New Generator Products

Similar documents
Generator. Jason S DiSanto. 6B Users Conference San Antonio, TX June 19-22, 2017

Power-GEN Middle East

Turbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators

Excitation system is of Static Silicon Excitation System, including excitation transformer, thyristors, and AVR.

F-class OpFlex controls advancements

GE Power & Water Power Generation Services

Technical Manual Index March 1, 2018

Pressurized Air Cooled Generators

World s Largest Air-cooled Turbogenerator in operation

POWERING EVERYONE. Unlocking the Potential JULIO MESTRONI, APPLICATION ENGINEERING LEADER

TURBO GENERATORS BEST QUALITY FOR THERMAL POWER PLANTS

New Robotic Technologies for Inspecting Two Pole Electric Generators while the Rotor Remains in Place

CFM Technology. realizing the promise 50% LOWER NOX EMISSIONS. ANOTHER LEAP FORWARD FOR LEAP TECHNOLOGY.

Extended requirements on turbogenerators

Development and Performance Evaluation of High-reliability Turbine Generator

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

Basics of Paralleling

Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities

Avio Aero. Collaborative network established in Clean Sky: a success story

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Design Data 3.2 Standard Accessories 3.3 Tolerances

CONTENTS 1 GENERAL 2 STANDARDS. 3 TECHNICAL FEATURES 3.1 Basic Technical Data 3.2 Standard Accessories 3.3 Tolerances

Generators for the age of variable power generation

ECEg439:-Electrical Machine II

LEAP-X Program Update

Inspection Testing Repair

1997 Volvo 850 GLT. Fig. 2: Removing Drive Shaft, Engine Mount Bolt & Torque Arm (5-Cylinder) Courtesy of VOLVO CARS OF NORTH AMERICA.

B kv Gas-insulated Substations

High-voltage motors TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION

Brochure. Wind turbine generators Reliable technology for all turbine applications

Electrical Theory. Generator Theory. PJM State & Member Training Dept. PJM /22/2018

Cutting-edge technologies backed by a century of experience

CF34-8 Technical Manual Index July 1, 2018

Brochure. Synchronous generators for diesel and gas engines Proven generators reliable power

Marine generators Proven generators for reliable power on board

1. SPECIFICATION. Altitude of motor installation. Information: Resistance and temperature specifications of the PTC thermistor / posistor/.

MECHANICAL INTEGRITY CHECKING OF GENERATOR STATOR OVERHANG BY NATURAL FREQUENCY MEASUREMENT

A Homopolar Inductor Motor/Generator and Six-step Drive Flywheel Energy Storage System

Design specifications

Safety drying ovens with expanded temperature range

CF34-10A Turbofan Technical Manual Index November 1, 2018

Sullair: An Industry Leader

Reliance Electric Super RPM Large Variable Speed DC Motors: HP B500-B1600 Frame RPM

COMPONENT IDENTIFICATION

Safety drying oven with expended temperature range

Modular Standardized Electrical and Control Solutions for Fast Track Projects

2 Pole 1222MVA Turbo-Generator & 4 Pole 1690MVA Turbo-Generator

Contact us. Catalog Low voltage generators for diesel and gas engines Industrial Marine applications - series Standard series

COMPARING SLOTTED vs. SLOTLESS BRUSHLESS DC MOTORS

Pump Specifications. D3648LSG, D3648LSGX Series Omnivore 2HP Duplex Grinder Packages LITERS PER SECOND

GE Energy. Variable Frequency Transformers Grid Inter-tie

Ultra Series. Vertical Pump Motors HP. Durability, Reliability and Efficiency at the Heart of Industrial Operations

Remy HVH250 Application Manual Remy HVH250 Application Manual

LEAP - Life Expectancy Analysis Program For Electrical Rotating Machines. Marcio Gennari ABB Brazil Automation Products Machines Service Osasco

Teepak Totally Enclosed Tube Ventilated High Voltage Induction Motors. A Regal Brand.

