distribution transformers. Single-Phase Overhead GENERAL. Cooper Power Systems manufactures a complete line of single-phase overhead-type

Similar documents
www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Open

www. ElectricalPartManuals. com Substation Transformers Primary or Secondary Unit

SURGE DURABILITY AND IMPROVED TRANSFORMER PROTECTION

Single phase pole mounted. 11kV. Electrical Engineer KEU ID#:

RELIABLE POWER COOPER POWER SYSTEMS. Transformer Products Group FROM

Figure 1. Single-phase pad-mounted voltage regulator. STANDARD FEATURES

C. System Design and Performance Requirements

Figure 1. Two and Three-phase MagneX.

Surge Arresters. UltraSIL Housed VariSTAR Station Class Surge Arresters GENERAL CONSTRUCTION

Surge Arresters. UltraSIL Polymer-Housed Evolution (10 ka) Surge Arresters. General. Construction. features

Surge Arresters. UltraSIL Polymer-Housed VariSTAR Surge Arresters: Normal-Duty (5 ka), Heavy-Duty (10 ka), and Heavy-Duty Riser Pole (10 ka)

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

NEW Solutions for Underground System Growth

GENERAL INFORMATION POLE MOUNT TRANSFORMER SINGLE PHASE PAD MOUNT TRANSFORMER SINGLE PHASE POLE MOUNT TRANSFORMER THREE PHASE 17

Underground Distribution Switchgear

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Single Phase Overhead Distribution Transformers

Single-Phase Step Voltage Regulators

Substation Transformers

Surge arresters. UltraSIl Polymer-Housed VariSTar Type UI Intermediate-Class Surge arresters. General. COnSTrUCTIOn

Technical Specification for Pole Mounted Capacitor Rack

Single-phase step voltage regulators

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

A 1.2 kv class externally removable secondary bushing

DISTRIBUTION TRANSFORMERS Single-Phase Pad-Mounted

Distribution Transformers

Single-phase pad-mounted step voltage regulator

K-SEC 030. Fusing Equipment. Kearney Fuse Links GENERAL INTERNAL CONSTRUCTION SINGLE TIN ELEMENT

Proudly Made In America

Drive Duty Transformer Specification Virginia Transformer Corp. Power Up! Selecting the Right Transformer

Three-Phase Pole Mounted Recloser

Fusing Equipment. Sidewall-Mounted and Cover-Mounted Bay-O-Net Fuse Assembly GENERAL INSTALLATION

1TSF /CD Attachment B. City and County of San Francisco Office of Contract Administration

UltraSIL polymer-insulated and porcelain loadbreak Type LB open distribution cutout

Effective March 2015 Supersedes S August 2012

Distribution Transformers

UltraSIL polymer-housed VariSTAR station-class surge arresters

Wind Power Solutions. Make Energy Renewable and Reliable!

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

15-kV Live Terminal Primary Metering Station Pad-Mounted Outdoor

D-73P disconnect and bypass switches

Howard Industries. Single-Phase Step

Figure 1. Non-removable buttonhead Edison Links. TABLE 1 Edison Link Fuse Designs. System Fuse Ampere Rating Type Rating

Underground Distribution Switchgear

Make-Before-Break design available in both V- and T-blade switch types. ATTRIBUTES

Single-Phase Step Voltage Regulator

I Surge Arresters. UltraSIL Polymer-Housed VariSTAR Type U3 Surge Arrester for Systems through 275 kv IEC 10 ka; Line Discharge Class 3 GENERAL

Type L Cutouts. UltraSIL Polymer-Insulated and Porcelain Type L Open Distribution Cutout. Description

ELF -LR current-limiting fuse

S Voltage Regulators. Contents. VR-32 Voltage Regulator with Quik-Drive Tap-Changer Installation, Operation, and Maintenance Instructions

Chapter 6 Generator-Voltage System

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

MATERIAL STANDARD ELECTRIC OPERATIONS ORGANIZATION. ****Supercedes BECo Standard E and ComElectric Spec ****

COOPER POWER SERIES. Instructions for oil-filled, single-phase overhead distribution transformers. Distribution Transformers MN201003EN

Compact Integrated Distribution Substation (CIDS)

NXPLUS C Single busbar. Maintenance-free for lifetime

Surge Arresters. Surge Arrester/Type L Fuse Cutout Combination. Description. Construction. Connectors/Brackets

SWITCHGEAR DIVISION PRODUCT PROFILES

Specifications. S&C Power Fuses Types SM- 4, SM-5, SMD-20, and SMD-40 Outdoor Distribution (4.16 kv through 34.5 kv)

1500 kva Pad Mount Transformer GRDY/14400V Primary - 208Y/120 Wye Secondary - Oil Cooled

M-Force three-phase switch

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Substation Transformers

GENERAL. CONSTRUCTION External

GROUP D. Switch & Protective device.

