDER