PRODUCT PRESENTATION PROTECT B.PRO DATA&IT, C-UPS

Similar documents
Liebert PowerSure PSI UPS

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

On-line, Single Phase, Double Conversion UPS

User Manual V1.1 OptiFlex 1100 / OptiFlex 2000

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

The UPS for maximum security in industry and data centre

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Sola/Hevi-Duty S3K Series Mini-Tower UPS

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

PowerValue 11/31 T kva

UPS Multi Power 1-28 x 42 kw up to 1MW

Technical Specification SENTINEL PRO

USER MANUAL DN / DN

User Manual V1.0 MaxiFlex 3000

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

SENTINEL VA

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

3 Uninterruptible Power Systems

User M anual. Rack/Tower Online UPS 1K/1.5K/2K/3K

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

3 Uninterruptible Power Systems

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

FN Series Scalable N+1 UPS 3kVA to 24kVA Rackmount

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

PRODUCT CATALOG (IEC) Low-power UPS. Low-power UPS

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

Master MPS kva kva 3:1 3:3 VFI TYPE

Technical data sheets

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

TECHNICAL DATA SHEET KVA UPS Systemss

Master Plus kva

Series 120/120VAC Universal Tower/Rack Mount

PowerScale TECHNICAL SPECIFICATIONS

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Onfiniti. 1 Phase UPS

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

» Sophisticated» Reliable» Intelligent

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

Centurion 1000/1500/2000/3000 Tower/Rackmount On Line UPS User s manual

1. INTRODUCTION. Features:

Power Supplies 2017 / 2018

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

CP900EPFCLCD User s Manual K

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

Master MPS kva kva 3:1 3:3 VFI TYPE

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Application. Battery. Public Grid GS HYBRID INVERTER

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

3 Uninterruptible Power Systems

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Via Somalia, Cormano (MI) - ITALY Ph Fax:

POWER NEVER ENDS UPS SOLAR INVERTER STANDBY UPS LINE INTERACTIVE UPS ONLINE UPS OFF-GRID INVERTER ON-GRID INVERTER WITH ENERGY STORAGE ACCESSORY

POWER UPS SOLAR INVERTER NEVER ENDS STANDBY UPS LINE INTERACTIVE UPS ONLINE UPS OFF-GRID INVERTER ON-GRID INVERTER WITH ENERGY STORAGE ACCESSORY

YOUR POWER IN SAFE HANDS. E Series UPS

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Liebert GXT MT+ User Manual VA Installer/User Guide

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Est FlexiPower Mini UPS FPX Mini kVA

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Uninterruptible Power System

MINUTEMAN UPS Endeavor Series Product Specifications 5,000VA 10,000VA Single-Phase Uninterruptible Power Supply 1.0 GENERAL

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

Uninterruptible Power System

MINUTEMAN POWER TECHNOLOGIES Endeavor LCD Series Product Specifications 1000VA 3000VA Single-phase Uninterruptible Power Supply 1.

Uninterruptible Power System

Liebert GXT4. Intelligent, Reliable UPS Solution 700VA - 3kVA

Master DIALOG INDUSTRY RANGE

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

1. Important Safety Warning

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Back-UPS Intelligent, reliable protection for your home or small business Certainty in a Connected World

Uninterruptible Power Systems

Model ES VA to VA SINGLE PHASE UNINTERRUPTIBLE POWER SYSTEM

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

Technical Data Sheets

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

Master MPS kva kva 3:1 3:3 VFI TYPE

Technical Data Sheets

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Transcription:

PRODUCT PRESENTATION PROTECT B.PRO DATA&IT, C-UPS

Office, SoHo, IT segment Compact UPS Home, SoHo Surge protection AEG S COMMERCIAL COMPACT-UPS PRODUCT PORTFOLIO AND FIELD APPLICATION PROTECT BASIC Power strip for all standard applications PROTECT HOME 600 VA Complete protection for multimedia applications PROTECT TRAVEL Security on the move for safety charging of your devices PROTECT alpha 450 bis 1200 VA Suitable protection for SoHo applications, telephone equipment, NAS systems, PCs PROTECT ENTERTAINMENT Intelligent protection for entertainment equipment with master-slave-function PROTECT A 500 bis 1400 VA Protection for PCs, workstations and telephone equipment PROTECT TWINPOWER Security for flexible connectivity and safe power supply PROTECT BUSINESS Business solution with surge protection and USB-Charger PROTECT B 500 bis 1500 VA sinusodial outputvoltage, Surge protection for telephone, fax, router and network PROTECT OFFICE Compact protection for PC and peripheral equipment COMPACT- UPS PRODUCT PORTFOLIO PROTECT B.PRO 750 bis 3000 VA Efficient rack / tower UPS for small server and network components with sinusodial output PROTECT C 1000 bis 10000 VA Tower UPS for sensitive netzworks, intranet and internetserver PROTECT D 1000 bis 10000 VA Compact UPS for rack mounted protection of server, network and IT equipment PROTECT 1 10000 bis 20000 VA For small data centres, protection of cash till systems & building facilities PROTECT 1.M 4000 bis 24000 VA Scalable and modular high performance UPS system for the IT sector 2

