ILLUMINATOR LV. Emergency Lighting Inverter System 175VA through 750VA. Illuminator Series LV Single Phase

Similar documents
Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

Illuminator Series CR NEMA 3R

GLX. Series. 1kW to 16kW Central System

STL. Series. Emergency Lighting Inverter 3kW to 160kW Central System

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

EMEX. Central Battery Systems Emergency Lighting

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

systems Systems Emergency Lighting Inverter 120 or 277V 60 Hz Power

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 10KW 33KW Systems

POWER kva

EON Model EL3 Three Phase Centralized Emergency Lighting Inverter. General Specification 40KW 55KW Systems

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

POWER kva

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Illuminator System Series CIII

Aurora Single Phase Emergency Lighting Inverters

TECHNICAL DATA SHEET KVA UPS Systemss

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Sola 3000 Guide Specifications

EFFEKTA Power Supplies

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

POWERTRONIX QUASAR 5-40 KVA

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Off-Grid Power Solutions EVOLUTION SERIES INVERTER/CHARGERS COMMERCIAL VEHICLES BACKUP POWER

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Technical data sheets

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

TECHNICAL SPECIFICATION FOR A 10 TO 50 KVA THREE PHASE, UNINTERRUPTIBLE POWER SYSTEM WaveRider III

SURE-LITES LIFEWAY II SERIES

Smart-UPS VT APC Smart-UPS VT 30kVA 208V w/4 Batt. Modules, Start-Up 5X8, Internal Maintenance Bypass

INVERTER/CHARGERS Off-Grid Power Solutions

CEPS Series UL924 Emergency Lighting Inverters

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE

ATevo SERIES BATTERY CHARGER

SURE-LITES LIFEWAY II Series C & IPS

AT EVO SERIES BATTERY CHARGER

TLE Series UPS 400/500 kw With eboost Technology

Sola/Hevi-Duty S3K Series Mini-Tower UPS

EVO AT SERIES BATTERY CHARGER

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Liebert PowerSure PSI UPS

INTRODUCING THE NEW MINI INVERTERS BY READY-LITE

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Technical Data Sheets

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

TLE Series UPS 160/200/225/250 kw with eboost Technology

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

RELIABILITY THROUGH TECHNOLOGY

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Three Phase UPS Systems Range: 10 to 500kVA

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

AT SERIES EVO BATTERY CHARGER

TECHNICAL SPECIFICATIONS for. Telecommunication Battery Backup Systems (TBS)

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

Special Specification 6058 Battery Back-Up System for Signal Cabinets

Power+ CLASSIC. 20/30 kva, 3x208 Vac

TLE Series UPS 750/1000 kw With eboost Technology

Technical Data Sheets

EATON 9315 UPS 200 TO 300 KVA Specifications

Uninterruptible Power Supplies

D Series: UPS UPTO - 300KVA - Three / Three Phase

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

Liebert GXT-MT 1-3kVA UPS. Power Protection for Business Critical Continuity

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Uninterruptible Power System

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

OFF-GRID PV INVERTERS EssenSolar & Expert series. 1kW-5kW. Solution on Unstable or Remote Area without Utility

PowerValue 11/31 T kva

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS

Technical Specification SENTINEL PRO

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Master DIALOG INDUSTRY RANGE

TOSHIBA /20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

Liebert GXT VA RT230 Rack-Tower model GUIDE SPECIFICATIONS 1.0 GENERAL

Liebert GXT & 6000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

Technical Data Sheets

Technical Data Sheets

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Technical Data Sheets

On-line, Single Phase, Double Conversion UPS

1.1 GENERAL CHARACTERISTICS

Uninterruptible Power Systems

Series 120/120VAC Universal Tower/Rack Mount

Transcription:

ILLUMINATOR LV Emergency Lighting Inverter System 175VA through 750VA Illuminator Series LV Single Phase

