Energy Power Plants Trainer AEL-EPP

Similar documents
DC Brushless Motor Application AEL-DCBRA

Application of AC Three-Phase Induction Motor of Squirrel Cage AEL-ACINA

Application of AC Dahlander Three-Phase Induction Motor AEL-ACDHA

Application of AC Three-Phase Induction Motor of Wound Rotor AEL-ACWRA

Transparent and Functional Motors Application AEL-FTM

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device

Motor-Generator and Transformer Construction Application AEL-MGTC

Wind Energy Unit EEE. Engineering and Technical Teaching Equipment PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Electronic console

MGI. Gyroscope PROCESS DIAGRAM AND UNIT ELEMENTS ALLOCATION. Engineering and Technical Teaching Equipment

Basic Unit of Mechanical Drive Systems MDSU. Engineering and Technical Teaching Equipment INTRODUCTION GENERAL DESCRIPTION

Biodiesel Process Unit EBDB

Assembly and Maintenance of Pumps AMP

Power Systems and Smart Grid Technology Lab

Photovoltaic Solar Energy Modular Trainers

Photovoltaic Solar Energy Modular Trainers

AEL-4. Advanced Electrical Laboratories (AEL-LABS): Electromechanical Constructions Lab. Engineering and Technical Teaching Equipment

TECNEL. Computer Controlled Teaching Unit for the Study of Power Electronics. (Converters:DC/AC+AC/DC+DC/DC+AC/AC)

Electrical Machines Lab

Final User Smart Grid Trainer AEL-FUSG

Screenshot of the computer data acquisition and calculations software INTRODUCTION

Hydraulic and Electro-Hydraulic Application AE-HD

Photovoltaic Solar Energy Unit EESFB

Pneumatic and Electro-Pneumatic Application AE-NS INTRODUCTION

EDIBON SCADA System and PID Control included. 2 Control Interface Box. 1 TIUS. Base Service Unit. Cables and Accessories Manuals. TIPL.

RENEWABLE ENERGY TRAINER

Computer Controlled Heat Exchangers Training System, with SCADA and PID Control TICC

Fluid Friction in Pipes, with Hydraulics Bench (FME00) AFT

BAIJI OIL TRAINING INSTITUTE ISO-9001:2008 DATE :1/4/2014 LABORATORY FOR THE ELECTRICAL SYSTEMS AND CONTROL OF OIL DRILLING RIGS $

UNC-Charlotte's Power Engineering Teaching lab

Solar power training packages From basic to industrial concepts

SINAMICS GM150 IGCT version

ELECTRIC MACHINES EUROLAB 0.3 kw

Table of Contents. Lucas Nülle GmbH Page 1/7

Hybrid and Electric Vehicles

Regenerative Utility Simulator for Grid-Tied Inverters

Electrical Power Systems 2014/15

Hydrogen Fuel Cell Training System

Hydrogen Fuel Cell Training System ( )

DER Commissioning Guidelines Community Scale PV Generation Interconnected Using Xcel Energy s Minnesota Section 10 Tariff Version 1.

Renewable Energy Grid Integration and Distributed Generation Specialization Syllabus

Advanced Active And Reactive Power Control For Mini Grids

Brake Test On Three Phase Induction Motor Lab Manual

renewable energy and energy efficiency

Integrated Laboratory for Electrical Machines LIMEL

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

EE042: Practical Power System Protection for Engineers & Technicians

Power Systems Trainer

9.1.4 Troubleshooting of Faults in LCD Screen

Electric Power Technology Training Systems

Power Conversion System The Best Technology for your photovoltaic and storage system

825-P Modular Protection System for motors Specification Guide

MGE TM Galaxy TM 7000 GFC

ACSEP - Applications and Control of Power Electronic Systems

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Unit Protection System for Pumped-Storage Power Stations

Definitions. Scope. Customer Generation Interconnection Requirements

WORK BENCHES FOR ELECTRIC INSTALLATIONS. index

SIRFN Capability Summary European Distributed Energy Resources Laboratories (DERlab) e. V.

INTRODUCTION. Technological limitations on metering no longer force peak power prices to be averaged out and passed on to all consumers equally.

Energy Security Electrical Islanding Approach and Assessment Tools. Dr. Bill Kramer Senior Research Engineer Distributed Energy Systems Integration

Sunny Tripower. Can do everything that we can

renewable energy and energy efficiency

TRAINING SYSTEMS FOR ELECTRICAL POWER ENGINEERING. The Complete Power Supply Network with Renewable Energies. 6 th Edition

Mains. Great performances. Attractive coloured display. PLC functions inbuilt. Several I/O with possibility of expansion modules

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

AEL-3. ELECTRICAL MACHINES LAB AEL-2. HOME AUTOMATION SYSTEMS LAB

HIGH-VOLTAGE BATTERIES DIAGNOSTICS & MAINTENANCE TRAINER

HYDROGEN FUEL CELL TRAINING SYSTEM

T-Line Generator Control, Protection and Monitoring

Created by: Energy: Electricity. Frances Carlo. EDTC Tools for Visualizing Information F I N A L P R O J E C T. Fall 2017

