KD1E Range Potential Indicators

Similar documents
Rental Industry Safety Tester Safe Check 5s

Date received into service; / /.

BM kv Digital Insulation Tester USER MANUAL

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Switching DC Power Supply

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

1.Safe testing IMPORTANT:

Instruction Manual & Specification

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

Visit us at

OPERATING INSTRUCTION

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Battery Charger JCB- SCH20LI.2

BATTERY CHARGER Instruction Manual

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

27.6 Vdc 1 Amp Switch Mode Power Supply for Fire EN54-4:1997 +A1 +A2

Non-Contact Phase Rotation Tester

JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: , & GC0514

362 Clamp Meter. Users Manual

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

SafetyPAT Plus A B P/N:

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

ANALOGUE INSULATION-CONTINUITY and VOLTAGE METER

Visit us at

90W DC Power Supply. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Battery Charger JCB-FCH20LI2

EASY CHARGE Waterproof portable Battery Charger

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

EV110. Electric Vehicle Supply Equipment Tester. Operating Instructions

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

Verti Blast. User Manual. Order code: EQLED355

Operating instructions in the back. PD1820LF

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

OPERATING INSTRUCTION

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

LEAD ACID BATTERY CHARGER

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

KMP Insulation-Continuity Tester. Users Manual

Operating instructions in the back. PD1420LP

DIGITAL RCD(ELCB) TESTER

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Users Manual. Phase Rotation Indicator

Operating Instructions

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

PREMIER POWER PACK INSTRUCTION MANUAL EN54-4 POWER SUPPLY UNIT INSTRUCTION MANUAL. GLT.MAN-138 Issue: /05/2016 N.R.P.J.

Installation manual portable distributors

Battery Charger JCB-FCH12Li

USER MANUAL. 10KV Digital High Voltage Insulation Tester. Model MG500. Additional User Manual Translations available at

BATTERY CHARGER Instruction Manual

Operating Instructions

PY-11 Voltage & Continuity Tester

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

Mini Multimeter with Non-Contact Voltage Detector (NCV)

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

DIGITAL BATTERY TESTER 12V

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

24V 3A EN54 Ancillary Power Supply

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0

Visit us at

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

VoltageTester& PhasingOut

User's Manual Digital High Voltage Insulation Tester Model

323/324/325 Clamp Meter

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

SimplePAT. Battery Powered Portable Appliance Tester. User Manual Issue 1.0

LED Emergency Luminaires

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

Cordless Rechargeable Saw Instructions for Use

12 amp RMS Battery Charger

JUMPSTART MODEL NO: JS900/JS910 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC10/16

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

BATTERY CHARGER-STARTER

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

BATTERY CHARGER RS-1000 Instruction Manual

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Atlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter. Model ESR60/ESR70. Designed and manufactured with pride in the UK.

POCKET-TACH 100 MONARCH INSTRUMENT Rev 1.4. Instruction Manual. Printed in the U.S.A. Monarch Instrument 2001 all rights reserved

7 Handle Tubes. 10 Charging Jack 11 LED Indicator 12 ON/OFF button

28W WORK LAMP Model: CTL28 Part No:

Installation manual wall-mounted distributor

Phase Sequence Tester

TESTER SET SOCKET & VOLTAGE

MAINTAINED LED DOUBLE SIDED SUSPENDED CEILING MOUNTED EMERGENCY LIGHT

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

CONTACTS EGR VALVE TESTER 66248

Transcription:

KD1E Range Potential Indicators Operating Instructions 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com

Limited Warranty & Limitation of Liability SEAWARD Electronic Limited guarantees this product for a period of 1 year. The period of warranty will be effective at the day of delivery. Copyright 2014 All rights reserved. Nothing from this edition may be multiplied, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from SEAWARD Electronic Limited. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development SEAWARD Electronic Limited reserves the right to alter the equipment specification and description outlined in this publication without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. 1

Disposal of Old Product This product has been designed and manufactured with high quality materials and components that can be recycled and reused. When the crossed out wheelie bin symbol is attached to a product it means the product is covered by the European Directive 2012/19/EU. Please familiarise yourself with the appropriate local separate collection system for electrical and electronic products. Please dispose of this product according to local regulations. Do not dispose of this product along with normal waste material. The correct disposal of this product will help prevent potential negative consequences for the environment and human health. 2

