Gladiator. Acoustic Switch & Auto Spray Cleaner. Data Sheet. A Higher Level of Performance. Non-contact Self Cleaning Blocked Chute Detection

Similar documents
A Higher Level of Performance. Data Sheet. Microwave Switch Series. Auto Spray Cleaner. For more information, please visit >

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Mobrey MSM400 Ultrasonic sludge density measurement system

QUICKSTART. Quickstart. A higher level of performance

Centurion. Guided Radar. User Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. CGR Series.

Lower maintenance costs: with no moving parts, there is nothing on the DFX to wear down. Wide measuring range: 0.15 to 30 FPS (0.05 to 9 MPS).

CAPACITIVE LEVEL SWITCHES. Capacitive switch catalogue HYC-CSC01 Elect. Iss. 01

Turbidity and Suspended Solids Transmitter

NIVOCONT R VIBRATING ROD LEVEL SWITCHES

The Mobrey product range provides reliable point level detection in a variety of dry solid applications

Electromagnetic Flowmeters. Product Overview.

SKINNER Intrinsically Safe Series Four-Way

A Higher Level of Performance. User Manual. Centurion. Guided Radar. CGR Series. For more information, please visit >

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

ROTARY Point Level Measurement for Inventory Control

ISTEC MAGNETIC METERS

INDUSTRIAL PROCESS SENSORS - FOR SEVERE AND DIFFICULT SERVICES -

Ultrasonic Non Contact Sensors

PROCAP Capacitance Level Sensors

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Pressure Transmitter

Point level measurement Capacitance switches

Level Measurement Continuous level measurement Ultrasonic transmitters

TUNING FORK LEVEL WORKING PRINCIPLE APPLICATION. Solid Level Detection FEATURE. For Liquid: * Water & Solutions * General Purpose Solvent * Petroleum

INSTRUMENTATION & CONTROL

Motion sensors. Milltronics MFA 4p 6/17. Overview

PROCAP Capacitance Level Sensors

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. 4/18 Siemens FI Overview.

Signet 2551 Magmeter Flow Sensor

F-2700 SERIES INSERTION VORTEX FLOW METER

Mobrey dry products level measurement and control

Level Measurement. Point level measurement Capacitance switches. Pointek CLS200 Standard. icenta Controls Ltd

CONTROLLERS & SPECIAL VALVES

MAIN FUNCTION FEATURES. . D = v t /2

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Process Protection Motion sensors

process measurement solutions The dry products level control catalogue

Level Measurement Point level measurement - RF Capacitance switches

Mobrey 003. Ultrasonic Liquid Level Switch. Product Data Sheet February 2015 IP117, Rev DA. Self-contained liquid level alarm.

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

Process Protection Motion sensors

Installation and Operating Manual

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Process Protection Motion sensors

F-2700 SERIES INSERTION VORTEX FLOW METER

Multivariable Vortex Flow Meter

Level Devices. Rotary Level Indicators Roto-Bin-Dicator

Model DFX Doppler ultrasonic flow meter

Level switches Series LC40 Float level switch for liquids

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

F-1500 SERIES INSERTION TURBINE FLOW METER

F-2600 SERIES INLINE VORTEX FLOW METER

Level Measurement. Point level measurement Capacitance switches. Pointek CLS300 Standard. 5/42 Siemens FI Overview.

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

DIAMOND POINT VIBRATING PROBES

Multivariable Vortex Flow Meter

Armstrong In-Line and Insertion Vortex Flow Meters

Masoneilan Series

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

GEMÜ 205 Electrically operated solenoid valve

CVR-625. Compact Vibrating Rod Instruction Manual

Level measurement Guided microwave Product Information VEGAFLEX ma/hart. Level Switching Pressure

Level instruments. Continuous level measurement - Capacitance transmitters SITRANS LC300. 5/262 Siemens FI Overview.

Level Measurement Point level measurement - RF Capacitance switches

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Continuous level measuring system. LevelMax. Selection Guide. Overview 2

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Dissolved Oxygen Measurement System with Air Blast Cleaner

Hydrovar and Packaged Hydrovar

Continuous level measuring system NB 4000 Selection list

Plastic tube variable area flowmeter for liquids and gases

Mobrey 003 Ultrasonic Liquid Level Switch

Part # Features & Applications Specifications Cross Reference

INTERNATIONAL METAL ENGINEERING

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

For reliable control of small, large or multi-system-type lubrication systems

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

Centurion. Guided Radar. User Manual. A Higher Level of Performance. CGR Modbus Interface Series.