ILLUMINATOR SERIES LV The Illuminator Series LV is a 175VA-750VA fast transfer Emergency Lighting Inverter utilizing Myers Power Products advanced technology. The Illuminator LV is designed to support the needs of smaller facilities and those now utilizing LED lighting technology. This system meets all requirements of UL924 including self-testing and is listed by UL (Underwriters Laboratories). In addition, the optional meter panel feature of this system will allow the end user to meet the advanced testing & logging requirements as defi ned by NFPA101. The ability to support any lighting source including, but not limited to LED, Fluorescent, and HID enhances the ability of the end user to design the space for the fi t, form, and function they desire. The Illuminator LV (as well as all of the Myers Power Products family of Emergency Lighting Inverters) is designed so that any light fi xture that is appropriate for your facility can be chosen and used for both normal and emergency lighting. This means that the architectural features and design of a space do not have to be compromised by the use of additional types of fi xtures added solely to meet the emergency lighting requirements. The Illuminator Series LV design is highly effi cient, minimizing the overall operating costs of your emergency lighting system. The design utilizes fast transfer technology which is an offl ine 2mS transfer system; able to support all lamp sources, the offl ine system is extremely reliable and effi cient making it exceptionally economical to own and operate. With a substantially smaller footprint, this unit is available in 4 distinct capacities (175W, 350W, 550W, and 750W) and can be either wall or fl oor mounted. In addition, the 175 watt system is available in an optional ceiling grid mounted version where it is designed to be plenum rated. See page 5 for dimensions or visit our website at www.myerspowerproducts.com. STANDARD VERSUS ADVANCED SYSTEM CODE COMPLIANCE Photos 2 Advanced Systems: The advanced (Model Type 2 and 3) LV Series inverter is compliant with UL924 self-testing standards as well as NFPA101 self-testing standards. This system comes complete with a programmable meter panel (system mounted, remote mounted or handheld). This system performs a 5 minute runtime test 11 times a year and, a 90 minute runtime test 1 time a year. The dates and times of these tests are fully programmable by the end user. This system captures the last 25 tests in its internal test log. In addition to the advanced testing functions, this system allows complete access to a wide variety of data regarding the status of the system through the meter panel. Standard Systems: Myers standard (Model Type 1) LV Series inverter is compliant with UL924 self-testing standards. It is provided with a self-test feature that runs a test every 28 days and one extended yearly runtime test. This test is not programmable and is controlled by an internal clock embedded in the system electronics. After a successful completion of either of these tests the systems will indicate as such by illuminating the Ready LED indicator light. If a failure of either of these tests occurs, the Ready LED indicator will fl ash. There is no record or log of these tests. A complete list of functions is available in the Metering Manual on Myers website at www.myerspowerproducts.com. Standard Model Type 1 Advanced Model Type 2 and 3 Testing Metering Data Logging Alarms UL924 Self-Testing/ not available not available Visual Self-Diagnostic UL924 Self-Testing/ Self-Diagnostic NFPA101 Self-Testing/ Self-Diagnostic System mounted, remote mounted, or hand-held Alarm log, event log, test log Audible and Visual 1

