FR-3S Fire Resistant Cables

Similar documents
LSZH Fire Resistant Cables

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

BS EN Natural. (Orange for Non-sheathed) (Red & Black) or (Brown & Blue) (Red, Yellow, Blue) or (Brown, Black, Grey)

is the UK subsidary of Tele-Fonika Kable S.A., with offices and a warehouse centrally located in Leicestershire.

Building & Infrastructure Cables DELIVERING ENERGY

Power & Control Cable IEC

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

Power & Control Cable IEC

Power & Control Cable IEC

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

Materials Evolved* BS EN BS EN IEC IEC (Upon customer request) (Red, Black) or (Brown, Blue)

BS 6724 Armoured Power Cables, 600/1000V

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

600/1000V, PVC Insulated Cables according to IEC

Power & Control Cables. U o. /U 0.6/1 kv - IEC

N2XY IEC XLPE PVC 0.6/1kV Cable

flame Retardant overall screened Instrumentation cables (Multicore)

The cables you need when you need them

Flame Retardant Individual and Overall Screened, Armoured Instrumentation Cables (Multipair)

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

BS6724 SWA/LSZH Cable IEC /1000V

NA2XSEKRY 3 x (25-300) mm² 3.6/6 kv

3. Fire Resistant Cables

NA2XSEKY 3 x (25-300) mm² 3.6/6 kv

o o blue-brown Fire Performance BS EN BS EN

Power & Control Cables

FlexFlame BFOU(i) 150/250(300)V S3/S7 Instr. cable

N2XSEBY 3 x (25-300) mm² 3.6/6 kv

SY Type Control Cable 0.5mm 2 to 120mm 2 PVC Sheath

Pyrohalon. Cables, halogen-free, fire-retardant. Pyrohalon PLUS Fire-resistant cables, halogen-free, fire-retardant

LOW VOLTAGE c a b l e s

NA2XSEY 3 x (25-300) mm 2 3.6/6 kv

RE-T2X(st)H SWAH - BS EN Mica XLPE / LSZH / CAM / SWA / LSZH Cable

600/1000V, XLPE Insulated Cables according to IEC

FlexFlame BFOU-XFR(i) 150/250(300)V Instr. cable. Standards applied. IEC EN 50200:2006 Annex E

Any inquiries, please feel free to contact or Caledonian

Unarmoured Single-Core Cables to BS6883

N2XSERY 3 x (25-300) mm² 3.6/6 kv

Firetec BS 7846 LPCB BASEC Approved Power Cable

POLYCAB WIRES PVT. LTD.

THERMOCOUPLE CABLE. Compensating & Extension Make Up: Solid or stranded conductor Conductor of required thermocouple type Iron constantan Jx

INTRODUCTION NUHAS OMAN QUALITY & RELIABILITY.

FlexFlame RFOU(i) 150/250(300)V S1/S5 Instr. cable

POLYCAB WIRES PVT. LTD.

0.6/1KV FLAME RETARDANT ARMORED & SHEATHED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR

Telephone Cables Fire Warning Cables

Standardization IEC /-351/-353. Conductor material

POLYCAB WIRES PVT. LTD.

CiMEC Technologies Pvt. Ltd., 23/H, Meldi Estate, Gota, Ahmedabad, Gujarat. Discipline Electrical Testing Issue Date

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD.

POLYCAB WIRES PVT. LTD.

0.6/1KV FLAME RETARDANT UNARMORED CABLE PRODUCT CONSTRUCTION 1. CONDUCTOR CROSS-LINKED POLYETHYLENE (XLPE) IEEE 1580 COLOR CODE 3.

List of Malaysian Standard (MS) for Cables. Prepared by MCMA SWO. Cable - Armoured. Cable - Armoured

cmi XLPE Cables PRODUCT CATALOGUE Electric Wire & Cables Complies to AS/NZ Standard cmi XLPE Cables

TRATOS OIL&GAS NEK606

THERMOCOUPLE CABLES THERMOELECTRICITY

POLYCAB WIRES PVT. LTD.

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING CABLES FOR RAILWAY TECHNOLOGY. den-belitsky / Fotolia

LDC Pricelist. ( WEF 1st August 2017 ) "POLYCAB" 4 Pair Unshielded Twisted Pair (UTP) LAN (Computer) Cables. Unarmoured.