RPPN3 - RPPN7 Industrial pressure switch

Sensor boxes SRBE Key features and product range overview

Soliphant T FTM260. Technical Information. Level limit switch Cost-effective vibration limit switch for fine-grained solids

AuCom - Soft Starters

LMC 301 controller. For reliable control of small, large or multi-system-type lubrication systems

OPTIGAS 4010C Technical Datasheet

PRO REMOTE Series CAPACITANCE PROBE

Continuous level measuring system NB 3000 Selection list. Overview

G2 Industrial Grade Meters

RDN4 - RDN8 Differential pressure switch

OPTISWITCH 4000/5000. Vibration level switches for liquids

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Metal tube variable area flowmeter for gases, liquids and steam

User Manual. 1. Introduction

System Electropneumatic Converters (Proportional Valves) Electronic Process Controllers Signal Converters

90 Series - Socket overview for 60 series relays

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

RPPN6 - RPPN8 Industrial pressure switch with high overpressure resistance

Transcription:

A Higher Level of Performance Data Sheet Gladiator Acoustic Switch & Auto Spray Cleaner Non-contact Self Cleaning Blocked Chute Detection For more information, please visit > www.hawkmeasure.com

Overview Acoustic Cleaning Principle of Operation The Gladiator Acoustic Switch uses Acoustic Wave technology in a new Sender / Receiver form for blocked chute detection and anti collision for heavy machinery. The Gladiator Amplifier powers two AW Transducers which use special HAWK developed software where both units pulse and receive each other s Acoustic echoes. When the path between the Transducers is blocked, the units immediately detect the presence / absence change of the return signal and trigger a communications relay for indication or control purposes. The Transducers work both together and independently to detect pulse interference giving twice the application security. HAWK s Acoustic Wave Transducers are self cleaning. The Acoustic Switch is designed for continuous operation in dusty, wet environments where other technologies fail. The power of each pulse (pressure wave) blows the water, moisture and build-up off the face of the diaphragm. Typical Uses Primary Areas of Application Blocked chute detection in wet or dry environments Wet screen blocked chute detection Nucleonic / tilt switch replacement High level alarm / Low level alarm Truck / machine detection (ROM bins, Primary Crusher Dump Pockets) Sewage sludge handling Point level switch. Function The Gladiator Acoustic Switch can be used for blockage detection, barrier detection, machine detection / protection and point level measurement, and detection of objects or material between two points. Brewing Cement Chemical Fertilizer Food & Beverage Glass Mining & Metals Packaging Paper Pharmaceutical Plastics Refining Sugar Water & Wastewater Sewage Sludge Power Generation (coal fired). Features No contact with the product required Self cleaning transducers Heavy duty titanium version available Designed for dusty, wet environments LCD setup / diagnostics on remote amplifier Simple 1-minute setup 2 Relay outputs Adjustable ON and OFF delays Remote 3G connection option & support Remote amplifier to sensor separation up to 500 meters (1640ft). 2

AMP TX1 TX2 Typical Applications CAL RUN Our on-ongoing commitment is to provide Industry Leading Technology and Cost Effective Solutions. Wet Screens Blocked Chute Detection - Water Sprays ROM Bins Blocked Chute Detection - Wet / Dry Product / Truck Detection / Water Sprays 3

AMP TX1 TX2 AMP TX1 TX2 Typical Applications Process Protection - Blocked Chute Bulk Solids Material flow blockage detection Designed for wet & dusty environments Self cleaning Transducers dislodge & prevent build up Heavy duty Titanium version for product impact resistance Apron Feeder Reclaim conveyor blocked Jam protection Slurry Sludge product CAL RUN CAL RUN 4

