Outdoor Enclosure Power System ENC X100MP48F20

Similar documents
Outdoor Enclosure Power System ENC X100MP48F20-AC6

MODEL ELC-12/40-CVM-D BATTERY CHARGER

NetSure 5100 ORDERING GUIDE. 48V & 24V DC Power System (40 A to 600 A)

VERTIV XTE 401 SERIES. Ordering Guide

Switchgear Skid, C1192

GRANITE ENCLOSURES MODEL NO. NPS Standard Features

SITESTAR ELECTRONICS CABINET DESCRIPTION

E.S.P. Embedded Sensing Probes for Motor Brushes

Special Specification 6058 Battery Back-Up System for Signal Cabinets

The Z Series. SCR Power controllers for resistance heating applications. Zero-Fired SCR Power Controllers AMPS VAC

SPECIAL SPECIFICATION 6894 Communication Cabinet

APX Technologies, lnc.

SPECIAL SPECIFICATION 1788 Surveillance Cabinet

STATE OF NEW JERSEY DEPARTMENT OF TRANSPORTATION TRENTON, NEW JERSEY 08625

TECHNICAL SPECIFICATIONS for. Telecommunication Battery Backup Systems (TBS)

X100P Load Bank. Read all instructions before using the load bank. Contents

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Horizontal Circuit Switchers

Horizontal Circuit Switchers

Installation and Operations Manual

Publication No.: PSG

Magnum Mobile Generator MMG235 Specifications

Scope of Supply / Major Bill of Materials

AT30 SERIES BATTERY CHARGER

IOE-XXX-XXXX Training Guide

TRAC-Station BT Installation Instructions

Fan Coil Unit (FCU) Fan Motor Control

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Idle Free Systems, Inc. Reference Guide System Component Information

HPP1 MK5 Owner s Manual

Magnum Mobile Generator MMG75 Specifications

Fincor Series 2230 MKII/2240

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Table of Contents 文管中心 發行章

Industrial Generator Set Accessories

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

XS400 Load Bank. Read all instructions before using the load bank. Contents

APS150A SOUND ATTENUATED DUAL VOLTAGE/60HZ

Magnum Mobile Generator MMG125 Specifications

MODEL ELC-12/60-D BATTERY CHARGER

PS24/AC Volt AC 16 Amp

Installation Instructions

Operations and Service Manual. XE400D-SB Load Bank

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

eapu Reference Guide System Component Information (For serial numbers starting with 37)

Installation Instructions

Magnum Mobile Generator MMG75 SS Specifications

Installing Power Components

Unity Low Voltage Disconnect & Monitor

AGi20P 2.2 L 20 kw Perkins Powered Diesel Generator AURORA GENERATORS INCORPORATED AURORA STANDARD FEATURES STANDBY POWER RATING 20 KW, 20 KVA, 60 HZ.

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

Direct Gas-Fired Heating

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

C1000 Series Automatic Cap Bank

MaxPak Plus Analog DC V S Drive

FMV156DBB FMV156DCC FMV156DQB FMV156DSB

13,000 Watt Diesel Generator AGi13P E

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

! "! User Manual Myers Power Products CTEP/G Manual 6/2009

Seal Beach Police Department

Connect Series Accessories

"EH SERIES" POWER SUPPLIES "PS SERIES" POWER SUPPLIES EH SERIES PUBLIC SAFETY POWER SUPPLIES PS SERIES PUBLIC SAFETY POWER SUPPLIES

Three-Phase Pole Mounted Recloser

Tycon RPMS Installation Instructions

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL W30A1, W36A1. Models: Contents. General Notes. Important.

Mobile Generator MMG130 Specifications

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

Electric Furnace KF/KFS Series

Magnum Mobile Generator MMG330 Specifications

Connect Series Accessories

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

10,000 Watt Diesel Generator AGi9P E

XS500 Load Bank. Read all instructions before using the load bank. Contents

Industrial Generator Set Accessories

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

Cellwatch Battery Monitoring Systems

WF-5110R True Sine Wave Inverter

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

SE2000BX Static Exciter

CLIENT: PROJECT: PO#: ESTIMATOR:

Mobile Generator MMG25FHI Specifications

Mobile Generator MMG130 Specifications

Consider The Possibilities...

Dual ground lug - one lug for earth ground, one lug for utility ground.