SECTION AXIAL HVAC FANS

Application Notes. Calculating Mechanical Power Requirements. P rot = T x W

Diesel generator set QSK23 series engine

RENTAL DIESEL GENERATOR SET

Small step, big impact: Energy efficiency and dynamic performance

AIR COOLED RECTIFIER SPECIFICATION S-50-A

PROBLEMS WITH NEWER GENERATORS

Landmark Rooftop Packaged Units

GSG Diffuser Style Barrel Pump ISO (API 610) Type BB5

High Voltage Generators. TM21-TG Series. 2-Pole Air Cooled Turbine Generator Up to 80,000 kw (107,000 HP)

Sullair: An Industry Leader

Innovative Axial Flux Air Cored Permanent Magnet Generator suitable for Slow, Medium Speed and Direct Drive Wind Turbines

CF34-1A/-3A/-3A2 Turbofan (Business Jet) Technical Manual Index September 1, 2018

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

SIGENTICS HV Series S-modyn

LITERS PER MINUTE GALLONS PER MINUTE

Series E4F E5F

Configuration of a generator

Standardmotoren Standard motors

CT7 Turboprop Technical Manual Index February 1, 2018

A. Motors shall be designed, built, and tested in accordance with the latest revision of the following standard documents.

AIR COOLED CHILLERS WATER COOLED CHILLERS

Field coil From Wikipedia, the free encyclopedia

Safety drying ovens. Advantages: Areas of application: FDL series 115

Heating oven with mechanical control

Electrical Machines -II

INTER PLANT STANDARD STEEL INDUSTRY

The information contained in this document is the property of Meggitt Sensing Systems and is proprietary and/or copyright material.

CROMPTON GREAVES LTD.

ODP SERIES PREMIUM INDUSTRIAL OPEN DRIP PROOF MOTORS C280M to C355LB Frame. Australian Version October 2013

Hybrid DC-DC-AC Main Drive for ILVA, Taranto Finishing Mill

DATA & FACTS Unit Heaters MultiMAXX HB. Quick Selection and Fast Delivery

HeliFlow Industrial Series. Positive Displacement Blowers & Vacuum Pumps

SKF Explorer spherical roller bearings Optimized for superior field performance

Transforming Transforming Advanced transformer control and monitoring with TEC

BRUSHLESS EXCITERS FOR TURBINE GENERATORS

ROBATIC ROBA -quick ROBA -takt. Reliable coupling and braking.

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Introducing the TM /

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

CHAPTER 4 HARDWARE DEVELOPMENT OF DUAL ROTOR RADIAL FLUX PERMANENT MAGNET GENERATOR FOR STAND-ALONE WIND ENERGY SYSTEMS

VW Arc-Weldable Strain Gauge

Gerotor pump, fixed displacement volume

Chart, Inc. Data Sheet 2s241K Cryocooler

Publication No.: PSG

A I R C O M P R E S S O R S R O L L A I R E

Transcription:

GE Power and Water New Generator Products Generator User s Conference Anthony Arrao John Yagielski General Electric Company Schenectady, NY USA November 2015 copied or distributed in whole or in part, without prior permission of the copyright

Generator Product Overview copied or distributed GE in whole Restricted or in part, - Distribute without prior to named permission individuals of the copyright only.

GE Generator Portfolio H33 (7FH2) H35 (7FH2B) H53 (324) H55 (330) H73 (390H) H75 (450h) Legacy Generator Products Modular Generator Products W8X Water-cooled H8X H2-cooled H6X H2-cooled 7F.0 4 9F.03 9F.05 SS 9F.05 9F.03 SS 7HA.01 7F.05 7HA.02 9HA.01 50 Hz 60 Hz 7HA.02 9HA.02 SS 50 Hz 9HA.02 SS 60 Hz 9HA.02 SS 60 Hz 50 Hz 0 100 200 300 400 500 600 700 Generator Output (MW) copied or distributed in whole or in part, without prior permission of the copyright 3

Modular Generator Philosophy H8X) (H6X and 470 MW 510 MW 550 MW H6X 6 leads up or 6 leads down GTE for Leads-up 1 meter centerline height support with integral feet Direct fixator support 4 post vertical coolers in fan inlet bay No lower frame extension (LFE) Reach-in Dog-house style collector compartment 590 MW H8X 3 leads up / 3 leads down Unit-mounted GNTE only 4 copied or distributed GE in Restricted whole or in - part, Distribute without to prior named permission individuals of the copyright only.