ADVANCED SYSTEM DESIGN FEATURES NFPA 101 self-testing, self-diagnostic, and logging OLED display system mounted meter panel provides access to systems logs and programming (Remote and handheld options available). See page 4 of the ordering guide Control panel has an easy to use 4-button keypad which is used to access all information Metering function and system status allows access to a multitude of data regarding the electrical characteristics of the system including input voltage, input current, input frequency, output voltage, output current, output power, battery voltage, battery current, battery temperature, battery power, internal ambient temperature, heat sink temperature, UPS events, UPS time and system days online System setup allows the user to set parameters and customize settings that can indicate out of tolerance conditions Monthly and yearly tests can be programmed by the user to meet the date and time requirements of the facility In addition to basic alarms, advanced alarms include: input frequency low, input frequency high, input voltage low, input voltage high, output voltage low, output voltage high, battery voltage low, battery voltage high, battery temp low, battery temp high, ambient temp low, ambient temp high, and on inverter timer STANDARD SYSTEM DESIGN FEATURES PWM/MOSFET pure sine wave inverter technology Microprocessor controlled 90 minute runtime High effi ciency; no fans required UL 924 listed UL 924 self-testing and self-diagnostic Field selectable voltage; 120 volt input/output or 277 volt input/output Compatible with all light sources including LED, HID, Fluorescent, Incandescent, Quartz and Electronic Low Voltage Lighting High Crest Factor inrush capabilities Red Wall Mounted cabinet (other mounting options and colors available; see ordering guide page 4) Maintenance free VRLA batteries System Status indicators and momentary test switch Input fuse and battery fuse protection Summary Alarm Form C dry contacts Available outputs: normally on and 1 normally off or switched output Normally off has an available 15 minute time delay Output circuit breakers are available for 350, 550 and 750W models Alarms include monthly test fault, yearly test fault, charger fault, load reduction fault, output voltage low, output voltage high, overload fault, low voltage disconnect, heatsink over temp and input fuse failure 2

ADVANCED SYSTEM OPTIONS VARIABLE TIME DELAY Allows for programmable delay of inverter retransfer to continue supplying emergency power to the normally off output for up to 15 minutes after the return of power OUTPUT CIRCUIT BREAKERS Maximum output breakers available: 750 watt system 6 total, 350/550 watt system 3 total, 175 watt system 0 available. Normally on, normally off, and switched options available BACNET Allows for communications of data from the inverter using BACnet protocol. Myers user configurable system is a full MS/ TP master slave device USB MASS STORAGE Provides additional storage capabilities for up to 3000 alarms and 60 test logs. USB option allows for system logs to be copied to USB flash drive for import to data management program (software included). This option expands the capabilities of internal data and alarm logging METERING PANELS Available in three configurations: System mounted, Remote mounted, and Handheld FAST CHARGE A battery charger upgrade which decreases the time to recharge a fully discharged battery bank to a full charge. The recharge time is decreased from the standard 24-hour period to a 12-hour period MOUNTING Wall mount (standard); optional recessed wall mount and plenum rated grid mount (175 watt only) and floor mount (350/550/750) PROGRAMMABLE INPUT / OUTPUT OPTIONS STATUS MONITORING CONTACTS (FACTORY PRESET TO LISTED ALARMS (Option C )) AC Present, Inverter On/Off, Test Failure, System Overload, Near Low Batery, Blown Fuse Indicator AVAILABLE STATUS MONITORING CONTACTS (6 MAXIMUM IN SYSTEM WITHOUT SWITCHED OUTPUT) On Battery, Charger Failure, Overcurrent, AC Present, Monthly/Yearly test failure, Load reduction alarm, System overload, Input voltage high/low, Output current, High ambient temperature, High battery temperature, Inverter ON/OFF, Near low battery, Blown fuse indicator SWITCHED OUTPUT CIRCUIT BREAKERS Up to 3 separate switched 10 amp output circuit breakers. The number of switched outputs will reduce available contact relays (see chart on page 4) ZONE MONITORING (Option Z ) Monitors AC power presence in a specific zone (area, distribution panel, etc.). Upon loss of power in the zone(s), the inverter will turn on, activating all normally off (emergency only) circuits. All normally on loads will remain on. When primary power returns in the zone(s), inverter will turn off after its preset delay and normally off loads will turn off. Consult factory for quantity limits per application. 3

