Multi-Function Ground Resistance Tester Model 6472

Similar documents
Digital Transformer Ratiometer

Fall-of-Potential Ground Testing

Advanced Test Equipment Rentals ATEC (2832)

For all of your Ground T esting needs. Technical Hotline: (800) Ground Testers

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Ground Resistance Tester Model 3620 & 3620 Kits

Digital/Analog Megohmmeter Model 1026 USER MANUAL

MEGOHMMETER. User Manual

Digital Insulation Resistance Testers. you can depend on

Digital/Analog Megohmmeter Model 1026

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

Megohmmeter Test Probe

USER MANUAL. Insulation Tester + DMM. Model MG320

DLRO10HDX 10 Amp Digital Low Resistance

MJÖLNER 200 Microhmmeter

5 kv and 10 kv Insulation Resistance

MIT515, MIT525, MIT1025, MIT1525

S1 Series. 5-kV and 10-kV Insulation Resistance Testers. S1 Series 5-kV and 10-kV Insulation Resistance Testers

Autoranging Industrial Multimeter

K100 K110 AEMC INSTRUMENTS ENGLISH. User Manual. n DC/AC MICROPROBE. Model K mv/ma OFF. DC/AC MicroProbe

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

ABB Component Drives ACS150, 0.5 to 5 Hp

HD110C Heavy-Duty Digital Multimeter

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Fluke 500 Series Battery Analyzers

S1-568, S1-1068, S1-1568

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

MIT515, MIT525 and MIT & 10 kv DC Insulation Resistance Testers

MIT300 Series Insulation and Continuity Testers

ALL-TEST PRO 5. The AT5 Motor Circuit Analyzer Complete electric motor health analysis in minutes! Motor Circuit Analyzer

UTM10 Series Ultrasonic Transit-time Flowmeters

Portable Transit Time Flow Meter for Accurate Flow Measurement from Outside a Pipe

CONTINUITY TESTER FOR METALLIC & REMOTELY BONDED STRUCTURES

Selectable Impedance Adapter

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

PAT120, PAT150 and PAT150R

User Guide. Model Insulation Tester / Megohmmeter

Model 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Data Sheet Type FF420. Series 420 Specification Flange / Flange. Series 420 Non-Contact Rotary Torque Transducer

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Digital Low Resistance Ohm Meter

True RMS Autoranging Multimeter

DLRO-H200 Microhmmeter

DET Series EARTH GROUND ELECTRODE TESTERS

Model Insulation Tester / Megohmmeter. User Manual

Mini Multimeter with Non-Contact Voltage Detector (NCV)

EARTH RESISTANCE DET24C

MOM2 Microhmmeter. MOM2 Microhmmeter. Up to 220 A. Battery supplied. Lightweight 1 kg. Safe test DualGround. Auto range: 1 µω to 1000 mω

2-Color Display High-Precision Digital Pressure Switch

MIT515, MIT525, MIT1025, MIT1525 5, 10 & 15 kv DC Insulation Resistance Testers

Mini Multimeter with Non-Contact Voltage Detector (NCV)

User Guide. Model Insulation Tester / Megohmmeter

HC1, HC2 and HC9. Helmholtz Coil Systems

Digital display Pressure range ON/OFF output Linear output Model

90HJRKPPHWHU 0RGHO1 (6'&RQGX WLYLW\7HVW.LW

HUMIDITY / TEMPERATURE TRANSMITTER

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Est Battery Data Logger BDL3000

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

Autoranging Multimeter

Phase Sequence Tester

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

OPERATING INSTRUCTION

User Manual. PF0.9 1K/2K/3K Online UPS. Uninterruptible Power Supply System. Version: 1.3

PIECAL 520B & 521B Thermocouple Source Operating Instructions

Motive Power Solutions

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

PCBA Instruction Manual

LRCD200 Series Combined Loop and RCD Tester USER MANUAL

Onfiniti. 1 Phase UPS

Power Switching Devices

Clamp Earth Tester MET-2. Instruction Manual

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Instruction Manual IVT-10 / IVT-20 Voltage Tester

OPERATING MANUAL EARTH RESISTANCE METER MRU-20

Model 422 Automated Thermocouple Calibrator Operating Instructions. Product Description

Model R1L-C Series. Operation and Maintenance Manual

DET3TA, DET3TC, DET3TD and DET4TD Earth Ground Electrode Testers USER MANUAL

Date received into service; / /.