M-Force three-phase switch

Technical Specification For Outdoor Substation Harmonic Filter Banks

INSTALLATION PRODUCTION TESTS

VariSTAR Type AZE station-class surge arresters for systems through 345 kv IEEE certified

35-kV Safefront 200 Amp Primary Metering Station Pad-Mounted Outdoor

Kuhlman Electric Corporation Volt Instrument Transformers

www. ElectricalPartManuals. com SPECIFICATIONS Page 1 of 24 March 24, 2003

H1 H2 H3 X0 X1 X2 X3

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

Solid Dielectric, Three Phase Reclosers CATALOG VS11

Fluid characteristics impact performance capabilities in transformer application

38 kv Bay-O-Net Cartridge and Fuse Assemblies Certified Test Report

www. ElectricalPartManuals. com WeSTinghouse Secondary Unit Substation Transformers (Power Centers) Descriptive Bulletin Page 1

Disconnect & ByPass Switches

Underground Distribution Switchgear

SPECIFICATION FOR THREE PHASE PAD-MOUNT DISTRIBUTION TRANSFORMERS

K-Limiter high ampere Companion II fuse

COOPER POWER SERIES. VR-32 Voltage Regulator with Quik-Drive Tap-Changer Installation, Operation, and Maintenance Instructions

Eaton s Cooper Power Systems

INSTRUCTION MANUAL #103

43-SDMS-01 SPECIFICATIONS FOR

Solid Dielectric Load Break Switch SPECIFICATION. 25kV, 630A, 4 WAYS, 4 WAYS SWITCHED PADMOUNTED VACUUM LOAD INTERRUPTER

Loadbreak Apparatus Connectors

MATERIAL SPECIFICATION ELECTRIC OPERATIONS ORGANIZATION. M3902 ****Supercedes BECo Standard E and ComElectric Spec ****

Unit Substation Transformers 5 and 15 KV Class

High Voltage Bushing Wells for Pad Mounted Distribution Transformers Technical Guide

Specifications. S&C Omni-Rupter Switches Outdoor Distribution (14.4 kv and 25 kv) Conditions of Sale

SECTION PANELBOARDS

Solid Dielectric, Single Phase Reclosers

High-voltage primary bushings installation instructions

Submersible Vacuum Fault Interrupters

Specifications. S&C Alduti-Rupter Switches with Power Fuses Outdoor Distribution (14.4 kv through 46 kv)

Distribution transformers Efficiency over life-cycle

Transcription:

Distribution Transformers Single-Phase Overhead Electrical pparatus 0-0 GENERL ooper Power Systems manufactures a complete line of single-phase overhead-type distribution transformers. Single-phase transformers are available as conventional, protected, step-down, High IL and as autotransformers. These transformers are available in a variety of ratings and meet or exceed the requirements of applicable NSI and NEM standards. Units designed per Rural Utilities Service (RUS) standards are also available. onventional overhead transformers are manufactured in 5-500 kv. The completely self protected (SP) units are rated 5-67 kv. SP transformers have direct connected primary arresters, secondary breakers, and internal primary voltage fuses. This eliminates the need for separately mounted protective devices and installation economy results. Single-phase step-down and autotransformers reduce single-phase distribution voltages to new distribution voltages. Step-down transformers are manufactured in 5-500 kv with dual primary or secondary voltages thru 50 kv IL. utotransformers are manufactured in 67-5000 kv, depending on the ratio between the primary and secondary voltages, and are available with a variety of tap arrangements. Single-phase High IL transformers are manufactured in 5-500 kv and have IL ratings from 00-50 kv. Figure. Single-phase overhead conventional transformer. Figure 3. Single-phase overhead completely self protected transformer. Figure. Single-phase overhead step-down transformer. January 00 Supersedes 3/98 Printed in U.S..

Single-Phase Overhead IRDGURD HNDWHEEL HIGH-VOLTGE USHING RRESTER LIFTING LUGS SEONDRY REKER HNDLE LOW-VOLTGE USHING GROUND STRP OVERLOD SIGNL LIGHT ORE OILS REESSED OTTOM Figure 4. Single-phase overhead transformer.