PROTECT B.PRO CLASSIFICATION ACC. TO UPS PRODUCT NORM IEC 62040-3 1. 2. 3. 4. 5. Voltage Phenomenon Time e.g. IEC UPS Arrester 62040-3 solution solution Outage - blackouts Sags / brownouts Dynamic overvoltage Undervoltage Overvoltage > 10 ms continuous continuous VFD Voltage + Frequency Dependent VI Voltage Independent Classification 3 Offline Classification 2 Line-Interactive CLASSIFICATION Energy Efficiency Solutions 6. 7. 8. 9. Transients (Surge) Frequency variations Voltage distortion (Burst) Voltage harmonics < 4 ms sporadic periodic continuous VFI Voltage + Frequency Independent Classification 1 (true) Online real Double- Conversion Limited protection via UPS (extended protection recommended (10.)) see as well 10. 10. Lightning sporadic Surge- and Overvoltage protection (IEC 60364-5-534) 3

FEATURES / PRODUCT HIGHLIGHTS 4

RACK / TOWER CONVERTIBILITY Rack/ Tower form factor to fit in limited working environment Rotatable LCD display (just pull out/ rotate/ slide in) Always 2U incl. batteries PRODUCT INFO 5

PERFORMANCE MORE POWERFUL SERIES POWER TYPE RATING AT PF = 0.9 LAG FOR ALL PROTECT B.PRO MODELS 750 VA / 675 W 1000 VA / 900 W 1400 VA / 1260 W 1800 VA / 1620 W 2300 VA / 2070 W 3000 VA / 2700 W More power for modern SPS loads Narrow- graded power steps to fit exactly the UPS power demand PRODUCT HIGHLIGHTS Predecessor PROTECT B.3000 3000 VA / 2100 W PROTECT B.3000 PRO 3000 VA / 2700 W 6

MORE EASY TO OPERATE - Status display - Separate bargraphs for load level & battery capacity PRODUCT HIGHLIGHTS - Measurements ( Input / output data, load level [%], autonomy time [min.], temperature [ o C]) - Settings by panel ( output voltage, performance of output segment ) - Alarm messages, e.g. overload, short circuit, low batt, battery fault - Audible alarm can be disabled 7

INFORMATION ON LCD DISPLAY PRODUCT HIGHLIGHTS 8

DISPLAY MESSAGES ( SAMPLES ) PRODUCT INFO Normal operation 66% load / battery fully charged UPS switched to battery operation 6min. remaining 5min. autonomy time autonomy time battery voltage 43.9V 9

all models with integrated battery system MODEL VARIETY 750 VA 1000 VA 1000 VA plus battery extension PRODUCT INFO 1400 VA 1800 VA 1800 VA plus battery extension 2300 VA 3000 VA 3000 VA plus battery extension 10

REAR VIEW PROTECT B.750PRO / B.1400PRO PROTECT B.2300 PRO / PROTECT B.3000 PRO (B.3000PRO with connector for ext.battery pack) PRODUCT HIGHLIGHTS B.1000PRO / B.1800PRO / B.3000PRO with connector for battery extension Fig. shows B.1800 PRO with B.1800 BP PRO - 2 outlet segments (1segment programmable) - Overvoltage protection for data interface, phone, fax, modem and network (RJ11&RJ45) - Speed controlled fans ( 45dB(A) at ECO mode & max. 70% load ) - Emergency Power Off contact - Dual- monitoring communication interface (RS232 or USB in parallel to mini- slot ) 11

BATTERY PACKS / -EXTENSION (BP) Height: 2U - Strong 2 stage battery charger for quick battery recharge - Autom. battery check (weekly) PRODUCT HIGHLIGHTS Autonomy time (pf = 0.9 lag.) Data at full load / half load [min.] B.750 PRO B.1000 PRO B.1400 PRO B.1800 PRO B.2300 PRO B.3000 PRO UPS with integrated battery system UPS with integrated battery system plus additional battery extension 3.5 / 10 3.5 / 11 5 / 13 4.5 / 13.5 3.5 / 13.5 4 / 11 - - - 14 / 36 - - - 17.5 / 43.5 - - - 15 / 36 Height: 2x2U - Automatic detection of possibly connected battery pack extension - High- grade battery system (proprietary brand) - All models equipped with temperature compensated float charging voltage 12

