Level Sensor with G1/2" Thread Hygienic

Similar documents
Level Sensor with M12 Thread Hygienic

Conductive Multilevel Sensor

Continuous level sensor NSK

Continuous level sensor NSK

Continuous Level Sensor NSL-F

Ultrasonic flow switch FWS-141, FWA-141

Continuous level sensor NSL-F-00, -01, -02

Hygienic, Elastomer- and Gap Free Process Connections

Compact Pressure Transmitter DAN-HH

Digital Pressure Gauge / Pressure Switch

Mini Pressure Transmitter HA7

Modular Pharma Pressure Transmitter MPP

Temperature Sensor without thread

Magnetic-Inductive Flow Meter FMI

Magnetic-Inductive flow Meter fmi

Magnetic-Inductive Flow Meter FMQ

Turbine flowmeter HM-E / HMP-E

Modular Pressure Transmitter PF

Operating instructions Binary level sensor LMT /00 06/2011

OPTISWITCH 6500 C Technical Datasheet

SITRANS P measuring instruments for pressure

Compact System NRGS 11-2 NRGS Original Installation Instructions English

JUMO tecline CR-4P Conductive 4-Electrode Conductivity Sensor

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

Flow measurement FlexFlow PF20H Hygienic flow sensor

OPTISWITCH 6500 C Technical Datasheet

Insertion magnetic inductive flowmeter

Turbine flowmeter HM-E / HMP-E

Temperature sensor TE2

Level Limit Switch liquiphant FTL 360 / FTL 361

OPTIFLUX 6000 Technical Datasheet

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Pressure measurement PP20H Fully welded hygienic pressure sensor with flush membrane

OPTISWITCH 4000/5000. Vibration level switches for liquids

CombiTemp Temperature Measuring System

Rod probe 11375Z. Technical Information. Conductive level limit detection Partially insulated rod probe for use in conductive liquids

Thermowell For sanitary applications Model TW22

Operating Instructions. VEGASWING 61, 63 with oscillator SW E60N (EX)

Differential Pressure Sensors

JUMO MIDAS S05 Pressure transmitter Type

Conductivity Measuring Sensor InduMax H CLS 52

Level Probes multicap T DC 12 TE multicap T DC 11/16/21/26 TEN/TES

Pressure Transmitters for Sanitary Applications Model SA-11

Operating instructions Binary level sensor. LI214x /00 04/2016

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

Magnetic Inductive Flowmeter EP / UMF2 (B)

AGW Life Sciences Series Guided Wave Radar

Magnetic Inductive Flow

Level sensor Magnetostrictive, high-resolution measurement principle Model FLM-H, for sanitary applications

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

HBSO1 Oil switch. Instruction manual. For detecting oil in refrigeration systems WE INCREASE UPTIME AND EFFICIENCY IN THE REFRIGERATION INDUSTRY

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

Paddle-wheel flow controller for On/Off control

BUTTERFLY VALVES + NA ELECTRIC ACTUATOR

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

ETP80. Electronic Transmitter for Pressure, Differential Pressure and Level

Resistance thermometer For sanitary applications Model TR22-A, exchangeable sensor

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Pressure Transmitters

Level Probes multicap T DC 12 TA multicap T DC 11/16/21/26 TAN/TAS

Electromagnetic Flow Monitor magphant

Modular resistance thermometer - Quicktemp TP60/TW39...T500 -

Thermal flow sensor TFS-35

Operating Instructions OPTISWITCH 4000 C with transistor output

Thermowell For sanitary applications Model TW61, for orbital welding

Level Measurement Point level measurement - RF Capacitance switches

Digital ph transmitter

Pressure transmitter UNIVERSAL CA

DIAMOND POINT VIBRATING PROBES

Operating Instructions 07/2013

Differential Pressure Sensors

Level Switch LFFS. distributed by Data sheet

Level Probes multicap DC 11/16/21/26 EN multicap DC 11/16/21/26 ES

Vibrating Level Switch TF 511, TF 611, TF 633

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

Digital ph transmitter

Pressure transmitter COMPACT ECOnomic

Operating Instructions OPTISWITCH 5100 C, 5150 C with transistor output

Capacitive level sensors CLS 23

Operating Instructions April 2008 SITRANS LVL100

Capacitive Sensors. Series 80 - PNP

Resistance Temperature Sensors for Hygienic and Sanitary Applications

Level limit switch Series RF 3000 Selection list

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

Diaphragm Valve, Metal

Diaphragm seal with sterile connection For sanitary applications Models , , and , threaded connection