User s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual

MB A 12V/24V DC PROGRAMMABLE DUAL BATTERY ISOLATOR

B BASIC HEAT TREATMENT CONSOLE

Mobile Generator MMG75D Specifications

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

Magnum Mobile Generator MMG175 Specifications

ACSI MODEL 1406BB-04-AO POWER SUPPLY INSTALLATION INSTRUCTIONS

HPP1 MK5 Owner s Manual

Mid-Power Remote Unit (MRU) SISO Outdoor Enclosure Assembly Quick Installation Sheet

The Power of Reliability INSTRUCTION MANUAL

DP140e. Installation & Operations Manual

Transcription:

Outdoor Enclosure Power System ENC673034-1X100MP48F20 Manual MA015152A1 Issue 1 Oct 2010 Copyright 2010 Myers Power Products, Inc. Part# A015152A1 MA015152A1 Iss1 Page 1 of 22

Dimensions Outdoor Enclosure Power System ENC673034-1X100MP48F20 is designed to meet NEMA N3R. Cabinet Weight: 455 Lbs ( without batteries ) 23 inch racks, 4 pair, horizontally adjustable ( forward and backward ) Rear vertical rack rails can be configured for 19 or 23 inch. Contiguous 20U available space, 33U total rack space 12-24 thread rack mounting holes use a tri-lobe screw to cut the paint MA015152A1 Iss1 Page 2 of 22

Exterior Overview Sunshield Aux Box VAC Breaker Box Generator Inlet Intake Fan Unit See Fan OEM Manual The intake fan is powered from the 48VDC power system within the cabinet. A low-voltage-disconnect ( LVD ) prevents the fan from overly discharging lead-acid batteries ( while running from batteries ). The LVD disconnects the fan at 42VDC and reconnects at 49VDC. Note that the LVD only disconnects the fan, nothing else. The t-stat within the fan interior is set to its coolest level so that the t-stat within the cabinet interior controls the fan ON / OFF. MA015152A1 Iss1 Page 3 of 22

Exterior Overview RF Plate Inside Rain Cover Intake Fan Backpressure Vent Cover Door Handle Allows for Pad Lock Ground Tab Extends Into Interior Doors Lift Off Their Hinges for More Ready Access to the Interior MA015152A1 Iss1 Page 4 of 22

Exterior Sunshield and Eye Bolts Sunshield Provides Additional Protection Against High Outdoor Ambient Eye-Bolts for Hoisting the Cabinet Remove Batteries Before Hoisting ( Part# A015152A1 Does Not Include Batteries ) MA015152A1 Iss1 Page 5 of 22

Exterior RF Plate and Rain Cover 16 Access Hole RF Plate Inside Rain Cover MA015152A1 Iss1 Page 6 of 22

Exterior Aux Box MA015152A1 Iss1 Page 7 of 22

Exterior Generator Inlet Commercial VAC Power and Generator VAC Power NEMA L14-30 Generator Plug MA015152A1 Iss1 Page 8 of 22

Exterior VAC Breaker Box VAC Fail Relay VAC Surge Suppressor VAC Fail Relay is Energized from the 208/220/240 VAC Input to the Breaker Box The relay provides an isolated 1-Form C contact closure take-off on TB1. Normally Closed is the de-energized position. See the TB1 pin-out information in this manual. MA015152A1 Iss1 Page 9 of 22

Exterior VAC Breaker Box Toggled Main Breakers Prevent Simultaneous Commercial and Generator VAC Power Input Use 120 / 240 VAC 30 Amp Service Breaker Position Breaker Type Description 1 & 2 2-Pole 30 amp Primary Input Commercial VAC Power 3 & 4 2-Pole 30 amp Generator Input from L14-30 Inlet Plug 5 1-Pole 20 amp 5-20R Duplex Receptacle Front Interior Light Back Interior Light 6 1-Pole 5-20R GFCI Duplex Receptacle Convenience Receptacle 7 & 8 2-Pole 20 amp 6-20R Duplex Receptacle Rectifier Shelf VAC Power MA015152A1 Iss1 Page 10 of 22

Interior / Exterior Duplex Receptacles 6-20R Duplex Receptacle Rectifier Shelf VAC Power 208 / 220 / 240 VAC 5-20R Duplex Receptacle Front Interior Light Back Interior Light 120 VAC 5-20R GFCI Duplex Receptacle Convenience Receptacle 120 VAC MA015152A1 Iss1 Page 11 of 22

