A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar

Similar documents
A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar

A and B Series Sensors for Humidity and Temperature for industrial applications from C and up to 25 bar

HUMIDITY / TEMPERATURE TRANSMITTER

EGQ 212: Duct transducer, CO 2 and temperature

Output signal active humidity DC V 22DTH-51MB DC V, DC V DC V DC V DC V DC V

TEMPERATURE - HUMIDITY VAISALA HMP155

Humidity. Characteristics. Applications. Capacitive humidity measurement, temperature measurement via Pt100/Pt1000 Sensor

For air dampers and control valves of oil or gas burners

Pressure transmitter JUMO dtrans p02

Operating Instructions. Angle Seat Control Valve. Type 7020

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features. Display

OEM Pressure Transmitters

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Carbon Dioxide (CO2) + Humidity (rh) + Temperature (T) transmitter with Display for room mounting. Features

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

DSL-240 MkIII Single Pass Dust Monitor Measures mg/m 3 using DDP

Model Number Structure

Portable pressure calibrator, Wally Box III Model CPH7600

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Pressure Transmitter JUMO dtrans p30 Type

Operating Instructions. Pneumatic Control Valve Low Temperature. Type Series GS3

Temposonics. M-Series Analogue / SIL2* Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm

SPT- I / U PRESSURE TRANSMITTER for general applications

Differential Pressure Sensors

Miniature resistance thermometer For sanitary applications Model TR21-A, with flange connection

LTX RF LEVEL SENSOR. Instruction Manual

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

For air / gas dampers and control valves of oil or gas burners

Transmitters Sensors. Transmitters. Sensors. Pressure Temperature Humidity Air velocity Airflow

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

ITVX Series. Stepless control of air pressure proportional to an electrical signal. Supply pressure: 5.0 MPa

Beck. The differential pressure transmitter for air with IP65

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

AXIAL FANS Axis / Tubo OPERATION MANUAL

Optidew Vision Optical Dew-Point Meter

Operating Instruction for Electronic Pressure Switch. Model: PDD

Operating Instructions for Pressure Transmitter with Digital Display. Model: PDA

System 6000 Electropneumatic Converter for Direct Current Signals i/p Converter Type 6126

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Thermal hysteresis 0.5% max. of full scale (within compensated temperature range) 1% max. for ranges mbar mbar mbar

Pipe surface resistance thermometer, for clamping Model TR57-M, miniature design

Differential Pressure Sensors

MWF+ Application. Types Available. Average temperature sensor. Datasheet

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

Class 100 temperature and humidity dataloggers

Continuous level sensor NSK

GS-AQ1000 VOC Indoor Air Quality Sensors

* * Rev. 9 01/18 Product Manual

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Pressure Transmitter JUMO dtrans p30 Type

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Insertion Temperature/Humidity/ Dewpoint temperature Sensor HTY78X3/HY78X3/HTY78X6/HY78X6/HY79X3

Pressure sensor with built-in amplification and temperature compensation circuit

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

MINI MCR-SL-UI-UI(-SP)(-NC)

SIGNET Temperature Transmitter

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

Solid State Relays, 3-phase

Temposonics. M-Series Analog. Magnetostrictive Position Sensors. Temposonics MH Measuring length mm SENSORS

产品技术规范. Product Name: Product Technical Specification SMARTSTONE. No.: CPFL0002 Version: A Issued date: Page 1 of 16

OPERATING INSTRUCTION

INTERNATIONAL METAL ENGINEERING

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MB Analog. Technical Data / Description

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

Lumitester PD-20 Control Kit

Operating Instructions CYR52

AKF10+ Application. Types Available. Duct-/Immersion temperature sensor. Datasheet

Pressure Sensor/PS-A (ADP5)

Foxboro Dew Point Measurement System Model 2761 Mechanical DEWCEL Element Model 2781 Electrical DEWCEL Element

Industrial Power Supplies

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

Switching DC Power Supply

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Operating Instructions TF04

Series 7000 Torque Sensor for PTO-shafts

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Heat Meter Integrator

ecotrans Lf 01/02 Microprocessor Transmitter / Switching Device for Conductivity

Temposonics. M-Series PWM. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm. Document Number Revision B

Technical Data Part-turn gearbox 2SP78

EMERSON CLIMATE TECHNOLOGIES-EX

VLF45... Hot Air Valves. Siemens Building Technologies HVAC Products

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

Electronic Ignition Module

High-speed detection even a little liquid leak

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Pressure transmitter UNIVERSAL CA

