Polar - Flo Heavy Duty Unit Cooler

Similar documents
Ultra - Temp Heavy Duty Unit Cooler

Medium Profile Unit Cooler

Inter-Temp MEDIUM PROFILE UNIT COOLER

MEDIUM SILHOUETTE UNIT COOLERS AIR AND ELECTRIC DEFROST MODELS

Low Profile Unit Cooler

Unit Cooler. Small to Medium Walk - Ins. Coolers & Freezer Applications

LOW HEIGHT UNIT COOLER

LOW PROFILE UNIT COOLER

Next-Gen All-Temp Low Profile Unit Cooler

Center Mount Unit Coolers

5 to 100 Ton Capacity Custom Capacities Available

CAPACITY BTU/H FAN DATA MOTORS 240V AMPS

INDEX. Page Reach-In Unit Coolers: ASL-Temp 2 Slim-Temp 2 Wedge-Temp 3 Flex-Temp 3 Mullion-Temp 3 T-Temp 4 Twin-Temp 4 Mini-Twin-Temp 4 Wall-Temp 5

High Profile Evaporator

TMP. Medium Profile Evaporator CONTENTS PRODUCT DATA & INSTALLATION

KEP. Extended Profile Evaporator CONTENTS PRODUCT DATA & INSTALLATION

High Profile Evaporator

THINK COLD. THINK LARKIN. WAREHOUSE/INDUSTRIAL UNIT COOLER

Low Profile Unit Coolers

MEDIUM PROFILE UNIT COOLERS Technical Guide

MAKING REFRIGERATION GREENER

Medium Profile Unit Coolers

TOTALINE REFRIGERATION CONDENSERS

MEDIUM PROFILE UNIT COOLERS Technical Guide. Models HMA Air Defrost HME/HML Electric Defrost HMG/HMF Hot Gas Defrost.

LUI / LUO. Condensing Units

GENERAL ELECTRIC CONCEALED CHILLED WATER FAN COIL UNITS

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

RCD Air Cooled Condensing Unit (50/60 Hz)

Eclipse 2000 Service Parts

HEATING & COOLING COIL PRODUCTS

DCC Commercial. 3- to 6-Ton Packaged Air Conditioner. Cooling Capacity: 34,600 71,000 BTU/h

DSG Commercial. 3-5 Ton Packaged Gas/ Electric Units 14 SEER / up to 12.0 EER Up to 81% Efficient

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

Large Profile Unit Coolers

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

CAL / CEL / CDL / CGL / CKL

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

CPH Commercial. 7½- to 12½-Ton Self-Contained. Packaged Heat Pump. Cooling / Heating Capacities: up to 11.5 EER up to 3.5 COP. 90, ,000 BTU/h

SBH / SBV Sales Guide BLOWER-COILS HORIZONTAL AND VERTICAL

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

A Division of Nailor International Inc. ECONOMY AIR HANDLERS

COMMERCIAL WALK-IN COOLERS AND FREEZERS

Efficient solutions for commercial refrigeration

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.

Dual Discharge Evaporator (DX) Freon Applications 1-19 Tons MDN

DSC Commercial. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER. Cooling Capacity: 35,000 58,000 BTU/h

DCG Commercial. 3- to 6-ton Packaged Gas/Electric Units. Cooling Capacity: 34,600 71,000 BTU/h Heating Capacity: 36, ,400 BTU/h

DECORATIVE FAN COIL UNIT DECORATIVE FAN COIL UNIT SPECIFICATIONS

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION FEATURES MODELS: AHX SERIES YTG-A-0409

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

Air-Cooled Fluid Cooler

DZ11TA Commercial. 7 ½ & 10-Ton, Three-Phase Split System Heat Pump 11 EER/ IEER /3.3 COP/R-410A

2017 Price List. Krack Corporation Hussmann Corporation St. Charles Rock Rd. Bridgeton, MO Phone: Fax:

Nomenclature. Table of Contents. BH A 850 C P A Vintage

TECHNICAL GUIDE. COOLING & HEAT PUMP MODELS: F2RP024 THRU Hz SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

Consider The Possibilities...

DCH Commercial. 3- to 6-Ton, Three-Phase Packaged Heat Pumps. Cooling Capacity: 35,000 70,000 BTU/h Heating Capacity: 34,600 70,000 BTU/h

Manufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Product Data. Features/Benefits. 42BH System Fan Coil. 800 to 4000 Cfm

AIR COOLED CHILLERS WATER COOLED CHILLERS

Unit Coolers MUC-LUC. 1 kw 13,7 kw.

