Air Flow Controller M1compact Type-Summary FKM 130

Similar documents
JUMO MIDAS Pressure transmitter

Electronic Flow Monitor for liquids

JUMO MIDAS S05 Pressure transmitter Type

Level Limit Switch liquiphant FTL 365 / FTL 366

Level Limit Switch liquiphant FTL 360 / FTL 361

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

Steering column and sensor

Operating instructions Flow monitors SI6000 SI6100 SI /00 06/2011

JUMO ecotrans Lf 01/02


Electronic Pressure Switches

Flow meters. Flow meters. Flow meters - Continuous and precise measurement of flow rates

Paddle-wheel flow controller with optical principle for On/Off control

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Electronic Pressure Switches

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Level Limit Switch soliphant FTM 930/931/932/ Z

Pressure Transmitter JUMO dtrans p30 Type

Electronic Pressure Switch EDS 3000

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

better measurement Simply a question of

Electronic Ballast EVG 2000-T

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

Paddle-wheel flow controller for On/Off control

Operating instructions Flow monitors SI6600 SI6700 SI /02 01/2011

Red/green-LED for switching state indication (dyn.) Yellow LED for dirt accumulation indication

VALVE CONTROLLERS Controllers for Dust Extr 2010 / 2011 action Technology

BRIDGE-BOY Load limitation electronics with 1 or 3 set points

ACTUATORS POSITION SENSOR

Related vacuum products

Temperature switch. Switching output 2 transistors PNP Logger Ring buffer: 3518 data points Sampling time: s, Off (0)

Page 1/6. Temperature sensor baelz 61 with questionnaire for inquiries on page 5 DS 61, 251

Operating Instruction for Electronic Pressure Switch. Model: PDD

Safety Sensor CSS 180 Product Information

Operating instructions Flow monitors SI5000 SI / / 2007

Differential Pressure Sensors

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Electronic Pressure Switches

2-Color Display High-Precision Digital Pressure Switch

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

Positive displacement batch controller

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

DPS280 / DVS280 Series

Paddle-wheel flow controller for On/Off control

better measurement Simply a question of

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

RI360P0-QR24M0- INCRX2-H1181 Contactless Encoder Incremental

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Directional servo-valve in 4-way design

The right choice for your application. Pressure sensors from ifm.

Operating instructions Binary level sensor. LI214x /00 04/2016

Bulletin 871P Can Sensors

Technical Data Sheet

Pressure Transmitter JUMO dtrans p30 Type

ISE6B. Series ZSE6B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

Electronic Pressure Switches

Electronic pressure switch. Type HEDE 10. Contents. Features. RE Edition: Replaces:

Data Sheet. I/P and E/P converters. RS stock numbers ,

Contactless Encoder with Stainless Steel Housing Incremental: ppr RI360P0-EQR24M0- INCRX2-H1181

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

DIAMOND POINT VIBRATING PROBES

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

GRUNDFOS PRODUCT GUIDE. Redi-Flo3 and CU 300. Environmental Pumps 60Hz

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Operating Instructions. Angle Seat Control Valve. Type 7020

JUMO dtrans p35. Pressure Sensor with IO-Link. Application. Brief description. Customer benefits. Special features

Flowmeter Ultrasonic Flow Metering / Dosing Device. Operating Manual

Flow - dynamic diaphragm

SENSOR COMPETENCE AN OVERVIEW

Flow sensors. 324 Hans Turck GmbH & Co. KG Tel Fax

CAPACITIVE SEnSorS 2018

Electronic pressure switch with two switching outputs

Operating Instructions for Polysulfone Paddle Monitor. Model: PPS-..

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Differential pressure sensor

Flow Monitors and Sensors

3/3 servo directional control valve with mechanical position feedback

FLOWX3 F3.20 High Pressure Paddlewheel Flow Sensor MAIN FEATURES APPLICATIONS OPERATING PRINCIPLE

Flow - rotor, inline model

Intelligent Positioner

Pressure transmitter for elevated media temperatures

Flow - magnetic inductive - probe form

Pressure Gauge. Fluid admitted Pressure indication range Accuracy Service temperature range Cap. Resin body GPC (1)

Magnetic Field Sensor for pneumatic cylinders BIM-UNT-AP6X-0.3-RS4

ARI-PACO 2G 1,6 D/Y. Electric thrust actuator. Electric thrust actuator ARI-PACO 2G 1,6 D/Y. Electric thrust actuator. ARI-PACO 2G 1,6 D 1,6 kn

Series P directly operated solenoid valves

Pressure sensor for liquid and gaseous media QBE620-P...