Operating Instructions KD1E Range Potential Indicator The Seaward KD1E range of Potential Indicators provides a means of confirming the presence of voltage on electrical circuits from 1.5 to 33kV. The KD1E Range of Potential Indicators complies with the UK Electricity Council Engineering Recommendation G9. Contents 1. User Notes 2. Safety Notes 3. Standard Accessories 4. Description 5. Electrical Specifications 6. Operation 7. Battery Charging 8. Optional Extension & Bent End Rods 8. Proof Testing 9. Maintenance 10. Cleaning 1.0 User Notes These operating instructions are intended for the use of competent personnel. The KD1E Range of Potential Indicators has been designed to make measurements in a dry environment. The KD1E Neon Range of Potential Indicators has been designed for indoor use. The KD1E Digital Range of Potential Indicators has been designed for outdoor use. The following symbols are used in these operating instructions and on the KD1E Range of Potential Indicators Warning of electrical danger! Indicates instructions must be followed to avoid danger to persons. Important, follow the documentation! This symbol indicates that the operating instructions must be adhered to in order to avoid danger. 3

2.0 Safety Notes This KD1E Range of Potential Indicators has been built and tested in accordance with: BS EN 61243-2 The KD1E Range of Potential Indicators has left the factory in a perfectly safe state. To maintain this state and ensure safe operation of the unit, all notes and warnings in these instructions must be observed at all times. This instrument should only be used by competent, suitably trained personnel, wearing appropriate PPE, after due consideration of any hazard involved. Never hold the instrument between the hand guard / digital display housing and the contact electrode. The Potential Indicator and all associated cables and leads must be checked for signs of damage before the equipment is operated. The Potential Indicator must be proof tested before and after use. Always ensure the earth cable is securely attached to the equipment and that the clip is connected to earth during tests. Always ensure equipment is properly rated for use at the voltage in the system under test. Never allow any part of the instrument below the limit mark to make contact with a live high voltage conductor. Where applicable, the limit mark is a band, approx. 20mm in width, printed on the body of the detector and extensions rods. 4

Where safe operation of the Potential Indicator tester is no longer possible it should be immediately shutdown and secured to prevent accidental operation. It must be assumed that safe operation is not longer possible: - if the Potential Indicator or the cable show visible signs of damage, or - the Potential Indicator does not function, or - after long periods of storage under adverse environmental conditions. 5

3.0 Accessories 3.1 Optional Accessories 3.1.1 PH3 proof testing unit, for use with contact electrode type domed Seaward Part 112A913. Supplied with digital readout models. 3.1.2 PH3 proof testing unit, for use with contact electrode type flat Seaward Part 112A921. Supplied with digital readout models. 3.1.3 V form 1.5m straight extension rod. Seaward Part 141A901. 3.1.4 Domed bent end extension rod. 90 degree (Seaward Part 141A900) or 120 degree (Seaward Part 141A912) PSU100 battery charger Seaward Part 124A912. 6

4.0 Description The KD1E range of neon and digital potential indicators are comprised of the following features:- 4.1 The units consist of an element manufactured from a high quality PVC grade 7 tube that conforms to BS3506. The tube supports and isolates a chain of high value internal resistors. 4.2 The total encapsulation of the load element prevents any internal tracking or leakage. 4.3 A handguard in the form of a flange (neon type) or display housing (digital type) on the handle section of the unit prevents the operators hands from straying towards the high voltage ends of the potential indicator. 4.4 Type neon indicator. The neon indicator is enclosed in a flexible transparent sleeve that prevents the transmission of any outside shocks to the glass envelope of the neon. 4.5 Type neon indicator. The neon s are visible through a viewing window located in the PVC tube above the handguard. 4.6 Type digital indicator. The voltage display is incorporated into the handguard housing. 4.7 An external domed or flat type (model specific) ensures a positive contact with any terminal required to be tested. 4.8 An insulated earth cable is connected to the potential indicator through the handle section. The earth cable is a permanent connection on neon indicator models but is detachable on digital models. This earth cable is fitted with a suitable clamp that allows the operator to reference the potential indicator to a suitable earth. 4.9 Labels present on the equipment and accessories are there to ensure safe use of the equipment. 7