Lo-Profile Unit Coolers

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH

COMMITTED TO ENGINEERING INNOVATION

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

HBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR

TECHNICAL GUIDE SINGLE PIECE AIR HANDLERS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS DESCRIPTION MODELS: AHP18 THRU 60 AND SHP48 THRU 60 FEATURES

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Complete HVAC Capability

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH

Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

Air Cooled Condensing Units - Technical Catalog. Featuring CopelandTM Compressors 404A and 507 Refrigerants

TECHNICAL GUIDE SINGLE PIECE VARIABLE SPEED AIR HANDLERS. DESCRIPTION FEATURE

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

Standard features. Optional features

Q5RD Series Single Packaged Heat Pump, Single Phase

PACKAGE HEAT PUMP UNITS

Standard features. Optional features

GSZ13. Energy-Efficient Split System Heat Pump 1½ to 5 Tons. Cooling Capacity: 17,400 to 57,000 BTU/h Heating Capacity: 17,000 to 58,000 BTU/h

HCH6. Product Specifications

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

Q7RE Series Single Packaged Heat Pump, Single Phase

DZ11S Commercial & 10-Ton, Three-Phase

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

Modular Variable Speed Air Handlers

3- to 6-Ton. 13 SEER / up to 11.3 EER & 7.7 HSPF. Packaged Heat Pump. Heating Capacity: 34,600 70,000 BTU/h. Cooling Capacity: 35,000 70,000 BTU/h

PACKAGE GAS ELECTRIC UNITS

NH 3. Evaporator. Ammonia Applications Tons MANP

CUH Series. Cabinet Unit Heaters HEAT TRANSFER DIVISION

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

Q7RE Series Single Packaged Heat Pump, Single Phase

G Series Air Cooled Condensing Units 1/2 to 6 HP Brochure September, 2011

Transcription:

Publication No. WT-PAH-07A Polar - lo Heavy Duty Unit ooler Air Defrost - 6,400 to 7,000 BTUH lectric Defrost -,800 to 48,000 BTUH Hot Gas Defrost -,800 to 48,000 BTUH Large Walk-Ins and Warehouses ooler & reezer Applications

Polar - lo eatures APPLIATINS Polar-lo unit coolers are ideally suited for a wide range of large coolers, freezers and blast freezers. The P*U and P*L models are designed for use below +5 room temperature. The P*M and PAH models are designed for coolers in the medium and high temperature ranges. SIZS There are 6 sizes available, ranging in capacity from,800 to 7,000 BTUH @ 0 TD, and ranging in air flow from,70 to 9,900 M. HUSING ust-free, heavy gauge textured Aluminum; lightweight and durable. Air and electric defrost models have hinged drain pans to allow for convenient servicing and maintenance (Hot Gas drain pans are not hinged). LITING LGS - fan models and larger are shipped upright with removable lifting legs, allowing the unit to be installed quickly, and easily with a forklift. Slotted hangers are provided for fast installation. IL Seamless copper tubes are mechanically expanded into heavy gauge corrugated Aluminum fins to assure maximum heat transfer. Die formed fin collars are provided for accurate fin spacing. Hangers are fastened directly to the tube sheets of the coil to provide high structural strength. All units are dehydrated, sealed and shipped with a nitrogen holding charge. IGANTS or use with direct expansion, -, -404A, -50 and -507. Specify refrigerant when ordering. A separate compartment is provided for all refrigeration connections, allowing ample room for internal mounting of expansion valve(s). Polar-lo can also be used for chilled water or glycol solutions, contact factory for selection. ANS Powerful, heavy-duty Aluminum fans are individually balanced to provide vibration-free operation. Wire fan guards are epoxy coated for corrosion resistance. ptional air straighteners are available for increased air throw. MTS All standard motors are high efficiency PS, ball bearing type, life lubricated and thermally protected. P*U and P*L models use /4 HP, 075 PM or /4 HP, 65 PM motors. P*M and PAH models use / HP or /4 HP, 075 PM motors. lectronically ommutated motors are now available for Polar-lo units. LTIAL Available in 5/, 08/0/, 08/0/, 460/ and 460/ (see page 0). Polar lo s can also be operated on 0//50, 0//50, 80//50, and 80//50 power (contact factory for details). All components are factory wired to convenient screw-type terminal blocks. A large compartment is supplied for all electrical components and is easily accessible by removing the end panel. AI DST Available on PAM and PAH series only for use in coolers at +5 and above. omplete Air Defrost systems are available from WITT. LTI DST Available on all but the PAH models. Placement of the heaters within the refrigeration coil allow for a more efficient and rapid defrost cycle. This arrangement enables heat to be conducted from the center of the core out, for a more even defrost pattern. All heaters are factory wired to screw-type terminal blocks, allowing for a quick field change over from to phase or 0V to 460V and vice versa with the use of jumpers. An adjustable, remote bulb defrost termination and fan delay (DTD) is mounted and wired. Drain pans are heated for fast, reliable drainage. Timer and contactors are available as options, see page. omplete lectric Defrost systems are available from WITT. HT GAS -VAP DST Available on all but the PAH models. Includes an adjustable defrost termination and fan delay (DTD), factory installed. A hot gas drain circuit is supplied, thus eliminating the need for electric heat and additional wiring. A Heat xchanger/e-vaporator is supplied with every unit. efer to the current Technical Bulletin HG for piping. omplete Hot Gas e-vap systems are available from WITT, contact factory. HT GAS VS YL DST Available on all but the PAH models. Includes an adjustable defrost termination and fan delay. (DTD) factory installed. A hot gas drain pan circuit is supplied, thus eliminating the need for electric heat and additional wiring. This unit is also used for Alternating vaporator Systems.