Simply a question of better measurement

Linear actuator. Product features. Overview. Wide range of force outputs. Wide selection of column adapters. Wide selection of flanges

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

Technical Data Measuring principle Thin-film-on-steel Media temperature -40 C C

Compressed air counter DN

Product specification

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

Transcription:

Air Flow Controller M1compact -Summary FKM 130 One-part sensor for controlling air and gaseous flows with integrated evaluation electronic. The air flow controller is mounted into the flow to be controlled as a stationary sensoring unit with the flange or a PG 21 union. The calorimetrically working unit with integrated evaluation electronic offers maintenance-free operation. The sensor is available as switching unit with different output variations for controlling a limit flow value as well as with analogous output. Switching Output with S. C. P. technology FKM 130.10 G FKM 130.11 G FKM 130.12 G FKM 130.13 G 8005A 8006A 8007A 8008A NPN n. c., 3 wire NPN n. o., 3 wire PNP n. c., 3 wire PNP n. o., 3 wire Switching Output without S. C. P. technology FKM 130.10 FKM 130.11 FKM 130.12 FKM 130.13 8001A 8002A 8003A 8004A NPN n. c., 3 wire NPN n. o., 3 wire PNP n. c., 3 wire PNP n. o., 3 wire Analogous Output Output FKM 130.19 8009A 0-10 V The value of 3 m/s adjusted in the factory is preferred in the branches of building technology and constructional engineering, however it can be set subsequently to values between 1 and 10 m/s. After applying the supply voltage the FKM 130 needs a start-up time delay of 3 minutes. After this delay the switching output (red ) indicates the real condition of flow. The normally open version switches through and the red gives light when the limit value for flow is exceeded and opens if the flow falls below the set value (inverse behaviour of normally close versions). A mounting flange is included in the scope of supply. Alternatively suitable clips or a Pg 29 cable union can be used for pressure-tight assembly. The sensor must protrude approx. 25 mm (1 inch) into the air duct. The ceramic vane should be parallel to the air flow. Small deviations in vane orientation do not affect operation. Quick changes of temperature can result in misswitchings for a short time. (Switching Output) Adjusting range 1-10 m/s Set limit value 3 m/s max. 15 s Starting time 3 min 24 V DC 0-200 ma yes No load current 50 ma 2 V Switching hysteresis max 30 % Ambient temperature -10... +60 C Protection class IP 65 Housing material (Analogous Output) Output 0-10 V (R L > 5 KΩ) Measuring range 0-16 m/s 15 s (t 90) Starting time 5 min 24 V DC Power absorption 40 ma Ambient temperature 0... +50 C Protection class IP 65 Housing material 16.03.1999 Details are subject to change without notice. WG 800 F60E

Air Flow Controller (DC) FKM 130.13 GD One-part sensor for controlling air and gaseous flows with integrated evaluation electronic. The calorimetrically working unit offers maintenance-free operation. FKM 130.13 GD 8008E Output PNP n. o. Adjusting range 1-10 m/s Set limit value 3 m/s max. 15 s Starting time 3 min 24 V DC 0-200 ma yes No load current 50 ma 2 V Switching hysteresis max 30 % Ambient temperature -10 to +60 C Protection class IP 65 Terminal chamber with PG 13,5 Housing material Flat seal for pressure-resistant assembly included in the scope of supply. Additional seals available on request: Seal for nominal pipe width Ø 80 mm 026009 Seal for nominal pipe width Ø 100 mm 026010 Diagram of s 16.03.1999 Details are subject to change without notice. WG 800 F61E