Power Conditioning of Microgrids and Co-Generation Systems

E.V.READY Specification for Installer Training Content

GRUNDFOS DATA BOOKLET. Grundfos RSI. Renewable solar inverter for pump control kw

4-Day Power System Analysis, Coordination, System Studies

A Electric Power / Controls SMART GRID TECHNOLOGIES 0.2 kw

KONČAR Group. Research and Development

Current Automation Catalogue

Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

: ANIMATION OF A POWER SYSTEM USING POWERWORLD SIMULATOR

Using MATLAB/ Simulink in the designing of Undergraduate Electric Machinery Courses

Electrical Theory. Generator Theory. PJM State & Member Training Dept. PJM /22/2018

RVS-DN Digital Reduced Voltage Motor Starter

MKN-DSP SERIES - THREE PHASE

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

D Series: UPS UPTO - 300KVA - Three / Three Phase

ES09 ELECTRICAL MACHINES TECHNICAL SPECIFICATIONS

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

REQUIREMENTS FOR PARALLEL OPERATION FOR CUSTOMERS WITH GENERATION NOT EXCEEDING 50 kw

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Static frequency converter couples US paper mill s 25-Hz and 60-Hz electricity grids

A Electric Power / Controls ELECTRIC POWER TECHNOLOGY 0.2 kw

Basics of Paralleling

Power Electronics and Drives (PED)

SQA Advanced Unit specification: general information

DYNA4 Open Simulation Framework with Flexible Support for Your Work Processes and Modular Simulation Model Library

Guideline for Using IEEE 1547 for Solar PV Interconnection Page 1

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

New range of reclosing systems

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Transcription:

Engineering and Technical Teaching Equipment Energy Power Plants Trainer AEL-EPP Key features: Advanced Real-Time PSV-SCADA. Open Control + Multicontrol + Real-Time Control. 1 Unit: AEL-EPP. Energy Power Plants Trainer Specialized EDIBON Control Software based on LabVIEW. Projector and/or electronic whiteboard compatibility allows the unit to be explained and demonstrated to an entire class at one time. Capable of doing applied research, real industrial simulation, training courses, etc. Remote operation and control by the user and remote control for EDIBON technical support, are always included. Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic & Software). Designed and manufactured under several quality standards. Optional ICAI software to create, edit and carry out practical exercises, tests, exams, calculations, etc. Apart from monitoring user's knowwledge and progress reached. This unit has been designed for future expansion and integration. A common expansion is the EDIBON Scada-Net (ESN) System which enables multiple students to simultaneously operate many units in a network. For more information about Key Features, click here http:///products/catalogues/en/keyfeatures.pdf http://www.youtube.com/embed/cegmr00obpw ISO 9001: Quality Management (for Design, Manufacturing, Commercialization and After-sales service) European Union Certificate (total safety) 1 Certificates ISO 14001 and ECO- Management and Audit Scheme (environmental management) Certificate and Worlddidac Member

GENERAL DESCRIPTION Nowadays power generation from different energy sources is essential to get a reliable and robust electrical power system. Hydroelectric, thermal, nuclear and ocean power plants play an important role in the energy mix in a country. Depending on the moment of the day, the climatology, the tides and the total power demanded at any time, the energy production may come from different energy sources. For this reason it is very interesting and important to understand how work these type of energy sources. The Energy Power Plants Trainer AEL-EPP is a modular trainer designed to demonstrate the working principles of different power plants along with automatic governor control so that the students can understand the whole mechanism of them. Hydroelectric power plant, Thermal Power Plant, Nuclear power Plant and Ocean Energy Power Plant are studied in depth through this complete trainer. Optionally, Power Systems SCADA Viewer PSV-SCADA can be included in order to carry out remote control operations related to the mentioned power plants such as synchronization operations, active power generation, reactive power control, setting of generator controller, simulate different water flows, thermal and ocean (tides) situations under different conditions and many other possibilities which will give the students large knowledge about this issues. The AEL-EPP includes different modules which allow represent similar situations produced in real power systems, for instance the servomotor module. This module is connected to the PSV-SCADA and it receives different commands according to mathematical models of the power plant previously loaded in the software. On this way, if the user is working, for example, with the hydroelectric power plant, he can change different conditions such as water potential energy (initial height) and to observe how the servomotor speed changes, the active power is increased, etc. Other important module is the automatic voltage and frequency controller. This module allows the user understand how work a real industrial controller used in large power stations. This controller ensures that frequency and voltage are constant for any external or internal condition. Besides, it protects the synchronous generator and governor against over currents, over/under voltages, over/under frequencies, reverse powers, over and under speeds, etc. The AEL-EPP includes the following modules: N-ALI01. Industrial Main Power Supply. N-AVR/P. Automatic Voltage Regulator. N-ASY/B. Basic Synchronization Module. N-SERV1K. 1 kw Servomotor Module. N-EALD. Network Analyzer Unit with Computer Data Acquisition. N-ERP-PGC-02. Automatic Voltage and Frequency Controller. Generator: EMT6B/1K. 1KVA three-phase Synchronous generator. Optional SCADA software: PSV-SCADA. Power Systems SCADA Viewer, required as well for working with the following optional simulation software: - PSV-NPPS-SOF. Nuclear Power Plants Simulator. - PSV-HPPS-SOF. Hydroelectric Power Plants Simulator. - PSV-OPPS-SOF. Ocean Energy Power Plants Simulator. - PSV-CCPP-SOF. Combined Cycle Power Plants Simulator. - PSV-DFPP-SOF. Diesel Fuel Power Plant Simulator. - PSV-FFPP-SOF. Fosil Fuel Power Plant Simulator. - PSV-GSPP-SOF. Gas Power Plants Simulator. - PSV-WPPP-SOF. Wind Powered Power Plant Simulator. - PSV-PPP-SOF. Photovoltaic Power Plant Simulator. - PSV-BPP-SOF. Biomass Power Plant Simulator. - PSV-FCPP-SOF. Fuel Cells Power Plant Simulator. - PSV-GPP-SOF. Geothermal Power Plants Simulator. - PSV-HSPP-SOF. Heliothermic Solar Power Plant Simulator. - PSV-STPP-SOF. Steam Turbine Power Plant Simulator. In addition, Edibon provides optional software (AEL-EPP/ICAI) to reinforce knowledge about this field. This software is formed by: ECM-SOF. EDIBON Classroom Manager (Instructor Software). ESL-SOF. EDIBON Student Labsoft (Student Software). The application AEL-EPP can be mounted on rack (option A) or on rail (option B): Option A: This application needs the following racks: N-RACK-M. N-RACK-B (2 units). Optionally the AEL-WBR. Electrical Workbench (Rack) can be supplied to place the rack/s. Option B: This application can be mounted on rail. Optionally the AEL-WBC. Electrical Workbench (Rail) can be supplied to mount the modules. Optionally this Computer Controlled Unit is supplied with the EDIBON Computer Control System (PSV-SCADA), and includes: The unit itself + Computer Control, Data Acquisition and Data Management Software Packages, for controlling the process and all parameters involved in the process. 2