Polar - lo eatures lectric Defrost lectrical ompartment D A. Defrost control (DTD) B. DTD sensing bulb. in heater (typical) D. ield wiring terminal strips. an motor capacitors B A efrigerant onnection ompartment efrigerant nd ompartment (Larger two-circuit Hot Gas coil shown) A. Hot gas supply (from drain pan) B. Hot gas inlet to coil (two-pipe). Hot gas inlet to coil (three-pipe) Hot gas outlet from coil (two-pipe) D. Liquid inlet from TX valve. Suction connection. xternal equalizer line D D B A ptions opper fins. oated fins (air and hot gas models only). Galvanized steel casing. High pressure propeller fans (up to 0.5 external pressure). Inherent phase motors. Ultra low temperature motor grease for applications down to -60 suction temperature. Insulated drain pans. ustom circuiting for chilled water or glycol applications. High air throw fan guards.

4 Polar - lo nergy Savings per Motor by hanging to More fficient Unit ooler Motors (based on nergy ost of $0.0 per kwh) Motor HP and PM Standard PS Motor Input Power Watts/Mtr ptional Motor Input Power Watts/Mtr educed Power onsumption Watts/Mtr un Time Hrs/Day Motor nergy Savings kwh/yr Motor nergy Savings $/Yr educed Box Load MBTU/Yr ond. Unit nergy Savings kwh/yr ond. Unit nergy Savings $/Yr Yearly Savings $/Motor / 075 57 5 060 06,67 695 70 76 0.9 /4 075 850 495 55 85 85 9,76,870 87 47 0.4 /4 65 77 580 7 00 0,754 7 7 8.0 Payback Yrs Yearly Savings per Motor 500.00 Dollars Saved 400.00 00.00 00.00 00.00 0.00 4 5 6 7 8 9 0 Months / HP Motor /4 HP (075) Motor /4 HP (65) Motor Air Throw Air throw is affected by installation variables. ptimum air throw is obtained by high ceiling with no interference from beams, product or return air restrictions. MDL P*U / P*L P*M / PAH WI AN GUAD 60-80 feet 50-70 feet AN GUAD / AI STAIGHTN 80-00 feet 70-90 feet MDL NUMB NMNLATU P U 8 D P Polar-lo Unit oolers A = Air Defrost (M & H) only = lectric Defrost H = Hot Gas e-vap (U, L & M only) G = Hot Gas ev. ycle U = 4 ins/inch (reezer) L = 6 ins/inch (reezer) M = 6 ins/inch (ooler) H = 8 ins/inch (ooler) Number of ans MT TYP P = Permenant Split apacitor = lectronically ommutated VLTAG D A = 5//60 D = 08-0//60 = 08-0//60 = 460//60 G = 460//60 J = 575//60 BTUH in Hundreds

5 Polar - lo MDL NUMB APAITY BTUH @ 0 TD (404A, -) SUTIN TMPATU -0-0 -0 +0 M P*U-8 P*U-6 P*U-55 P*U-474 P*U4-7 P*U4-85 P*U4-080 P*U5-50 P*U6-60 750 7500 800 450 6400 600 600 600 400 800 600 5500 47400 700 8500 08000 5000 6000 400 4700 700 49500 7800 89000 900 4000 76600 900 5700 8700 5600 74500 9800 7700 47000 76600 4000 7900 400 5600 8000 00900 8000 60000 9000 P*L-5 P*L-5 P*L-9 P*L-40 P*L-04 P*L-6 P*L-408 P*L-445 P*L-540 P*L-6 P*L-660 P*L4-7 P*L4-87 P*L4-950 P*L4-00 P*L4-60 P*L4-80 P*L5-575 P*L5-75 P*L6-890 P*L6-070 750 650 550 7600 700 800 800 800 450 50 800 6600 600 500 00 0800 0400 6000 5500 00 00 0900 00 6800 0900 6400 400 5500 8700 47000 500 57400 6700 700 8500 95700 09600 0000 7000 50000 64400 80000 700 400 800 400 8400 800 800 4600 50500 5700 6700 67500 76400 88900 0900 7800 9000 4700 600 76700 9500 500 500 900 4000 0400 600 40800 44500 54000 600 66000 700 8700 95000 0000 6000 8000 57500 7500 89000 07000 500 6400 0800 5900 800 9000 4400 48000 5800 6600 700 78000 8800 0600 8800 6000 49000 70000 8600 04000 500 MDL NUMB APAITY BTUH@0 TD +0 M P*M-64 P*M-09 P*M-70 P*M-9 P*M-90 P*M-44 P*M-58 P*M-66 P*M4-780 P*M4-88 P*M4-00 P*M4-0 P*M4-656 P*M5-065 P*M6-480 90 840 7000 6840 6640 6480 9960 970 80 960 700 00 0400 5500 0600 6400 0900 7000 900 9000 4400 5800 6600 78000 8800 0000 000 65600 06500 48000 MDL NUMB APAITY BTUH@0 TD +5 M PAH-8 PAH- PAH-00 PAH-65 PAH-4 PAH-490 PAH-50 PAH-648 PAH-76 PAH4-866 PAH4-980 PAH4-00 PAH4-45 PAH4-8 PAH5-75 PAH6-70 800 70 6880 6600 6400 650 9800 9600 9400 800 500 00 0700 9900 4900 9900 800 00 0000 6500 400 49000 5000 64800 7600 86600 98000 0000 4500 800 7500 7000 4 Z P I 6 Z P I 6 L P I 8 L P I Performance Data

