GREEN REFRIGERANT R-410A

Similar documents
GREEN REFRIGERANT R-410A

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

THE WALL-MOUNT AIR CONDITIONERS - WA (60HZ)

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

THE WALL-MOUNT QUIET-CLIMATE HEAT PUMPS

Electric Heat Strips: Features an automatic limit and thermal cut-off safety control. Heater packages can be factory or field installed.

The Wall-Mount Step Capacity Gas/Electric - WG*S Series Integrated Part Load Value (IPLV) Efficiency Up to 15.6 BTU/WATT.

THE WALL-MOUNT STEP CAPACITY HEAT PUMPS Integrated Part Load Value (IPLV) Efficiency Up To 15.0 BTU/WATT

GREEN REFRIGERANT R-410A

V High Efficiency Series

THE WALL-MOUNT GAS/ELECTRIC - WG-SERIES

D M S 760 C01 A A 1 1

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

CB29M. Multi Position 60 HZ A I R H A N D L E R S. 3 to 5 Tons Optional Electric Heat 5 to 30 kw CB 29 M 41 1 E N G I N E E R I N G D A T A

Product Data. Features/Benefits. OMNIZONE 50XCR06-24 Remote Air-Cooled Indoor Self-Contained Systems with PURON Refrigerant (R-410A)

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

CHP

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

M-SERIES MHP4 MODEL NUMBER GUIDE 3 M HP F P 1 ELECTRIC HEAT PUMP PACKAGED UNITS REVISION CODE

PHR5. Product Specifications

ELITE SERIES R-410A Ready - Multi-Position

WALL MOUNTED PACKAGE AIR CONDITIONER REPLACEMENT PARTS MANUAL. Models: WA381 WA424D WA423 WA485D WA484 WA491 WA602 WA605 WA605D.

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

P3RC-12 SEER 2 Ton thru 4 Ton Units Cooling: 23,800 to 48,000 Btuh

GV Series High Efficiency Geothermal/Water Source Packaged Step-Capacity Heat Pump R-410A

Product Data. Features/Benefits. Omnizone 50XCA06-14 Air-Cooled Indoor Self-Contained Systems with Puron Refrigerant (R-410A) 5 to 12 Nominal Tons

PCB COMMERCIAL SERIES

Cooling Capacity Tons (kw) 024 = 2 (7.0) 030 = 2.5 (8.8) 036 = 3 (10.6) 048 = 4 (14.1) 060 = 5 (17.6)

Product Data. Features/Benefits 50JS SINGLE-PACKAGED HEAT PUMP 50 HZ UNITS 7 TO 18 KW (2 TO 5 NOMINAL TONS)

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

AIR HANDLERS RBHM- SERIES AIR HANDLERS AND FAN COIL UNIT

I-TEC TM I30H-I60H 2-Stage Compressor High Efficiency Air Source Heat Pumps

GP7RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner, Single Phase WARRANTY

GQ6SD Series. Single Packaged Heat Pump 13 SEER, R-410A 2-5 Ton Units TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS WARRANTY

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioning, 13 SEER. 3, 4, 5 Ton Units

GP5RD Series. Single Packaged Air Conditioner, Single Phase TECHNICAL SPECIFICATIONS

AFGP12B. Features. Efficiency: 12 SEER 80% AFUE. Warranty: 10-year limited compressor 10-year limited heat exchanger 5-year limited components

TECHNICAL SPECIFICATIONS

Q6SD Series 13 SEER, Three Phase, Packaged Heat Pump with R-410A 3-5 Ton Units

S/T Ratio. Input BTU/h

engineering guide Air-Cooled Self-Contained Units

REPLACEMENT PARTS MANUAL

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.

Models: WA182, WA242. Contents. Control Panel. Blower Assembly. Bard Manufacturing Company, Inc. Bryan, Ohio 43506

Tons BTU/h S.E.E.R* E.E.R** HSPF

ROOF TOP (SERIES SR) 10.8 TO 103 KW 37,000 TO 351,000 Btuh

GQ3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS

P6SD Series Single Packaged Air Conditioning, 13 SEER - R-410A 3, 4, 5 Ton Units

AIR HANDLERS UBHN- SERIES AIR HANDLERS AND FAN COIL UNIT PRELIMINARY NOT FOR DISTRIBUTION

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINT CERTIFIED ROOF CURB DIMENSION PRINTS