Complete Technical Specifications (for main items) With this unit there are several options and possibilities: - Main items: 1, 3 and 4. - Optional items: 2, 5, 6 and 7. Let us describe first the main items (1 to 4): 1 AEL-EPP. Unit. The trainer includes the following modules: N-ALI01. Industrial Power Supply. Supply voltage: 400 VAC, 3PH+N+G ON-OFF removable key Output voltage connections: Three-Phase + Neutral: 400 VAC Single-Phase: 230 VAC Three-Phase supply hose with IP44 3PN+E 32A 400V connecting plug. Differential magnetothermal, 4 poles, 25A, 300mA AC 6KA N-AVR/P. Automatic voltage regulator. Generator excitation regulator. Local/remote control switch. Manual/automatic control switch of the excitation in local mode. Excitation current manual control potentiometer. ON-OFF switch. Connection terminals. Communication connector SUB-D of 62 pins. N-ALI01 N-AVR/P N-ASY/B. Basic Synchronization Module. Voltage: 400V. Digital Synchronoscope. Synchronization switch. Double frequenzy meter. Double voltmeter. N-SERV1K. 1 kw Servomotor Module. Dynamic and static four-quadrant operation. Speed and torque displays. Four-quadrant monitor. Thermal monitoring of the machine under test. Testing for the presence of a shaft cover. Connection voltage: 400V. Frequency: 50Hz. Maximum power output: 10kVA. Maximum speed: 4000rpm. Maximum torque 30Nm. Temperature monitoring. N-ASY/B N-SERV1K N-EALD. Network Analyzer Unit with Computer Data Acquisition. ON-OFF switch. Supply voltage: 400 VAC Input terminals: Input connection with the measurement point. Output terminals: Output connection with the measurement point. Digital outputs: Three digital outputs are used for pulses or alarms, or for combining both. RS-485 Communication port. Fuses: 3x10 A Network Analyzer Display. It shows: Active, reactive and apparent power. Active, reactive and apparent energies. Lines and phase currents. Line and phase voltages. Frequencies. Power Factor. 3 N-EALD