6 Polar - lo Physical Data 4 I MDL NUMB AN DIA. (In.) QTY MT DATA () HP PM PTINAL HAT XH. -VAP HAT XH. NNTINS (In.) () SUTIN H.G. (UNMTD.) (UNMTD.) DS DS MPT P*U-8 0 /4 65 HX-50 HAA /L -/8 7/8 /4 90 P*U-6 0 /4 65 HX-50 HAA 7/8 DS -/8 7/8 /4 70 P*U-55 4 /4 075 HX-50 HA4A 7/8 DS -5/8 7/8 /4 440 P*U-474 4 /4 075 HX-50 HA5A 7/8 DS -5/8 7/8 /4 570 P*U4-7 4 4 /4 075 HX-500 HA6A 7/8 DS -/8 -/8 -/4 665 P*U4-85 4 4 /4 075 () HX-500 () HA5A () 7/8 DS () -/8 -/8 -/4 875 P*U4-080 4 4 /4 075 () HX-500 () HA5A () 7/8 DS () -/8 -/8 -/4 900 P*U5-50 4 5 /4 075 () HX-500 N/A () 7/8 DS () -/8 -/8 -/4 5 P*U6-60 4 6 /4 075 () HX-500 N/A () -/8 DS () -5/8 -/8 -/4 50 LIQUID DAIN SHIP WT. (LBS) 6 I 6 L P I 6 L P I P*L-5 0 /4 65 HX-50 HAA /L -/8 7/8 /4 80 P*L-5 0 /4 65 HX-50 HAA /L -/8 7/8 /4 00 P*L-9 0 /4 65 HX-50 HAA 5/8 DS -/8 7/8 /4 0 P*L-40 0 /4 65 HX-50 HA4A 7/8 DS -/8 7/8 /4 70 P*L-04 0 /4 65 HX-50 HA4A 7/8 DS -/8 7/8 /4 400 P*L-6 4 /4 075 HX-50 HA4A 7/8 DS -5/8 7/8 /4 45 P*L-408 4 /4 075 HX-50 HA5A 7/8 DS -5/8 7/8 /4 446 P*L-445 4 /4 075 HX-500 HA5A 7/8 DS -/8 7/8 /4 55 P*L-540 4 /4 075 HX-500 HA5A 7/8 DS -/8 7/8 /4 585 P*L-6 4 /4 075 HX-500 HA6A 7/8 DS -/8 7/8 /4 60 P*L-660 4 /4 075 HX-500 HA6A 7/8 DS -/8 7/8 /4 645 P*L4-7 4 4 /4 075 HX-500 HA6A -/8 DS -/8 -/8 -/4 675 P*L4-87 4 4 /4 075 HX-500 () HA5A 7/8 DS -/8 -/8 -/4 76 P*L4-950 4 4 /4 075 HX-500 () HA5A () 7/8 DS () -/8 -/8 -/4 850 P*L4-00 4 4 /4 075 () HX-500 () HA5A () 7/8 DS () -/8 -/8 -/4 885 P*L4-60 4 4 /4 075 () HX-500 () HA6A () 7/8 DS () -/8 -/8 -/4 895 P*L4-80 4 4 /4 075 () HX-500 () HA6A () 7/8 DS () -/8 -/8 -/4 90 P*L5-575 4 5 /4 075 () HX-500 N/A () -/8 DS () -/8 -/8 -/4 0 P*L5-75 4 5 /4 075 () HX-500 N/A () -/8 DS () -/8 -/8 -/4 40 P*L6-890 4 6 /4 075 () HX-500 N/A () -/8 DS () -5/8 -/8 -/4 45 P*L6-070 4 6 /4 075 () HX-500 N/A () -/8 DS () -5/8 -/8 -/4 65 P*M-64 0 / 075 HX-50 HAA /L 7/8 7/8 /4 00 P*M-09 0 / 075 HX-50 HAA 5/8 DS 7/8 7/8 /4 0 P*M-70 0 / 075 HX-50 HA4A 5/8 DS -/8 7/8 /4 60 P*M-9 0 / 075 HX-50 HA4A 5/8 DS -/8 7/8 /4 400 P*M-90 4 / 075 HX-50 HA4A 5/8 DS -/8 7/8 /4 45 P*M-44 4 / 075 HX-50 HA5A 5/8 DS -/8 7/8 /4 446 P*M-58 4 / 075 HX-50 HA5A 5/8 DS -/8 7/8 /4 585 P*M-66 4 / 075 HX-50 HA6A 7/8 DS -/8 7/8 /4 60 P*M4-780 4 4 / 075 HX-50 HA6A 7/8 DS -/8 -/8 -/4 675 P*M4-88 4 4 / 075 HX-500 () HA5A 7/8 DS -/8 -/8 -/4 76 P*M4-00 4 4 /4 075 () HX-50 () HA5A 7/8 DS -5/8 -/8 -/4 80 P*M4-0 4 4 /4 075 () HX-50 () HA5A -/8 DS -5/8 -/8 -/4 885 P*M4-656 4 4 /4 075 () HX-500 () HA6A -/8 DS -/8 -/8 -/4 90 P*M5-065 4 5 /4 075 () HX-500 N/A -5/8 DS -5/8 -/8 -/4 40 P*M6-480 4 6 /4 075 () HX-500 N/A -5/8 DS -5/8 -/8 -/4 65 PAH-8 0 / 075 HX-50 N/A 5/8 DS 7/8 N/A /4 0 PAH- 0 / 075 HX-50 N/A 5/8 DS 7/8 N/A /4 0 PAH-00 0 / 075 HX-50 N/A 5/8 DS -/8 N/A /4 70 PAH-65 0 / 075 HX-50 N/A 5/8 DS -/8 N/A /4 40 PAH-4 4 / 075 HX-50 N/A 5/8 DS -/8 N/A /4 45 PAH-490 4 / 075 HX-50 N/A 5/8 DS -/8 N/A /4 458 PAH-50 4 / 075 HX-50 N/A 7/8 DS -/8 N/A /4 550 PAH-648 4 / 075 HX-50 N/A 7/8 DS -/8 N/A /4 600 PAH-76 4 / 075 HX-50 N/A 7/8 DS -/8 N/A /4 65 PAH4-866 4 4 / 075 HX-50 N/A 7/8 DS -/8 N/A -/4 690 PAH4-980 4 4 / 075 HX-500 N/A 7/8 DS -/8 N/A -/4 746 PAH4-00 4 4 / 075 () HX-50 N/A 7/8 DS -/8 N/A -/4 785 PAH4-45 4 4 /4 075 () HX-50 N/A 7/8 DS -5/8 N/A -/4 905 PAH4-8 4 4 /4 075 () HX-500 N/A 7/8 DS -/8 N/A -/4 90 PAH5-75 4 5 /4 075 () HX-500 N/A -5/8 DS -5/8 N/A -/4 65 PAH6-70 4 6 /4 075 () HX-500 N/A -5/8 DS -5/8 N/A -/4 95 ) All motors are single phase. All three fan models and larger are delta wired for three phase power. Inherent three phase motors are available, contact factory. ) All Polar-lo are custom circuited for optimum peformance and operating efficiency. Should conditions vary from those listed to the right, *connection sizes and quantity may be subject to change, contact factory to confirm. * onnection sizes are based on the following criteria: P*U: - 0 ST, 0 TD -404A P*L: - 0 ST, 0 TD -404A P*M: +0 ST, 0 TD -404A PAH: +5 ST, 0 TD -404A

