Elevator control valve KV 1P KV 1S. Adjustment and maintenance manual

Similar documents
Maintenance and service manual for elevator control valve

CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

CAUTION: The possible problems and causes are listed in order of likelihood and ease of checking.

CAUTION: The first section of the guide deals with the UP SECTION, while the second deals with the DOWN SECTION.

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

CAUTION: The possible problems and causes are listed in likelihood and ease of checking.

Operating instructions Form no safety definitions

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

PUMP SCPD 56/26 DIN BY-PASS

Instruction manual. Installation requirements. Power Take-Off. Pump mounting: Spline shaft DIN 5462 / ISO 14. Mounting flange ISO 7653-D.

Main Steam Isolation Valves (MSIV) in Nuclear Power Plants with PWR

Troubleshooting the Transmission Hydraulic System

AN EXPLANATION OF CIRCUITS CARTER YH HORIZONTAL CLIMATIC CONTROL CARBURETER

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

Pilot Operated Pressure Relief Valve Series R5V (Denison)

Troubleshooting The Transmission Hydraulic System

CENTRO-MATIC PUMP, MODELS 84050, & 85460

k. Components not properly adjusted. Refer to machine technical manual for proper adjustment of components.

GP-2000 : Trouble Shooting. Cause of problems

Torque Converter, Transmission Pump, Screen And Filter

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

91 \\SERVER\CATALOG 2018\2018 Catalog Rev 1 SHUT OFF BALL VALVE

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

Safety Valve HM-SV Installation, maintenance and startup guide

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

Fisher 657 Diaphragm Actuator Sizes and 87

Operating Instructions

OWNER S TECHNICAL MANUAL

FTM-L SERIES SINGLE OR TWIN DIRECT STEAM MIXER KETTLE COMPLETE WITH HYDRAULIC POWER TILT BRIDGE PARTS AND SERVICE MANUAL

OWNER S TECHNICAL MANUAL. 6336N 2.5kg Grease Kit

Directional Control Valve Series D3W Soft Shift

To ensure proper installation, digital pictures with contact information to before startup.

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Gas Actuated Valve Supplement

Parts List See cover Page

Table 6-1. Problems and solutions with pump operations. No Fluid Delivery

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Type 644 and 645 Differential Pressure Pump Governors

Typical Feed Water Heater Isolation System.

Pressure Compensator Valves Series R5P (SAE Flange Mounted) General Description. Features

TROUBLESHOOTING TABLE

STEERING HYDRAULICS The steering system is a flow amplified, load sensing, hydraulics arrangement.

Servo-operated 2/2-way solenoid valves with isolating diaphragm Type EV222B

Oxiperm C 164 Fully automatic chlorine dioxide processing plant C, -450C,-750C, -1300C, -2500C. Service manual

Service Handbook. High-Pressure Washer Pump

SLM - Sealing Liquid Monitor INSTRUCTIONS FOR USE

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

INSTALLATION & MAINTENANCE MANUAL

TEST CHART. Voltage Supply

INSTRUCTIONS. Fc. -1,<" SERIES ST-261 REGULATING UNLOADER VALVE

Check List for Optimal Filter Performance

VMH. www. delta-elektrogas.com. Safety shut off valves for gas with hydraulic actuator DN65 DN200 EE

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

MP18/SIC & SIO Stacking Valve System Technical Information Manual

INSTALLATION, OPERATION AND MAINTENANCE TECHNICAL MANUAL

Directional Control Valve Series 4D01 (DENISON)

NOTES ON ELEVATOR SYSTEMS

Open Center Compact Valve Custom Installation Guide Rev A

Model SL-12K-A SCISSOR LIFT. wheel alignment model. (11000 LBS / 5000Kg Capacity) INSTALLATION & OPERATION INSTRUCTION (SECOND EDITION)

OPERATOR S MANUAL FOR PICK UP LIFT

I & M Mark 708ME. Ideal Installation. Start-Up Procedure. Installation & Maintenance Instructions for Mark 708 & Motor Actuator

Medium and high pressure pumps

(770) Turning Parts Changers Into TROUBLESHOOTERS!

Instructions. for Installation, Operation and Maintenance of ABO Butterfly Valves, Series 600 and 900

Index. 1. Important safety instructions Overview of the lift Installation instructions Operation instructions 8-9

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Honeywell VV, VP, VB & MS SERIES FOR VQ400M CLASS A VALVES PRODUCT HANDBOOK APPLICATION

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

ICSV3003 SALT AND SPREADER MODULE

Instructor Guide. 215: Elevator: Mechanical Drive Systems Module 4: Hydraulic Drive Systems

Maintenance and Service Instruction

DP3 Pump. 3:1, Air-operated, Oil. General. Operation. Technical Data. Installation R0 10/09. 35a 35b 35c