ULTIMA W SERIES. 1K/2K/3K Online UPS USER MANUAL

ELECTRICITY GENERATION, TRANSMISSION AND DISTRIBUTION. Our solutions for metering, measurement and analysis IEC 61850

INSTRUCTION MANUAL IDM67 DIGITAL MULTIMETER

Advanced Test Equipment Rentals ATEC (2832)

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

DT304. Digital Temperature Logger INSTRUCTION MANUAL

Inductive Proximity Sensor

ABB component drives ACS150, 0.5 to 5 Hp

This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice.

LDX-U20 is a microprocessor controlled DC-UPS rated 20 A usable in 12 V or 24 V systems.

Inductive Proximity Sensor

Heat Shield Portable wireless WBGT meter

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

MagFlux Q 8200 Series

Uninterruptible (ATX) Switching Power Supply. MODEL eups-350

DIGITAL RCD(ELCB) TESTER

PROVA 1011 Solar System Analyzer

Transcription:

Multi-Function Ground Resistance Tester Model 6472 NEW! The Model 6472 measures from 0.01 to 99.99kΩ and is auto-ranging, automatically seeking out the optimum measurement range, test frequency and test current. Easy-to-use Simply connect the leads, select test mode, press Start and read the results. Up to 512 test results can be stored in internal memory for recall to the display or downloaded to a PC via DataView software. The large LCD is easy-to-read and indicates ground electrode resistance, test voltage, current and frequency as well as individual electrode resistance, battery status and more. The Model 6472 is Cat IV rated to 50V and is over voltage protected to more than 250Vac against accidental live connection to live circuits. The voltage is also displayed on screen. In the event of a system fault, the Model 6472 can withstand 250Vac. Additional features of the Model 6472 include; manual and automatic test frequency selection from 40 to 5078Hz; user selectable 3 or 4-Pole Fall of Potential or 4-Pole Soil Resistivity test methods and user selectable 2-Wire or 4-Wire Bond Resistance test method. The Model 6472 is powered by 9.6V, 3.5 Ah NiMH rechargeable batteries. An external recharger powered from 120/230V, 50/60Hz is included and provides for testing while recharging. The Model 6472 can also be vehicle powered from an optional 12V battery adapter. (Cat. #2135.42) Technical Assistance (800) 343-1391 www.aemc.com 1 of 11

Features 2- and 4-Wire Bond Resistance/ Continuity Measurement (DC Resistance) with automatic polarity reversal 3-Point Fall-of-Potential measurement with manual or automatic frequency selection 4-Point soil resistivity measurement with automatic calculation of Rho (ρ) and user selection of the Wenner or Schlumberger test method 3-Point earth coupling measurement Measures Ground Resistance using the 2 clamp method (selective ground testing) Measures Ground Impedance at frequencies up to 5kHz to test lightning strike protection Manual and automatic frequency scan from 40 to 5078Hz for optimum test accuracy in electrically noisy environments Selectable test voltage of 16 or 32V up to 250mA of test current Auto-off power management Automatic recognition of all electrode connections and their resistance value Stores up to 512 complete test results Optically isolated USB communication Remote set up and operation of all measurements using DataView software Automatic report generation including the fall of potential plot Rechargeable NiMH batteries from wall charger or vehicle power Rugged dustproof and rainproof field case Includes DataView software for data storage, real-time display, analysis, report generation and system configuration Applications 3-Point measurements of resistance to ground of ground rods and grids. 3-Point measurements are generally used when the electrode or grid can be easily disconnected. 4-Point tests or soil resistivity measurements. Locating areas of lowest soil resistivity is essential for achieving an economical grounding installation. Touch and step potential testing measurements. These tests are recommended when the ground cannot be disconnected, where ground faults are highly likely to occur, or when the footprint of grounded equipment (the outline of the part of equipment in contact with the earth) is comparable to the size of the ground to be tested. 2- or 4-Wire tests for continuity tests on bonding or on grounding systems. This test is a DC resistive test using 250mA or more and is used to check bonding of all connection points on the ground system. Earth coupling measurement and display. Used to estimate the influence of two earth resistance systems that are not connected to each other. Technical Assistance (800) 343-1391 www.aemc.com 2 of 11

