ER100 Series OUT. Specifications. Working fluid Working pressure range Control pressure range. Input voltage 2 wire Input impedance.

Similar documents
EV2000 Series. Specifications. Descriptions Working fluid Max. working pressure Min. working pressure Withstanding pressure

R1000/R3000/R4000/R8000 Series

EV2100V Series OUT VAC EV2100V. Specifications. 196kPa 196kPa Control pressure range Assured pressure range Power voltage Current consumption

Pneumatic components (Electro pneumatic Regulator) Safety Precautions. 3 When releasing secondary control pressure,

Vacuum Equipment. Application. Series

Flowsensor for compressed air


Series variation. Auxiliary valve. Quick exhaust, and circuit switchover valves, etc. are available. Port size (Rc) Page. Model Product appearance

Series ITV0000. Compact Electro-pneumatic Regulator ITV N. IITV00 02 n. How to Order F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Precision Regulators.

Table of Contents. Proportional & Precision Regulator Instrumentation

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Data Sheet. I/P and E/P converters. RS stock numbers ,

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

How to Order ITV N. Nil. EXHc. Base type. Nil. ø1/4"

Series ITV0000. Compact Electro-Pneumatic Regulator ITV N Q. IITV00 02 n. How to Order. For single unit and single unit for manifold

Sensor specifications Model no.

Pressure Control Equipment

Electro-Pneumatic Regulators. Electronic Vacuum Regulators

Electro-Pneumatic Regulator Electronic Vacuum Regulator

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

Numatics 2003 Rev. 11/03 PDFPRECISION-1

Features and Benefits

Compact direct acting precision regulator

Digital display Pressure range ON/OFF output Linear output Model

MULTISTAGE MICRO EJECTORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS. Caution

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Solenoid Pilot Operated Proportional Directional Control Valve

ELECTRO-PNEUMATIC TRANSDUCING REGULATORS CONTENTS ACCESSORIES GENERAL CATALOG AIR TREATMENT, AUXILIARY, VACUUM, AND FLUORORESIN PRODUCTS.

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

1 Pneumatics. Transmitters VR4151 VR4152 VR1210 VR1220 VR1210F VR1220F VR1211F VR VR3200 VR3201 VR3100 VR3110

ETR Series ELECTRO-PNEUMATIC TRANSDUCING REGULATORS. Electro-Pneumatic Transducing Regulators

MULTISTAGE MICRO EJECTORS

Electro-Pneumatic Regulator / Electronic Vacuum Regulator

SP-20 Input. Installation and Operating Instructions Electro-Pneumatic Linear Positioner. Description of Device. Part Number System

I/P CONVERTER INSTRUCTION MANUAL (E)IM-TE100/00-R5

Piping labor reduced A flexible system has been adopted. E-P HYREG. Cylinder behavior and pressurization control. Example

Pneumatic Actuators. TGA Specifications

SMART VALVE POSITIONER 4 to 20 ma + HART Digital Communication. smar B87

Models SPG5A and SPG6A

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Vacuum Ejector with Solid State Timer

INSTRUCTION MANUAL EP-500 EIKO SOKKI CO., LTD. Model : * ELECTRONIC REGULATOR * (BOOSTER AMP) ISSUED: MAR BOOSTERAMP OFF EPA-300 SUP A300G-12

Air Catch Sensor. Non-Contact Sensor for Workpiece Placement Confirmation

Electro-pneumatic Proportional Valve. Specifications. Model Flow type Pressure type VEF2121

HN B G1/US B G2/US B G3

Vacuum pump system type

Moniteur INSTALLATION & OPERATING INSTRUCTIONS. SERIES 40 Positioners. Installation and Operating Instructions Series 40 Positioners.

Thread type to 0.8 MPa to 0.8 MPa. Note) Air operated type is model IR2120 only. Note) Air operated type is model IR3120 only.

Series ITV. Electro-pneumatic Regulator Electronic Vacuum Regulator F.R.L. AV AU AF AR IR VEX AMR ITV IC VBA VE VY1 G PPA AL

Electro-Pneumatic Regulator Electronic Vacuum Regulator. Series Model Set pressure range Port size to 0.1MPa to 0.5MPa to 0.

W1000/W3000/W4000/W8000 Series

Electro-Pneumatic Linear Positioner Installation and Operation Instructions B GB

Compact Vacuum Regulator. How to Order. Nil. ATMc. Base type Nil M

BROIL SENSOTEK INDUSTRIES, I-195, GIDC-2, MEHSANA , STATE: GUJARAT, INDIA.

MICRO EJECTORS ME12, ME25, ME60. Specifications. Mass MICRO EJECTORS. Vacuum switches. Micro ejectors. Single and twin solenoid valves.