Complete Technical Specifications (for main items) N-ERP-PGC-02. Automatic Voltage and Frequency Controller. Generator protection relay module. Single-phase supply voltage: 230 VAC. Island grid/parallel grid control switch. Local/remote control switch. Manual control switches of the relay: 1. SW1, emergency stop. 2. SW2, automatic start of the motor-generator group. 3. SW3, protections reset pushbutton. 4. SW4, generator frequency control activation. 5. SW5, 52G1 synchronization circuit breaker closure manual permission. State light indicators. Alarm light indicators. Synchronization safety key. Emergency stop pushbutton. SUB-D signals connector of 62 pins. ON-OFF switch. Connection terminals. N-ERP-PGC-02 The N-ERP-PGC-02 generator protection relay: Enables to connect up to 16 diesel generators in parallel-island with distribution of active and reactive load and start/stop in function of the load demand. Enables to connect one generator in parallel with the grid Enables different switches control modes, such as opening, closing and synchronization. Includes analogical outputs to control voltage and frequency regulators available in the market. Three-phase measurement of the grid and generator voltage. Three-phase measurement of the generator intensity and power. Single-phase measurement of the grid intensity. Protections: Generator: max/mín-voltage (59/27), max/min-frequency (81O/U), voltage asymmetry, dead bus detection, overload (32), unbalance load (46), reverse power/reduce (32R/F), overcurrent time define curve (50/51), inverse time overcurrent (IEC255), fault ground (50N/51N), phases, breakers fault. Motor: over/sub speed (12). Mains: max/min-voltage (59/27), max/min-frequency (81O/U), vector surge. EMT6B/1K. 1KVA three-phase Synchronous generator. Nominal power: 1 kw. Nominal voltage: 3x 400/230 VAC Y/ Δ. Frequency: 50/60 Hz. Number of poles: 4. RPM: 1500 rpm. Nominal current: 2,1/3,65A Y/ Δ. Nominal excitation current: 4A AC ; 11A DC. All necessary cables to realize the practical exercises are included. The complete unit and optional PSV-SCADA includes as well: EMT6B/1K Advanced Real-Time PSV-SCADA. Open Control + Multicontrol + Real-Time Control. Specialized EDIBON Control Software based on LabVIEW. Projector and/or electronic whiteboard compatibility allows the unit to be explained and demonstrated to an entire class at one time. Capable of doing applied research, real industrial simulation, training courses, etc. Remote operation and control by the user and remote control for EDIBON technical support, are always included. Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic & Software). Designed and manufactured under several quality standards. Optional ICAI software to create, edit and carry out practical exercises, tests, exams, calculations, etc. Apart from monitoring user's knowwledge and progress reached. This unit has been designed for future expansion and integration. A common expansion is the EDIBON Scada-Net (ESN) System which enables multiple students to simultaneously operate many units in a network. 2 PSV-SCADA. Power Systems SCADA Viewer. Compatible with actual Windows operating systems. Graphic and intuitive simulation of the process in screen. Compatible with the industry standards. Registration and visualization of all process variables in an automatic and simultaneous way. Flexible, open and multicontrol software, developed with actual windows graphic systems, acting simultaneously on all process parameters. Management, processing, comparison and storage of data. It allows the registration of the alarms state and the graphic representation in real time. Comparative analysis of the obtained data, after the process and modification of the conditions during the process. Open software, allowing the teacher to modify texts, instructions. Teacher s and student s passwords to facilitate the teacher s control on the student, and allowing the access to different work PSV-SCADA levels. This unit allows the 30 students of the classroom to visualize simultaneously all the results and the manipulation of the unit, during the process, by using a projector or an electronic whiteboard. 3 Cables and Accessories, for normal operation. 4 Manuals: This unit is supplied with 7 manuals: Required Services, Assembly and Installation, Control Software, Starting-up, Safety, Maintenance & Practices Manuals. References 1 to 4 are the main items: AEL-EPP + PSV-SCADA + Cables and Accessories + Manuals are included in the minimum supply for enabling normal and full operation. * 4

Exercises and Practical Possibilities to be done with the Main Items Operations with electrical generator and governor: 1.- Generator island grid operations. 2.- Generator parallel grid operations. 3.- Generator manual voltage regulation operations. 4.- Generator manual frequency regulation operations. 5.- Study of synchronous generator power factor regulation. 6.- Studying of turbine regulation (frequency control) in island mode. 7.- Study of turbine regulation (frequency control) in parallel grid mode. 8.- Study of excitation/voltage regulation in island mode. 9.- Study of excitation/voltage regulation in parallel grid mode. 10.- Analysis of active and reactive power control. 11.- Automatic control of active power. 12.- Automatic control of reactive power. Operations with the frequency and voltage controller working as protection: 13.- Setting of the overcurrent protection of the generator controller. 14.- Setting of the overvoltage and undervoltage protection of the generator controller. 15.- Setting of the reverser power protection of the generator controller. Particular practical exercises related to power plants: Nuclear power plant simulator. 16.- Demostration the working principles and operations of nuclear power plants simulator during varying loads. Hydroelectric power plant simulator. 17.- Demonstration the working principles of mechanism of hydroelectric power plant simulatior. 18.- Manual water flow control. 19.- Automatic water flow control. Ocean energy power plant simulator. 20.- Demonstration of working principles and the way of how energy is stored. Combined Cycle power plant simulator. 21.- Demonstration the working principles of mechanism of combined clycle power plant simulator. 22.- Manual water flow control. 23.- Automatic water flow control. Diesel fuel power plant simulator. 24.- Demonstration the working principles of mechanism of diesel fuel clycle power plant simulator. 25.- Manual fuel flow control. 26.- Automatic fuel flow control. Fossil fuel power plant simulator. 27.- Demonstration the working principles of mechanism of fossil fuel power plant simulator. 28.- Manual fosil control. 29.- Automatic fosil control. Gas power plant simulator. 30.- Demonstration the working principles of mechanism of gas power plant simulator. 31.- Manual gas flow control. 32.- Automatic gas flow control. Wind powered power plant simulator. 33.- Demonstration the working principles of mechanism of wind powered power plant simulator. 34.- Manual wind flow control. 35.- Automatic wind flow control. Photovoltaic power plant simulator. 36.- Demonstration the working principles of mechanism of photovoltaic power plant simulator. 37.- Manual irradiation control. 38.- Automatic irradiation control. Biomass power plant simulator. 39.- Demonstration the working principles of mechanism of biomass power plant simulator. 40.- Manual biomass control. 41.- Automatic biomass control. Fuel cells power plant simulator. 42.- Demonstration the working principles of mechanism of biomass power plant simulator. 43.- Manual hydrogen flow control. 44.- Automatic hydrogen flow control. Geothermal power plant simulator. 45.- Demonstration the working principles of mechanism of biomass power plant simulator. 46.- Manual water flow control. 47.- Automatic water flow control. Heliothermic Solar Power Plant Simulator. 48.- Demonstration the working principles of mechanism of Heliothermic Solar Power Plant Simulator. 49.- Manual solar irradiation control. 50.- Automatic solar irradiation control. Steam Turbine Power Plant Simulator 51.- Demonstration the working principles of mechanism of Steam Turbine Power Plant Simulator 52.- Manual steam flow control. 53.- Automatic steam flow control. Other possibilities to be done with this Unit: 54.- Many students view results simultaneously. To view all results in real time in the classroom by means of a projector or an electronic whiteboard. 55.- The Computer Control System with PSV-SCADA allows a real industrial simulation. 56.- This unit is totally safe as uses mechanical, electrical and electronic, and software safety devices. 57.- This unit can be used for doing applied research. 58.- This unit can be used for giving training courses to Industries even to other Technical Education Institutions. - Several other exercises can be done and designed by the user. REQUIRED SERVICES - Electrical supply: three-phase, 380V./50 Hz. or 208V./60 Hz., 20 Kw. - Computer. DIMENSIONS AND WEIGHTS AEL-EPP: -Dimensions: 2000 x 400 x 2000 mm. approx. (78.74 x 15.75 x 78.74 inches approx.) -Weight: 50 Kg. approx. (110 pounds approx.) 5