FS5 Thermal Mass Flow Sensor For various gas flow applications

BAPI-Stat 3 Room Sensor

Figure 1: WPR2 Dimensions and Hardware

Series 7000 Torque Sensor for PTO-shafts

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

Level Measurement based on Archimedes Principle. Device Description

Transcription:

Galltec Mess- und Regeltechnik GmbH MELA Sensortechnik GmbH D-71145 Bondorf. Germany D-07987 Mohlsdorf-Teichwolframsdorf. Germany Tel. +49 (0)7457-9453-0. Fax +49 (0)7457-3758 Tel. +49(0)3661-6704-0. Fax +49(0)3661-6704-0 E-Mail: sensoren@galltec.de. Internet: E-mail:mela@melasensor.de. Internet: Sensors for Humidity and Temperature for industrial applications from -80...00 C and up to 5 bar AK... with SVKA.0E... duct version up to 150 C AW... with SVKA.00... wall moumting AW... with SZKA.0H... (sensor part from -80...00 C) sensors in the A series combine the digital measured value processing with the advantages of our robust industrial sensors which can be used at temperatures up to -80...00 C resp. at pressures up to 5 bar and are ideally suited for demanding industrial applications. The A series with exchangeable sensor part consist of a calibrated sensor part with 4-pin plug and a transmitter with analog output. Sensor part and transmitter can be combined and matched with each other, according to the physical and mechanical requirements. The measured humidity and temperature values are calculated in the calibrated sensor part with the calibration values stored there, and are passed on as digital measurement values. The sensor parts are either firmly connected to the transmitter or are exchangeable via plug-in connection and can be readjusted on site using buttons and LED. They can also be factory-calibrated and readjusted using software. Description of the Sensor The sensors of the A and B series with integrated hx processor measure humidity by means of a humidity-dependant condenser. The capacitive Mela humidity measuring element, produced using thinfilm technology, consists of a base plate, on which the electrodes are housed and a hygroscopic polymer layer above it. The hygroscopic polymer layer absorbs water molecules from the medium to be measured (air) or releases them, thereby altering the capacity of the condenser. The transmitters with the hx processor use the values of the relative humidity and the temperature to calculate the dew point temperature, the enthalpy, the mixing ratio, the absolute humidity or the wet-bulb temperature, in accordance with the laws of physics ). The values are emitted at two analogue outputs with the standardised signals 0.1VDC or 0.10VDC or 4.0mA. The outputs can be configured differently and are defined using the software. Further measuring ranges on request. The sensor parts and transmitters of the B series are firmly connected. In addition, the installation of a passive temperature element is possible (e.g. Pt100). All further technical features correspond to the ones of the A series. The scope of delivery includes the sintered high-grade steel filter ZE13. If a better dynamics should be required, we recommend to use the filter type ZE04 together with a PTFE filter which protects the humidity sensing element directly. We recommend to do so in particular at low air speeds and also its increased service life, even under more challenging operating conditions (pollutant impact or permanent humidity > 95 %rh). The use of different filters is not possible. The sensors are designed for unpressurised systems (except the...hd... version), the measurement medium is nonaggressive air. Please consult application instructions for the sensing elements (product info sheet no. A 1) or check with the manufacturer for further information which you need to bear in mind when using humidity sensors with capacitive sensing elements. ) The accuracy of the calculated values depends on both the operating point in accordance with the hx diagram and on the primary values measured. page 1 of 9

