Renewable energy & your co-op Installation procedures & guidelines for Farmers EC members YOU RE IN POWER.

Similar documents
Electrical District No. 3 SOLAR Q & A

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

Renewable Energy Interconnection Manual for Small Size Systems ( 10kW in NM 20kW in TX) Renewables and Emergent Technologies Group

Solar*Rewards Frequently asked questions system size and customer usage

Oncor Application for Interconnection of Distributed Generation

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

New Ulm Public Utilities. Interconnection Process and Requirements For Qualifying Facilities (0-40 kw) New Ulm Public Utilities

RENEWABLE ENERGY PROGRAM Step 1, Section 1 ENROLLMENT FORM FOR LEASED RESIDENTIAL AND SMALL COMMERCIAL PHOTOVOLTAIC AND WIND TURBINE SYSTEMS

Information Packet Kissimmee Utility Authority Customer-Owned Renewable Generation Interconnection And Net Metering Program

Should I Get a Solar Array for my House? The Regulations, Available Equipment, and Benefits Steven Johnson

Capture The Power of Photovoltaics. IEEE Power Engineering Society Meeting May 2005

Net Metering Service. Customer Information Package

Instructions for Completing Oncor s Interconnection Application For Solar PV Projects

A guide to rate information & requirements for the interconnection of a solar distributed generating system

NET METER REQUEST FORM

06/05/2018. COMMUNITY SOLAR OVERVIEW For Generation Owners and Subscribers

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

Renewable Net Metering Program Appendix ESD APX 001 1

24. SOLAR INCENTIVE PROGRAM II

Thomas Alston Director of Business and Policy Development. Presented By N. Scottsdale Rd, Suite 410 Scottsdale Arizona 85257

Frequently Asked Questions Trico Proposed Net Metering Tariff Modifications

Consumer Guidelines for Electric Power Generator Installation and Interconnection

2018 Customer generation rates

Montana Renewable Energy Association

2012 INSTALLERS MEETING UES INSTALLER S MEETING

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION

MARKET RATES UPDATE Paula Gold-Williams Cory Kuchinsky

Municipality Generator Interconnection Application Single Meter Application Part I

MCE Napa County Cleaner energy and lower rates. Honig Winery, Rutherford

DER101: Distributed Energy Resources basics. May 4, 2017

All of Texas Has Excellent Solar Resources. United States Solar Installed (as of mid 2013): 10 GW Germany Solar Installed (end of 2013): 35.

Michigan Renewable Energy Case Study

CUSTOMER OWNED SOLAR IN WISCONSIN

A 3-Year Case Study of a Residential Photovoltaic System with Microinverters

City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW)

Solar*Rewards Community Engineering Frequently Asked Questions For Garden Operators Minnesota

RE: Advice Schedule 45 Public DC Fast Charger Delivery Service Optional Transitional Rate REPLACEMENT PAGES

Long Island Solar Installer Workshop

FARM WASTE GENERATING SYSTEMS

SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & INTERCONNECTION AGREEMENT

This presentation was given as part of a workshop on November 14, Presenters were:

2018 Solar Home & Solar Share Home Program Manual

Solar*Rewards Frequently Asked Questions

Solar Power. Demonstration Site. Annual Performance Report 2017

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING

Economics of Integrating Renewables DAN HARMS MANAGER OF RATE, TECHNOLOGY & ENERGY POLICY SEPTEMBER 2017

40KW Solar System for Apple Sauce Co

Douglas Electric Cooperative Roseburg, Oregon

White River Electric Association, Inc. Net Metering Information & Service Requirements

REVISION NO.: 7 EFFECTIVE: 07/07/16

JACKSON ELECTRIC COOPERATIVE POLICY NO. 305

TILLAMOOK PEOPLE S UTILITY DISTRICT

JEA Distributed Generation Policy Effective April 1, 2018

HydroGenerations PROGRAM HANDBOOK

Michigan Public Service Commission Michigan Net-Metering Case Study

Umatilla Electric Cooperative Net Metering Rules

Analysis of Impact of Mass Implementation of DER. Richard Fowler Adam Toth, PE Jeff Mueller, PE

Northeastern Rural Electric Membership Corporation Columbia City, Indiana

SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board

Yield Reduction Due to Shading:

This presentation was given as part of a workshop on February 7, Presenters were:

Ameren Missouri. AMENDED Renewable Energy Standard Compliance Report Prepared in Compliance with 4 CSR

D.P.U A Appendix B 220 CMR: DEPARTMENT OF PUBLIC UTILITIES

New Hampshire Electric Cooperative (NHEC) Introduction to Net Metering

(2) Scope. 220 CMR applies to all Distribution Companies subject to the jurisdiction of the Department.