Dimensions Remote Amplifier 111.5 mm (4.4 ) 192.5 mm (7.6 ) 174 mm (6.9 ) 78 mm (3.1 ) 14 mm (0.6 ) 30.7 mm (1.2 ) 7.5 mm (0.3 ) 192.5 mm (7.6 ) 147 mm (5.8 ) 108 mm (4.3 ) 190 mm (7.5 ) 107 mm (4.2 ) 190 mm (7.5 ) 167.5 mm (6.6 ) 141.5 mm (5.6 ) 131.5 mm (5.2 ) 16.2 30.0 33.0 29.0 29.0 33.0 20.2 182.5 mm (7.2 ) 50 mm (2 ) 74 mm (2.9 ) 4 mm (0.2 ) 147 mm (5.8 ) 158 mm (6.2 ) 182.5 mm (7.2 ) Remote Transducer With GAWSLV-3-X and FA4A-4 Flange Remote Transducer with Spray Cleaner With FA4A-4-ASC Flange Sensor face threaded to end of steel thread (10mm cavity) 240mm (9.4 ) 350mm 13.8 Flange Spray Sleeve ISOVIEW FOR REFERENCE ONLY 35mm (1.4 ) max. 165mm (6.5 ) min. 95mm (3.7 ) 123mm (4.8 ) 3 x O-rings 100mm (3.9 ) 100mm (3.9 ) 102mm (4.0 ) Mounting Flange STANDARD 4 ANSI FLANGE DIMENSIONS SIZE 4 FLANGE A (PCD) B (OD) TYPE mm in. mm in. C (Hole) mm in. FA4 190.5 7.5 228 9.0 19 0.75 No. Holes 8 A B C 5

Dimensions / Mounting Overview AWRT-JB Junction Box 150mm (5.9 ) 60mm (2.4 ) AMP TX1 TX2 87mm (3.4 ) 4x4mm Bottom Top 170mm (6.7 ) 80mm (3.1 ) 3 x M20 x 1.5 or 3/4 NPT adaptor Typical Mounting With GAWSLV-3-X UHMW sleeve and FA4A-4 Flange With Spray Cleaner and FA4A-4-ASC Flange ID 100-102mm (3.9-4 ) Pipe with 4 ANSI interface ID 100-102mm (3.9-4 ) Pipe with 4 ANSI interface 3 x O-rings 100mm (3.9 ) 102mm (4.0 ) 100mm (3.9 ) 102mm (4.0 ) min. 95mm (3.7 ) max. 165mm (6.5 ) Adjustable Flange Range Flange 123mm (4.8 ) Minimum Range 400mm (15.8 ) 6

System Information / Wiring Hawk AWRT-JB Junction Box Dimensions System Components Open 150mm (5.9 ) Closed (side) 60mm (2.4 ) AMP TX1 TX2 87mm (3.4 ) Amplifier Junction Box Bottom 4x4mm Acoustic Switch 15kHz Remote Transducers with UHMW sleeve and Flange Top 170mm (6.7 ) CAL 80mm (3.1 ) RUN 3 x M20 x 1.5 or 3/4 NPT adaptor or Acoustic Switch 15kHz Remote Transducers with Spray Sleeve and Flange Gladiator Remote Amplifier Wiring Solenoid wiring for Spray Cleaner SLAVE IN MASTER OUT TEST IN RELAY 1 NC COM NO RELAY 2 NC COM NO RELAY 2 NC COM NO 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 RELAY 1 RELAY 2 SLAVE IN MASTER OUT TEST IN NC COM NO NC COM NO 28 29 30 +24V SOLENDOID 1 2 Is 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 + BLACK E B A + N L1 + 13 14 15 N L1 1N4004 Diode 4-20mA (N/A) SENSOR COMMS DC-In AC-In* AC-In* 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Relay 1 - Output Relay Relay 2 - FailSafe Relay + Use long nose pliers to extract terminals + *AC-In is replaced by 36-60VDC with Power Input Option C. Relay 1 - Output Relay Relay 2 - FailSafe Relay AWRT-JB-01 Junction Box Connect colour to colour BLACK E BLACK E BLACK E 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 Is 4-20mA (N/A) BLACK E B A N L1 SENSOR COMMS DC-In AC-In* AMPLIFIER TRANSDUCER 1 TRANSDUCER 2 7