Technical Data for Humidity and Temperature Humidity measuring range... 0...100%rh measuring accuracy *) 10...90%rh at 3 C... ±1.5%rh at <10%rh or >90%rh... ±%rh influence of temperature (TK)... ±0.0%rh/K hysteresis... < 1%rh response time t 63 at v=m/s... < 10 s *) ex works. Depending on the specific range of application a regular recalibration of the sensor parts has to be effected. Higher accuracies on request. Temperature measuring element... Pt1000 cl.b output range... see table page 3 measuring accuracy at 3 C *)... ±0,15K influence of temperature (TK)... <0.005 K/K *) depending on the (extension) of the output range, max. 0,5 K Options Digital display lines, 3 digits + 1 decimal place display approx. 1 x 40 mm², digit approx. 8 mm high Order designations with fixed sensor parts of B series Series B Series B Design duct version K wall mounting two-piece design Physical output two active outputs K one active output, temperature passive relative humidity active temperature active Output signal 0...1 V 1 0...10 V 4...0 ma 3 Special version operating temperature -40 up to 85 C (standard) 00 Output range 1 see table on page 3 Output range see table on page 3 ammonia resistant -40...85 C 11 operating temperature up to -50...150 C (duct version) ammonia resistant -50...150 C (duct version) operating temperature up to -80...00 C (two-piece design) for use in temperatures up to -60...160 C and pressures up to 5 bar design thermally decoupled -80...00 C Voltage supply 6...30 VDC / 6...6 VAC 6 Filter Type of connection and characteristics of design 1) Operating temperature range = output range of temperature ) Maximum length is 5m x Tube length depends on sensor type and special design page of 9 15...30 VDC / 13...6 VAC F 10...30 VDC A open filter of high-grade steel ZE04 and PTFE protection, IP00 sintered metal filter of stainless steel ZE13 (standard), IP65 13 stainless steel filter with PTFE membrane ZE6, IP65 6 with display length of cable, sensor part ->transmitter 1.5m special length of cable in m rounded up ) other specialities (special type) W Z C F T 0E 1E 0H HD TH 94 ydx 1K5 yyx YYY General Data measuring medium... air, non-aggressive operating voltage 0...1 V... 6...30 VDC / 6...6 VAC 0...10V... 15...30 VDC / 13...6 VAC 4...0 ma...10...30 VDC power consumption... < 7 ma load R L (current output) load resistance R L (Ω)= supply voltage - 10 V 0,0 A ± 50Ω (voltage output) 0...10(1) V... 10 () kohm admissible ambient temp. on the transmitter... -40...85 C when using the duct sensor up to 150 C... -40...50 C degree of protection...transmitter... IP65 measuring head (sensor part)... (see table) plug-in connection sensor part ----> transmitter IP67 material of housing sensor part... stainless steel transmitter... pressure die casting of alu Directive about electromagnetic compatibility 004/108/EG DIN EN 6136-1... issue 10/06 DIN EN 6136--3... issue 05/07 Order designations for Transmitters of A Series Series Transmitter A Design duct version K Order designations for exchangeable sensor parts of A Series Series S Series S Design stainless steel Ø 15 mm V stainless steel Ø 15 mm, two-piece Physical output relative humidity active + temperature active K Output signal digital ASCII Galltec-Mela protocol A Special version operating temperature range -40 up to 85 C (standard) 1) 00 operating temp. range -50 up to 150 C (duct version) 1) operating temperature range -80 up to 00 C (two-piece) 1) operating temperature range -60 up to 160 C 1) and admissible ambient pressure up to 5 bar Output range H 0...100 % r.h. F1 Output range T 1) Voltage supply 3.0 VDC 3 Filter open filter of stainless steel ZE04 and PTFE protection, IP00 94 Type of connection and characteristics of design wall mounting Physical output two active outputs K relative humidity temperature active temperature passive Output signal 0...1 V 1 0...10 V 4...0 ma 3 Special version none 00 Output range 1 see table on page 3 Output range see table on page 3 Voltage supply 6...30 VDC /6...6 VAC 6 15...30 VDC / 13...6 VAC F 10...30 VDC A Filter none 00 characteristics of design with display plug-in connection 1 pin specialities of design sintered metal filter of stainless steel ZE13 (standard), IP65 13 stainless steel filter with PTFE membrane ZE6, IP65 6 plug-in connection 1 pin cable length of two-piece design 1.5 m (standard) special cable length of two-piece design ) specialities of design W F T C 0D0 CS0 Yxx Z 0E 0H HD CS4 1Kx yyx YYY