SINGLE-ACTING ACTUATORS FOR DOUBLE-ACTING & SERIES 65 POSITIONERS PNEUMATIC & ELECTRO-PNEUMATIC. The High Performance Company

Series VCHR. Direct Operated Regulator for 6.0 MPa (Relieving Type) Service life: 10 million cycles. How to Order

Compact Flow Rate Sensor. RAPIFLOW FSM3 Series Resin Body Type. Diversified High Performance. High performance. User-friendly. Compatible CC-1235A 1

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

Pressure Sensors. for liquid and gaseous media

Electro-Pneumatic Regulator/Electronic Vacuum Regulator

Q1 Q2 Q3. 2 stage performance. 3 stage performance. Suction flow rate. 250% suction flow rate increase. Release flow rate adjusting needle.

Series ITV1000/2000/3000

Pressure sensor for liquid and gaseous media QBE620-P...

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

VAS VAS VACUUM SWITCH SPECIFICATIONS. DIMENSIONS (mm)

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Related vacuum products

OBE (On-Board Electronics) Type Direct Operated Linear Servo Valves (Size: 01 & 03) LSVG-01-EH-*-**-**-10, LSVG-03EH-*-**-**-10/1006

PROPORTIONAL VALVES SERVO VALVES. Maximum operating pressure MPa {kgf/cm 2 } Model [Model No.]

Ready for outdoor use too!

Mounting and Operating Instructions EB 3913 EN. Electropneumatic Converters i/p Converter Type

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

Specifications. Model Flow type Pressure type. Air Maximum operating pressure. 1.0 MPa Ambient and fluid temperature. 3% F.S.

TG-S Specifications TG-12S Rc3/8. 6 to 20

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

Transmitters: Relay Valve VR4151/4152

Series ISA. Air Catch Sensor. For Detection of Work Presence

Digital Flow Switch (Sensor Part) Operation Manual

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

OM Field-Type I/P Converter Model : KUX113 User's Manual

Digital Pressure Gauge / Pressure Switch

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

4 Note 1) Value for communications type. (PROFIBUS DP)

Contents. Pressure measurement technology Pressure calibrators 18 Exercises 19-20

Series AV2000/3000/4000/5000

Process Valve/Series VN The cylinder operation by external pilot air Can be operated with pressure differential zero.

Power Valve: Regulator Valve. Specifications. Model VEX Operation type Fluid Max. operating pressure Set pressure Air operated.

Electric Proportional Pressure Reducing Valves Series ERP 03.ERP

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

SATRON VTe pressure transmitter

E22 Proportional Technology

Paddle-wheel flow controller for On/Off control

Circuit of directional control valve and regulator. Simplifying circuit design. Space saving and piping. work eliminated. Automating pressure control

Fisher 546 Electro Pneumatic Transducer

Paddle-wheel flow controller for On/Off control

fact sheet Masoneilan * 8007/8008 Series Electro-pneumatic Transducers GE Energy Nozzle Design Reducing Effects of Vibration Overview

Micro-differential Pressure High-precision Digital Pressure Sensor For Gas DP-M SERIES

Transcription:

Electro pneumatic regulator (nozzle flapper method) ER Series Variable controlling air pressure with electric signals ( to V DC / to ma DC) up to.mpa. Booster relay integrated and large flow rate. JIS symbol EXH Overview This electro pneumatic regulator ER series controls air pressure constantly with electric signals. This eliminates bothering works such as manual pressure adjustment, multistage pressure switching with combining several regulators and valves, etc. Changing input of voltage / current, the air pressure can be ideally controlled to achieve remote control or FA in pneumatic circuits. Features Compact Compact major dimensions with X. Space saving. High precision control Shown in linearity ±.%F.S. and hysteresis %F.S., accurate pneumatic control is enabled. Easy maintenance Fixed orifice and filter integrated. Wide adjusting range and span points can be adjusted within wide range. Specifications Working fluid Working pressure range range Input voltage Voltage range wire Input impedance Input current Current range wire Input impedance Linearity Hysteresis Max. flow rate (ANR) Air consumption (ANR) Step response time Working temperature Mechanical vibration proof Port size Mass ER ER Clean compressed air (refer to Page for air circuit. ). to.mpa (control pressure +.MPa ). to.mpa to ma DC /min or less to V DC ±.%F.S. or less %F.S. or less Note /min.sec or less (loadless) to C m/s or less (Hz) Rc/, /.kg. to.mpa /min or less Note : Limited to the closed circuit in the secondary side, and the pressure may vary if used as air blow, etc. How to order ER B A B A. to.mpa. to.mpa B to V DC to ma DC (control pressure "". to.mpa only ) Rc/ Rc/ B Bracket attached * *Part No. for bracket is ER-B.

Internal structure and parts list ER Series Internal structure and parts list / dimensions Refrigerating Desiccant High polymer membrane dryer Air filter Automatic drain other (Module) (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve No. Parts name Material No. Parts name Material Coil Permanent magnet Nozzle Orifice Flapper Stainless steel Brass Diaphragm Relief valve Main valve Valve stem Brass Stainless steel Dimensions Orifice D() G/ fitting for cables (Cable O.D.. or less) D() Model no. ER * -* ER * -* D Rc/ Rc/ Silencer Check valve / others Joint / tube F. generator auxiliary / pad Mechanical dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water. -R Bracket. unit Electro pneumatic regulator Note: Install the electro pneumatic regulator vertically (facing coil section top). For other installation attitudes, and span points must be adjusted again.