functional displays 4-Point Bond Test 3-Point Fall-of-Potential Test The 4-Point Bond test displaying lead connections, bond resistance test results, test voltage and current. The 3-Point Fall-of-Potential test displaying test lead connection, grounding electrode resistance, test voltage and frequency. Frequency Selection Test Data Storage The Frequency selection screen displays selected test frequency and voltage for the test as well as lead connection. Memory Recall displays test results stored at a specific memory location. Schlumberger Test Wenner Test The Schlumberger test displays test lead connection, soil resistivity (ρ) test results, test electrode resistance and more. The Wenner test displays test lead connection, soil resistivity (ρ) test results, electrode spacing and resistance. Technical Assistance (800) 343-1391 www.aemc.com 3 of 11

specifications MODEL 6472 ELECTRICAL 3-Pole Measurement 0.09Ω to 99.9kΩ Resolution 0.01Ω to 100Ω Test Voltage / Current Nominal 16 or 32VRMS user selectable; Up to 250mA Resistance Measurement Frequency 41 to 5078Hz user selectable or automatic selection ±2% of Reading + 1ct @ 128Hz Earth Coupling Measurement Yes 4-Pole Measurement 0.001 to 99.99kΩ Resolution 0.001 to 10Ω Test Voltage 16 or 32V user selectable Resistance Measurement Frequency From 41 to 5078Hz selectable ±2% of Reading + 1cts @ 128Hz NOTE: 4-Pole Measurement with 1 Clamp SR182 (same specification as the 4-Pole measurement) 4-Pole Measurement with 1 Clamp MN182 (same specification as the 4-Pole measurement + 5%) 2 Clamp Measurement 0.01 to 500Ω Resolution 0.01 to 1Ω Frequency 128Hz, 1367Hz, 1611Hz, 1758Hz with SR182 ±10% of Reading + 1cts with MN182 ±20% of Reading + 2cts Soil Resistivity 4-Pole Measurement Test Method Wenner or Schlumberger selectable with automatic calculation of test results in Ω-meters, Ω-cm or Ω-feet 0.01 to 99.99kΩ; ρ Max: 999kΩm (display in kωft is not possible) Resolution 0.01 to 100Ω Test Voltage 16 or 32V user selectable Frequency From 41 to 128Hz selectable ±2% of Reading + 1cts Earth Potential Measurement 0.01mV to 65V Resolution 0.01 to 10mV ±2% of Reading + 1ct @ 128Hz Frequency From 41 to 128Hz selectable 2% of Reading + 1cts External Voltage Measurement 0.1 to 65.0VAC/DC DC to 440Hz ±2% of Reading + 1cts Input Impedance 1.2MΩ External Current Measurement with SR182 0.01 to 40.0A 16 to 400Hz @ 50 to 99Hz ±5% of Reading + 2cts from 0.01 to 100mA; ±10% + 2cts from 0.1 to 40A with MN182 0.01 to 9.99A 16 to 400Hz @ 50 to 99Hz ±7% of Reading + 2cts from 0.01 to 100mA; ±15% + 2cts from 0.1 to 10A Resistance Measurement (Bond Testing) IEC 61557/4 Measurement Type 2-Pole (with lead resistance compensation) or 4-Pole (Kelvin sensing) user selectable 2-Pole 0.01Ω to 99.9kΩ; 4-Pole 0.001Ω to 99.99kΩ ±2% of Reading + 2cts Test Voltage / Current 16Vdc (+, - or auto polarity); Up to 250mA max Data Storage Memory Capacity 512 test results Communication Optically Isolated USB Automatic Report Generation Yes Tabular listings, Fall-of-Potential plots and Frequency/Resistance plots Power Source 9.6V rechargeable battery pack Recharging Source 110/220 50/60Hz external charger with 18Vdc, 1.9A output or 12V vehicle power Technical Assistance (800) 343-1391 www.aemc.com 4 of 11

MECHANICAL Test Lead Connection 4mm recessed banana jacks Mechanical Shock Per EN 61557 Vibration Test Per EN 61557 Drop Test Per EN 61557 Dielectric Test 3kV 50/60Hz Dimensions 10.7 x 9.76 x 5.12" (272 x 248 x 130mm) Weight 7.5 lbs (3.5kg) Case Polypropylene Index of Protection IP53 with cover closed DISPLAY Display Type Custom 256 segment multi-line LCD Backlight Blue electroluminescent COMMUNICATION Software DataView graphing, analysis and reporting software ENVIRONMENTAL Operating Temperature 14 to 122 F (-10 to 55 C) Storage Temperature -40 to 158 F (-40 to 70 C) SAFETY Safety Rating EN61010-1 50V Cat IV, Pollution Degree 2 Double Insulation Yes CE Mark Yes Ground Resistance Tester Model 6472 Kit (500 ft kit shown) includes meter, NiMH batteries, optically isolated USB cable, DataView software, external battery charger, AC power cord, one 30 ft green wire, one each 500 ft red and blue wire, one each 100 ft black and green wire, set of five spade lugs, four 14.5" auxiliary electrodes, tape measure (100 ft), carrying case and user manual. Catalog #2135.54 Technical Assistance (800) 343-1391 www.aemc.com 5 of 11