Mechanical Power Plants and Energy Simulator available power plants: 6

Complete Technical Specifications (for optional items) Additionally to the main items (1, 3, 4) described, we can offer, as optional, other items 2 and from 5 to 7. All these items try to give more possibilities for: a) Technical and Vocational Education configuration. (ICAI) b) Multipost Expansions options. (Mini ESN and ESN) a) Technical and Vocational Education configuration 5 AEL-EPP/ICAI. Interactive Computer Aided Instruction Software System. This complete software package consists of an Instructor Software (EDIBON Classroom Manager -ECM-SOF) totally integrated with the Student Software (EDIBON Student Labsoft -ESL-SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. This software is optional and can be used additionally to items (1 to 4). -ECM-SOF. EDIBON Classroom Manager (Instructor Software). Instructor Software ECM-SOF is the application that allows the Instructor to register students, manage and assign tasks for workgroups, create own content to carry out Practical Exercises, choose one of the evaluation methods to check the Student knowledge and monitor the progression related to the planned tasks for individual students, workgroups, units, etc... so the teacher can know in real time the level of understanding of any student in the classroom. Innovative features: User Data Base Management. Administration and assignment of Workgroup, Task and Training sessions. ECM-SOF. EDIBON Classroom Manager (Instructor Software) Application main screen ECAL. EDIBON Calculations Program Package - Formula Editor Screen Creation and Integration of Practical Exercises and Multimedia Resources. Custom Design of Evaluation Methods. Creation and assignment of Formulas & Equations. Equation System Solver Engine. Updatable Contents. Report generation, User Progression Monitoring and Statistics. -ESL-SOF. EDIBON Student Labsoft (Student Software). ESL-SOF is the application addressed to the Students that helps them to understand theoretical concepts by means of practical exercises and to prove their knowledge and progression by performing tests and calculations in addition to Multimedia Resources. Default planned tasks and an Open workgroup are provided by EDIBON to allow the students start working from the first session. Reports and statistics are available to know their progression at any time, as well as explanations for every exercise to reinforce the theoretically acquired technical knowledge. Innovative features: Student Log-In & Self-Registration. Existing Tasks checking & Monitoring. Default contents & scheduled tasks available to be used from the first session. Practical Exercises accomplishment by following the Manual provided by EDIBON. Evaluation Methods to prove your knowledge and progression. Test self-correction. Calculations computing and plotting. Equation System Solver Engine. User Monitoring Learning & Printable Reports. Multimedia-Supported auxiliary resources. For more information see ICAI catalogue. Click on the following link: /products/catalogues/en/icai.pdf ERS. EDIBON Results & Statistics Program Package - Student Scores Histogram ESL-SOF. EDIBON Student Lab- Soft (Student Software) Application Main Screen ERS. EDIBON Results & Staticstics Program Package-Question Explanation ETTE. EDIBON Training Test & Exam Program Package - Main Screen with Numeric Result Question Student Software EPE. EDIBON Practical Exercise Program Package Main Screen ECAL. EDIBON Calculations ProgramPackage Main Screen 7