HAVELLS INDIA LIMITED Corp. Office : QRG Towers, 2 D, Sector 126, Noida (UP), Ph : E Mail :

BS 6724 Copper Conductor Multi Core SWA LSZH BASEC 0.6/1kV Cable

Electronic Instrumentation

Price List "NATIONAL" PVC FLEXIBLE CABLES COPPER CONDUCTOR 1.1 KV CONFORMING TO IS:694/2010. Size Twin Two Three Four

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

INDUSTRIAL SOLUTIONS MARINE CATALOGUE INNOVATIVE CABLE SOLUTIONS MEETING INTERNATIONAL STANDARDS

Technical data sheet LÜTZE SUPERFLEX PLUS M (C) PUR SERVO 0.6/1 kv Supply line for Bosch Rexroth and other systems For highest requirements

AUTHORISED DEALER: CAPITAL CABLES INDIA PVT. LTD A, Bhagirath Palace, Chandni Chowk, Delhi -06

BFOU 0.6/1kV Power Cable

NA2XKR(AL)Y 1 x (16-800) mm² 0.6/1

BS 5467 Copper Conductor Multi Core SWA PVC BASEC 0.6/1kV Cable

Caledonian Fire Resistant Optic Fiber Cables

Company Profile. Caledonian Medium Voltage Cables

Cables for Railway Technology

Catalogue. Index INDUSTRIAL CABLE


POLYCAB WIRES PVT. LTD. PCC LP NO. 2 / Dtd : 1st May Aluminium Armoured

POLYCAB WIRES PVT. LTD. PCC LP NO. 6 / Dtd : 6th January 2018

POLYCAB WIRES PVT. LTD. PCC LP NO. 3 / Dtd : 1st August 2018

Solid PE Insulated & LAP Sheathed Air Core/Jelly Filled Cables to DIN VDE 0816

NYY-J Cable. Dungannon Electrical Wholesale Tel: Page 1 of 10

CONNECTING ENERGY AND INFORMATION TO GLOBAL GROWTH

burning o Red o Black o Blue o Yellow o Brown o Grey Fire Performance BS EN

Wires & Cables. Next is Ready TM. Marine Cables

I N T R O D U C T I O N

Wires that don t catch fire

Installation cable, PVC insulated. Characteristics Properties Unit. Power cables < 1 kv House wiring cable

CONTROL CABLES CABLES FZE.

Data sheet. Connection cable M12 jack straight - free line end 8-pole, X-coded 0.5 m. Illustrations P/N 142M2X20005 EAN

CLEVELAND CABLE LOCATIONS

PRODUCT CATALOGUE Volume 4

High Voltage Copper, Smooth Aluminum Shield/Sheath

POLYCAB WIRES PVT. LTD.

Technical Data Sheet Unshielded (YY) PVC Control Cable

PVC motor cables unshielded

Technical Data Sheet Unshielded (YY) PVC Control Cable

INSTRUMENTATION CABLE

0.6/1kV Al-Cu XLPE Insulated PVC Sheathed Power Cable

Transcription:

FR-3S Fire Resistant Cables APPLICATION This cable is suitable use in fire extinguishing systems to operate sprinklers, control panels, exit lights in high-rise buildings, hotels, hospitals, sub-ways and public facilities. CONSTRUCTION 1. Conductor Plain Annealed, Stranded Circular Non-Compacted or Circular Compacted Copper 2. Fire barrier Mica Tape 3. Insulation LSOH 4. Colour Insulation Single Core - Orange, Red, Yellow, Blue, Black, Green/Yellow Twin Twisted - Red & Black PRODUCT PERFORMANCE Fire Resistant Test IEC 60331 Fire Resistance Characteristics Test SS 299-1 / BS 6387 Category C.W.Z Flame Retardant Test IEC 60332-1 Flame Retardant Test IEC 60332-3 Category A Oxygen Index Test ASTM D 2863 min. 30% Smoke Density Test IEC 61034-1 & 2 Halogen Content Test IEC 60754-1 Corrosivity Test IEC 60754-2 TECHNICAL DATA Adopted Standard BS 7211 Rated Voltage 450 / 750V or 600/1000V Testing Voltage 2.5KV / 15min Max. Conductor Operating Temperature 90 O C FR-3S, Single Core FR-3S, Twin Twisted Number of Cores Nominal Area of Conductor Overall Diameter No. mm² mm Kg / Km 1.0 rm 3.1 18 1.5 rm 3.5 24 2.5 rm 4.1 36 4 rm 4.6 52 6 rm 5.2 72 10 rm 6.5 119 16 rm 7.6 178 25 cr 9.0 275 35 cr 10.2 370 1 50 cr 11.8 504 70 cr 13.4 706 95 cr 15.8 974 120 cr 17.1 1212 150 cr 18.8 1487 185 cr 21.0 1860 240 rm 25.5 2450 300 rm 28.3 3058 400 rm 31.6 3885 500 rm 35.2 4886 630 rm 39.1 6230 1.0 rm 6.3 40 2 1.5 rm 7.1 50 2.5 rm 8.3 90 rm : Stranded Circular Non-Compacted cr : Stranded Circular Compacted Note: The cables can be produced with anti-termite, UV, oil and / or salt resistant characteristics on special request at higher cost.