TERMS AND CONDITIONS

FITCHBURG GAS AND ELECTRIC LIGHT COMPANY NET METERING SCHEDULE NM

Bill Calculation for monthly GS < 50 kw - TOU Rate Component Description Metric Rate Volume Volume x Rate Charge

P.S.C.U. No. 50 Original Sheet No ROCKY MOUNTAIN POWER ELECTRIC SERVICE SCHEDULE NO. 136 STATE OF UTAH

SCHEDULE NO. ACG33 NET METERING SERVICE

Yield Reduction Due to Shading:

To: Honorable Public Utilities Board Submitted by: /s/ Barry Leska AGM Energy Resource Planning. From: Alan Hanger Approved by: /s/

ALZ Electrical Solar Consumer Guide

COMMUNITY SOLAR PROGRAM

FITCHBURG GAS AND ELECTRIC LIGHT COMPANY NET METERING SCHEDULE NM

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

MONTHLY PERFORMANCE DASHBOARD

Net Energy Metering and Interconnections. Community Solar in the District of Columbia

Noble County Rural Electric Membership Corporation

Community Solar FAQ. How does the Community Solar program work?

The International Cost Estimating and Analysis Association (ICEAA) Southern California Chapter September 9, 2015

NJ Solar Market Update As of 6/30/15

NJ Solar Market Update

REVISED 8/1/2018 SOLAR PHOTOVOLTAIC DISTRIBUTED GENERATION CUSTOMER GUIDELINES, APPLICATION & WGC INTERCONNECTION AGREEMENT

SOLARIZE HOBART. Solar. Simple. Together. Kathy Luther Director of Environmental Programs Northwestern Indiana Regional Planning Commission

SANTA CLARA CITY RENEWABLE NET METERING & INTERCONNECTION AGREEMENT

Thank you for requesting information on our utility auditing services!

Residential Time-of-Day Service Rate Schedule R-TOD

Solar Net Metering and Billing FAQ

The brand you can trust.

a) The 2011 Net Metering and Buyback Tariff for Emission Free, Renewable Distributed Generation Serving Customer Load

Frequently Asked Questions

Delaware Electric Cooperative. Solar: What You Need to Know

Now There is a New Source of Energy Independence Your Backyard.

December 2018 RenewableGenerations Monthly Report

Lassen MUD PV BUYDOWN PROGRAM Photovoltaic Systems Guidelines

My Home Solar PhotoVoltaic (PV) System 2010 through 2017 How s It Doing?

Graph #1. Micro-Generation Generating Units in Alberta 20

Presented by Eric Englert Puget Sound Energy September 11, 2002

Transcription:

DISTRIBUTED GENERATION Renewable energy & your co-op Installation procedures & guidelines for Farmers EC members IPORTANT: Before construction and build of your distributed generation system, read this document throughly and then contact Farmers EC at: 903 455 1715

There are a few requirements that Farmers EC has in place in order to maintain safety and reliability for our members and personnel when installing a Distributed Renewable Generation (DRG) system. After the system is installed, a Farmers EC representative will perform an inspection on the system. All the following requirements must be met. Requirements checklist: The Agreement for Interconnection contract has been completed and signed by the owner of the DRG system. A one-line drawing and system layout diagram has been submitted to Farmers EC. A meter socket has been installed on the output of the DRG system (Refer to the Farmers EC Sample DRG One-Line and Sketch). The DRG meter socket has been wired to have DRG production flow from bottom-up through the meter. (Refer to the Farmers EC Sample DRG One-Line and Sketch.) A visible lockable labeled disconnect (VLLD) device that has a visual break has been installed within ten feet of the utility billing meter. If not, a site directory placard indicating the location of the VLLD has been placed on the ember s equipment beside the Cooperative s billing meter. The inverter is UL 1741 and IEEE 1547 compliant. Systems more than 15kWdc will require and additional engineering study. A good rule of thumb is to make sure the DRG system does not exceed 110% of your two-year historic maximum demand. Contact Farmers EC before you begin construction and request a usage history report.