b) Multipost Expansions options 6 Mini ESN. EDIBON Mini Scada-Net System. Mini ESN. EDIBON Mini Scada-Net System allows up to 30 students to work with a Teaching Unit in any laboratory, simultaneously. It is useful for both, Higher Education and/or Technical and Vocational Education. The Mini ESN system consists of the adaptation of any EDIBON computer controlled unit with SCADA integrated in a local network. This system allows to view/control the unit remotely, from any computer integrated in the local net (in the classroom), through the main computer connected to the unit. Then, the number of possible users who can work with the same unit is higher than in an usual way of working (usually only one). Main characteristics: -It allows up to 30 students to work simultaneously with the EDIBON Computer Controlled Unit with SCADA, connected in a local net. -Open Control + Multicontrol + Real Time Control + Multi Student Post. -Instructor controls and explains to all students at the same time. -Any user/student can work doing "real time" control/multicontrol and visualisation. -Instructor can see in the computer what any user/student is doing in the unit. -Continuous communication between the instructor and all the users/students connected. Main advantages: -It allows an easier and quicker understanding. -This system allows you can save time and cost. -Future expansions with more EDIBON Units. For more information see Mini ESN catalogue. Click on the following link: /products/catalogues/en/mini-esn.pdf Mini ESN. EDIBON Mini Scada-Net System Energy Power Plants Trainer (AEL-EPP) Instructors' Central Computer LOCAL NET FOR 30 STUDENTS 1 UNIT= up to 30 STUDENTS can work simultaneously Software for: - Computer Control - Data Acquisition - Data Management Mini Scada-Net Software Note: The Mini ESN system can be used with any EDIBON computer controlled unit 7 ESN. EDIBON Scada-Net System. This unit can be integrated, in the future, into a Complete Laboratory with many Units and many Students. 8

ORDER INFORMATION 1 Unit: AEL-EPP. Energy Power Plants Trainer. 3 Cables and Accessories, for normal operation. 4 Manuals. Main items (always included in the supply) Minimum supply always includes: *IMPORTANT: Under AEL-EPP we always supply all the elements for immediate running as 1, 3 and 4. Optional items (supplied under specific order) 2 PSV-SCADA. Power Systems SCADA Viewer. a) Technical and Vocational configuration 5 AEL-EPP/ICAI. Interactive Computer Aided Instruction Software System. b) Multipost Expansions options 6 Mini ESN. EDIBON Mini Scada-Net System. 7 ESN. EDIBON Scada-Net System. 9

Tender Specifications (for main items) 1 AEL-EPP. Unit. The trainer includes the following modules: N-ALI01. Industrial Power Supply. Supply voltage: 400 VAC, 3PH+N+G ON-OFF removable key Output voltage connections: Three-Phase + Neutral: 400 VAC Single-Phase: 230 VAC Three-Phase supply hose with IP44 3PN+E 32A 400V connecting plug. Differential magnetothermal, 4 poles, 25A, 300mA AC 6KA N-AVR/P. Automatic voltage regulator. Generator excitation regulator. Local/remote control switch. Manual/automatic control switch of the excitation in local mode. Excitation current manual control potentiometer. ON-OFF switch. Connection terminals. Communication connector SUB-D of 62 pins. N-ASY/B. Basic Synchronization Module. Voltage: 400V. Digital Synchronoscope. Synchronization switch. Double frequenzy meter. Double voltmeter. N-SERV1K. 1 kw Servomotor Module. Dynamic and static four-quadrant operation. Speed and torque displays. Four-quadrant monitor. Thermal monitoring of the machine under test. Testing for the presence of a shaft cover. Connection voltage: 400V. Frequency: 50Hz. Maximum power output: 10kVA. Maximum speed: 4000rpm. Maximum torque 30Nm. Temperature monitoring. N-EALD. Network Analyzer Unit with Computer Data Acquisition. ON-OFF switch. Supply voltage: 400 VAC Input terminals: Input connection with the measurement point. Output terminals: Output connection with the measurement point. Digital outputs: Three digital outputs are used for pulses or alarms, or for combining both. RS-485 Communication port. Fuses: 3x10 A Network Analyzer Display. It shows: Active, reactive and apparent power. Active, reactive and apparent energies. Lines and phase currents. Line and phase voltages. Frequencies. Power Factor. N-ERP-PGC02. Automatic Voltage and Frequency Controller. Generator protection relay module. Single-phase supply voltage: 230 VAC. Island grid/parallel grid control switch. Local/remote control switch. Manual control switches of the relay: 1. SW1, emergency stop. 2. SW2, automatic start of the motor-generator group. 3. SW3, protections reset pushbutton. 4. SW4, generator frequency control activation. 5. SW5, 52G1 synchronization circuit breaker closure manual permission. State light indicators. Alarm light indicators. Synchronization safety key. Emergency stop pushbutton. SUB-D signals connector of 62 pins. ON-OFF switch. Connection terminals. The N-ERP-PGC-02 generator protection relay: Enables to connect up to 16 diesel generators in parallel-island with distribution of active and reactive load and start/stop in function of the load demand. Enables to connect one generator in parallel with the grid Enables different switches control modes, such as opening, closing and synchronization. Includes analogical outputs to control voltage and frequency regulators available in the market. Three-phase measurement of the grid and generator voltage. Three-phase measurement of the generator intensity and power. Single-phase measurement of the grid intensity. Protections: Generator: max/mín-voltage (59/27), max/min-frequency (81O/U), voltage asymmetry, dead bus detection, overload (32), unbalance load (46), reverse power/reduce (32R/F), overcurrent time define curve (50/51), inverse time overcurrent (IEC255), fault ground (50N/51N), phases, breakers fault. Motor: over/sub speed (12). Mains: max/min-voltage (59/27), max/min-frequency (81O/U), vector surge. 10