5.0 Electrical Specifications Type Model Neon Indication Digital Reading KD1E KD1E/19 KD1E/19s KD1E/22 KD1E/33 KD1E/15D KD1E/33D Maximum System voltage Maximum System to earth Threshold voltage Measuring Range Resolutionn Sensivity 11kV 19kV 19kV 22kV 33kV 15kV 33kV 6.6kV 11kV 11kV 12.5kV 19kV 8.6kV 19kV 300 300 300 300 300 / / / / / / / 0.00-8.60kV 0.00-19.0kV / / / / / 10V 100V AC/DC AC/DC AC Only AC/DC AC/DC AC/DC AC/DC Circuit Current (IEC61243-2) 2.3mA nominal @ 6.6kV 0.7mA nominal @ 11kV 0.9mA nominal @ 11kV 3.5mA nominal @ 12.5kV 1.1mA nominal @ 19kV 0.5mA nominal @ 8.6kV 1.1mA nominal @ 19kV Dielectric Leaking Current (IEC61243-2) 7µA nominal @ 13.8kV 11µA nominal @ 22.8kV 12µA nominal @ 22.8kV 12µA nominal @ 26.4kV 17µA nominal @ 40kV 9µA nominal @ 18kV 17µA nominal @ 40kV Length [mm] Diameter [mm] Handle length [mm] Hand Guard Height [mm] Contact Electrode Type 330 330 330 665 670 600 600 27 27 27 27 27 27 27 105 105 105 90 250 235 235 23 23 23 20 20 25 25 Domed Flat Flat Domed Flat Domed Domed Extension Rods 1.5m Straight 90 Bent 120 Bent Maximum System voltage Dielectric Leakage Current Length [mm] Diameter [mm] Contact Electrode Type 33kV 140µA nomnial 1500 27 V form 15kV 50µA nomnial 780 27 Domed 33kV 130µA nomnial 780 27 Domed 8

6.0 Operation 6.1 Type digital indicator. The insulated earth cable, 3m in length, is connected by means of a plug and socket arrangement to the bottom of the handheld section of the potential indicator. 6.2 Type digital indicator. On connection of the insulated earth cable to the bottom of the handheld section the digital display is automatically powered up and zeroed ready for operation. Always screw up the plug and socket securely. 6.3 The earth clamp attached to the free end of the insulated earth cable needs to be attached to a suitable earth point i.e. an earthed strip of frame or an earth electrode. 6.4 Before use the potential indicator must be proof tested on a suitable proving unit such as the Seaward Electronics PH3 proving unit. This proving unit is supplied with digital indicator models and is an optional accessory for neon indicator models. The neon indicator will illuminate for an energised system or for a proving unit test. If no neon illumination occurs for a proving unit test then the potential indicator must be returned to the supplier. 9

6.5 The exposed contact electrode of the potential indicator should be positioned such as to make contact with the voltage source to be measured. For neon model indicators the neon s within the PVC tube will be illuminated to inform the operator that a voltage greater than the threshold voltage of the detector is present. For the digital model indicators the display will indicate a reading to inform the operator of the exact value of the voltage present. Never hold the potential indicator between the hand guard and the exposed contact electrode. 6.6 The potential indicator must be applied in turn to each phase of the system under test. 6.7 After use the potential indicator must be proof tested on a suitable proving unit such as the Seaward Electronics PH3 proving unit. 6.8 Type digital indicator. Once testing is complete unclip the earth clamp from the reference earth point. Disconnect the earth cable from the bottom of the potential indicator and replace the protective cap over the plug of the potential indicator. Digital indicator only. Always ensure the earth cable is disconnected from the potential indicator when not in use to prevent the battery from being fully discharged. 10

7.0 Battery Charging This section is a requirement for digital reading potential indicators only. A BAT sign on the display of the digital potential indicator denotes that the battery requires charging. During prolonged storage periods the battery will discharge. In order to increase the battery life the instrument should be charged periodically. 7.1 Remove the protective cap from the connector on the bottom of the hand held section of the indicator. 7.2 Insert the 6 pin socket flying lead from the PSU100 battery charger Seaward Part 124A912 into the connector and firmly screw into place. Connect the mains lead from the charger to a 240VAC 50Hz supply and switch on. 7.3 Once mains has been applied to the battery charger one LED is continuously illuminated and a second LED will flash approximately every 5 seconds to indicate the digital display battery is being charged. 7.4 The charging period should be approximately 14 hours. Once charging is complete both LED s are switched off. 7.5 On completion of the charging cycle, disconnect the battery charger supply from mains, disconnect the 6 pin socket from the base of the potential indicator and replace the protective cap over the plug. Do not use the potential indicator on a high voltage circuit while the battery is on charge. 11