construction faceplate Large, electroluminescent backlit liquid crystal display USB communications port DC power input Z Electrode terminal Y Electrode terminal Rotary function selection switch Xv Electrode terminal X Electrode terminal Start / Stop test button Six program / function buttons Technical Assistance (800) 343-1391 www.aemc.com 6 of 11

dataview software Data Analysis and Reporting Software Configure all functions of the Model 6472 Run tests and analyze real-time data from your PC Configure all test functions and parameters from your PC Customize views, templates and reports to your exact needs Create and store a complete library of configurations that can be used with the Model 6472 as needed Display Fall-of-Potential plots, tabular listings of test results, resistance vs. frequency plots, soil resistivity and bonding tests Print reports using standard or custom templates you design Free updates are available through our website www.aemc.com DataView is included with the Model 6472. Fall-of-Potential Plot % 90 80 72 Model Serial # Voltage Electrode (Y) distance from Ground Rod under Test (X) Measured Resistance FEET OHMS 180 49.3 160 34.2 144 22.1 100 90 DataView software provides a convenient way to configure and control ground resistance tests from your computer. Through the use of clear and easy-to-use tabbed dialog boxes, all of Model 6472 functions can be configured and tests can be initiated. Results can be displayed in real time and stored in your PC. Reports may be printed along with the operator s comments and analysis. Name of Operator Location Date Ground System Type: Single Rod Rod Depth ft Multiple Rods (Grid) Test Conditions Temp: Soil: Moist Dry Soil Type Longest Diagonal Dimension ft Z Electrode Distance ft Loam Sand & Gravel Shale Clay Limestone Sandstone Granite Slate Other Minimum System Requirements: Windows 2000/XP/Vista operating system 128MB of RAM for Windows 2000 (256MB recommended) 256MB of RAM for Windows XP 512MB of RAM for Windows Vista 80MB of hard disk space (200MB recommended) CD-ROM drive Windows is a registered trademark of Microsoft Corporation in the United States and/or other countries. 70 62 60 52 50 40 30 20 140 124 120 104 100 80 60 40 22.1 21.8 21.8 21.6 21.6 20.4 16.2 12.8 20 10 9.1 0 Resistance (Ω) 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Y Electrode Distance in % from the Grounding Electrode to the Z Electrode Typical report showing Fall-of-Potential plot using DataView software. Technical Assistance (800) 343-1391 www.aemc.com 7 of 11

dataview functional displays Data Analysis and Reporting Software Technical Assistance (800) 343-1391 www.aemc.com 8 of 11

dataview functional displays Data Analysis and Reporting Software Technical Assistance (800) 343-1391 www.aemc.com 9 of 11