STNDRD FETURES Meet or exceeds NSI and NEM standards EPRI recommended interlaced core-type design (5-50 kv) Tank coating exceeds NSI 57..3 over with a minimum dielectric strength of 8 kv Tin-plated high- and low-voltage bushing terminals to accommodate aluminum or copper conductors Laser-engraved nameplate Wet process porcelain high-voltage bushings resistant to high-voltage corona Tank grounding provisions Electrical grade mineral oil Heavy-duty lifting lugs and hanger brackets per NSI requirements Visible cover ground on units with cover-mounted bushings Recessed tank bottom that offers protection when sliding over rough surfaces utomatic pressure relief device Polymer low-voltage bushings (5-50 kv) rrester mounting and grounding provisions Internal mark indicates the proper oil level Secondary leads are stamped to ensure proper identification orrosion-resistant cover band Quality System ISO 900 certified OPTIONL ESSORIES Taps either two.5 % above and below; four.5% below; NEM taps or special taps Multiple voltage primaries Externally-operable, tap changer switches for safe operation Externally-operable, multiple voltage switches for safe operation (except auto) High corrosion area protection with extra creep bushings, stainless steel hardware and tanks Handwheel and birdguards R-Temp fluid where less-flammable liquid is required Envirotemp FR3 fluid where less-flammable fluid is required and where superior environmental characteristics are desired over with a minimum dielectric strength of 5 kv over mounted high-voltage bushings for 75 kv IL primary Porcelain low-voltage bushings (RUS) Rural Utilities Service design S/E design Special designs to meet international specifications are also available Drain/sampling valve Pressure vacuum gauge (tank size limitations apply) Filter press connections ase bars for platform mounting Temperature gauge (tank size limitations apply) Liquid level gauge (tank size limitations apply) OPTIONL ESSORIES (STEP-DOWN) Dual primary or secondary voltages thru 50 kv IL Wye or delta connections OPTIONL ESSORIES (HIGH IL) Wye or delta connections PROTETION OPTIONS (Except HIGH IL) Secondary breaker with weak link for secondary fault and overload protection (5-67 kv) (except step-down) Primary weak link fuse urrent-limiting fuse for high interrupting ratings and limiting fault currents Low-voltage distribution class MOV arrester internally or externally mounted (except step-down) Magnex Interrupter (Primary reaker) with isolation link Magnex Interrupter (Primary reaker) with partial range currentlimiting fuse Lightning arresters for primary over-voltage protection: direct connected, normal or heavy duty, metal oxide varistor (MOV) either internal (VariSTR ), or external, VariSTR or VariGP, either polymer UltraSIL or porcelain housing Standard for extra large kv and High-IL: lugs and brackets per NSI requirements up to 4500#. Optional on 50-500 kv and High-IL. 3

0-0 SINGLE-PHSE OVERHED ONVENTIONL kv: 5-500 Primary Voltage: 400-9,90 V Secondary Voltage: 0-600 V TLE Typical Dimensions and Weights 3 95 kv IL and all 50-500 kv 75 kv IL pprox. kv 75 kv IL 95 kv IL 5 kv IL 50 kv IL 75 kv IL 95 kv IL Weight (Ibs.) 5 6 3 4 45 8 7 0 0 0 6 3 4 45 8 7 0 0 5 30 35 46 49 8 7 0 80 5 3 38 48 5 30 0 350 37.5 33 40 5 55 3 0 4 450 50 36 44 5 55 33 5 600 75 39 5 54 57 33 4 8 80 00 40 55 58 6 33 7 3 00 67 47 55 58 6 35 35 37 400 50 54 60 65 68 55 55 39 000 333 56 60 67 70 60 60 4 500 500 58 6 69 7 63 63 44 300 Includes sidewall mount H.V. bushings. Includes radiators. 3 Weights, gallons of fluid and dimensions are for reference only, and not for construction. Please contact ooper Power Systems for exact dimensions. SINGLE-PHSE OVERHED OMPLETELY SELF PROTETED (SP) kv: 5-67 Primary Voltage: 400-9,90 V Secondary Voltage: 0-480 V TLE Typical Dimensions and Weights 95 kv IL 75 kv IL pprox. kv 75 kv IL 95 kv IL 5 kv IL 50 kv IL 75 kv IL 95 kv IL Weight (Ibs.) 5 6 36 4 45 8 7 0 40 0 6 36 4 45 8 7 0 40 5 30 4 46 49 8 7 0 300 5 3 44 48 5 30 0 400 37.5 33 46 5 55 3 0 5 500 50 36 46 5 55 33 6 600 75 39 5 54 57 33 4 30 900 00 40 55 58 6 33 7 34 00 67 47 55 58 6 35 35 40 600 Includes sidewall mount H.V. bushings. Weights, gallons of fluid and dimensions are for reference only, and not for construction. Please contact ooper Power Systems for exact dimensions. 4