SITRANS T measuring instruments for temperature

Level Limit Switch liquiphant FTL 365 / FTL 366

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

METAL DETECTOR AND REJECTION SYSTEM FOR PIPELINE APPLICATIONS

Thermowell For sanitary applications Model TW61, for orbital welding

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Thermowell For sanitary applications Model TW61, for orbital welding

Paddle-wheel flow controller with optical principle for On/Off control

Transcription:

SENSORS FOR FOOD AND BIOPHARMA. Product Information NVS-141, -143, -146, -161, -163, -166, -181, -183, -186 FOOD Level Sensor with Thread Hygienic Application/intended use Limit detection of aqueous and conductive media in vessels and pipes with minimum conductivity. The conductivity depends on the evaluation device: 1 µs/cm when using external evaluation units, e.g. VNV series or ZNV-Z, and 10 µs/cm when using the internal evaluation unit MNV-1C or MNV-M. Application examples Limit detection of fluids in vessels (where the sensor is built in from the side) or pipes Full alarm in vessels and tanks where the sensor is built in from the top Empty alarm in vessels and tanks where the sensor is built in from the bottom Product monitoring in pipes Pump/dry-running protection Level control in tanks Overfill protection in dosing systems Hygienic design/process connection Using the Negele EMZ-132 weld-in sleeve or the EHG-.../1/2" weld-in system ensures a hygienic and easily sterilizable installation situation with optimal flow properties. Elastomer-free sealing system provides a connection without gaps and crevices (see CLEANadapt product information) CIP/SIP cleaning up to 143 C/120 minutes max. All parts that have direct contact with the product comply with FDA regulations Sensor made entirely of stainless steel and PEEK, coating made of PFA Process connections, see CLEANadapt product information, e.g.: Tri-Clamp, dairy flange (DIN 11851), Varivent... Complies with 3-A Sanitary Standard 74-06 Special features/advantages Defined position of the cable entry Available with or without an integrated level transmitter Different electrical connections available Rods may be shortened and twisted as needed Miniature edition, installation in pipes beginning at DN25 possible Fully molded to avoid condensation Options/accessories High-temperature version available (with 100-mm spacer; for use in processes with constant temperatures of up to 140 C) Fixed cable also available in other cable lengths Selection of the right sensor type Coating For foamy, adhesive (e.g. yoghurt) and/or wetting media (e.g. alkaline solutions), we suggest using a sensor with a coated rod. Sensors with non-coated rods are only suitable for aqueous, non-adhesive and non-wetting media. Temperature If a sensor with an integrated level transmitter MNV is needed, we suggest using the high-temperature version with a spacer if the medium temperature exceeds 60 C (option H). Authorizations NVS-146 NVS-141 NVS-161 TYPE March 2006 74-06

FOOD Specification 2 Specification of level sensor Process connection Material Surface quality Weight crevice-free torque thread size connecting head rod insulating part coating Rods NVS-141; -161; -181 Operating pressure Temperature ranges* Electrical connection Protection class NVS-143; -146; -163; -166; -183; -186 process NVS-14x process NVS-16x, NVS-18x cleaning ambient cable gland plug connection fixed cable 2.5 m - with level transmitter - without level transmitter with M12 plug connection with cable connection CLEANadapt build-in system, e.g. EMK-132 or EHG-.../1/2" 5...10 Nm 1.4301 1.4404 PEEK (FDA approval number 21CFR177.2414) PFA (FDA approval number 21CFR177.2440, 21CFR177.1550) R a 0.8 µm (wetted parts) approx. 500 g ø 4 mm, length: 200; 500; 850; 1000; 1500; 2000 mm (may be shortened to the requested length) ø 8 mm, length: 18 mm max. 10 bar 0...140 C 0...100 C 143 C/120 min -10...+60 C M16x1.5 (PG) M12 plug, 1.4305 PVC 4 x 0.25 mm² silicone 2 x 0.5 mm² IP 69 K IP 67 *) When the MNV level module is integrated, please note the temperatures specified below in the technical data of the level transmitter. Specification of MNV level transmitter (attention: differs from the basic unit) Temperature ranges operation storage Humidity without condensation 0...95% r. H. Power supply -10...+60 C (with NVS standard equipment) -10...+140 C (with NVS high-temperature version) -20...+60 C 18...36 V DC Electrode E1 measuring voltage 1.5...2 VAC/300 Hz no DC signal Selectable sensitivity Output MNV-1C MNV-M Delay fixed 0.5 s 0.1 kω; 1 kω; 10 kω; 100 kω (via jumper) 0.2 kω; 2 kω; 20 kω (via control input voltage (Tri-State-Logic)) PNP (active 50 ma, short-circuit-proof) Switching function min/max selectable MNV-1C MNV-M via jumpers polarization of power supply