Tender Specifications (for main items) EMT6B/1K. 1KVA three-phase Synchronous generator. Nominal power: 1 kw. Nominal voltage: 3x 400/230 VAC Y/ Δ. Frequency: 50/60 Hz. Number of poles: 4. RPM: 1500 rpm. Nominal current: 2,1/3,65A Y/ Δ. Nominal excitation current: 4A AC ; 11A DC. All necessary cables to realize the practical exercises are included. The complete unit and optional PSV-SCADA includes as well: Advanced Real-Time PSV-SCADA. Open Control + Multicontrol + Real-Time Control. Specialized EDIBON Control Software based on LabVIEW. Projector and/or electronic whiteboard compatibility allows the unit to be explained and demonstrated to an entire class at one time. Capable of doing applied research, real industrial simulation, training courses, etc. Remote operation and control by the user and remote control for EDIBON technical support, are always included. Totally safe, utilizing 4 safety systems (Mechanical, Electrical, Electronic & Software). Designed and manufactured under several quality standards. Optional ICAI software to create, edit and carry out practical exercises, tests, exams, calculations, etc. Apart from monitoring user's knowwledge and progress reached. This unit has been designed for future expansion and integration. A common expansion is the EDIBON Scada-Net (ESN) System which enables multiple students to simultaneously operate many units in a network. 2 PSV-SCADA. Power Systems SCADA Viewer. Compatible with the industry standards. Flexible, open and multicontrol software, developed with actual windows graphic systems, acting simultaneously on all process parameters. Management, processing, comparison and storage of data. It allows the registration of the alarms state and the graphic representation in real time. Open software, allowing the teacher to modify texts, instructions. Teacher s and student s passwords to facilitate the teacher s control on the student, and allowing the access to different work levels. This unit allows the 30 students of the classroom to visualize simultaneously all the results and the manipulation of the unit, during the process, by using a projector or an electronic whiteboard. 3 Cables and Accessories, for normal operation. 4 Manuals: This unit is supplied with 7 manuals: Required Services, Assembly and Installation, Control Software, Starting-up, Safety, Maintenance & Practices Manuals. 11

Tender Specifications (for main items) Exercises and Practical Possibilities to be done with the Main Items Operations with electrical generator and governor: 1.- Generator island grid operations. 2.- Generator parallel grid operations. 3.- Generator manual voltage regulation operations. 4.- Generator manual frequency regulation operations. 5.- Study of synchronous generator power factor regulation. 6.- Studying of turbine regulation (frequency control) in island mode. 7.- Study of turbine regulation (frequency control) in parallel grid mode. 8.- Study of excitation/voltage regulation in island mode. 9.- Study of excitation/voltage regulation in parallel grid mode. 10.- Analysis of active and reactive power control. 11.- Automatic control of active power. 12.- Automatic control of reactive power. Operations with the frequency and voltage controller working as protection: 13.- Setting of the overcurrent protection of the generator controller. 14.- Setting of the overvoltage and undervoltage protection of the generator controller. 15.- Setting of the reverser power protection of the generator controller. Particular practical exercises related to power plants: Nuclear power plant simulator. 16.- Demostration the working principles and operations of nuclear power plants simulator during varying loads. Hydroelectric power plant simulator. 17.- Demonstration the working principles of mechanism of hydroelectric power plant simulatior. 18.- Manual water flow control. 19.- Automatic water flow control. Ocean energy power plant simulator. 20.- Demonstration of working principles and the way of how energy is stored. Combined Cycle power plant simulator. 21.- Demonstration the working principles of mechanism of combined clycle power plant simulator. 22.- Manual water flow control. 23.- Automatic water flow control. Diesel fuel power plant simulator. 24.- Demonstration the working principles of mechanism of diesel fuel clycle power plant simulator. 25.- Manual fuel flow control. 26.- Automatic fuel flow control. Fossil fuel power plant simulator. 27.- Demonstration the working principles of mechanism of fossil fuel power plant simulator. 28.- Manual fosil control. 29.- Automatic fosil control. Gas power plant simulator. 30.- Demonstration the working principles of mechanism of gas power plant simulator. 31.- Manual gas flow control. 32.- Automatic gas flow control. Wind powered power plant simulator. 33.- Demonstration the working principles of mechanism of wind powered power plant simulator. 34.- Manual wind flow control. 35.- Automatic wind flow control. Photovoltaic power plant simulator. 36.- Demonstration the working principles of mechanism of photovoltaic power plant simulator. 37.- Manual irradiation control. 38.- Automatic irradiation control. Biomass power plant simulator. 39.- Demonstration the working principles of mechanism of biomass power plant simulator. 40.- Manual biomass control. 41.- Automatic biomass control. Fuel cells power plant simulator. 42.- Demonstration the working principles of mechanism of biomass power plant simulator. 43.- Manual hydrogen flow control. 44.- Automatic hydrogen flow control. Geothermal power plant simulator. 45.- Demonstration the working principles of mechanism of biomass power plant simulator. 46.- Manual water flow control. 47.- Automatic water flow control. Heliothermic Solar Power Plant Simulator. 48.- Demonstration the working principles of mechanism of Heliothermic Solar Power Plant Simulator. 49.- Manual solar irradiation control. 50.- Automatic solar irradiation control. Steam Turbine Power Plant Simulator 51.- Demonstration the working principles of mechanism of Steam Turbine Power Plant Simulator 52.- Manual steam flow control. 53.- Automatic steam flow control. Other possibilities to be done with this Unit: 54.- Many students view results simultaneously. To view all results in real time in the classroom by means of a projector or an electronic whiteboard. 55.- The Computer Control System with PSV-SCADA allows a real industrial simulation. 56.- This unit is totally safe as uses mechanical, electrical and electronic, and software safety devices. 57.- This unit can be used for doing applied research. 58.- This unit can be used for giving training courses to Industries even to other Technical Education Institutions. - Several other exercises can be done and designed by the user. 12