ORDERING GUIDE Example Model Number LV-2-R-2-B2003-F-HH LV 2 R 2 B 20 03 F HH SYSTEM TYPE 1 LV - Illuminator Series LV 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. VA/W 2 1-175 2-350 3-550 4-750 MODEL TYPE ENCLOSURE COLOR 8 R - Red (Standard) W - White G - Grey B - Black 1 - Standard (UL924) 7 2 - Internal Meter Panel and Advanced Testing & Logging (UL924 & NFPA101) 3 - Advanced Testing & Logging (UL924 & NFPA101) 5, 7 Wall Mounted Unit is Standard VA=W Normally off not available when using switched output Requires Model Type 3 Requires HH or RMP option to retrieve data 175W OCB s not available, 350/550W 3 OCB s max, 750W 6 OCB s max No meter panel included Grid mounted system standard color is white All other models, standard color is red Optional colors available Internal meter panel is not available with grid mount cabinet Maximum of 3 switched outputs, each with 10 amp circuit breaker on Type 2 & 3 systems, only 1 switched output is available on Type1 system Multiple switched outputs limit available alarm contacts (see chart below) Requires Model Type 2 or 3 Options Not available with options "C","Z" or systems with more than 1 switched output Not available with options "H","Z" or systems with more than 1 switched output 9 OUTPUT OUTPUT BREAKERS Example: B 20 03 X - None B - Normally On N - Normally Off S - Switched AMP RATING 5, 10, 15, 20 QUANTITY 1-6 6 3, 10 3 ACCESSORIES HH - Handheld Meter Panel (one HH can be used for multiple units) RMP - Remote Meter Panel (1 per system) (requires model type 3) 6 4 OPTIONS B - Floor Mount (not available on 175 watt) C - Status Monitoring Contacts (see chart below) 12, 14 D - NEMA 2R Drip Top F - Fast Charge Option 12 8, 9 G - Grid Mount (175 watt only) H - BACnet 12, 13 R - Infrared Remote Test S - Battery Strapping U - USB Mass storage 12 W - Recessed wall mount (175 watt only) Z - Zone Monitoring 12 AVAILABLE OUTPUT CIRCUIT BREAKER AND OPTIONS CONFIGURATIONS Output Circuit Breaker Available Configurations for 350/550/750 VA systems Quantity of available Form C contacts Zone Monitor inputs available Status Monitoring Option "C" BXX01 6 0 Available BXX01 3 3 Not Available BXX02 6 0 Available BXX02 3 3 Not Available BXX03 6 0 Available BXX03 3 3 Not Available S1001 2 2 Not Available S1001 6 0 Available S1001-BXX01 2 2 Not Available S1001-BXX01 6 0 Available S1001-BXX02 2 2 Not Available S1001-BXX02 6 0 Available S1002 1 1 Not Available S1002-BXX01 1 1 Not Available S1003 0 0 Not Available XX = Breaker amperage (5,10,15 or 20A Available) B = Normally On breaker S= Switched Output circuit breaker(s) (10A Breaker only available). 750 VA system, 3 additional Normally On Output Circuit Breakers are available If Normally Off Breakers are required contact factory for assistance 4

SYSTEM SPECIFICATIONS 17.75 14.25 ILLUMINATOR LV-1 6.5 22 9.25 19 ILLUMINATOR LV-2 & LV-3 22 8 Height 7.5 23.84 ILLUMINATOR LV-1G 9.25 25.25 ILLUMINATOR LV-4 ELECTRONICS MODULE Base Model BATTERIES (90 Minutes @ Full Load) Power Rating (VA/W) Efficiency (@ full load) Audible Noise (db a @1m Heat Loss (BTU)/HR Number of Batteries Voltage (VDC) Current (amps) Cabinet Dimensions Width in/cm Depth in/cm Height in/cm LV-1 175 92% 45 41 14.25/36.20 6.50/16.51 17.75/45.09 30/13.62 25/11.351 1 12 17 55/24.97 LV1G 175 92% 45 41 23.84/60.55 8/20. 32 7.5/19.05 30/13.62 25/11.351 1 12 17 55/24.97 LV-2 350 96% 45 48 19/48.26 9.25/23.50 22/55.88 50/22.7 50/22.7 2 24 17 100/45.4 LV-3 550 97% 45 56 19/48.26 9.25/23.50 22/55.88 55/24.97 75/34.053 3 36 17 130/59.02 LV-4 750 97% 45 64 25.25/64.14 9.25/23.50 22/55.88 80/36.32 100/45.44 4 48 17 180/81.72 Weight lbs/kg 90 Minute Batteries lbs/kg Total System Weight lbs/kg 5