Interior / Exterior Rear Door Interior / Door Handle / Dual Thermostat Door Wind Catch Louvered Vents Relieve Intake Fan Back Pressure Laptop Fold Out Tray Door Handle Allows for Padlock Dual Thermostat 13 & 14 Side Controls Intake Fan ( Set to 120 F ) 23 & 24 Side High Temperature Ambient Alarm ( Set to 120F ) Routed to the PSC500H J5.13 &.14 User Defined Input IN3. See the PSC500H Manual for more details of the power system controller. MA015152A1 Iss1 Page 12 of 22

Interior Master Ground Bus and Rectifier Shelf Master Ground Bus Power One Aspiro Rectifier Shelf The Leftmost Slot is Reserved and not Used DC Positive is tied to Chassis Ground within the Power System for a Negative 48VDC System. See the Power One Aspiro manual for more information on the rectifier shelf and the Aspiro rectifiers. Note that A015152A1 does not include the rectifier modules. The modules are ordered separately to choose between 400 watt or 800 watt Aspiro rectifier modules. MA015152A1 Iss1 Page 13 of 22

Interior GMT Fuse Panel The 20 Position GMT Fuse Panel Provides DC Power Distribution The GMT Fuse Panel Blown Fuse Alarm ( along with the Battery Breaker Aux Switch ) is Routed ( via TB1 ) to the PSC500 J3.5.6 Distribution Alarm Input See the GMT Fuse Panel Manual MA011391 for Details of the GMT Fuse Panel See the PSC500 Manual for Details of the Power System Controller MA015152A1 Iss1 Page 14 of 22

Interior Power System Controller / Battery Temperature Probe / Current Shunt PSC500H Power System Controller See the PSC500H Manual MA014882 for Details of the Power System Controller Rectifier Current Shunt Setting is 100 Amps in PSC500 Power Control screen ( Leave Battery Shunt at Zero Amps ) BATTERY TEMPERATURE PROBE & MID-POINT CONNECTION PSC500H J5 pos 3 ( Mid-Point ) and J4 pos 3 & 4 ( Temperature Sensor ) PROBE PLACEMENT MID VOLTAGE (-) (+) (-) (+) (-) (+) (-) (+) 12 Volt Battery 12 Volt Battery 12 Volt Battery 12 Volt Battery MA015152A1 Iss1 Page 15 of 22

Interior Terminal Block TB1 TB1, 12 Position, Dual Row, #6 Screw Terminals Signal Wire Interface and Take-Off TB1.1 &.2 Door Switch Contact Closure ( Front & Rear Door ) TB1.3 &.4 Interior High Temperature Ambient Contact Closure ( Dual T-Stat.23 &.24 ) TB1.5 &.6 Intake Fan Dual T-Stat.13 &.14 Contact Closure TB1.7 &.8 Distribution Alarm Contact Closure ( GMT Fuse Panel Alarm and Battery Breaker Alarm ) TB1.9 Normally Open VAC Fail Relay Contact Closure TB1.10 Common from the TB1.11 Normally Closed VAC Fail Relay Mounted in the VAC Breaker Box TB1.12 Spare MA015152A1 Iss1 Page 16 of 22

Interior Interior Lights and Door Switch Interior Light Front & Rear ( 120VAC Power ) Light Switch on each Light Fixture and Door Switch ( Intrusion Alarm ) The door switch contact closure is routed ( via TB1 ) to the PSC500H J5.11 &.12 User Defined Input IN2. See the PSC500 Manual for more details of the PSC500H power system controller. A door switch and light is installed at both the front and back doors. MA015152A1 Iss1 Page 17 of 22

Interior Battery Tray Battery Tray Designed for Front Terminal Batteries Can Also Hold Top Terminal Batteries Battery Tray Interior 20.625 W x 18.5 D A015152A1 Ships From the Factory with No Batteries Installed MA015152A1 Iss1 Page 18 of 22

Interior Battery Breaker Battery Breaker 60 Amp with Finger Guard The Battery Breaker Aux Switch ( along with GMT Fuse Panel Blown Fuse Alarm) is Routed ( via TB1 ) to the PSC500 J3.5.6 Distribution Alarm Input See the PSC500 Manual for Details of the Power System Controller MA015152A1 Iss1 Page 19 of 22

Schematic A015152A1 MA015152A1 Iss1 Page 20 of 22

Optional Cabinet Base Part# M000049W MA015152A1 Iss1 Page 21 of 22

History MA015152A1 Original source document located at: \\DATXNAS01\common2 on Datxnas01\ADSENG\MANUALS\A015152A1 Oct 2010 Issue 1 Originate MA015152A1 manual from MA015151A2 manual Myers Power Products, Inc. ( 909 ) 923-1800 PST MA015152A1 Iss1 Page 22 of 22