Dimensions - Air and lectric Defrost Models AI AND LTI DST MDLS P*L-5 P*U-8 P*M-64 PAH-8 P*L-5 P*M-09 PAH- P*L-9 P*L-40 P*U-6 P*M-70 PAH-00 P*L-04 P*M-9 PAH-65 P*L-6 P*U-55 P*M-90 PAH-4 P*L-408 P*M-44 PAH-490 P*L-445 P*U-474 P*M-58 PAH-50 P*L-540 P*M-66 PAH-648 P*L-6 PAH-76 P*L-660 P*L4-7 P*U4-7 P*M4-780 PAH4-866 P*L4-87 P*M4-88 PAH4-980 PAH4-00 P*L4-950 P*U4-85 P*M4-00 PAH4-45 P*L4-00 P*U4-080 P*M4-0 PAH4-8 P*L4-60 P*M4-656 P*L4-80 P*L5-575 P*U5-50 P*M5-065 PAH5-75 P*L5-75 P*L6-890 P*U6-60 P*M6-480 PAH6-70 P*L6-070 QTY HANGS IG. Polar - lo DIMNSINS (In.) A B D -/4 5-/4 46-/8 46-/ 4 -/4 6 76-/8 76-/ 4 4-/ -/4 76-/8 76-/ 5-/4 4 4-/ 06-/8 06-/ 5-/4 5 4-/ -/4 6-/8 6-/ 5-/4 5 4-/ 50-/4 6-/8 6-/ 5-/4 6 4-/ 50-/ 66-/8 66-/ 5-/4 7 4-/ 50-/4 96-/8 96-/ 5-/4 7 igure ) 9-/8 MUNTING DIMNSIN IS NSISTNT N ALL THU 4 ANS MDLS. ) IGATIN NNTINS A N TH AI INLT SID (A) TH UNIT. ) HANG SLTS A ½ x ¼. 4) ALL DIMNSINS A IN INHS. igure ) 9-/8 MUNTING DIMNSIN IS NSISTNT N ALL 4 THU 6 ANS MDLS. ) IGATIN NNTINS A N TH AI INLT SID (A) TH UNIT. ) HANG SLTS A ½ x ¼. 4) ALL DIMNSINS A IN INHS.