ER Series I/O characteristics Flow characteristics.... Working pressure:.mpa.... ER ER...... (VDC) Flow rate ( / min ANR )

pneumatic regulator (nozzle flapper method / large flow rate) ER Series A piezoelectric element and semiconductor pressure sensor are used to achieve precise air pressure control. Pressure monitor is also possible. JIS symbol EXH Refrigerating Desiccant High polymer membrane dryer Air filter Overview In electronic pneumatic regulator ER series, piezoelectric elements and semiconductor pressure sensors are used to control precise and constant air pressure with electric signals. Features New raw material Piezoelectric element (piezoelectric element) is used for nozzle flapper to improve resistance to mechanical vibration. Feedback control method Feedback control method with semiconductor pressure sensor and electronic circuit is used to achieve precise and outstanding temperature characteristics and stability. Common exhaust method Very small air consumption (/ of conventionals) and low operation cost. Common exhaust method eliminates environmental contaminations. Large flow rate type Max. flow rate is /min (standard state) for ER. Large relief flow also allows to control large load easily. Pressure monitor available. Pressure monitor terminal integrated. (voltage input type only) Specifications Working fluid Working pressure range range Voltage Input voltage wire Input impedance Current Input current wire Input impedance How to order ER B A Block diagram Control circuit B ER ER ER Clean compressed air (refer to Page for air circuit. ) to kpa to kpa. to.mpa to.mpa. to.mpa to.mpa to V DC to V DC k to ma DC (power supply not required ) or less Power voltage Current consumption Linearity Hysteresis to V DC (ripple ratio % or less, safety power supply ) ma or less ( wire ) ±.%F.S. or less Note.%F.S. or less Note Max. flow rate (ANR) Air consumption (ANR) Step response time Working temperature /min /min /min or less sec. or less (loadless) to C /min Monitor output Mechanical vibration proof Port size Mass Refer to Page characteristic chart. Note m/s or less (Hz) Rc/, /.kg Note : Characteristics where control pressure range is to %. Limited to a closed circuit in the secondary side, and the pressure may vary if used as air blow, etc. Note : Monitor output function is provided only for voltage input type, but not for current input type. Voltage Displacement Pressure Piezo - electric bimorph Nozzle flapper Volume booster Pneumatics sources Output pressure A B B to kpa to.mpa to.mpa to V DC to V DC to ma DC Rc/ Rc/ Bracket attached * *Part No. for bracket is ER-B. Automatic drain other (Module) (Separate) Small F. Precise Electro pneumatic Auxiliary Flow control valve Silencer Check valve / others Joint / tube F. generator auxiliary / pad Mechanical dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Water cooling refrigerator for water. unit pneumatic regulator Monitor output Pressure sensor

ER Series Internal structure and parts list EXH No. Parts name Material No. Parts name Material Cover Piezo - electric bimorph Nozzle Pressure sensor Filter ( m ) Orifice Diaphragm stud ABS resin Ceramics Stainless steel (Diffusion semiconductor) Polypropylene Brass Min- Y packing seal Diaphragm Body Valve assembly Valve seat Exhaust valve Min- Y packing seal Fluoro rubber Brass/stainless steel Fluoro rubber Dimensions () -G/ Fitting for cable (Cable O.D.. or less) Rc / -Rc D. Bracket -M *Rc is as same as old PT. Model no. ER * -* ER * -* D dimension / /

I/O characteristics ER Series I/O and flow characteristics to V DC ( wire) to V DC ( wire) to ma DC ( wire)... Refrigerating Desiccant High polymer membrane dryer....... ER ER ER....... ER ER ER....... ER ER ER Air filter Automatic drain other (Module) (Separate) Small F. Precise Electro pneumatic Auxiliary (VDC) (VDC) (madc) Flow control valve Silencer Flow characteristics ER- ER- ER- Conditions JIS B conformed Working pressure: kpa Port size: Rc/ (kpa) Flow rate /min (ANR) Monitor output voltage range Conditions JIS B conformed Working pressure:.mpa Port size: Rc/..... Flow rate /min (ANR). ER- ER- ER- Conditions JIS B conformed Working pressure:.mpa Port size: Rc/... Flow rate /min (ANR) Check valve / others Joint / tube F. generator auxiliary / pad Mechanical dif. pres. Seating / close contact conf. Pressure for coolant for air Total air system Accuracy Linearity: ±.%F.S. Hysteresis:.%F.S. Accuracy Linearity: ±.%F.S. Hysteresis:.%F.S. Accuracy Linearity: ±.%F.S. Hysteresis:.%F.S. Water cooling refrigerator for water Monitor output voltage (VDC) (kpa) Monitor output voltage (VDC)..... Monitor output voltage (VDC)..... unit pneumatic regulator