REPLACEMENT PARTS MANUAL

Operating Net Capacity BTU/h. Input BTU/h Efficiency. lbs (kg) PGR524040KGP* 23, ,000/26, /8 x 47 x 31-7/16

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

13 SEER Light Commercial 3 Phase

CSA6. Product Specifications. SoftSound SXC 2600

P7RD-A Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

PHF SERIES THREE PHASE CONVERTIBLE SINGLE PACKAGE HEAT PUMP

Q7RE Series Single Packaged Heat Pump, Single Phase

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

P7RE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Air Conditioner

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

P4SD Series Single Packaged Air Conditioning, 13 SEER 3, 4 and 5 Ton Units

PACKAGE AIR CONDITIONERS

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

GPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H

AIR HANDLERS AIR HANDLERS. RHPN- SERIES 18 SEER featuring Earth-Friendly R-410A Refrigerant. Features

P5RF Series Rev "A" Single Packaged Air Conditioner Single Phase

GT Series High Efficiency Geothermal/Water Source Step-Capacity Heat Pump R-410A

R6GF Series Rev B TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Gas/Electric Units Two-Stage Heat/Cool with Variable Speed Blower

TECHNICAL GUIDE FLEXIBLE LIGHT COMMERCIAL UNIT CHAMPION SERIES (WORLD 50 HZ) SINGLE PACKAGE COOLING UNITS D1EB036, 048 AND 060 3, 4 & 5 NOMINAL TONS

N4A6. Product Specifications

AFAIR12B. Features. Efficiency: 12 SEER. Warranty: 10-year limited compressor 5-year limited parts. Capacity: 1-1/2 to 5-ton.

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

CBH17-95V Horizontal Unit CB V

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.

CONVERTIBLE SINGLE PACKAGE HEAT PUMP

P8SE Series. 14 SEER, Three Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Q6SP Series Rev A TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 7.5 and 10 Ton Packaged Electric Heat Pump Units with R-410A 11.

GQ4SD Series. Single Packaged Heat Pump 13 SEER TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

AIR HANDLERS RBHC- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

GR4GC Series Single Packaged Gas/Electric Units

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

AIR HANDLERS RBHK- SERIES HEAT PUMP AIR HANDLERS AND FAN COIL UNIT

The Premium Quality Fan Coil Units for Horizontal Application Hydronic or Electric Heat

SUNLINE 2000 (WORLD 50 HZ)

Bosch BOVA Split System Heat Pump

GQ4 Series TECHNICAL SPECIFICATIONS. Three Phase Single Packaged Heat Pump (12 SEER) GQ4SC-036C GQ4SC-048C GQ4SC-060C FEATURES AND BENEFITS

P6SD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

GR4GA Series Single Packaged Gas/Electric Units

Transcription:

s J7L to JL. to Ton (, to, Btuh) Left ide Control Panel Hz olair Wall-Mount ir Conditioner is a self contained energy efficient system, which is designed to offer maximum indoor comfort at a minimal cost without using valuable indoor floor space or outside ground space. This unit is the ideal product for versatile applications such as: new construction, modular offices, school modernization, telecommunication structures, portable structures or correctional facilities. Field installed accessories are available to meet specific job requirements. Engineered Features WLL-MOUNT IR CONDITIONER -. EER, (HZ) with LEFT IDE CONTROL PNEL GREEN REFRIGERNT R- luminum Finned Copper Coils: Grooved tubing and enhanced louvered fin for maximum heat transfer and energy efficiency. Twin Blowers: Move air quietly. Most models feature multispeed blower motors providing airflow adjustment for high and low static operation. Motor overload protection is standard on all models. ir Conditioner Compressor: Compressors eliminate need for crankcase heater. tandard on ½ to ton. R- Refrigerant: Designed with R- (HFC) nonozone depleting refrigerant in compliance with the Montreal protocol and EP requirements. Phase Rotation Monitor: tandard on all phase scroll compressors. Protects against reverse rotation if power supply is not properly connected. Galvanized Gauge Zinc Coated teel Cabinet: Cleaned, rinsed, sealed and dried before the polyurethane primer is applied. The cabinet is handsomely finished with a baked on textured enamel, which allows it to withstand hours of salt spray tests per TM B7-. Foil Faced Insulation: tandard on all units. Full Length Mounting Brackets: Built into cabinet for improved appearance and easy installation. NOTE: Bottom mounting bracket included to assist in installation. Electrical Components: re easily accessible for routine inspection and maintenance through a left side, service panel opening. Features a lockable, hinged access cover to the circuit breaker or toggle disconnect switch. Electric Heat trips: Features an automatic limit and thermal cut-off safety control. Heater packages are field installed for all ½ through ton models. Filter ervice Door: eparate service door provides easy access for filter change. Two Inch, Pleated ir Filters: re standard equipment. Filter rack adjustable for " filters. Condenser Fan and Motor hroud ssembly: lides out for easy access. Barometric Fresh ir Damper: tandard on all units. llows up to % outside fresh air. Optional ventilation packages available. Disconnect Kits vailable: Field installed circuit breaker kits for / V KW and toggle disconnects for V units are available. tandard on all electric heat versions of single and three phase (/V) equipment. Toggle disconnects are standard on all electric heat versions of three phase (V) equipment. lope Top: tandard feature for water run-off. Top Rain Flashing: tandard feature on all models. Liquid Line Filter Drier: tandard on all units. Protects system against moisture. Compressor Control Module: tandard on all units. Built-in off-delay timer adjustable from seconds to minutes. -minute on-delay if power interrupt. -second bypass for low pressure control, and both soft and manual lockouts for high and low pressure controls. larm output for alarm relay. High & Low Pressure witches are uto-reset: tandard on all units. Built-in lockout circuit resets from the room thermostat. Provides commercial quality protection to the compressor. Complies with efficiency requirements of HRE/IEN.-7. Certified to NI/RI tandard - for PVU (ingle Package Vertical Units). Intertek ETL Listed to tandard for afety Heating and Equipment NI/UL /C. No. -, Third Edition. Commercial Product - Not intended for Residential application. Form No. - Page of

Capacity and Efficiency Ratings J7L JL JL JL JL JL JL Capacity BTUH,,,,, 7,, EER....... Capacity is certified in accordance with NI/RI tandard -. EER = Energy Efficiency Ratio and is certified in accordance with NI/RI tandard -. ll ratings based on fresh air intake being % closed (no outside air introduction). pecifications -/ Ton through Ton J7L- JL- JL-B JL- JL-B JL-C JL- JL-B Electrical Rating-- Hz / - / - / - / - / - - / - / - - Operating Voltage Range 7-7- 7-7- 7- - 7-7- - Compressor--Circuit Voltage / / / / / / / Rated Load mps./7../. 7./..7/. 7./.../7. 7./.. Branch Circuit election Current...... 7.. Lock Rotor mps / / / 7/7 7/7 / / Compressor Fan Motor & Condenser Fan Motor--HP--RPM / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 / - 7 Fan Motor--mps......... Fan--DI/CFM " - " - " - - - - - - - Blower Motor & Evap. JL-C Blower Motor--HP-RPM-PD /-- /-- /-- /-- /-- /-- /-- /-- /-- Blower Motor--mps......... CFM & E..P. w/filter (Rated-Wet Coil) -. -. -. -. -. -. -. -. -. Filter izes (inches). xx xx xx xx xx xx xx xx xx hipping Weight --LB. 7 7 7 7 7 7 pecifications -/ Ton through Ton lectrical Rating-- Hz perating Voltage Range Compressor--Circuit oltage ated Load mps Branch Circuit election Current ock Rotor mps Compressor Fan Motor & Condenser an Motor--HP-RPM-PD an Motor--mps an--di/cfm Blower Motor & Evap. lower Motor--HP-RPM-PD lower Motor--mps CFM & E..P. w/filter (Rated-Wet Coil) ilter izes (inches). hipping Weight --LB. JL- JL-B JL-C JL- JL-B JL-C JL- JL-B V / / / / / / R.7/. /.. /../.../../. 7...... 7... 7 7. L /./. / / / / JL-C E /- /- - /- /- - /- /- - O 7-7- - 7-7- - 7-7- - F /-- /-- /-- /-- /-- /-- /-- /-- /-- F......... F " - " - " - " - " - " - " - " - " - B /-7- /-7- /-7- /-7- /-7- /-7- /-7- /-7- /-7- B......... -. -. -. -. -. -. 7 -. 7 -. 7 -. F xx xx xx xx xx xx xx xx xx Form No. - Page of