accessories Test Kit for 3-Point testing includes two 150 ft color-coded leads on spools (red and blue), one 30 ft lead (green), two 14.5" T-shaped auxiliary ground electrodes, one set of five spade lugs, 100 ft tape measurer and carrying bag. Catalog #2135.35 Test Kit for 4-Point testing includes two 300 ft color-coded leads on spools (red and blue), two 100 ft color-coded leads (green and black), four 14.5" T-shaped auxiliary ground electrodes, one set of five spade lugs, 100 ft tape measurer and carrying bag. Catalog #2135.36 Test Kit for 4-Point testing includes two 500 ft color-coded leads on spools (red and blue), two 100 ft color-coded leads (green and black), one 30 ft lead (green), four 14.5" T-shaped auxiliary ground electrodes, one set of five spade lugs, 100 ft tape measurer and carrying bag. Catalog #2135.37 Test Kit for 3-Point testing (supplemental for 4-Point testing) includes two 100 ft color-coded leads, one 30 ft lead (green), two 14.5" auxiliary electrodes and soft carrying bag for use with kit number 2135.35 when 4-Point soil resistance testing is necessary. Catalog #2135.38 ORDERING INFORMATION CATALOG NO. Ground Resistance Tester Model 6472...Cat. #2135.51 Includes rechargeable NiMH batteries, optical USB cable, power adapter 110/240V with power cord 115V US, DataView software, ground tester workbook CD, carrying bag for meter, product warranty and registration card and a user manual. Ground Resistance Tester Model 6472 Kit (150 ft)...cat. #2135.52 Includes meter, rechargeable NiMH batteries, optical USB cable, power adapter 110/240V with power cord 115V US, two 150 ft color-coded leads on spools (red/blue), one 30 ft lead (green), two T-shaped auxiliary ground electrodes, set of five spaded lugs, one 100 ft AEMC tape measure, DataView software, ground tester workbook CD, carrying bag for meter, carrying bag for kit, product warranty and registration card and a user manual. Ground Resistance Tester Model 6472 Kit (300 ft)...cat. #2135.53 Includes meter, rechargeable NiMH batteries, optical USB cable, power adapter 110/240V with power cord 115V US, two 300 ft color-coded leads on spools (red/blue), two 100 ft color-coded leads (hand-tied, green/black), four T-shaped auxiliary ground electrodes, set of five spaded lugs, one 100 ft AEMC tape measure, DataView software, ground tester workbook CD, carrying bag for meter, carrying bag for kit, product warranty and registration card and a user manual. Ground Resistance Tester Model 6472 Kit (500 ft)...cat. #2135.54 Includes meter, rechargeable NiMH batteries, optical USB cable, power adapter 110/240V with power cord 115V US, two 500 ft color-coded leads on spools (red/blue), two 100 ft color-coded leads (hand-tied, green/black), one 30 ft lead (green), four T-shaped auxiliary ground electrodes, set of five spaded lugs, one 100 ft AEMC tape measure, DataView software, ground tester workbook CD, carrying bag for meter, carrying bag for kit, product warranty and registration card and a user manual. Accessories (Optional) 25Ω Calibration Checker............................................................................................... Cat. #2130.59 Tape Measure (100 ft)...cat. #2130.60 Test Kit for 3-Point testing (includes two 150 ft color-coded leads on spools (red/blue), one 30 ft lead (green), two 14.5" T-shaped auxiliary ground electrodes, set of five spade lugs, 100 ft tape measure and soft carrying bag)... Cat. #2135.35 Test Kit for 4-Point testing (includes two 300 ft color-coded leads on spools (red/blue), two 100 ft color-coded leads (hand tied green/black), four 14.5" T-shaped auxiliary ground electrodes, set of five spade lugs, 100 ft tape measure and soft carrying bag)... Cat. #2135.36 Test Kit for 4-Point testing (includes two 500 ft color-coded leads on spools (red/blue), two 100 ft color-coded leads (hand tied green/black), one 30 ft lead (green), four 14.5" T-shaped auxiliary ground electrodes, set of five spade lugs, 100 ft tape measure and soft carrying bag)... Cat. #2135.37 Ground Test Kit for 3-Point testing (Supplemental for 4-Point testing includes two 100 ft color-coded leads, one 30 ft lead (green), two 14.5" T-shaped auxiliary ground electrodes and soft carrying bag)... Cat. #2135.38 Technical Assistance (800) 343-1391 www.aemc.com 10 of 11

Contact Us United States & Canada: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 200 Foxborough Blvd. Foxborough, MA 02035 USA (508) 698-2115 Fax (508) 698-2118 www.aemc.com Customer Support for placing an order, obtaining price & delivery: customerservice@aemc.com Sales Department for general sales information: sales@aemc.com Repair and Calibration Service for information on repair & calibration, obtaining a user manual: repair@aemc.com Technical and Product Application Support for technical and application support: techinfo@aemc.com Webmaster for information regarding www.aemc.com: webmaster@aemc.com South America, Central America, Mexico, Caribbean, Australia & New Zealand: Chauvin Arnoux, Inc. d.b.a. AEMC Instruments 15 Faraday Drive Dover, NH 03820 USA (978) 526-7667 Fax (978) 526-7605 export@aemc.com www.aemc.com All other countries: Chauvin Arnoux SCA 190, rue Championnet 75876 Paris Cedex 18, France 33 1 44 85 45 28 Fax 33 1 46 27 73 89 info@chauvin-arnoux.com www.chauvin-arnoux.com Technical Assistance (800) 343-1391 www.aemc.com 11 of 11