Air Flow Controller M2compact -Summary FKM 230 One-part sensor for controlling air and gaseous flows with integrated evaluation electronic. The calorimetrically working unit in a hermetically closed casing of insulation material offers maintenance-free operation. DC 24 V DC 24 V plug S4 ( M12x1 ) technology technology FKM 230.10 G FKM 230.11 G FKM 230.12 G FKM 230.13 G 8035A 8034A 8033A 8032A NPN n. c. 3-wire NPN n. o. 3-wire PNP n. c. 3-wire PNP n. o. 3-wire FKM 230.10 G S4 FKM 230.11 G S4 FKM 230.12 G S4 FKM 230.13 G S4 8035B 8034B 8033B 8032B NPN n. c. 3-wire NPN n. o. 3-wire PNP n. c. 3-wire PNP n. o. 3-wire AC 110 V technology FKM 230.52 8039A n. c. 3-wire FKM 230.53 8038A n. o. 3-wire AC 230 V technology FKM 230.82 8037A n. c. 3-wire FKM 230.83 8036A n. o. 3-wire All DC-types available without short circuit protection. number without G. Adjusting range 1-10 m/s 2 V Set limit value 3 m/s DC/AC 0-200 ma / 0-300 ma max. 10 s Switching hysteresis max. 15 % Readiness delay 30 s Measuring principle calorimetric DC/AC yes / no yes Protection class IP 67 Ambient temperature - 10 bis +60 C No load current 30 ma Housing material The value of 3 m/s witch is set in the factory is a preferred value in the ranges of building technology and mechanical engineering, however it can subsequently be set to values between 1 and 10 m/s. After applying the service voltage (the green lightens) the output simulates an existing flow for 30 seconds. After this readiness delay the switch output gives a signal and the yellow indicates the actual condition of flow. The normally open version switches through and the yellow lightens, when the limit value of flow is exceeded and opens when the flow falls below the limit value (inverse behaviour in case of normally close versions). The response time of 10 seconds also applies to unfavourable flow conditions and thus protects safe and quickly all kinds of installations from damage. The air flow controller is mounted in such a way that the air can flow onto the plane measuring surface (diameter 20 mm) from random direction. For effective temperature compensation the cylindrical part must be exposed to the same ambient temperatures 30 mm upto the measuring surface. Quick changes of temperature can result in misswitchings for a short time. A mounting flange is included in the scope of supply. Alternatively suitable clips or a Pg 29 cable union can be used for pressure-tight assembly. 16.03.1999 Details are subject to change without notice. WG 800 F49E

Analogous Air Flow Controller FKM 230.19 The air flow controller is mounted into the flow to be controlled as a stationary sensoring unit with the flange or a PG 29 union. The air flow produces an output signal which is proportionate to the velocity. The heated flow sensors are arranged below the face of the hermetically closed casing of insulating material. Thanks to the calorimetrical measuring principle with electronic evaluation maintenance-free operation is possible. FKM 230.19 8027A Output 0-10 V (R L > 10 K) Measuring range 0-16 m/s Resolution 0,01 m/s Exactitude +/- 5 % Temperature error 0,5 %/K 15 s (t 90) Starting time 5 min 24 V DC +10 % / -15 % Power absorption 60 ma Ambient temperature 0 to +50 C Protection class IP 67 Housing material Diagram of s Output voltage/flow rate standard 06.08.1999 Details are subject to change without notice. WG 800 F28E

Air Flow Controller M2compact (AC) FKM 230.53 One-part sensor for controlling air and gaseous flows with integrated evaluation electronic. The calorimetrically working unit in a hermetically closed casing of insulation material offers maintenance-free operation. FKM 230.53 8038A Output normally open Adjusting range 1-10 m/s Set limit value 3 m/s max. 10 s Readiness delay 30 s 110 V AC 0-300 ma no No load current 30 ma 2 V Switching hysteresis max 15 % Ambient temperature -10 to +60 C Protection class IP 67 Housing material Diagram of s The value of 3 m/s witch is set in the factory is a preferred value in the ranges of building technology and mechanical engineering, however it can subsequently be set to values between 1 and 10 m/s. After applying the service voltage (the green lightens) the output simulates an existing flow for 10 15 seconds. After this readiness delay the switch output gives a signal and the yellow indicates the actual condition of flow. The normally open version switches through and the yellow lightens, when the limit value of flow is exceeded and opens when the flow falls below the limit value (inverse behaviour in case of normally close versions). The response time of 10 seconds also applies to unfavourable flow conditions and thus protects safe and quickly all kinds of installations from damage. The air flow controller is mounted in such a way that the air can flow onto the plane measuring surface (diameter 20 mm) from random direction. For effective temperature compensation the cylindrical part must be exposed to the same ambient temperatures 30 mm upto the measuring surface. Quick changes of temperature can result in misswitchings for a short time. A mounting flange is included in the scope of supply. Alternatively suitable clips or a Pg 29 cable union can be used for pressure-tight assembly. 16.03.1999 Details are subject to change without notice. WG 800 Proxitron GmbH - Gärtnerstr. 10 - D-25335 Elmshorn - Tel. 04121/2621-0 - Fax. 04121/24404 - mail@proxitron.de F 38E