System Overview Overview GAWC-SYS1 Acoustic Cleaner Components D1 A Note: Full cleaner package GAWC-SYS1 includes all converters, reducers, connecters, 30m of 12mm tube, 20m of 6mm tube, solenoid and FA4A-4-ASC flanges. It does not include other eletronics (transducers, amplifier, junction box). A B Part Description Solenoid 0.5 to 4 x 1/4 connecter Part Number GAWC-SL GAWC-4P C1 Hawk Transducer AWRT15 AS* C2 Cleaner Sub-assembly GAWC-X B D1 Ø 12mm tube Supplied in single piece Total length = distance of part A to part B x 2 (one length per transducer) GAWC-12MMLz D2 C 1 BSP INT THD on Solenoid Water connection size determined by end user Detail A D2 Ø 6mm tube Supplied in single piece Total length = distance of part B to part C x 8 (Four equal lengths per transducer) z = Specify length in metres *Consult Acoustic Switch datasheet for full transducer part numbering D1 Ø12mm Tube Detail B GAWC-06MMLz Solenoid Plug Socket D2 Ø6mm Tube Detail C C1 C2 Max. water pressure 14bar (1400kpa) Min. water pressure 1bar (100kpa) Wiring Diagram for Solenoid Plug Socket 1N4004 Diode 1 2 8

System Overview Overview GAWC-SYS2 Acoustic Cleaner Components D1 A Note: Full cleaner package GAWC-SYS2 includes all converters, reducers, connecters, 30m of 12mm tube, 20m of 6mm tube, solenoid and FA4A-4-ASC flanges. It does not include other eletronics (transducers, amplifier, junction box). A Part Description Heavy Duty Burkett Valve & Solenoid Part Number GAWC-SL2 B 0.5 to 4 x 1/4 connecter GAWC-4P C1 Hawk Transducer AWRT15 AS C2 Cleaner Sub-assembly GAWC-X B D1 Ø 12mm tube Supplied in single piece Total length = distance of part A to part B x 2 (one length per transducer) GAWC-12MMLz D2 C D2 Ø 6mm tube Supplied in single piece Total length = distance of part B to part C x 8 (Four equal lengths per transducer) z = Specify length in metres GAWC-06MMLz 1 BSP INT THD on Solenoid Water connection size determined by end user Detail A D1 Ø12mm Tube Detail B Solenoid Plug Socket D2 Ø6mm Tube Detail C C1 C2 Max. water pressure 16bar (1600kpa) Min. water pressure 1bar (100kpa) Wiring Diagram for Solenoid Plug Socket 1N4004 Diode 1 2 9

Part Numbering Remote Amplifier Junction Box GSA Remote Gladiator System Amplifier Housing S Standard polycarbonate electronics housing Power Supply B 12-30VDC C 36-60VDC U 12-30VDC and 90-260VAC Output Options S Switch. 1 level relay, 1 failsafe relay, with Modbus Other Options A22 ATEX Grp II Cat 3 GD T85 C IP67 Tamb -40 C to 70 C GSA S U S AWRT-JB-01 AWRT-JB-06 HAWK multi purpose junction box for dual transducer applications HAWK multi purpose junction box for dual transducer applications with 6m cable Extra Cable (Length in metres) CA-TXCC-R- C15 C30 C50 C100 Mounting Flange FA4A-4 FA4A-4-ASC HAWK 4 ANSI flange with decoupled connection flange for acoustic switch sleeve HAWK 4 ANSI flange with decoupled connection flange for spray cleaner sleeve Remote Transducer AWRT Acoustic Wave Remote Transducer 15 15kHz for applications with heavy duty self cleaning requirements Transducer Diaphragm / Sleeve Material T Teflon / UHMW (applications suitable for Teflon (no sensor face wear)) Y Titanium face / UHMW (applications with possible sensor face wear eg crushers) Transducer Housing Material 4 Polypropylene Thread Standards for End cap X Not Available Mounting Thread X 15kHz - GAWSLV-3-X sleeve mounted (3.5 BSP thread to suit FA4A-4 flange) Approval Standard X Not Required A22 ATEX Grp II Cat 3 GD T85 C IP67 Tamb -40 C to 70 C Connection C IP68 Sealed unit with cable Cable Length 15 15m cable (standard) 30 30m cable Accessories X UHMW sleeve Software Options AS Gladiator Acoustic Switch AWRT 15 Y 4 X X X C 15 X AS Hazardous area approvals and intrinsically safe options available, contact your local distributor or head sales office for further information. 10