8.0 Optional Extension & Bent End Rods 8.1 Attachment 8.1.1 Loosen but do not fully remove the knurled head on the extension rod. 8.1.2 If the equipment is fitted with removable contact electrodes, remove the domed head from the digital unit or neon unit. Store the domed heads in a safe location. 8.1.3 Attach the extension rod onto either the digital unit or neon unit and ensure that the two elements are fully mated without over tightening. 8.1.4 Tighten the knurled head at the end of the extension rod to secure the two elements together. At no time after the extension unit has been fully tightened to either the digital unit or phasing rod should any attempt be made to separate the two elements until all testing (including proof testing) has been completed. 8.1.5 To remove an extension rod from either the digital unit or neon unit, loosen the knurled head at the end of the extension rod before detaching the extension rod from either the digital unit or the phasing rod. 8.1.6 Replace the domed head on the digital unit and / or neon unit and tighten the knurled head on the extension rod when complete. 12

8.2 Operation of Extension and Bent end Rods on HV Systems 8.2.1 Extension rods can be used on a HV system with either the digital unit or neon unit. Extension rods cannot be used without first being connected to either a digital unit or neon unit. 8.2.2 The digital unit and phasing rod can be used on a HV system up to the designated voltage levels without an extension rod. Always fit the forked head to extension rods when testing Overhead Lines. 8.3 Proof Testing of the Extension Rod 8.3.1 Extension rods must be proof tested using the Seaward PH3 proving unit, both before and after use. For more detailed information see section 9. 13

9.0 Proof Testing 9.1 Features of a PH3 Proving Unit 9.1.1 The terminations on the unit comprise of a knurled earth terminal at one end and a small test point on the top of the unit. The PH3 is available with a test point designed to mate with either a domed or a flat contact electrode type. Refer to section 3.1. 9.1.2 A push switch operates the test voltage output. 9.1.3 The unit requires an alkaline PP3 type battery, also identified as a MN1604 and with the IEC identifier 6LR61. 9.1.4 Ensure that the red LED on the proving unit operates before and after the unit has been used. Warning Do not touch the earth terminal and the brass tip on the proving unit simultaneously. When the push button is pressed 1.3KV is generated between these points. 9.2 Testing Potential Indicators using a PH3 Proving Unit. 9.2.1 Type digital indicator. Using the 6 pin plug on the base of the potential indicator connect the insulating earth cable to the indicator and securely fasten. 9.2.2 The earth clamp attached to the free end of the insulated earth cable should be attached to the knurled earth terminal on the proving unit. 14

9.2.3 Push the brass tip on the proving unit onto the exposed contact electrode of the potential indicator. 9.2.4 Press the pushbutton on the proving unit. The neon s on neon potential indicator models will illuminate to prove the indicator is operational. The display on digital tential indicators will indicate a voltage of greater than 1.1kV. Warning Do not touch the earth terminal and the brass tip on the proving unit simultaneously. When the push button is pressed 1.3KV is generated between these points. 9.2.5 On completion of the proving test, release the push button, disconnect the earth clamp from the knurled nut and remove the proving unit brass tip from the exposed metal head of the potential indicator. 15

10.0 Maintenance 10.1 The KD1E range of potential indicators is extremely robust and should always be kept free from dust or any loose carbon particles. 10.2 Ensure the KD1E range of potential indicators is kept dry with no surface moisture on either the body or housing / hand guard of the indicator. 10.3 The body of the potential indicator should be regularly inspected to ensure no deep scratches or physical damage. 10.4 Ensure the insulation of the cable is fully intact and that no sharp creases have occurred in the cable. 10.5 It is recommended that the potential indicator should be regularly proof tested at scheduled maintenance intervals as well as before and after testing on energised circuits. 10.6 If any of the above conditions have been observed then the potential indicator must be appropriately secured to prevent any further use. 10.7 Ensure that the equipment is stored dry with no surface moisture on the body or housing / hand guard of the indicator or phasing rod. 10.8 Always transport the equipment in the carrying case provided. Always handle with care. 10.9 There are no user serviceable parts on the equipment. Digital Indicator only Always ensure the earth cable is disconnected from the potential indicator when not in use, to prevent the battery from being fully discharged. 16

11.0 Cleaning 11.1 Clean the external case of the potential indicator with a clean dry cloth. 11.2 Avoid using solvents and abrasive scouring agents to clean the external case of a potential indicator. 11.3 Type digital indicator. Check the battery contacts and mounting compartment are free of electrolytic contamination. 11.4 Type digital indicator. Any contamination of the battery contacts or compartment should be cleaned with a dry cloth. 17

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 113A550 Rev 2