Air Flow Controller FKM 230.18 G S4 This air flow controller controls two independently adjustable limit values upto a flow velocity of 30 m/s. Short-circuit-proof normally open and normally close outputs as well as twocolour s indicate when the values exceed or fall below the desired range. So troubles such as flow failure, hose rupture and required exchange of filter can be monitored in installations of inflow technique. Normally open ( and potentiometer at the left, 20 pitches): output connected through and given green light at min. flow existing; red flow failure. Normally close ( and potentiometer at the right, 20 pitches): output connected through and giving green light at value fallen below the max. flow; red = flow too high. FKM 230.18 GS4 Art.-Nr. 8041A Output PNP n. o. + n. c. Adjusting range normally open 1-30 m/s Adjusting range normally close 8-30 m/s Measuring principle calorimetric < 10 s Readiness delay after applying the supply voltage both outputs are connected 30 s during this time both s give green intermittent light. 24 V DC +10 / -15% Ripple voltage max. 15% 0-400 ma Short-time load current 4 A / 100 ms yes, pulsing No-load current 50 ma 1,5 V Switching hysteresis 0,5-2 m/s Ambient temperature -10... +60 C Protection class IP 65 plug Lumberg M12 2 s 2-colour Housing material sensor part electronic part with flange aluminium Weight 200 g Diagram of s The air flow controller is mounted in such a way that the air can flow onto the plane measuring surface (diameter 20 mm) from random direction. For effective temperature compensation the cylindrical part must be exposed to the same ambient temperatures 30 mm upto the measuring surface. Quick changes of temperature can result in misswitchings for a short time. 17.11.98 Details are subject to change without notice. WG 800 F22E

Air Flow Controller M2compact (DC) FKM 231.13 G One-part sensor for monitoring air flows with integrated evaluation electronics. The calorimetically working devices makes possible maintenance-free operation due to its teach-in function. FKM 231.13 G 8043A Output PNP n. o. Adjusting range 1-16 m/s Set limit value 3 m/s 2 10 s Readiness delay 30 s 24 V DC 0-200 ma yes No load current < 40 ma < 2 V Switching hysteresis max 15 % Ambient temperature -10 to +60 C Protection class IP 67 Duo- red/green Housing material Diagram of s in the scope of the delivery. Alternatively you can use customary clips or cable unions (PG 21). The flow limit set to 3 m/s by the factory is preferred in the ranges of building technology and mechanical engineering, however it can be adapted to the application requirements by it s TEACH-IN pushbutton. TEACH-IN: Expose the air flow controller to the flow in question for at least 5 minutes. Keep push-button pressed for 3 seconds, until the gives green blinking light. Now the sensor stores the new flow limit value permanently and independent from the mains supply. In order to avoid that normal changes in the flow during operation result in wrong switchings half the value of the flow in question is stored as limit value. Example: flow value 10 m/s, stored limited value approx. 5 m/s. Operation: After applying the service voltage ( gives green light) the output simulates existing flow for 30 seconds. After this delay the switching output indicates the real flow condition. The normally-open version switches through ( gives green light) when the flow limit value is exceeded and opens when the value falls below the limit value ( gives red light) (inverted behaviour of the switching output in case of the normally-close version). Installation: The air flow controller is installed in such way that the flow can reach the plane measuring surface (Ø20mm) from any direction. For proper temperature compensation 30 mm of the cylindrical part up to the measuring surface must be exposed to the same ambient temperatures. Quick changes of temperature can result in short-time wrong switchings. A mounting flange is included 13.02.2002 Details are subject to change without notice. WG 800 Proxitron GmbH - Gärtnerstr. 10 - D-25335 Elmshorn - Tel. 04121/2621-0 - Fax. 04121/24404 - mail@proxitron.de F70E

Flow Sensor F6 FKE 604.18 G The flow sensor controls liquid media and indicates flow failure resp. deviation from a free adjustable flow velocity. The sturdy stainless steel casing serves for heat transfer in the calorimetrical measuring principle. The integrated electronic unit makes possible: simple commissioning safe detection of condition maintenance-free operation s show the required safety margin for operation, i. e. if the difference between the flow existing and the limit value set renders possible a trouble-free operation FKE 604.18 G 8382A Output PNP n. o. / n. c. switchable Adjusting range 30-3000 mm/s Pressure resistance 100 bar approx. 1 to 15 s Readiness delay 45 s 20-36 V DC 0-400 ma yes, pulsing no load current max. 80 ma 2,5 V Ambient temperature 0 to +80 C storage temperature -40 to +100 C Protection class IP 67 Indication of safety margin for operation ( flashing ) +30 % green 30 % red at approx. 300 mm/s Housing material sensor electronic unit stainless steel V2A 1.4305 Diagram of s green Flow + red Flow - yellow = output +24 V dependent on switch position n. c. n. o. Flow ok., with operation safety margin ok., near to switchpoint low, near to switchpoint failure indication see above output pulsing in case of overload readiness delay after application of service voltage = steady light = flashing 16.03.1999 Details are subject to change without notice. WG 830 F16E