Part Numbering Overview Cleaning System (GAWC-SYS1) GAWC-SYS1 cleaner package consists of GAWC-X GAWC-SL GAWC-4P GAWC-12MML Z GAWC-06MML Z Cleaning System (GAWC-SYS2) GAWC-SYS2 cleaner package consists of GAWC-X GAWC-SL2 GAWC-4P GAWC-12MML Z GAWC-06MML Z Cleaning System Mounting Flange FA4A-4-ASC Z = specify pipe length in metres See GAWC-SYS1 or 2 Acoustic Cleaner Components for length requirements Water Pressure Minimum: 1bar (100kpa) Maximum: 14bar (1400kpa) (GAWC-SYS1 with Festo valve) Maximum: 16bar (1600kpa) (GAWC-SYS2 with Burkett valve). Water Quality System requires good water quality. Install filter if required. Water Usage Approximately 200ml per second per transducer (water pressure dependent). Solenoid coil MD-2-24VDC-PC - #549903 Feature Values Assembly position Any Switching position indicator No Duty cycle 100% Characteristic coil data 24V DC: 6,8W Permissible voltage fluctuation +/- 10% Protection class IP65 Ambient temperature -20...50 o C Max. tightening torque for fitting 0.5 Nm Product weight 110 g Electrical connection Per DIN EN 175301-803 Mounting type With knurled nut Material information, solenoid coil Duroplast Copper Steel Material information, coil Copper 11

Specifications Operating Voltage 12-30VDC (residual ripple no greater than 100mV) 90-260VAC 36-60VDC. Power Consumption <0.8W @ 24VDC <6W @ 48VDC <5VA @ 240VAC <3VA @ 115VAC. Communications GosHawk, Modbus Multidrop mode can address 1-250 units over 4 wires. Relay Outputs: (2) Remote Transducer to Amplifier Separation Up to 500m (1640ft) using specified extension cable (Belden 3084A). Maximum Operating Pressure 2 BAR. Display 2 line x 12 character alphanumeric LCD Backlight standard. Memory - Remote Non-Volatile (No backup battery required) >10 years data retention. Enclosure Sealing Form C (SPDT) contacts, rated 5A at 240VAC resistive Remote fail-safe test facility for one relay. Operating Temperature Remote Electronics -40 C (-40 F) to 80 C (176 F) Remote Transducers -20 C (-4 F) to 80 C (176 F). Fail-Safe Selectable - presence or absence of material High level fail-safe: Relay is activated when material is present. Low level fail-safe: Relay is activated when no material is present. Maximum Range Blocked Chutes: Maximum: 15m (50ft) Minimum: 400mm (32 ). Hawk Measurement Systems Hawk Measurement (Head Office) 15-17 Maurice Court Nunawading VIC 3131, AUSTRALIA Phone: +61 3 9873 4750 Fax: +61 3 9873 4538 info@hawk.com.au For more information and global representatives: www.hawkmeasure.com Additional product warranty and application guarantees upon request. Technical data subject to change without notice. Remote Electronics IP67 (NEMA 4x) Remote Sensors IP68 Junction Box IP67. Cable Entries Remote Sensors 1 x M20 Gland / 3/4 NPTF threaded adaptor. Remote Amplifier 4 x 20mm (0.8 ), 1 x 16mm (0.6 ) knock outs. Mounting 15kHz Blocked Chute Transducer 4 ANSI flange with decoupled thread piece Remote Amplifier Back mount, DIN rail mount Pipe Specification: 4-00 Z40 ID = 100mm Black Pipe. Typical Weight kg lb 15kHz Transducer 8 17.6 Remote Amplifier 1 2.2 90 Glenn Street Suite 100B, Lawrence, MA 01843, USA Phone: +1 888 HAWKLEVEL (1-888-429-5538) Phone: +1 978 304 3000 Fax: +1 978 304 1462 info@hawkmeasure.com Represented by: DOC-ACOUSTIC+ASC-DAT v2.0 0817 All company or product names are registered trademarks or trademarks of their respective owners.