8 Polar - lo Dimensions - Hot Gas Defrost Models AI AND LTI DST MDLS P*L-5 P*U-8 P*M-64 P*L-5 P*M-09 P*L-9 P*L-40 P*U-6 P*M-70 P*L-04 P*M-9 P*L-6 P*U-55 P*M-90 P*L-408 P*M-44 P*L-445 P*U-474 P*M-58 P*L-540 P*M-66 P*L-6 P*L-660 P*L4-7 P*U4-7 P*M4-780 P*L4-87 P*M4-88 P*L4-950 P*U4-85 P*M4-00 P*L4-00 P*U4-080 P*M4-0 P*L4-60 P*M4-656 P*L4-80 P*L5-575 P*U5-50 P*M5-065 P*L5-75 P*L6-890 P*U6-60 P*M6-480 P*L6-070 QTY HANGS IG. DIMNSINS (In.) A B D -/4 6-7/8 46-/8 46-/ 4 6-/8 -/4 7-/8 76-/8 76-/ 4 6-/8 4-/ -/8 76-/8 76-/ 5-/4 -/8 4 4-/ -7/8 06-/8 06-/ 5-/4 -/8 5 4-/ 4-/4 6-/8 6-/ 5-/4 -/8 5 4 4-/ 5-/4 6-/8 6-/ 5-/4 50-/8 6 4 4-/ 5-/4 66-/8 66-/ 5-/4 50-/8 7 4 4-/ 5-/4 96-/8 96-/ 5-/4 50-/8 igure ) 9-/8 MUNTING DIMNSIN IS NSISTNT N ALL THU 4 ANS MDLS. ) IGATIN NNTINS A N TH AI INLT SID (A) TH UNIT. ) HANG SLTS A ½ x ¼. 4) ALL DIMNSINS A IN INHS. igure 4 ) 9-/8 MUNTING DIMNSIN IS NSISTNT N ALL 4 THU 6 ANS MDLS. ) IGATIN NNTINS A N TH AI INLT SID (A) TH UNIT. ) HANG SLTS A ½ x ¼. 4) ALL DIMNSINS A IN INHS.

Polar - lo 9 Suction Line Heat xchangers MDL NUMB HX5 HX50 HX75 HX00 HX50 HX50 HX50 HX500 LHX5 LHX0 LHX5 LHX0 APAITY - BTUH (-, -404A) SUTIN TMPATU ( ) -40-0 +0 +5.6 4.5 7.0 9.6 4.0.0 4.4 47. 70. 9.4 08.4 40..4 6.0 9.4.8 8.7 0.6 45.9 6.9 9.5. 44.5 87.0 6.0.9 7.8 4.7 6.6 59.5 90. 0.7 8. 8.0 89.0 48.5 6.8.6. 8. 4.5 69.7 0.0 4. 04.0 7.0 48.5 99.5 DIMNSINS (In) A B -/ -/4-5/8 4-/8 4-/8 4-/4 6-/4 7-/4 9-/ 9-/ 8 8 -/4 -/8-5/8-7/8-5/8-5/8 4-5/8 6-7/8 6-7/8 7-/ 8 NNTINS (DS) (In) LIQUID SUTIN /4 / /8 5/8 /8 7/8 /8 -/8 / -/8 5/8 -/8 5/8-5/8 7/8 -/8 7/8 -/8 -/8 -/8 -/8-5/8 -/8-5/8 WT. (lbs) 4 6 7 5 8 0 igure 5 Suction Line Heat xchanger / Accumulator MDL NUMB HA-A HA-A HA-A HA-4A HA-5A HA-6A APAITY BTUH 6,000,000 4,000 6,000 55,000 80,000 DIMNSINS (In) A B 9-/4 5 5-/4 5 7-/4 5 7-/4 5 45-/8 6 64-/8 6 NNTINS (In.) LIQUID (DS) SUTIN (DS) INLT UTLT INLT UTLT /8 /8 7/8 7/8 / / -/8 -/8 / / -/8 -/8 5/8 5/8-5/8-5/8 5/8 5/8 -/8 -/8 7/8 7/8-5/8-5/8 WT. (lbs) 0 5 0 5 40 50 igure 6