0-0 SINGLE-PHSE OVERHED STEP-DOWN & UTO kv: 5-500 (autotransformers available 67-5000 kv) Primary Voltage: 460-46,000 V (60-50 kv IL) Secondary Voltage: 400-4,400 V (60-5 kv IL) STEP-DOWN UTO TLE 3 Typical Dimensions and Weights - Two Winding Step-Down, 3 pprox. kv Weight (Ibs.) 5 44 8 7 55 37.5 5 8 7 650 50 57 8 7 750 75 59 3 7 880 00 59 33 7 000 67 68 4 34 850 50 68 50 34 35 333 73 50 36 950 500 77 65 36 3650 Includes radiators. utotransformers are up to 40% smaller. 3 Weights, gallons of fluid and dimensions are for reference only, and not for construction. Please contact ooper Power Systems for exact dimensions. SINGLE-PHSE OVERHED HIGH IL kv: 5-500 Primary Voltage:,000-46,000 V Secondary Voltage: 0-600 V TLE 4 Typical Dimensions and Weights pprox. Weight (Ibs.) kv 00 kv IL 50 kv IL 00-50 kv IL 00 kv IL 50 kv IL 00 kv IL 50 kv IL 5 46 67 4 30 36 830 00 0 46 67 4 30 36 830 00 5 46 67 4 30 36 830 00 5 46 67 4 30 36 830 00 37.5 60 67 7 33 36 975 50 50 60 67 7 33 36 060 40 75 64 7 30 35 38 375 630 00 64 7 40 35 38 655 97 67 64 77 47 39 40 000 430 50 68 80 55 4 44 500 860 333 76 80 60 4 44 300 3570 500 76 84 63 44 44 4000 4400 Includes radiators. Weights, gallons of fluid and dimensions are for reference only, and not for construction. Please contact ooper Power Systems for exact dimensions. 5

Single-Phase Overhead QULITY ONTROL Single-phase overhead-type transformers manufactured by ooper Power Systems provide outstanding performance. ll ooper transformers pass tests as prescribed by NSI, prior to shipment. ores and coils are designed for high reliability and low field failure rates. The domed cover design in conjunction with the formed cover band provides increased pressure withstand capability, eliminates bushing overhang and improves cover retention. The highvoltage bushing design improves gasket protection and seal. The low-voltage polymer bushing virtually eliminates ultraviolet deterioration with its captured gasket, compression-limiting design. These transformers are designed and manufactured to be corrosion-resistant. Special attention is given to all welded external parts, to avoid potential corrosion problems caused by moisture entrapment. The recessed bottom design, as well as the stainless steel cover band ends, provide corrosion protection in these areas, which are more susceptible to coating damage during handling. ll coating systems exceed NSI 57..3. The Quality System at ooper Power Systems Transformer Products is ISO 900 certified. FLUID OPTIONS Transformers can be filled with standard electrical grade mineral insulating oil, R-Temp fluid, Envirotemp FR3 fluid or other dielectric coolants manufactured by ooper Power Systems. For fire-sensitive locations, the transformer can be filled with R-Temp fire-resistant natural hydrocarbon fluid or Envirotemp FR3 fluid, a fire resistant natural ester-based fluid. Envirotemp FR3 fluid offers the benefit of a seed oil-based dielectric coolant with food grade additives, in addition to increased fire safety over conventional mineral oil. heck with ooper Power Systems for the availability of other dielectric coolants in single-phase overhead transformers. 00 ooper Industries, Inc. Envirotemp, R-Temp, Magnex, VariSTR and VariGP are registered trademarks of ooper Industries, Inc. UltraSIL and FR3 are trademarks of ooper Industries, Inc. P.O. ox 640 Waukesha, WI 5387 www.cooperpower.com 6 Printed on Recycled Paper MI /0