Flow Sensor F6 FKF 704.86 G The flow sensor controls liquid media and indicates flow failure resp. deviation from a free adjustable flow velocity. The sturdy stainless steel casing serves for heat transfer in the calorimetrical measuring principle. The integrated electronic unit makes possible: simple commissioning safe detection of condition maintenance-free operation s show the required safety margin for operation, i. e. if the difference between the flow existing and the limit value set renders possible a trouble-free operation FKF 704.86 G 8393A Output n. o. / n. c. switchable Adjusting range 30-3000 mm/s Pressure resistance 100 bar approx. 1 to 15 s Readiness delay 45 s 230 V AC Power frequency 45-65 Hz 0,5-400 ma yes, pulsing no load current max. 80 ma 2 V Ambient temperature 0 to +80 C storage temperature -40 to +100 C Protection class IP 67 Indication of safety margin for operation ( flashing ) +30 % green 30 % red at approx. 300 mm/s Housing material sensor electronic unit stainless steel V2A 1.4305 Diagram of s green Flow + red Flow - yellow = output +24 V dependent on switch position n. c. n. o. Flow ok., with operation safety margin ok., near to switchpoint low, near to switchpoint failure indication see above output pulsing in case of overload readiness delay after application of service voltage = steady light = flashing 16.03.1999 Details are subject to change without notice. WG 830 F56E

Flow Sensor F6 Control Unit FSP 604.6 R for Sensors FA_6 The flow sensor monitors water and oil circuits in cooling, lubrication and hydraulic plants as well as filling processes in food industry. The control unit for the external flow sensor FA indicates deviations from the adjustable values for flow velocity and temperature. FSP 604.6 R 8383B Flow range ( adjustable ) 30-3000 mm/s Temperature range ( adjustable ) 0-80 C terminal 16/14 230 V AC terminal 16/15 115 V AC terminal 12/13 24 V DC Power frequency 45-65 Hz (at AC) Power absorption max. 5 VA Readiness delay 45 s Output Relay changeover contact Relay contact load max. 5A / 240 V AC Relay function in case of flow Terminals 7/8 open: relay dropped (10/11 closed) Terminals 7/8 connected: relay pulled up (9/10 closed) Temperature control and indication operate permanently. By closing of terminals 5/6 temperature control additionally acts upon the relay. Exceeding the limit value for temperature has the same effect as if the flow value falls below the limit value. Temperature hysteresis 5 K Ambient temperature -20 to +70 C Protection class IP40, terminals IP 20 self-opening terminals as per DIN 461990 upto 4 mm2 Indication of function relay pulled-up yellow Indication of operational margin +30 % green gives intermittent light -30 % red gives intermittent light Casing casing for rail as per DIN 46277 / EN 50022 or 2 boreholes as per DIN 46121 Diagram of s The sensor of series FA... is screwed into a pipe tee and connected with the control unit by a connection cable. Green and red s indicate the states of operation for flow and temperature. lf the values of flow or temperature come close to the limit values, a giving intermittent light indicates if the value falls below the operational margin. Due to this early warning simple adjustment at site is possible. Sensor FA_6 data sheet F31E 16.03.1999 Details are subject to change without notice. WG 830 F30E

Flow Sensor F6 Sensors FA_6 for Control Unit FSP 6 The sensors of series FA are applied for flow and temperature control of liquid media together with an control unit FSP 6 Sensors Thread FAC 601 8373A G 1/4" FACN 601 8370A NPT 1/4" FAE 601 8384A G 1/2" FAEN 601 8368A NPT 1/2" FAF 601 8371A G 3/4" FAFN 601 8367A NPT 3/4" Storage temperature -40... +100 C Protection class IP 67 plug S4 ( M12 x 1 ) Pressure resistance 100 bar Casing material stainless steel V2A (1.4305) Diagram of s Accessories (not included in the scope of supply) cable with injection-moulded angle coupling Length 2 m ST 041-2 9841D 5 m ST 041-5 9841E Cable box for cable 4 x 0,5 mm2 ST 040 9841A Control unit FSP 6 data sheet F30E Dimensions (in mm) FAE 601 Assembly 22.06.2001 Details are subject to change without notice. WG 830 Proxitron GmbH - Gärtnerstr. 10 - D-25335 Elmshorn - Tel. 04121/2621-0 - Fax. 04121/24404 - mail@proxitron.de F31E

Flow Sensor F6 Sensor FA_601 for Control Unit FSP 6 Thread 1/4" FAC 601 FACN 601 8373A 8370A Thread 1/2" FAE 601 FAEN 601 8384A 8368A Thread 3/4" FAF 601 FAFN 601 8371A 8367A 16.03.1999 Details are subject to change without notice. WG 830 F32E