SYSTEM SPECIFICATIONS Input Output Voltage Input Frequency Synchronizing Slew Rate Protection Harmonic Distortion Voltage Static Voltage Dynamic Voltage Harmonic Distortion Overload Output Frequency Load Power Factor Inverter Overload Output Types Protection Crest Factor 120 or 277Vac 1-phase 2-wire +10% -15% 60Hz, +/-3% 1 Hz per second nominal Fuse < 10% (For Resistive Load) 120 or 277Vac 1-phase 2-wire Load current change +/- 2%, battery discharge +/- 12.5% +/- 10% for load step change, recovery within 5 cycles < 3% THD for linear load Circuit Breaker protected (Optional) 60Hz +/-.05 Hz during emergency mode.5 lag to.5 lead 250% for 16 Cycles, 110% continuously Normally On, Normally Off or Switched Optional Distribution Circuit Breaker(s) (350, 550 and 750W) 3.5 Battery Type Charger Protection Disconnect Valve-regulated sealed lead-calcium Microcontroller, 3-stage charger (recharge per UL-924 Specifications) Automatic low battery disconnect; automatic restart upon utility return Fuse Environmental General Altitude Operating Temperature Storage Temperature Relative Humidity Design Generator Input Indicator Lights & Switch Optional Control Panel Optional Metering Standard Alarms Optional Alarms Alarm Contacts Warranty Optional Warranties < 10,000 feel (above sea level) without derating Inverter: 0 to 40 C (32 to 104 F) Battery: 20 to 30 C (68 to 86 F) per UL-924-20 to 70 C (-40 to 158 F) (electronics only) < 95% (non-condensing) Line interactive PWM inverter type utilizing MOSFET technology with 2mS transfer time Compatible with generators. (25KVA or larger) Charging. Ready, Inverter and Test switch OLED display with key pad controls/functions & scrolling system status Input & Output Voltage, Battery Voltage, Battery & Output Current, Output VA, Input Current, Inverter Wattage Ambient/Battery/Heatsink Temperature, Input Frequency, UPS Time & Events, Days of Operation Monthly Test Fault, Yearly Test fault, Charger Fault, Load Reduction Fault, Output Voltage Low, Output Voltage High, Overload Fault, Low Voltage Disconnect, Heatsink Overtemp and Input Fuse Failure Input Frequency Low, Input Frequency High, Input Voltage Low, Input Voltage High, Output Voltage Low, Output Voltage High, Battery Voltage Low, Battery Voltage High, Battery Temp Low, Battery Temp High, Ambient Temp Low, Ambient Temp High and On Iinverter Timer Summary Fault Form C 3 year standard warranty includes all parts; 10 years prorated warranty on batteries Extended warranties, Preventative Maintenance and/or Customized Service Plans. Physical Cabinet Cooling Cable Entry Access Wall Mount; Recess or T-Grid available only on 175W system Convection Cooled Top or Side Front 6

Illuminator Series E/IE Single Phase 1.5KVA to 16.7KVA Illuminator Series CIII Three Phase 4.8KVA to 50KVA Illuminator Series EM Single Phase 1KVA to 2.8KVA Illuminator Series CR/DR Single and Three Phase Outdoor System 3KVA to 8KVA 44 South Commerce Way Bethlehem, PA 18017 Tel: (800) 526-5088 Fax: (610) 868-8686 www.myerspowerproducts.com 03-23-2016