FR-100 Fire Resistant Cables APPLICATION This cable is specially designed for area where integrity of electrical circuit is critical to maintain the power supply. Application usage can be found in:- - Emergency lightings, control and power circuits - power stations - Fire alarm systems - underground tunnels - Communication systems - sewage treatment plans - Lifts and escalators - high-rise buildings CONSTRUCTION 1. Conductor Plain Annealed, Stranded Circular Non-Compacted Copper 2. Fire Barrier Mica Tape 3. Insulation PE 4. Sheath LSOH 5. Earth Conductor Plain Annealed Stranded Circular Non-Compacted Copper, if required 6. Colour Insulation 1C Natural 2C Red & Black 3C Red, Yellow & Blue 4C Red, Yellow, Blue & Black Sheath Orange PRODUCT PERFORMANCE Fire Resistant Test IEC 60331 Fire Resistance Characteristics Test SS 299-1 / BS 6387 Category C.W.Z Flame Retardant Test IEC 60332-1 Oxygen Index Test ASTM D 2863 min. 30% Smoke Density Test IEC 61034-1 & 2 Halogen Content Test IEC 60754-1 Corrosivity Test IEC 60754-2 TECHNICAL DATA Adopted Standard SS 299-1 / BS 6387 Rated Voltage 300 / 500V Testing Voltage 2.0KV / 5min Max. Conductor Operating Temperature 70 O C Without Earth Conductor With Earth Conductor Number of Cores Nominal Area of Conductor Overall Diameter Earth Conductor Overall Diameter No. mm² mm Kg / Km No. / mm mm Kg / Km 1.0 rm 3.9 22 - - - 1 1.5 rm 4.2 26 - - - 2.5 rm 4.6 38 - - - 4 rm 5.2 55 - - - 1.0 rm 6.7 58 7/0.43 7.1 70 1.5 rm 7.2 70 7/0.53 7.7 80 2 2.5 rm 8.1 100 7/0.67 8.7 120 4 rm 9.2 140 7/0.85 9.8 170 1.0 rm 7.1 74 7/0.43 7.8 80 1.5 rm 7.7 92 7/0.53 8.5 102 3 2.5 rm 8.7 125 7/0.67 9.4 145 4 rm 9.8 180 7/0.85 10.9 215 1.0 rm 7.8 90 7/0.43 8.6 100 1.5 rm 8.5 104 7/0.53 9.4 118 4 2.5 rm 9.6 155 7/0.67 10.6 185 4 rm 10.9 255 7/0.85 12.0 270 rm Stranded Circular Non-Compacted SS = Singapore Standard Note: The cables can be produced with anti-termite, UV, oil and / or salt resistant characteristics on special request at higher cost.