AUTONOMY TIME DATA AT PART LOAD PROTECT B.PRO at pf = 0.9 lag. and at... < < < < < < A u t o n o m y t i m e a t > > > > > > ~ 10% load ~ 25% load ~ 50% load ~ 75% load 100% load PRODUCT INFO PROTECT B.750 PRO ( 750 VA ) = 70 W = 170 W = 340 W = 500 W = 675 W with integrated battery system 77 min. 25 min. 10 min. 6.5 min. 3.5 min. PROTECT B.1000 PRO ( 1000 VA ) with integrated battery system = 90 W 68 min. = 225 W 23 min. = 450 W 11 min. = 675 W 6.5 min. = 900 W 3.5 min. with 1 x PROTECT B.1000 BP PRO 207 min. 72 min. 36 min. 22 min. 14 min. PROTECT B.1400 PRO ( 1400 VA ) with integrated battery system = 125 W 90 min. = 315 W 33 min. = 630 W 13 min. = 945 W 8.5 min. = 1260 W 5 min. PROTECT B.1800 PRO ( 1800 VA ) with integrated battery system = 160 W 85 min. = 405 W 32 min. = 810 W 13.5 min. = 1215 W 8 min. = 1620 W 4.5 min. with 1 x PROTECT B.1800 BP PRO 258 min. 99 min. 43.5 min. 27.5 min. 17.5 min. PROTECT B.2300 PRO ( 2300 VA ) = 210 W = 520 W = 1035 W = 1550 W = 2070 W with integrated battery system 100 min. 32 min. 13.5 min. 6.5 min. 3.5 min. PROTECT B.3000 PRO ( 3000 VA ) = 270 W = 675 W = 1350 W = 2025 W = 2700 W with integrated battery system 80 min. 26 min. 11 min. 6.5 min. 4 min. with 1 x PROTECT B.3000 BP PRO 243 min. 81 min. 36 min. 23 min. 15 min. 13

AUTONOMY TIME DATA AT PART LOAD PROTECT B.PRO at pf = 0.7 lag. and at... < < < < < < A u t o n o m y t i m e a t > > > > > > ~ 10% load ~ 25% load ~ 50% load ~ 75% load 100% load PRODUCT INFO PROTECT B.750 PRO ( 750 VA ) = 50 W = 130 W = 260 W = 390 W = 525 W with integrated battery system 101 min. 34 min. 15 min. 9 min. 5.5 min. PROTECT B.1000 PRO ( 1000 VA ) = 70 W = 175 W = 350 W = 525 W = 700 W with integrated battery system 90 min. 30 min. 15 min. 9.5 min. 5.5 min. with 1 x PROTECT B.1000 BP PRO 273 min. 93 min. 48 min. 31.5 min. 19.5 min. PROTECT B.1400 PRO ( 1400 VA ) = 100 W = 245 W = 490 W = 735 W = 980 W with integrated battery system 120 min. 45 min. 19 min. 12 min. 7 min. PROTECT B.1800 PRO ( 1800 VA ) = 125 W = 315 W = 630 W = 945 W = 1260 W with integrated battery system 115 min. 43 min. 20 min. 12 min. 7 min. with 1 x PROTECT B.1800 BP PRO 348 min. 132 min. 63 min. 39 min. 23 min. PROTECT B.2300 PRO ( 2300 VA ) = 160 W = 400 W = 805 W = 1205 W = 1610 W with integrated battery system 130 min. 45 min. 20 min. 10 min. 6 min. PROTECT B.3000 PRO ( 3000 VA ) = 210 W = 525 W = 1050 W = 1575 W = 2100 W with integrated battery system 110 min. 35 min. 15 min. 10 min. 6 min. with 1 x PROTECT B.3000 BP PRO 333 min. 108 min. 48 min. 33 min. 21 min. 14

SOFTWARE PACKAGE COMPUWATCH INCLUDED for Windows / Linux / Mac OS X / Unix a.o. included in the delivery as standard PRODUCT INFO 15

BATTERY CONNECTION Front panel incl. LCD display remains to the UPS unit ( hot-swappable process ) Easy handling, e.g. flip-over front cover PRODUCT HIGHLIGHTS Front cover opening without tool necessity Connection for internal battery with fixed polarity ( + / ) During the whole process the UPS can stay mounted in the network rack! You don t have to disassemble anything! 16

EASY BATTERY REPLACEMENT E.G. INTEGRATED SLIDE-IN UPS BATTERY PRODUCT HIGHLIGHTS 1 3 2 4 17

SHIPMENT PROTECT B.750 PRO UP TO PROTECT B.1800 PRO PRODUCT INFO PROTECT B.1000 PRO 1 x PROTECT B.1000 PRO 2 x rack mounting brackets 2 x device stands 2 x load cords 18

SHIPMENT PROTECT B.2300 PRO AND PROTECT B.3000 PRO PRODUCT INFO PROTECT B.3000 PRO 1 x PROTECT B.3000 PRO 2 x rack mounting brackets 2 x device stands 3 x load cords 2x10A / 1x16A 19

COMPETITIVENESS SUM UP - More active power ( pf of 0.9 lagging, suitable for all kind of critical loads ) - Compact size (only 2U for all models), modern solid look ( integrated battery, metal case, Rack- / Tower convertible ) - Easiest intuitive operation ( rotatable LCD display with UPS status and measurements, autonomy time in minutes, programmable outlet segment ) - Strong battery charger with intelligent battery management ( two stage technology incl. temperature compensation) - Battery pack extensions for 1000VA / 1800VA / 3000VA Easy hot-swappable battery replacement for all models ( flip-over panel - UPS can stay in the rack completely ) - Highest communication flexibility ( dual-monitoring interface) CONCLUSION 20