3 Dimensional Drawings FOOD NVS-141/M NVS-143/... NVS-146/... NVS-143/.../H NVS-146/.../H Ø57 Ø57 Ø57 4 18,5 96,5 188,5 92 Advice for NVS-143/.../H Tighten the sensor only at the lower, marked in yellow spanner flat (BE = 22 mm)! NVS-163 NVS-166 NVS-163/M NVS-166/M NVS-181 NVS-183/M 81 60,5 9 77 97,5 9 2,5 m 4 18,5 2,5 m 96,5 Ø8 Ø8

FOOD Electrical Connection Configuration 4 Electrical connection without level transmitter Electrical connection with MNV-1C, MNV-M transmitter With terminals With clamps (with level transmitter MNV-1C) EO M rod (sensor) GND EO M 1 GND 2 rod (sensor) 1 2 3 4 5 3 active output 4 +power supply 5 -power supply With M12 plug Configuration of the M12 plug 1 (brown) not connected 2 3 (blue) GND 4 (black) sensor With M12 plug (with level transmitter MNV-M) Configuration of the M12 plug (full alarm) 1 (brown) +power supply 2 (white) control input sensitivity 3 (blue) -power supply 4 (black) active output With fixed cable With PVC/silicone cable brown rod blue GND With Teflon cable (PTFE) red rod white GND With fixed cable (with level transmitter MNV-M) With PVC cable (full alarm) white yellow brown green +power supply control input sensitivity -power supply active output Notice: silicone and/or Teflon cables (PTFE) are not available in this version. Instructions on the electrical connection with level transmitters MNV-1C, MNV-M The sensitivity and the switching behavior of sensors with level transmitters may be configured using an electrical connection or a jumper. Please also take note of the figures on the next page. Setting up the MNV-1C, MNV-M level transmitters Connect the supply voltage. Select the switching function (see Configuration of the level transmitter ). Select the minimum sensitivity (see Configuration of the level transmitter ). Wet the sensor with the least conductive medium. If the output switches, the selected sensitivity may be retained and calibration is finished. If the output does not switch, please continue as follows. Increase the sensitivity until the output switches. Once this happens, calibration is finished.

5 Configuration of the MNV-1C, MNV-M Level Transmitters FOOD Switching state explanation Configuration of the MNV-1C level transmitter Full indicator: Empty indicator: The output is active when immersed The output is active when not immersed 3 function 4 full sensitivity 0.1 kω sensitivity 1 kω Level transmitter MNV-1C 1: LED sensor (lights up when the sensor is immersed, independent of the switching function) 2: Terminal block 3: Full/empty jumper 4: Sensitivity jumper 1 4 2 3 function empty Standard setting on delivery 3: full 4: 10 kω sensitivity 10 kω sensitivity 100 kω Configuration of the MNV-M level transmitter with NVS-161/M; NVS-163/M; NVS-166/M Sensitivity full alarm empty alarm 0.2 kω 2 kω 20 kω Configuration of the MNV level transmitter with NVS-181/M; NVS-183/M;NVS-186/M Sensitivity full alarm empty alarm 0.2 kω 2 kω 20 kω

FOOD Installation Notices Process Connections 6 General installation If necessary, cut the rods to the required lengths. In doing so, ensure that the compound between the rod and the thread connector is not strained excessively. If using coated rods, do not damage the insulation of the rod part that remains on the sensor. Strip 5 mm of insulation off the tip of insulated rods (the length depends on the conductivity of the medium). Screw the sensor into the sleeve and connect as shown in the wiring diagrams. Do not damage the coating when you mount the sensor in the sleeve. Mounting instructions Do not exceed the maximum torque when you screw in the sensor. To guarantee reliable operation of the measuring point, make sure you have a good electrical connection between the process connection thread of the sensor and the pipe or vessel wall. Do not use any kind of sealing tape, such as Teflon tape. Also follow the instructions in the CLEANadapt product information if necessary. If the stub sensor is used in pipes, ensure that the rod emerges from the liquid when the medium is drained. We suggest installing the sensor in vertical pipes. Tank and pipe walls must be made of metal. For mounting and removing the sensor, please use the wrench flats only. Do not use the connecting head. Conditions for a measuring point according to 3-A Sanitary Standard 74-06 The sensors NVS-141, -143, -146, -161, -163, -166, -181, -183, -186 comply with the 3-A standard. The sensors are designed for CIP/SIP cleaning up to a maximum temperature of 143 C for 120 minutes. Only approved in combination with the CLEANadapt build-in system (EMZ, EMK, EHG with a pipe diameter > DN25, ISO 20 and 1", AMC and AMV adapters) When using the EMZ and EMK weld-in sleeves, the weld must comply with the requirements of the current 3-A Sanitary Standard. Mounting position: The mounting position, self-draining properties and the position of the leakage hole must be in accordance with the current 3-A Sanitary Standard. Information on CLEANadapt process connections Please find the complete overview of all adapters available as well as the respective technical data in the product information on CLEANadapt process adapters. Selection of possible process connections Process connection Build-in system EHG (DIN 11850 series 2) Weld-in sleeve Weld-in ball Collar sleeve APV-Inline