Output ranges of B Series with fixed sensor part resp. A Series transmitter (to be specified) The following physical output parameters are calculated from the humidity and temperature values measured. The tolerances to be expected therefore result from the tolerance limits of the measured values. humidity 0...100 % r.h. F1 temperature -60...160 C 66-80...00 C 8-50...150 C 59-40...85 C 48 P100 1/3 DIN cl.b for the B series P100 1/3 DIN cl.b in the case of sensor parts SV(Z)KA... for the A series dew point -0...70 C D enthalpy 0...80 KJ/Kg H1 Mixing ratio 0...100 g/kg dry air X3 absolute humidity 0...0 g/m³ A1 wet-bulb temperature -10...50 C W1 no output output not connected 00 Your configuration Output 1 Output C Accessories Designation Product no. Data sheet Description ZA 4 as designation F5.1 Attachment plate for mounting sensors in ducts or wall bushings, for sensor tubes 15 mm Weather protection ZA 161/1 with adapter sleeve 00.50 as designation F5.1 recommended for outside use to protect from rainfall and sunlight with adapter sleeve 00.50 also suitable for rod sensors 15 mm ZE 31/1-1 ZE 31/1-33 ZE 31/1-75 ZE 31/1-84 ZE 31/1-97 as designation F5. Standard humidity to check the accuracy of the sensors at 1 %rh and 5 C Standard humidity to check the accuracy of the sensors at 33 %rh and 5 C Standard humidity to check the accuracy of the sensors at 75 %rh and 5 C Standard humidity to check the accuracy of the sensors at 84 %rh and 5 C Standard humidity to check the accuracy of the sensors at 97 %rh and 5 C ZE33 as designation F5. Adapter for humidity standard ZE 31/1 User instructions Installation The sensors are to be attached in a position representative for the climate measurement. The position the sensor is mounted in (horizontal, vertical) does not matter. However, it should be mounted in such a way that no water can get into it. Please note the maximum permissible ambient temperature for the sensor and transmitter when installing it. The transmitters always have to be installed in such a way that the connection plugs are not exposed to a higher temperature either (>85 C). The duct sensor SVKA.0E... is mounted with an insulation length of at least 134 mm for use at 150 C (refer to dimension drawing). The tightening torque when installing the pressure-resistant sensors (type SZKA.HD...) may not exceed 5 Nm. In order to maintain interference immunity in accordance with EN 6136 when it is in use, we recommend to use a screened cable (e.g. type 8x AWG6 C UL order no. 5339) for connecting the sensors, and have this fitted into the sensor s EMC heavy-gauge conduit thread by a qualified electrician. In a clean environment, the sensor is maintenance-free. The protective filters should only be screwed off carefully to check functioning with the humidity standard. It is important not to touch the highly sensitive sensor element in the process. If necessary, soiled filters can be screwed off and rinsed. When you screw them back on, bear in mind that sensors will not measure accurately again until they are completely dry. Sensors with integrated PTFE filter be completely and carefully cleaned with distilled water. It is not possible to exchange the PTFE filter on the humidity sensor element. Dust does not cause any harm to the humidity sensor, however, if there is an increased build-up of dust this does affect dynamic performance. Dew formation and splashes do not damage the sensor, although corrupted measurement readings are recorded until all the moisture on and directly around the sensor element has dried up. Damaging Influences Agents that are corrosive and contain solvents, depending upon the type and concentration of the agent, can result in faulty measurements and cause the measuring element to break down. Substances deposited on the sensor are damaging as they form a water-repellent film (this applies to all humidity sensors with hygroscopic measuring elements); e.g. resin aerosols, lacquer aerosols, smoke deposits etc. In order to check functioning in the place of installation, we recommend that you use our ZE31/1-type humidity standard... (accessories). To ensure the given accuracy of the sensors, we recommend a calibration cycle of 6-1 months. Additional information Please consult application instructions for the sensing elements (product info sheet no. A 1 and B1.1), which you can get from, for further information which you need to bear in mind when using humidity sensors with capacitive sensing elements. page 3 of 9

Dimensions A Series Dimensions of clearance holes x Ø4,8 View rotated by 180 measuring head exchangeable measuring head exchangeable measuring head exchangeable Ømax.19 AWK... with SVKA.00... for wall mounting -40...85 C Ømax.19 special teflon cable special teflon cable SW7 AWK... with SZKA.HD... sensor part up to 160 C and 5 bar AWK... with SZKA.0H... sensor part up to 00 C AKK... with SVKA.0E... for duct mounting up to 150 C measuring head exchangeable insulation distance e.g. insulated wall or air (-40... 50 C) (for high temp. applications up to max. 50 C) sealing e.g. ZA4 max. 100 mm 57 8 Seite 4 von 9

Dimensions B Series Dimensions of clearance holes x Ø4,8 View rotated by 180 Ømax. Ømax. BWxx.00... for wall mounting -40...85 C Ømax.19 special teflon cable special teflon cable SW7 BZxx.HD... sensor part up to 160 C and 5 bar BZxx.0H... sensor part up to 00 C sealing e.g. ZA4 insulation distance e.g. insulated wall or air (-40... 85 C) (for high temp. applications up to max. 50 C) 3 89 max. 100 mm BKxx.0E... for duct mounting up to 150 C sealing e.g. ZA4 insulation distance e.g. insulated wall or air (-40... 85 C) (for high temp. applications up to max. 50 C) 44 301 max. 100 mm BKxx.TH... for duct mounting up to 00 C page 5 of 9

Connection diagrams 4...0 ma x 4...0 ma 1 1 output temperature 4 0mA 4 0 ma 4 0 ma 3 + U B 10 30 V DC 3 + UB 10 30 V DC 0...1 V x 0...1 V 1 GND 1 GND + U B 6 30 V DC or 6 6 V AC + U B 6 30 V DC or 6 6 V AC 3 0 1 V 3 0 1 V 4 4 output temperature 0 1 V 0...10 V x 0...10 V 1 GND 1 GND + U B 15 30 V DC or 13 6 V AC + U B 15 30 V DC or 13 6 V AC 3 0 10 V 3 0 10 V 4 4 output temperature 0 10 V 4...0 ma and temperature passive 0...10(1) V and temperature passive output temperature, passive output temperature, passive page 6 of 9