Indoor Blower Performance - CFM at Rated Volts EP in H O High peed J7L JL Low peed ingle peed High peed JL JL Low peed High peed JL JL Low peed High peed JL Low peed / 7/ /7 / / / / / /. 7/ / / /7 / 77/ / / /7. /7 / / / / / / / /. 77/7 7/ /7 / / / / 7/7. 7/7 / 7/ / /7 7/ /7 77/. / / / /7 / /7 bove data is with " standard throwaway filter and " washable filter. For " pleated filter - reduce EP by. in. ee installation instructions for maximum EP information on various KW application. peeds marked bold above are Factory Connected. Ventilation ystem Packages Wall-Mounts are designed to provide optional ventilation packages to meet all of your ventilation and indoor air quality requirements. ll units are equipped with a barometric fresh air damper as the standard ventilation package. ll optional ventilation packages are field-installed only. BROMETRIC FREH IR DMPER - BFD TNDRD The barometric fresh air damper is a standard feature on all models. It is installed on the inside of the service door and allows outside ventilation air, up to % of the total airflow rating of the unit, to be introduced through the air inlet openings and to be mixed with the conditioned air. The damper opens during blower operation and closes when the blower is off. djustable blade stops allow different amounts of outside air to be introduced into the building and can be easily locked closed if required. Barometric Fresh ir Damper ECONOMIZER - EIFM OPTIONL FIELD INTLLED ONLY The economizer system is internally mounted behind the service door and allows outdoor air to be introduced through the air inlet openings. The amount of outdoor air varies in response to the system controls and settings defined by the end user. It includes a built-in exhaust air damper. The economizer is designed to provide free cooling when outside air conditions are cool and dry enough to satisfy cooling requirements without running the compressor. This in turn provides lower operating costs, while extending the life of the compressor. Economizer tandard Features: One Piece Construction - Easy to install with no mechanical linkage adjustment required. Exhaust ir Damper - Built in with positive closed position. Provides exhaust air capability to prevent pressurization of tight buildings. ctuator Motor - volt, power open, spring return with built in torque limiting switch. Proportioning Control - for maximum free cooling economy and comfort. Moisture Eliminator & Prefilter - permanent, washable aluminum construction. Enthalpy Control - adjustable to monitor outdoor temperature and humidity. Minimum Position Potentiometer - adjustable to control minimum damper blade position for ventilation purposes. Mixed ir ensor - to monitor outside and return air to automatically modulate damper position. Form No. - Page of

Electrical pecifications J7L -, Z JL -, Z JL - B, BZ B JL - *, Z* * * JL - B*, BZ* B* B JL - C*, CZ* C* C JL - *, Z* * * JL - B*, BZ* B* B JL - C*, CZ* C* C JL -, Z JL - B, BZ B B JL - C, CZ C C JL -, Z JL- B, BZ B B JL - C, CZ C C JL -, Z JL - B, BZ B B JL - C, CZ C C Rated Volts and Phase /- /- /- /- /- - /- /- - /- /- - /- /- - /- /- - No. Field Power Circuits or or or or or Minimum Circuit mpacity 7 7 7 7 7 7 7 ingle Circuit Maximum Field External Fuse Power or Ckt. Brkr. Wire ize Dual Circuit Maximum Field External Fuse Power or Ckt. Brkr. Wire ize Ckt. Ckt. B Ckt. Ckt. B Maximum size of the time delay fuse or HCR type circuit breaker for protection of field wiring conductors. Based on 7C copper wire. ll wiring must conform to the National Electrical Code and all local codes. These Minimum Circuit mpacity values are to be used for sizing the field power conductors. Refer to the National Electrical code (latest version), rticle for power conductor sizing. Caution: When more than one field power circuit is run through one conduit, the conductors must be derated. Pay special attention to note of Table regarding mpacity djustment Factors when more than three () current carrying conductors are in a raceway. * Top outlet supply option is available only factory installed and only on the selected models. IMPORTNT: While this electrical data is presented as a guide, it is important to electrically connect properly sized fuses and conductor wires in accordance with the National Electrical Code and all local codes. Ground Wire Minimum Circuit mpacity Ckt. Ckt. B Ground Wire ize Ckt. Ckt. B Form No. - Page of