Generator Overview Benefits Key features Highly efficient Reduced site assembly Enhanced cooling capability Improved serviceability Increased reliability Top line lead exit 4 post vertical coolers One piece frame construction for simplified installation Extended foot / fixator support for maintenance/ serviceability Modular gas, seal oil and stator cooling water systems Stator water cooling system with integrated monitoring Packaged static excitation and static starter Fieldbus technology 50% less site wiring Sized for robotic air-gap MAGIC* inspection to avoid generator moves Extended Foot (double end drive) * Trademark of General Electric Company 5 copied or distributed in whole or in part, without prior permission of the copyright

Double End Drive Generator In The Middle Rotor Removal Extended Feet Frame Blocking Full generator lift Rollers, guide, axe and push jack Stator relocation by heavy lift rigging integrated into plant design Full lift capacity crane not required copied or distributed in whole or in part, without prior permission of the copyright 6

Heritage and Experience Hydrogen and Water Cooled Experience profile Units shipped Operating hours GE water-cooled generators 589 153,160,000 - SS CC water-cooled 33 4,237,000 Phosphorus free braze bars 132 6,430,000 GE hydrogen-cooled generators 3009 797,316,600 - H73/ H75 improved end winding support system 76 5,052,600 Radial-cooled C-coil fields 1170 104,419,900 Proven technology for service reliability copied or distributed in whole or in part, without prior permission of the copyright 7

Generator Features copied or distributed GE in whole Restricted or in part, - Distribute without prior to named permission individuals of the copyright only.

Stator Winding and Core 3 phase, 2 or 3 circuit configuration Class F 155(C) insulation End windings Connection rings Tetraloc* end-winding support Encapsulated monolithic structure for minimum maintenance - 500+ units in service Leak-free, corrosion-proof stator bar clip (H2O-only) Image is for water-cooled bars support system same for conventionally cooled bars Silicon steel core Iron clamping flange with ventilated flux shield Reliability & availability through service proven configurations copied or distributed in whole or in part, without prior permission of the copyright * Trademark of General Electric Company. 9

Stator Slot Support System Slot support restraint accomplished by top and side ripple springs; tapered wedge and slide H2O-cooled windings include molded conforming filler material Provides radial and tangential restraint while allowing axial expansion copied or distributed in whole or in part, without prior permission of the copyright 10

Rotor and Field Winding Single layer C-coil winding Direct radial-flow cooling Axial flow fans Tilt-pad bearings Spring-loaded coil slot amortissuers for low-speed static start capability 2 pole rotor Outboard terminal stud Robust architecture upgraded with outboard terminal stud from LSTG fleet copied or distributed in whole or in part, without prior permission of the copyright 11

Stator Core Isolation System Isolates stator core from frame structure Reduces forces transmitted to foundation Reduces stator frame vibration Reduce web plate stress Reduce acoustic noise Bolts Bolted springbar design for superior core vibration isolation copied or distributed in whole or in part, without prior permission of the copyright 12

H2 Generator Cooling Circuit Once through ventilation optimized for uniform cooling without air gap baffling copied or distributed in whole or in part, without prior permission of the copyright 13

Packaging Ribs integrated to the bearing cap Increased axial clearance for removal Field supported by sling with upper and lower half end shield in place Double tilt-pad bearing with dual insulation Endshield engineered for robust operation & maintainability copied or distributed in whole or in part, without prior permission of the copyright 14

Collector and Brush Rigging Common features: Cooling-air path is fully above floor, including inlet and exhaust silencing (no flow through foundation and no customer ducting required) Junction boxes for heater and instrumentation are external (easy access) DC leads are external (connect with bus bar or cables) Rated IP54W New GE brush holder Integral GT turning gear Double-end drive Single-end drive Standardized collector design for Single & Double End Drive copied or distributed in whole or in part, without prior permission of the copyright 15

New Proprietary Brush Holder Technology Enhanced Features Lightweight aluminum construction with durable, hard, anodized surface coating Double-wide holder for faster brush changing Integral, safe, insulated changing handle Rotated handle and large locking pin are clear indicators of complete installation No tools required for replacement of brush or springs Taller box to avoid hang-ups, reduce selectivity, and extend brush life Extensive validation testing at GE and H33(7FH2) site New holder optimized for maintenance & longer life copied or distributed in whole or in part, without prior permission of the copyright 16

Seal Oil System Automated system control eliminate need for human intervention Digital bus communications added system diagnostics and controls Continuous real time monitoring 2015 General Electric GE Proprietary Company. Information Class All Rights Reserved. This III (Confidential) material may not be copied or distributed in whole or in part, without prior permission of the copyright Export Controlled U.S. Government approval is required prior to export from the U.S., re-export from a third country, or release to a foreign national wherever located. 17