User instructions for in situ alignment via internal keypad and LED Humidity adjustment 1-point-adjustment (Offset) Selection of calibration mode press button DOWN for at least 3 sec. LED lights up 1 time 1-Point-adjustment humidity mode is reached LED lights up permanently For modifying of adjustment value press buttons UP / DOWN: + / - 0.1 %rh The adjustment value is saved. Termination of adjustment mode at any time: press button UP for at least 3 sec. Humidity adjustment -point-adjustment (lower point, 33 %rh) see accessories ZE 31/1-33 Selection of calibration mode press button DOWN for at least 3 sec. LED lights up 1 time press button DOWN 1 time shortly LED lights up times -point-adjustment 33% humidity mode is reached LED lights up permanently For modifying of adjustment value press buttons UP / DOWN: + / - 0.1 %rh The adjustment value is saved. Termination of adjustment mode at any time: press button UP for at least 3 sec. Humidity adjustment -point-adjustment (upper point, 75 %rh) see accessories ZE 31/1-75 Selection of calibration mode press button DOWN for at least 3 sec. LED lights up 1 time press button DOWN times shortly LED lights up 3 times -point-adjustment 75% humidity mode is reached LED lights up permanently For modifying of adjustment value press buttons UP / DOWN: + / - 0.1 %rh The adjustment value is saved. Termination of adjustment mode at any time: press button UP for at least 3 sec. page 7 of 9

Temperature adjustment 1-point-adjustment A very good thermal coupling between the reference device and the measuring head are the precondition when doing temperature compensation. Selection of calibration mode press button DOWN for at least 3 sec. LED lights up 1 time press button DOWN 3 times shortly LED lights up 4 times Temperature 1-point-adjustment mode is reached LED lights up permanently For modifying of adjustment value press buttons UP / DOWN: + / - 0.1 C The adjustment value is saved. Termination of adjustment mode at any time: press button UP for at least 3 sec. Restore factory settings press buttons UP and DOWN simultaneously for more than 10 sec. All user adjustments will be reset. Mounting instructions Position Connection The sensor has to be installed vertically with the measuring head downwards or horizontally. Do avoid positions where water ingress can occur. We recommend that you lay the connection lines in a loop so that any water that may be present can run off. Install the sensor at a place where characteristic levels of humidity occur. The sensor tube resp. measuring head should be exposed to the flow of air. Avoid installation next to heaters, doors or on outer walls. Avoid places exposed to the sun. Not reaching the given minimum air speed can lead to measurement errors The electrical connection must be carried out by qualified personnel only. The sensor contains sensitive electrical components. When opening the housing, make sure you comply with the electrostatic discharge precautions (ESD). Pay attention to the load according to the operating voltage when using sensors with a current output. Lines to and from the sensor must not be installed parallel to strong electromagnetical fields. If there is any chance of an electrical surge, please install surge protection devices. page 8 of 9

User instructions (see also page 3) Dew formation Cleaning of filters and protective baskets Cleaning of capacitive sensing element Damaging influences Dew formation and splashes do not damage the sensor, although measurement readings are corrupted until all moisture on and around the sensing element has dried up completely. If necessary, soiled filters and protective baskets can be screwed off and rinsed carefully. Bear in mind the sensors wil not measure accurately until filters are completely dry. Please do not touch the highly sensitive sensing element. Loose dust can be carefully cleaned off the humidity sensing element using distilled water or by blowing the dust carefully off. Please do not touch the highly sensitive humidity sensing element in the process. Depending on type and concentration, agents that are corrosive and contain solvents, can result in faulty measurements and can cause the sensor to break down. Substances deposited on the sensor (e. g. resin aerosols, lacuer aerosols, smoke deposits etc.) are damaging as they eventually form a water-repellent film. This information is based on current knowledge and is intended to provide details of our products and their possible applications. It does not, therefore, act as a guarantee of specific properties of the products described or of their suitability for a particular application. It is our experience that the equipment may be used across a broad spectrum of applications under the most varied conditions and loads. We cannot appraise every individual case. Purchasers and/or users are responsible for checking the equipment for suitability for any particular application. Any existing industrial rights of protection must be observed. The quality of our products is guaranteed under our General Conditions of Sale. Data sheet AB-Serie_EN. Issue: June 013. Subject to modifications. page 9 of 9