0 Polar - lo lectrical Data - Motors 4 I MDL NUMB PMANNT SPLIT APAIT MTS (PS) TTAL MT AMPS () - 60 Hz TTAL 5 V. 08-0 V. 460 V. MT PH PH PH PH PH WATTS LTNIALLY MMUTATD MTS (M) TTAL MT AMPS () - 60 Hz TTAL 5 V. 08-0 V. 460 V. MT PH PH PH PH PH WATTS P*U-8 4.4.0 77 4.6 580 P*U-6 8.8 4.0 44 9. 60 P*U-55 8.8 4. 700 0.4 990 P*U-474. 7.6.6 550 5.6 9.0 485 P*U4-7 7.6.6 5.6 400 0.8.8 980 P*U4-85 7.6.6 5.6 400 0.8.8 980 P*U4-080 7.6.6 5.6 400 0.8.8 980 P*U5-50.0 5. 7. 450 6.0 5.0 475 P*U6-60 6.4 5. 7. 500. 8.0 970 6 I P*L-5 4.4.0 77 4.6 580 P*L-5 4.4.0 77 4.6 580 P*L-9 4.4.0 77 4.6 580 P*L-40 8.8 4.0 44 9. 60 P*L-04 8.8 4.0 44 9. 60 P*L-6 8.8 4. 700 0.4 990 P*L-408 8.8 4. 700 0.4 990 P*L-445. 7.6.6 550 5.6 9.0 485 P*L-540. 7.6.6 550 5.6 9.0 485 P*L-6. 7.6.6 550 5.6 9.0 485 P*L-660. 7.6.6 550 5.6 9.0 485 P*L4-7 7.6.6 5.6 400 0.8.8 980 P*L4-87 7.6.6 5.6 400 0.8.8 980 P*L4-950 7.6.6 5.6 400 0.8.8 980 P*L4-00 7.6.6 5.6 400 0.8.8 980 P*L4-60 7.6.6 5.6 400 0.8.8 980 P*L4-80 7.6.6 5.6 400 0.8.8 980 P*L5-575.0 5. 7. 450 6.0 5.0 475 P*L5-75.0 5. 7. 450 6.0 5.0 475 P*L6-890 5. 5. 7. 500. 8.0 970 P*L6-070 6.4 5. 7. 500. 8.0 970 6 L P I P*M-64 7... 57.0. 5 P*M-09 7... 57.0. 5 P*M-70 4. 6..6 74 6.0 4. 450 P*M-9 4. 6..6 74 6.0 4. 450 P*M-90 4. 6..6 74 6.0 4. 450 P*M-44 4. 6..6 74 6.0 4. 450 P*M-58. 9. 5.4.9. 07 9.0 6..6 675 P*M-66. 9. 5.4.9. 07 9.0 6..6 675 P*M4-780 8.4.4 8. 5..4 48.0 8.4 5.6 900 P*M4-88 8.4.4 8. 5..4 48.0 8.4 5.6 900 P*M4-00 7..4 0.0 6.6 400 0.8.8 980 P*M4-0 7..4 0.0 6.6 400 0.8.8 980 P*M4-656 7..4 0.0 6.6 400 0.8.8 980 P*M5-065.5 4.9.5 8.7 450 6.0 5.0 475 P*M6-480 5.8 4.9 5.0 8.7 500. 8.0 970 8 L P I PAH-8 7... 57.0. 5 PAH- 7... 57.0. 5 PAH-00 4. 6..6 74 6.0 4. 450 PAH-65 4. 6..6 74 6.0 4. 450 PAH-4 4. 6..6 74 6.0 4. 450 PAH-490 4. 6..6 74 6.0 4. 450 PAH-50. 9. 5.4.9. 07 8.0 6..6 675 PAH-648. 9. 5.4.9. 07 8.0 6..6 675 PAH-76. 9. 5.4.9. 07 8.0 6..6 675 PAH4-866 8.4.4 8. 5..4 48.0 8.4 5.6 900 PAH4-980 8.4.4 8. 5..4 48.0 8.4 5.6 900 PAH4-00 8.4.4 8. 5..4 48.0 8.4 5.6 900 PAH4-45 7..4 0.0 6.6 400 0.8.8 980 PAH4-8 7..4 0.0 6.6 400 0.8.8 980 PAH5-75.5 4.9.5 8.7 450 6.0 5.0 475 PAH6-70 5.8 4.9 5.0 8.7 500. 8.0 970 () All models have single phase motors. Three fan models and larger are delta wired for three phase supply power.