Stator Cooling System GE High Dissolved Oxygen System Eliminates vacuum treating requirements Reduces operating cost with lower auxiliary loads Constant Flow/Ambient Following Fixed flow rate for minimal operator interface needs Ambient following temperature control reduces auxiliary cooling water demand, follows capability curve Reliability Enhancements Duplex strainers for on-line maintenance 100% redundant cooling pumps and heat exchangers Integral Stator Leak Monitoring System (SLMS HP*) for online detection of stator bar leaks Fully integrated with Mark VIe control system Digital bus communications for total system diagnostics and controls Alarm pop ups for recommended inspection/actions Modernized with on-line maintenance & monitoring Operability for combined-cycle operation * Trademark of General Electric Company copied or copied or distributed distributed in whole in whole or in part, or in without part, prior without permission prior permission of the copyright of the copyright 18

Validation and Test copied or distributed in whole or in part, without prior permission of the copyright

Validation GE has invested $22.5MM into labs and test facility Generator armature development lab Automated retaining ring assembly Connection ring insertion fixture Generator endurance test stand 2007-2009 2010 2011 Non-metallic and materials labs Insulation systems development Generator armature development lab Bar force limits Slot component testing Repair technology COE and MFG tooling Field rewind process automation full-scale validation New repair center Retaining ring tooling and coil cleaning Connection ring insertion fixture cycle and quality Generator validation and testing facility Full system thermal cyclic-duty and endurance testing Rigorous component level testing and materials validation Multi-year investment in validation capability for new products 20 GE Title or job number 11/18/2015

Validation Progression * Trademark of General Electric Company Thermal cycling & endurance to simulate 1 st year operation copied or distributed in whole or in part, without prior permission of the copyright 21

Factory Running Tests Open circuit up to 125% rated voltage Short circuit up to 120% rated current Heat runs with varying cold gas and H2-pressure Sudden short circuits up to 70% voltage Deceleration tests with: Varied mass and support stiffness Purposeful rotor unbalance Ventilation and Acoustic Surveys Negative and zero sequence reactance Thermal cycling and Endurance runs: 60+ stop / start cycles 350+ hours of overload operation Over 1500 additional validation sensors: Traditional and fiber-optic thermocouples Piezo and fiber-optic accelerometers Stator slot vibration Voltage / current probes and search coils Pressure and velocity probes Comprehensive running test for verification & characterization copied or distributed in whole or in part, without prior permission of the copyright 22

W86 and H84 Factory Test Result Summary Mechanical performance Rotor and frame vibration levels well below operating limits End-winding and connection ring vibration levels well within fleet operating experience No visual indications of change to the stator winding due to: 60+ thermal cycles 350+ hours of endurance runs Sudden short circuit tests up to70% Electrical / Thermal performance Short circuit ratio exceeded expectation Rotor and stator winding temperatures below class B observable limits Core end iron temperatures significantly below fleet experience Back-of-core voltages well below operational limit Overall losses 4 to 5% lower than expected Performance of first 2 units exceeded expectations. H65 60Hz & H84 60Hz validation ongoing copied or distributed in whole or in part, without prior permission of the copyright 23

On-Line Monitoring copied or distributed in whole or in part, without prior permission of the copyright

Monitoring and Diagnostics Available modules Advanced Monitoring Systems Auto Shorted Turn Analysis Stator Leak Monitoring System High Performance (H20 only) Flow Circuit Analysis (H2O only) Enhanced Partial Discharge Analysis End winding Vibration Monitor Generator Health Monitor (GHM) (knowledge based analysis of data) Collector Health Monitor copied or distributed in whole or in part, without prior permission of the copyright 25

Summary copied or distributed in whole or in part, without prior permission of the copyright

Summary GE s new modular generators supersede legacy products 50Hz and 60Hz applications Single-shaft and Multi-shaft Honed for combined cycle applications - Cyclical operation - Maintenance coordinated with prime mover Utilize proven technology for reliable operation Increased online monitoring capability GE is committed to full life cycle performance and quality 27 copied or distributed in whole or in part, without prior permission of the copyright

GE Power and Water 2015, General Electric Company. GE Proprietary Information - The information contained in this document is General Electric Company (GE) proprietary information. It is the property of GE and shall not be used, disclosed to others or reproduced without the express written consent of GE, including, but without limitation, in the creation, manufacture, development, or derivation of any repairs, modifications, spare parts, or configuration changes or to obtain government or regulatory approval to do so, if consent is given for reproduction in whole or in part, this notice and the notice set forth on each page of this document shall appear in any such reproduction in whole or in part. The information contained in this document may also be controlled by the US export control laws. Unauthorized export or re-export is prohibited. All relative statements are with respect to GE technology unless otherwise noted.