Electric Heat Table - Refer to Electrical pecifications for vailability by Unit Nominal KW..... t V () t V () t V () t V () Kw -Ph mps -Ph mps Btuh.. 7,.. 7,.. 7,77.. 7,..., () These electric heaters are available in /V units only. () These electric heaters are available in V units only. Kw -Ph mps -Ph mps Btuh.7.,7..,7.7. 7, 7..,..., Kw -Ph mps Btuh Kw -Ph mps Btuh..,77..,..,. 7. 7, Heater Packages - Field Installed Designed for adding Electric Heat to KW Units Circuit Breaker tandard on /V s - s ir Conditioner /- s Heater # EHW-L J7L EHW-L EHW-L EHW-L JL EHW-L EHW-L EHW-L EHW-L JL EHW-L EHW-L JL JL JL JL EHW-L EHW-L EHW-L EHW-L EHW-L EHW-L EHW-L EHW-L EHW-L ETL U & Canada Listed Toggle Disconnect tandard on V s -B s -C s /- - K W Heater # K W Heater # N/ N/ EHW-BL N/ EHW-BL EHW7-BL EHW-BL EHW7-BL EHW-BL EHW-BL EHW-BL EHW-BL EHWC-CL EHW-CL EHWC-CL EHW-CL EHW-CL EHW-CL EHW-CL EHW-CL KW Circuit Breaker/Toggle Disconnect Kits Field-Installed Designed for adding circuit breaker/toggle disconnect to KW units Circuit breaker on /- and /- units Toggle disconnect on - units ir Conditioner s J7L JL JL JL JL JL JL Eliminates need for separate disconnect box ETL U and Canada Listed - s -B s -C s /- /- - M odel No. M odel No. No. WMCB-L WMCB-L WMCB-L WMCB-L WMCB-L WMCB-L N/ WMCB-BL WMCB-BL WMCB-BL WMCB-BL WMCB-7BL N/ N/ WMPD-CL WMPD-CL WMPD-CL WMPD-CL Form No. - Page of

Form No. - Page of Return air temperature. D.B./W.B. Capacity F 7 F F F F F F F F F J7L 7/ 7,,,7,,,,,,,,,,,,,,,,,7 / 7,,,, 7,, 7,,,,,,,,,,,,,, / 7,,,,,,,,,, 7,,,,,,,,,7, JL 7/,,,,7,,,,,,, 7,, 7,,, 7,, 7,, / 7 7,7,,7,,,,,,,,,, 7,, 7,, 7,,7, / 7,,,,,7,,,7,7,, 7,, 7,,,,,7,, JL 7/,,,7,,, 7,,,,,7,,7,,7,7,7,,, / 7,,7,,,,,,,,,, 7,, 7,,,,,, / 7,, 7,,,,,,,,,,,,,, 7,,,, JL 7/,,, 7,, 7,,,,,,,,,7 7,7,,,7,, / 7, 7,, 7, 7,,,,,,,,,7,,,,,,, / 7,,,7 7,,,,,,, 7,,,,,,,,7,, JL 7/,,,,,, 7,,7,7,,,,,,,,7, 7, 7, / 7,,,,,,,,7,,,, 7,,,,,,,7, / 7,,,,,,,,,,,,,,,,, 7,,, JL 7/,, 7,,,,, 7,,,,, 7,,,,,,7,, / 7,,7,,, 7,, 7, 7,,7,,,7,,,7,,,, / 7,,,, 7,,, 7,,,,7, 7,,,,,,,, JL 7/,,,,,,,, 7,,7,,, 7,,,,,,, / 7,,,,,, 7,,,,,,,,,7 7,,,,, / 7 7,, 7,,,,,,7,, 7, 7,,,,,,,,, Factors Multiplier Capacity irflow Rated of % - d ate R + BTUH BTUH.7..... pplication Data - Outdoor Temperature