FR-200 / FR-300 Fire Resistant Cables APPLICATION This cable is specially designed for area where integrity of electrical circuit is critical to maintain the power supply. Application usage can be found in:- - Emergency lightings, control and power circuits - power stations - airports - Fire alarm systems - underground tunnels - hotels - Communication systems - sewage treatment plans - hospitals - Lifts and escalators - high-rise buildings - petrochemical plants CONSTRUCTION 1. Conductor Plain Annealed, Stranded Circular Non-Compacted or Circular Compacted Copper 2. Fire Barrier Mica Tape 3. Insulation XLPE (FR-200) / LSOH (FR-300) 4. Sheath LSOH 5. Colour Insulation 1C Natural 2C Red & Black Sheath Orange 4C Red, Yellow, Blue & 5C & above With number printed on cores PRODUCT PERFORMANCE Fire Resistant Test IEC 60331 Fire Resistance Characteristics Test SS 299-1 / BS 6387 Category C.W.Z Flame Retardant Test IEC 60332 1 Flame Retardant Test IEC 60332-3 Category A Oxygen Index Test ASTM D 2863 min. 30% Smoke Density Test IEC 61034-1 & 2 Halogen Content Test IEC 60754-1 Corrosivity Test IEC 60754-2 TECHNICAL DATA Adopted Standard IEC 60502-1 Rated Voltage 600 / 1000V Testing Voltage 3.5 KV / 5min Max. Conductor Operating Temperature 90 O C Number of Cores Nominal Area of Conductor Overall Diameter No. mm² mm Kg / Km 1.5 rm 6.3 53 2.5 rm 6.7 64 4 rm 7.3 82 6 rm 7.8 106 10 rm 8.8 152 16 rm 9.8 216 25 cr 11.2 315 35 cr 12.4 416 50 cr 14.6 600 70 cr 16.7 820 1 95 cr 18.7 1095 120 cr 20.5 1350 150 cr 22.3 1640 185 cr 24.6 2035 240 rm 29.0 2650 300 rm 31.6 3260 400 rm 35.4 4130 500 rm 39.1 5180 630 rm 43.8 6600 800 rm 48.8 8320 1000 rm 53.9 10380 rm : Stranded Circular Non-Compacted cr : Stranded Circular Compacted Note: 1. FR-200 approx. weights are tabulated in the table. For FR-300, add 2.5 4.5% more to the approx. weight. 2. The cables can be produced with anti-termite, UV, oil and / or salt resistant characteristics on special request at higher cost.

FR-200 / FR- 300 Fire Resistant Cables Number of Cores Nominal Area of Conductor Overall Diameter No. mm² mm Kg / Km 1.5 rm 11.1 175 2.5 rm 12.0 215 4 rm 13.0 265 6 rm 14.2 330 2 10 rm 16.1 465 16 rm 18.2 545 25 cr 20.9 725 35 cr 23.2 985 50 cr 26.2 1275 70 cr 30.4 1785 1.5 rm 11.6 200 2.5 rm 12.6 245 4 rm 13.7 315 6 rm 15.0 400 10 rm 17.0 590 16 rm 19.3 740 3 25 cr 22.2 1000 35 cr 24.8 1370 50 cr 27.9 1790 70 sm 28.5 2420 95 sm 32.1 3240 120 sm 36.0 4040 150 sm 40.4 4930 185 sm 44.5 6380 240 sm 50.0 7930 300 sm 53.2 9800 1.5 rm 12.5 234 2.5 rm 13.6 290 4 rm 14.8 375 6 rm 16.3 485 10 rm 18.6 725 16 rm 21.0 950 25 cr 24.4 1300 35 cr 27.1 1760 4 50 cr 31.0 2340 70 sm 33.3 3190 95 sm 38.7 4290 120 sm 43.1 5350 150 sm 46.5 6490 185 sm 52.9 8090 240 sm 61.0 10530 300 sm 65.2 13010 5 13.6 274 7 14.6 335 10 16.9 446 12 1.5 rm 18.1 512 19 21.6 730 27 25.1 980 37 28.8 1275 5 14.8 345 7 16.0 425 10 18.6 575 12 2.5 rm 20.0 665 19 24.0 965 27 27.8 1297 37 31.8 1710 5 16.1 445 7 17.6 565 10 20.4 770 4 rm 12 22.0 890 19 26.5 1305 27 31.0 1755 rm : Stranded Circular Non-Compacted cr : Stranded Circular Compacted sm : Stranded Shaped Note: 1. FR-200 approx. weights are tabulated in the table. For FR-300, add 3.0 5.0% for 2 4C and 6.0 9% for 5C & above to the approx. weight. 2. The cables can be produced with anti-termite, UV, oil and / or salt resistant characteristics on special request at higher cost.