5 AEL-EPP/ICAI. Interactive Computer Aided Instruction Software System. This complete software package consists of an Instructor Software (EDIBON Classroom Manager -ECM-SOF) totally integrated with the Student Software (EDIBON Student Labsoft -ESL-SOF). Both are interconnected so that the teacher knows at any moment what is the theoretical and practical knowledge of the students. -ECM-SOF. EDIBON Classroom Manager (Instructor Software). ECM-SOF is the application that allows the Instructor to register students, manage and assign tasks for workgroups, create own content to carry out Practical Exercises, choose one of the evaluation methods to check the Student knowledge and monitor the progression related to the planned tasks for individual students, workgroups, units, etc...so the teacher can know in real time the level of understanding of any student in the classroom. Innovative features: User Data Base Management. Administration and assignment of Workgroup, Task and Training sessions. Creation and Integration of Practical Exercises and Multimedia Resources. Custom Design of Evaluation Methods. Creation and assignment of Formulas & Equations. Equation System Solver Engine. Updatable Contents. Report generation, User Progression Monitoring and Statistics. -ESL-SOF. EDIBON Student Labsoft (Student Software). ESL-SOF is the application addressed to the Students that helps them to understand theoretical concepts by means of practical exercises and to prove their knowledge and progression by performing tests and calculations in addition to Multimedia Resources. Default planned tasks and an Open workgroup are provided by EDIBON to allow the students start working from the first session. Reports and statistics are available to know their progression at any time, as well as explanations for every exercise to reinforce the theoretically acquired technical knowledge. Innovative features: Student Log-In & Self-Registration. Existing Tasks checking & Monitoring. Default contents & scheduled tasks available to be used from the first session. Practical Exercises accomplishment by following the Manual provided by EDIBON. Evaluation Methods to prove your knowledge and progression. Test self-correction. Calculations computing and plotting. Equation System Solver Engine. User Monitoring Learning & Printable Reports. Multimedia-Supported auxiliary resources. b) Multipost Expansions options 6 * Tender Specifications (for optional items) a) Technical and Vocational Education configuration Mini ESN. EDIBON Mini Scada-Net System. EDIBON Mini Scada-Net System allows up to 30 students to work with a Teaching Unit in any laboratory, simultaneously. The Mini ESN system consists of the adaptation of any EDIBON Computer Controlled Unit with SCADA integrated in a local network. This system allows to view/control the unit remotely, from any computer integrated in the local net (in the classroom), through the main computer connected to the unit. Main characteristics: - It allows up to 30 students to work simultaneously with the EDIBON Computer Controlled Unit with SCADA, connected in a local net. - Open Control + Multicontrol + Real Time Control + Multi Student Post. - Instructor controls and explains to all students at the same time. - Any user/student can work doing "real time" control/multicontrol and visualisation. - Instructor can see in the computer what any user/student is doing in the unit. - Continuous communication between the instructor and all the users/students connected. Main advantages: - It allows an easier and quicker understanding. - This system allows you can save time and cost. - Future expansions with more EDIBON Units. The system basically will consist of: This system is used with a Computer Controlled Unit. - Instructor s computer. - Students computers. - Local Network. - Unit-Control Interface adaptation. - Unit Software adaptation. - Webcam. - Mini ESN Software to control the whole system. - Cables and accessories required for a normal operation. Specifications subject to change without previous notice, due to the convenience of improvement of the product. REPRESENTATIVE C/ Del Agua, 14. Polígono Industrial San José de Valderas. 28918 LEGANÉS. (Madrid). SPAIN. Phone: 34-91-6199363 FAX: 34-91-6198647 E-mail: edibon@edibon.com WEB site: Edition: ED01/17 Date: April/2017 13