Clearances Required for ervice ccess and dequate Condenser Inlet irflow LEFT IDE RIGHT IDE J 7L, JL, JL, JL " J L, JL, JL NOTE: For side by side installation of two () J**L models there must be between units. This can be reduced to " by using a JL model (left side compressor and controls) for the left unit and J (right side compressor and controls) for right unit. Minimum Clearances Required to Combustible Materials UPPLY IR DUCT FIRT THREE FEET CBINET J 7L, JL " " J L, JL /" " J L, JL, JL /" " Refer to the Installation Manual for more detailed information. Dimensions of Basic Unit for rchitectural and Installation Requirements (Nominal) WIDTH DEPTH HEIGHT UPPLY RETURN MODEL (W) (D) (H) B C B E F G I J K L M N O P Q R T J7L JL. 7. 7. 7.......7..7.. 7........ JL JL. 7. 7. 7. 7.. 7....7 7..7.7. 7..7..7.... JL JL.7..7.............7...... JL ll dimensions are in inches. Dimensional drawings are not to scale. R E Built In O Rain Hood. D Pitch W Electric. Heat upply ir Opening Return ir Opening ide Wall Mounting Brackets (Built In) Top Rain Flashing hipping Location Optional Electrical Entrances I C Heater ccess Panel C. Breaker/ Disconnect ccess Panel (Lockable) Filter ccess Panel Ventilation ir Vent Option Door.7 F P M L H K J Cond. ir Inlet Low Voltage Electrical Entrance High Voltage Electrical Entrance Condenser ir Outlet G T Drain Bottom Installation Bracket Back View.. ide View Front View MI- B Form No. - Page 7 of

ir Conditioning Wall-Mount Nomenclature ERIE NOMINL CPCITY 7 - ½ Ton - Ton - ½ Ton - Ton - ½ Ton - Ton - Ton J L X P X X X J TYPE ir Conditioner Ventilation Options REVIION VOLT & PHE - /// B - /// C - // ee Page for Field Installed Electric Heater options. KW VENTILTION OPTION (ee Table Below) FILTER OPTION P - -inch Pleated COLOR OPTION X - Beige COIL OPTION X - tandard OUTLET OPTION X - Front (tandard) CONTROL MODULE (ee Chart Below) s J7L, JL JL, JL JL, JL, JL Description Factory Installed Field Installed Factory Installed Field Installed Factory Installed Field Installed Code No. Part No. Code No. Part No. Code No. Part No. Barometric Fresh ir Damper - tandard X BFD- X BFD- X BFD- Economizer - Fully Modulating N/ EIFM- B N/ EIFM- C N/ EIFM- C ir Conditioning Control Modules ll s Except s Noted HPC LPC CCM LC LR K K 7 Factory Installed Code Field Installed Part J Factory Only TD Field Installed Only CMC- TD Field Installed Only K 7 = tandard equipment for these specified models. HPC. High pressure control is auto reset. lways used with compressor control module (CCM) which is included. ee note. LPC. Low pressure control is auto reset. lways used with compressor control module (CCM) which is included. ee note. CCM. Compressor control module has adjustable -second to -minute delay-on-break timer. On initial power-up, or any time the power is interrupted, the delay-on-make will be - minutes plus % of the delay-on-break setting. There is no delay-on-make during routine operation of the unit. The module also provides the lockout feature (with retry) for high and/or low-pressure controls, and a -minute timed bypass for low-pressure control. LC. Low ambient control permits cooling operation down to F LR. The alarm relay has a set of normally open and normally closed dry contacts to provide the ability to signal a condition of shutdown on either high or low pressure controls. K. PTCR start kit can be used with all - single phase models. Increases starting torque -x. Not used for -B or -C three phase models. Do not use if K is used. 7 K. tart capacitor and potential relay start kit can be used with all - single phase models. Increases starting torque x. Not used for -B or -C three phase models. Do not use if CMC- is used. upply Registers, Return Grilles, and Return Filter Grilles idewall upply Register - Extruded aluminum - No damper, with sets of individually adjusted blades. Front blades in vertical position. No. G-W G-W G-W Flange pplicable To Dimensions Outside Dimensions " J 7 - x " -/" x -/" " J - " x " -/" x -/" " J - " x " -/" x -/" Return ir Grille - Extruded aluminum with blades fixed at angle. No. RG-W RG-W RG-W Flange pplicable To Dimensions Outside Dimensions " J 7 - x " -/" x -/" " J - " x " -/" x -/" " J - " x " -/" x -/" Return ir Grille - Extruded aluminum with blades fixed at angle. Filter included. No. RFG-W RFG-W RFG-W Flange pplicable To Dimensions Outside Dimensions Filter ize " J 7 - x " -/" x -/" x x " J - " x " -/" x -/" x x " J - " x " -/" x -/" x x Due to our continuous product improvement policy, all specifications subject to change without notice. Before purchasing this appliance, read important energy cost and efficiency information available from your retailer. Form No. February, upersedes: NEW Form No. - Page of