FR-200A / FR-300A Fire Resistant Cables APPLICATION This cable is specially designed for area where integrity of electrical circuit is critical to maintain the main power supplies. It is used in power stations, mass transit underground passenger systems, airport, petrochemical plants, hotel, hospitals and highrise buildings. CONSTRUCTION 1. Conductor Plain Annealed, Stranded Circular Non-Compacted or Circular Compacted Copper 2. Fire Barrier Mica Tape 3. Insulation XLPE (FR-200A) / LSOH (FR-300A) 4. Bedding LSOH 5. Armour Galvanised Round Steel Wires* 6. Sheath LSOH 7. Colour Insulation 1C Natural 2C Red & Black Sheath Orange 4C Red, Yellow, Blue & 5C & above With number printed on cores PRODUCT PERFORMANCE Fire Resistant Test IEC 60331 Fire Resistance Characteristics Test SS 299-1 / BS 6387 Category C.W.Z Flame Retardant Test IEC 60332-1 Flame Retardant Test IEC 60332-3 Category A Oxygen Index Test ASTM D 2863 min. 30% Smoke Density Test IEC 61034-1 & 2 Halogen Content Test IEC 60754-1 Corrosivity Test IEC 60754-2 TECHNICAL DATA Adopted Standard BS 7846 / BS 6724 Rated Voltage 600 / 1000V Testing Voltage 3.5 KV / 5min Max. Conductor Operating Temperature 90 O C Number of Cores Nominal Area of Conductor Overall Diameter No. mm² mm Kg / Km 50 cr 18.6 805 70 cr 21.2 1105 95 cr 23.2 1400 120 cr 24.6 1687 150 cr 27.5 2080 1* 185 cr 29.9 2530 240 rm 34.3 3210 300 rm 36.9 3890 400 rm 41.3 4970 500 rm 45.6 6080 630 rm 50.2 7620 800 rm 56.6 9720 1000 rm 62.0 11960 rm : Stranded Circular Non-Compacted cr : Stranded Circular Compacted sm : Stranded Shaped Note: 1. * Single core is aluminium wires armoured. All dimensions of the cables are generally according to BS 6724. 2. The cables can be produced with anti-termite, UV, oil and / or salt resistant characteristics on special request at higher cost.

Number of Cores FR-200A / FR-300A Fire Resistant Cables Nominal Area of Conductor Overall Diameter No. mm² mm Kg / Km 1.5 rm 14.0 385 2.5 rm 15.2 445 4 rm 15.9 525 6 rm 17.0 620 2 10 rm 19.2 725 16 rm 22.2 1090 25 cr 24.9 1375 35 cr 28.1 1830 50 cr 31.9 2300 70 cr 36.0 2995 1.5 rm 14.5 420 2.5 rm 16.0 495 4 rm 16.6 600 6 rm 18.0 785 10 rm 21.0 1030 16 rm 23.5 1340 25 cr 27.5 1900 3 35 cr 30.3 2320 50 cr 33.5 2880 70 sm 32.2 2520 95 sm 39.2 4800 120 sm 42.9 5690 150 sm 48.3 7260 185 sm 52.7 8970 240 sm 58.1 10800 300 sm 61.6 12950 1.5 rm 15.4 475 2.5 rm 16.8 570 4 rm 17.8 685 6 rm 20.5 940 10 rm 22.5 1220 16 rm 25.5 1420 25 cr 29.8 2290 4 35 cr 32.7 2810 50 cr 36.6 3530 70 sm 40.2 4780 95 sm 45.6 6140 120 sm 51.2 7860 150 sm 54.6 9200 185 sm 61.2 11130 240 sm 68.5 13940 300 sm 72.0 16540 5 16.4 530 7 17.4 615 10 20.5 890 12 1.5 rm 21.8 985 19 25.4 1310 27 30.0 1865 37 33.6 2275 5 18.0 640 7 19.2 700 10 22.7 1100 12 2.5 rm 24.0 1250 19 29.5 1800 27 33.8 2380 37 37.5 2910 5 19.9 855 7 21.3 1160 10 24.8 1400 4 rm 12 27.0 1715 19 31.8 2320 27 36.8 2965 rm : Stranded Circular Non-Compacted cr : Stranded Circular Compacted sm : Stranded Shaped Note: 1. FR-200A approx. weights are tabulated in the table. For FR-300A, add 1.5 2.5% for 1 4C and 3.0 5.0% above to the approx. weight. 2. The cables can be produced with anti-termite, UV, oil and / or salt resistant characteristics on special request at higher cost.