7 Notices Accessories FOOD Cleaning/Maintenance When using a pressure washer, do not point the nozzle directly at the electrical connections. Reshipment Sensors and process connection must be clean and must not be contaminated with hazardous media and/or heatconductive paste. Note the cleaning information! To avoid damage of the equipment, use suitable transport packaging only. Transport/Storage No outdoor storage Store in an area that is dry and dust-free Do not expose to corrosive media Protect against solar radiation Avoid mechanical shock and vibration Storage temperature 0...40 C Relative humidity max. 80% Standards and guidelines Compliance with the applicable regulations and directives is mandatory. Notice on conformity Applicable guidelines: Electromagnetic Compatibility Directive 2004/108/EC The CE label confirms compliance of this product with the applicable EC directives. You have to guarantee the compliance of all guidelines applicable for the entire equipement. Disposal This instrument is not subject to the WEEE directive 2002/96/EC and the respective national laws. Give the instrument directly to a specialized recycling company and do not use the municipal collecting points. Information on external evaluation devices Please find the complete overview of all external evaluation devices available as well as the respective technical data in the product information on evaluation electronics for conductive limit switches. Selection of possible external evaluation electronics with relay or active output Type VNV-E VND-D ZNV-Z VNV-V 1 x level control 1 x level control 1 x level detection 2 x level detection 4 x level detection

FOOD Product Information NVS-141, -143, -146, -161, -163, -166, -181, -183, -186 8 Order code NVS-14 NVS-16 NVS-18 (connecting head diameter 55 mm with cable gland M16x1.5) (connecting head diameter 18 mm with M12 plug) (connecting head diameter 18 mm with fixed cable 2.5 m; other cable lengths: see at accessories) Rod 1/00 3/200 3/200-8 6/200 6/200-8 3/500 3/500-8 6/500 6/500-8 3/850 3/850-8 6/850 6/850-8 3/1000 3/1000-8 6/1000 6/1000-8 3/1500 6/1500 3/2000 6/2000 3/[mm] 6/[mm] (without coating, stub sensor = 4 mm) (without coating 200 mm, diameter 4 mm) (without coating 200 mm, diameter 8 mm) (coated 200 mm, diameter 4 mm) (coated 200 mm, diameter 8 mm) (without coating 500 mm, diameter 4 mm) (without coating 500 mm, diameter 8 mm) (coated 500 mm, diameter 4 mm) (coated 500 mm, diameter 8 mm) (without coating 850 mm, diameter 4 mm) (without coating 850 mm, diameter 8 mm) (coated 850 mm, diameter 4 mm) (coated 850 mm, diameter 8 mm) (without coating 1000 mm, diameter 4 mm) (without coating 1000 mm, diameter 8 mm) (coated 1000 mm, diameter 4 mm) (coated 1000 mm, diameter 8 mm) (without coating 1500 mm, diameter 4 mm) (coated 1500 mm, diameter 8 mm) (without coating 2000 mm, diameter 4 mm) (coated 2000 mm, diameter 8 mm) special length without coating (length in mm) special length coated (length in mm) Evaluation unit X (without) M (integrated in connecting head; type-specific with MNV-1C or MNV-M) High-temperature version X (standard, only for sensors without evaluation unit and type-specific process temperatures (see technical data)) H (with spacer: recommended for evaluation unit and process temperatures > 60 C) ATTENTION: Please note the specifications regarding process temperature as given in the technical data. Wire-break monitoring (only possible with an external evaluation unit VNV-SD or VNV-W) X (without) D (with wire-break resistor) Electrical connection (not selectable at NVS-16x and NVS-18x) X (cable gland M16x1,5) M12 (M12 plug 1.4305) NVS-14 3/200 / M / H / X / M12 50034 / 4.0 / 2015-01-17 / MU / EU NEGE MESSTECHNIK GMBH Raiffeisenweg 7 87743 Egg an der Guenz Phone +49 (0) 83 33. 92 04-0 Fax +49 (0) 83 33. 92 04-49 sales@anderson-negele.com Tech. Support: support@anderson-negele.com Phone +49 (0) 83 33. 92 04-720