What happens to the energy I generate? The energy that is generated by your DRG system will flow through Farmers EC Distributed Generation (DG) output meter and into your home. Your home will absorb all of the energy it needs from your DRG system and pull the rest from Farmers EC grid (in-flow). If your DRG system produces more energy than your home needs, the excess will flow back into Farmers EC grid (out-flow). This outflow can be seen on the Farmers EC billing meter. Farmers EC Grid Billing eter 1 kw (In-flow) 5 kw ember s Facility EXAPLE: 6 kw Continuous Load DRG System (Solar / Wind) 5 kw DG Output eter FIGURE 1. ember s load is greater than DRG production If the example in Figure 1 held true for 1 hour: Total energy consumed by the member = 6 kwh Total energy produced by the DRG system = 5 kwh Total energy supplied by the Cooperative (In-flow) = 1 kwh

Farmers EC Grid Billing eter 1 kw (Out-flow) 5 kw ember s Facility EXAPLE: 4 kw Continuous Load DRG System (Solar / Wind) 5 kw DG Output eter FIGURE 2. ember s load is less than DRG production If the example in Figure 2 existed for 1 hour: Total energy consumed by the member = 4 kwh Total energy produced by the DRG system = 5 kwh Total energy supplied to the Cooperative (Out-flow) = 1 kwh Who can I call to install a DRG system? Farmers EC does not recommend any particular installer. Contact Farmers EC and ask for a list of solar companies and contractors that you can call. The list you get will show all the solar companies that have done work for our embers. Please keep Farmers EC informed if you decide to move forward with a DRG system as there are certain procedures that must be followed.

Why does my inverter say it has produced a different amount than the Farmers EC meter? While it is nice having your solar inverters tell you how much they have produced, many of them are not accurate enough for billing standards. This is one of the reasons why we provide a DG output meter to you at no additional cost. Utility grade meters have a less than 0.5% variance in accuracy, whereas some inverters can have as high as a 10% error in metering. Why does my DRG system produce different amounts each month? DRG systems rely on many different factors when it comes to system production. For example, if a month was particularly rainy, then there were fewer days of sunshine which means less production from your solar panels. Is there any shade on your panels? Sometimes leafs and other debris can land on your solar panels, reducing total production. Solar irradiance can also be quite different with the changing months. With the approach of the winter solstice, the days become shorter and the nights become longer. These, amongst many other factors, all play a role in your solar production. Below is an example of the monthly output trend. You can usually expect a bell curve where system performance is best during summer months and least during winter months. This graph reflects the pvwatts.nrel.gov estimate output a 5 kwdc system would produce in Greenville, TX. It is important to note that this is an estimate and you should not base your calculations solely on this graph. 800 AC Energy (kwh) 700 600 500 582 636 710 620 653 611 549 635 400 300 378 411 402 436 200 100 0 JAN FEB AR APL AY JUN JUL AUG SPT OCT NOV DEC FIGURE 3. PVWatts estimated performance of a 5kWdc system in Greenville TX

Why is the received energy on my Billing eter different than my DG Output eter? When your DRG system produces energy, it will be used to power your facilities. When your solar system produces more energy than your facility needs, the excess will flow into the grid (out-flow). Since your facility is consuming a portion of the energy generated by your DRG system, your billing meter will only be able to see the excess. In the example below, your billing meter will show that the solar generation (REC register in the meter) flowing to the grid was 300 kwh and your DG Output eter will show 1000 kwh (REC register in the meter). Farmers EC Grid Billing eter 300 kwh Reg 2 (Out-flow) ONTHLY EXAPLE: The member s DRG system generated 1000 kwh of energy. 300 kwh was sent to the grid. The member s facility really used 1500 kwh, but Farmers EC only saw 800 kwh as in-flow. 800 kwh Reg 1 (In-flow) 1000 kwh 700 kwh DRG System (Solar / Wind) Produced 1000 kwh DG Output eter ember s Facility 700 kwh + 800 kwh = 1500 kwh FIGURE 4. The received (REC) register on the meters will see different portions of the overall power production

Does FEC buy my power?/how will my bill change? Farmers Electric purchases all power sent to the grid (out-flow) at the current year s avoided cost rate. You can find the rate of avoided cost on the Public Utility Commision of Texas (PUCT) website which ERCOT publishes each year. Below is an example of how a usage bill might look with a solar/drg system installed. https://www.puc.texas.gov/industry/projects/electric/38578/38578.aspx Farmers EC Grid Billing eter 300 kwh Reg 2 (Out-flow) 1000 kwh 800 kwh Reg 1 (In-flow) 700 kwh DRG System (Solar / Wind) Produced 1000 kwh DG Output eter ember s Facility 700 kwh + 800 kwh = 1500 kwh EXAPLE: Assuming a one-month billing cycle, the current FEC rate of electricity being $0.108/kWh, and the current Avoided Cost rate being $0.038/kWh. Without Solar / DRG ember s Facility Usage = 1500 kwh Energy Supplied by FEC = 1500 kwh Usage Cost: (1500 kwh) x ($0.108) = $162 Basic Charge = $15 TOTAL FEC BILL: $162 + $15 = $177 With Solar / DRG ember s Facility Usage = 1500 kwh Energy Supplied by FEC = 800 kwh Usage Cost: (800 kwh) x ($0.108) = $86.40 Basic Charge = $15 DG Facility Charge = $10 Excess Solar Production (out-flow) = 300 kwh Out-flow Credit = (300 kwh) x ($0.038) = $11.40 TOTAL FEC BILL: $86 + $15 +$10 - $11.4 = $100 Total Bill Usage Reduction = $77 The size of the Solar/DRG system in this example would be roughly 9,000 watts (W) or 9 kilowatts (kw).