FRIC-300 / FRIC-300A / FRIM-300 / FRIM-300A Fire Resistant Instrumentation Cables APPLICATION This cable is suitable for control, instrumentation and telecommunication in the power stations, mass transit underground passenger systems, airport, hotels, hospitals, high-rise buildings. CONSTRUCTION 1. Conductor Plain Annealed, Stranded Circular Non-Compacted Copper 2. Fire Barrier Mica Tape 3. Insulation XLPE 4. Collective Screen Aluminum Mylar Foil with Drain Wire 5. Bedding LSOH 6. Armour Galvanised Round Steel Wires 7. Sheath LSOH 8. Colour Insulation Each Pair Black and white cores with pair number printed on the cores 1 Triple White, Black and Red insulation with numbers printed on cores Each Core Black or white cores with number printed on the cores Sheath Orange PRODUCT PERFORMANCE Fire Resistant Test IEC 60331 Fire Resistance Characteristics Test SS 299-1 / BS 6387 Category C.W.Z Flame Retardant Test IEC 60332-1 Flame Retardant Test IEC 60332-3 Category A Oxygen Index Test ASTM D 2863 min. 30% Smoke Density Test IEC 61034-1 & 2 Halogen Content Test IEC 60754-1 Corrosivity Test IEC 60754-2 FRIC-300, FRIM-300 TECHNICAL DATA Adopted Standard BS 5308-2 Rated Voltage 300 / 500V Testing Voltage 1.0 KV / 1 min Max. Conductor Operating Temperature 70 O C FRIC-300A, FRIM-300A No. of Core & Nominal Area of Conductor Overall Diameter FRIC-300 FRIC-300A No. of Core FRIM-300 FRIM-300A & Nominal Area Overall of Conductor Overall Overall Diameter Diameter Diameter No. X mm 2 mm Kg / km mm Kg / km No. X mm 2 mm Kg / km mm Kg / km 1 X 2 X 1.0 8.3 90 13.2 330 2 X 1.0 8.5 80 13.4 350 1 X 3 X 1.0 8.9 100 13.9 360 3 X 1.0 9.1 100 14.0 390 1 X 4 X 1.0 9.8 140 14.7 420 4 X 1.0 10.0 130 14.9 440 4 X 2 X 1.0 16.6 270 22.8 930 6 X 1.0 12.5 190 17.7 580 6 X 2 X 1.0 20.1 360 26.2 1130 10 X 1.0 14.7 290 20.8 760 8 X 2 X 1.0 22.0 460 28.8 1440 12 X 1.0 15.8 355 21.9 900 10 X 2 X 1.0 24.1 550 31.2 1620 19 X 1.0 19.2 500 25.5 1100 1 X 2 X 1.5 9.2 110 14.1 380 2 X 1.5 9.3 110 14.2 420 1 X 3 X 1.5 9.8 130 14.8 420 3 X 1.5 9.8 140 14.7 460 1 X 4 X 1.5 10.8 168 15.7 500 4 X 1.5 10.9 180 15.8 560 4 X 2 X 1.5 19.0 350 25.1 1110 6 X 1.5 13.4 270 18.6 710 6 X 2 X 1.5 23.7 460 30.8 1370 10 X 1.5 15.8 400 21.9 1080 8 X 2 X 1.5 25.5 590 32.8 1700 12 X 1.5 17.0 480 23.1 1200 10 X 2 X 1.5 28.4 750 35.9 2000 19 X 1.5 20.7 710 27.7 1760 1 X 2 X 2.5 10.5 140 15.4 430 2 X 2.5 10.6 140 15.5 460 1 X 3 X 2.5 11.4 180 16.4 510 3 X 2.5 11.2 180 16.1 520 1 X 4 X 2.5 12.5 240 17.7 600 4 X 2.5 12.7 230 17.9 630 4 X 2 X 2.5 21.5 470 27.8 1310 6 X 2.5 15.2 330 21.3 940 6 X 2 X 2.5 26.8 680 33.4 1860 10 X 2.5 18.0 510 24.3 1340 8 X 2 X 2.5 29.5 880 36.3 2180 12 X 2.5 19.4 600 25.7 1520 10 X 2 X 2.5 32.9 1100 41.4 2840 19 X 2.5 23.8 910 31.3 2080 Note: The cables can be produced with anti-termite, UV, oil and / or salt resistant characteristics on special request at higher cost.