lectrical Data - Heaters 4 I MDL NUMB LTI DST (4) AMPAG ATINGS @ 60 Hz 08 V. 0 V. 460 V. PH PH PH PH PH PH WATTS P*U-8 9.9..0 4.6.0 9.5 5,5 P*U-6 5.5.5 9. 6.0 9.6 7.0 9,8 P*U-55 5.5.5 9. 6.0 9.6 7.0 9,8 P*U-474.8 7.4 8.5 4.5 4,5 P*U4-7 4. 47.8 6.0 8,440 P*U4-85 6.0 67.5.8 7,660 P*U4-080 6.0 67.5.8 7,660 P*U5-50 75. 8.9 4.6 4,575 P*U6-60 89. 98.7 49. 4,490 Polar - lo 6 I P*L-5 9.9..0 4.6.0 9.5 5,5 P*L-5 9.9..0 4.6.0 9.5 5,5 P*L-9 9.9..0 4.6.0 9.5 5,5 P*L-40 5.5.5 9. 6.0 9.6 7.0 9,8 P*L-04 5.5.5 9. 6.0 9.6 7.0 9,8 P*L-6 5.5.5 9. 6.0 9.6 7.0 9,8 P*L-408 5.5.5 9. 6.0 9.6 7.0 9,8 P*L-445.8 7.4 8. 4.5 4,5 P*L-540.8 7.4 8. 4.5 4,5 P*L-6.8 7.4 8. 4.5 4,5 P*L-660.8 7.4 8. 4.5 4,5 P*L4-7 4. 47.8 6.0 8,440 P*L4-87 4. 47.8 6.0 8,440 P*L4-950 6.0 67.5.8 7,660 P*L4-00 6.0 67.5.8 7,660 P*L4-60 6.0 67.5.8 7,660 P*L4-80 6.0 67.5.8 7,660 P*L5-575 75. 8.9 4.6 4,575 P*L5-75 75. 8.9 4.6 4,575 P*L6-890 89. 98. 49. 4,490 P*L6-070 89. 98. 49. 4,490 6 L P I P*M-64 9.9..0 4.6.0 9.5 5,5 P*M-09 9.9..0 4.6.0 9.5 5,5 P*M-70 5.5.5 9. 6.0 9.6 7.0 9,8 P*M-9 5.5.5 9. 6.0 9.6 7.0 9,8 P*M-90 5.5.5 9. 6.0 9.6 7.0 9,8 P*M-44 5.5.5 9. 6.0 9.6 7.0 9,8 P*M-58.8 7.4 4.5 4,5 P*M-66.8 7.4 4.5 4,5 P*M4-780 4. 47.8 4. 8,440 P*M4-88 4. 47.8 4. 8,440 P*M4-00 64. 7..7 7,660 P*M4-0 64. 7..7 7,660 P*M4-656 64. 7..7 7,660 P*M5-065 7. 79.8 9.9 4,575 P*M6-480 86.6 95.7 47.9 4,490 (4) All electric defrost models are standard with heaters wired for three phase unless otherwise specified. See table above to determine models applicable for single phase heater application.

Polar - lo lectrical Defrost Kits 4 I 6 I 6 L P I MDL NUMB P*U-8 P*U-6 P*U-55 P*U-474 P*U4-7 P*U4-85 P*U4-080 P*U5-50 P*U6-60 P*L-5 P*L-5 P*L-9 P*L-40 P*L-04 P*L-6 P*L-408 P*L-445 P*L-540 P*L-6 P*L-660 P*L4-7 P*L4-87 P*L4-950 P*L4-00 P*L4-60 P*L4-80 P*L5-575 P*L5-75 P*L6-890 P*L6-070 P*M-64 P*M-09 P*M-70 P*M-9 P*M-90 P*M-44 P*M-58 P*M-66 P*M4-780 P*M4-88 P*M4-00 P*M4-0 P*M4-656 P*M5-065 P*M6-480 VAPAT 0/ 460/ D- D- D- D-4 D-4 D-6 D-6 D-6 () D- D- D- D- D- D- D- D- 4 D- 4 D-4 D-4 D-4 D-4 D-6 D-6 D-6 D-6 D-6 D-6 () () D- D- D- D- D- D- D-4 D-4 D-4 D-4 D-6 D-6 D-6 D-6 () lectrical Defrost Kit omponents MDL NUMB D-0 D- D- D- D-4 D-5 D-6 D-0 D- D- D- D-5 D-7 D-8 D-0 D- D- D-4 D-5 D-7 TIM AUXILIAY SWITH BLK- UT LAY -0A -0A -0A D- D- D- D- D- D-4 D-4 D-4 D-6 D- D- D- D- D- D- D- D- D- D- D- D- D- D-4 D-4 D-4 D-4 D-4 D-4 D-6 D-6 D- D- D- D- D- D- D- D- D- D- D-4 D-4 D-4 D-4 D-6 NTATS DST HATS AN -0A -0A -5A -50A -50A -5A -50A -50A -5A -5A -5A -5A -5A -5A -5A -50A -50A -5A -75A -75A -5A -0A -5A -5A -5A -5A -0A -0A -5A -50A -50A -40A VAPATS 0/ 460/ D- D-5 D-5 D-8 D-8 () () D- D- D- D-5 D-5 D-5 D-5 D-8 D-8 D-8 D-8 () () () () D- D- D-5 D-5 D-5 D-5 D-8 D-8 D-8 D-8 D-8 () () SQUNING LAY D- D- 6 D-8 D- D- D- D-8 D-8 D- D- D- 4 D-8 VAPATS 0/ 460/ D- D-5 D-5 () () () () D- D- D- D-5 D-5 D-5 D-5 () () () () () () () () D- D- D-5 D-5 D-5 D-5 () () () () () D- D- D- D- D- D- () onsult factory. TIM Initiates the defrost cycle. Also used as over ride protection for defrost termination. AUXILIAY SWITH Mounted on the compressor contactor, it prevents the defrost contactor from operating whenever the compressor is energized. BLK-UT LAY Serves the same function as auxiliary switch, except used when defrost contactor is not required (single phase only). AN NTAT Used with 460 V. motors or when 0 V. motors are wired for phase power. DST NTAT arries amperage load for heaters. ontactor selection is based on the maximum resistive load rating of the contactor. SQUNING LAYS Provides interconnection of multiple unit coolers on a single system so that each unit cooler is allowed to individually terminate defrost on temperature. 0 Thomas rench Drive, Scottsboro, AL 5769 PHN (56) 59-7400 AX (56) 59-7478 witt.htpgusa.com