Solar Rates and Charges During each billing period, for power produced in excess of on-site requirements, as metered by the Cooperative billing meter, the Cooperative will purchase such excess production at Avoided Cost. Avoided Cost means the rate in dollars per kilowatt hours ($/kwh) as calculated by ERCOT and published by the Public Utility Commission of Texas (PUCT) yearly. Follow the link below to see the current year s avoided cost rate. https://www.puc.texas.gov/industry/projects/electric/38578/38578.aspx All Solar/DG facilities will be billed a monthly DG facility charge in addition to their current basic ember charge. Refer to the table below to see the DG Facility charge amounts. Size of Installation For Solar/DG Facilities with an Installed Capacity or Nameplate Rating of less than 50 kw For Solar/DG Facilities with an Installed Capacity or Nameplate Rating of 50 kw or more, up to less than 1 W onthly DG Facility Charge $10 per month per facility $100 per month per facility

APPENDIX A: Installer Requirements NOTE: A system line drawing/diagram along with the Agreement for Interconnection must be submitted before installation. 1. Farmers EC requires a meter socket to be installed on the output of the Distributed Renewable Generation (DRG) system. The meter must be wired so that energy production flows bottom-up through the meter. The system will not be approved if the meter socket is not wired in this fashion. A Farmers EC meter will be provided and installed upon system approval at no cost. This is referred to as the DG Output eter. 2. A Visible Lockable Labeled Disconnect (VLLD) Switch must be installed and located within 10 ft. of the Utility Billing eter. If the VLLD cannot be within 10 feet, a placard signifying the VLLD s location will be allowed. 3. Appropriate signage/warning labels must be in place signifying that there is on-site generation. Utility (Farmers Electric Coop) 1 NOTE: Wire the DG output to the bottom lugs of the meter base. Residential Service Utility Billing eter ain Service Panel (For Residential Loads) 3 NOTE: Visible disconnect in close proximity to meter. 2 Visible Lockable Labeled Disconnect (With External Handle) EXAPLE: Placard Language CAUTION Generation Utility AC Disconnect DG Output eter Inverter Indicate Source (PV panels, batteries, etc.) Solar/DG Generation

How big of a DRG system should I put in? The size of the solar system should be specific to your own usage needs. You will want to take many things into consideration when choosing the size of your solar system. Contractors can help with the process, but it s good to know how to size a system yourself. STEP 1: Contact the Cooperative and ask for a 12-month usage history, you can use this to gauge your consumption trends. Look at the usage (kwh) and the demand (kw) values for each month. STEP 2: You can use sites like pvwatts.nrel.gov to model a system. It will give you a monthly estimate on how much a DRG system of any given size will produce based on your geo location and other variables. STEP 3: Compare the monthly kwh data from steps 1 and 2 and customize your system to your needs. STEP 4: If the system is larger than 15 kwdc, verify that the size of the DRG system does not exceed 110% of your maximum historic demand. 2018 Renewable Energy Update Effective January 1, 2018 1: Farmers EC will no longer offer the 1:1 monthly net metering rate to new renewable installation accounts. All embers who have installed a system prior to January 1, 2018 will be able to remain on the net metering plan or opt-into the new avoided cost buyback structure. 2: All new Distributed Renewable Generation (DRG) systems (e.g. solar and wind) will now be administered under an avoided cost buyback structure. Any excess generation (out-flow or overflow) that goes onto the grid will be purchased at the Avoided Cost rate that is calculated yearly by ERCOT and posted publicly by the PUCT. Refer to the link below for the posted avoided cost rates. https://www.puc.texas.gov/industry/projects/electric/38578/38578.aspx 3: A new Interconnection Agreement will be in use starting January 1, 2018. The old Agreement will no longer be accepted. 4: The technical requirements for installation have not changed. 5: Farmers EC provides a rebate of up to $500 for renewable energy systems that are 50kW or less.