MP18 Stacking Valve System Technical Information Manual

VQ400M SERIES CLASS A COMBINATION VALVES PRODUCT HANDBOOK APPLICATION

Mark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation

PNEUMATIC POWER CYLINDER

Welker Sampler. Installation, Operation, & Maintenance Manual. Model GSS-4HP

VSD05M-S - SOLENOID OPERATED DIRECTIONAL ANTI-SHOCK VALVES

Hydraulic Winch Assembly Instructions

A408 GB. Pneumatic oil and diesel pumps 1:1

For the most current information, visit the Roadranger web site at

Chapter 10: Valves for Pipe Mounting

Black Teknigas. Powerseat Eco Gas Safety Shut-Off Valve. Technical, Installation and Maintenance Details. WattsIndustries.co.uk

DESCRIPTION 9.4 G 3/4"M

Servo-operated 2/2-way solenoid valves Type EV220A

Maintenance and Repair

Power Train Transmission

Baumann Series Flexsleev Control Valve Instructions

Pressure Control Valves. General Description. Specifications. Ordering Information

Engineering & Design Data

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT

Series PD directly operated solenoid valves

Series PD directly operated solenoid valves

Directional Control Valve Series D3W (Parker), 4D02 (Denison)

Ph: (07) Fax: (07) Pump Manual

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

Directional Control Valve Series D1VW

Transcription:

Elevator control valve KV 1P KV 1S Adjustment and maintenance manual

Elevator control valves KV1P and KV1S General KV 1P is a very simply control valve. It is suitable for small velocities up to 0,16 m/sec. It has one upward and one downward speed. The upward acceleration is smooth and the motor controls the stop. The downward acceleration and speed are adjustable but the deceleration is not. KV1S has adjustable upward deceleration. It is suitable for small velocities 0,16 m/s and under conditions the upward speed can reach 0,4 m/s. They have manometer manual lowering valve downward solenoid and the KV1S upward solenoid. Technical data ΚV1P ΚV1S Supply Pressure range Burst pressure Weight Oil viscosity Max. oil temperature Solenoid voltage AC Solenoid voltage DC Supply Pressure range Burst pressure Weight Oil viscosity Max. oil temperature Solenoid voltage AC Solenoid voltage DC 5-80 l/min (1,3-20 Usgpm) 3-100 bar (74-1500 psi) 500 bar (7500 psi) 1,8 kg 25-60 mm²/sec. at 40 C (15-35 cst. at 120 F) 70 C (158 F) 24 V/1.8A, 42 V/1.0 A 110 V/0.43A, 220 V/0.18 A 12 V/2.0A, 24 V/1.1A 42 V/0.5A, 48 V/0.6A 80 V/0.3A, 110 V/0.25A 196 V/0.14A 5-80 l/min (1,3-20 Usgpm) 3-100 bar (74-1500 psi) 500 bar (7500 psi) 2,3 kg 25-60 mm²/sec. at 40 C (15-35 cst. at 120 F) 70 C (158 F) 24 V/1.8A, 42 V/1.0 A 110 V/0.43A, 220 V/0.18 A 12 V/2.0A, 24 V/1.1A 42 V/0.5A, 48 V/0.6A 80 V/0.3A, 110 V/0.25A 196 V/0.14A pg.1

Hydraulic circuit of KV1P, ΚV1S KV1P D Downward solenoid S Pressure relief valve F Filter 1 By-pass adjustment U Βy-pass valve BV Ball valve 6 Downward acceleration Hand pump H Manual lowering valve HP adjustment 9 Downward speed Hi pressure sensor Y Downward valve DH adjustment KS Slack rope valve Low pressure sensor V Check valve DL pg.2

KV1S Α Upward solenoid S Pressure relief valve F Filter D Downward solenoid U Βy-pass valve BV Ball valve 1 By-pass adjustment H Manual lowering valve HP Hand pump 5 6 9 Upward deceleration adjustment Downward acceleration adjustment Downward speed adjustment KS Slack rope valve DH Y Downward valve DL V Check valve Hi pressure sensor Low pressure sensor pg.3

KV1P speed diagram KV1S speed diagram pg.4

KV1P and KV1S adjustments The only difference between KV 1P and KV 1S is one adjustment and one solenoid. Usually they need only a small adjustment during installation. We will refer to the safety and working adjustments. Only qualified persons should adjust the valves. We can see in the following picture the valves and the regulators. KV1P KV1S Pressure relief valve- regulator S The S valve regulates the maximum working pressure. By closing the ball vale we can see in the manometer the maximum working pressure. By unscrewing the regulator S the pressure drops after opening the manual-lowering valve. By screwing the regulator the pressure rises. We suggest that the maximum working pressure does not exceed more than 5 bar the maximum load pressure. Never close the ball valve sharply when the pump is working. KS Slack Rope Valve The KS is adjusted with a 3 mm Socket Key by turning the screw K 'in' for higher pressure and 'out' for lower pressure. With K turned all the way 'in', then half a turn back out, the unloaded car should descend when the D solenoid alone is energized. Should the car not descend, K must be backed off until the car just begins to descend, then backed off a further half turn to ensure that with cold oil, the car can be lowered as required. pg.5

By-pass valve, regulator 1 Regulator 1 determinates the time that the oil is returning to the tank after the pump. It happens so the motor starts without load and the necessary time is about 1 sec. Screwing the regulator the by-pass time becomes smaller and unscrewing it becomes longer. Upward deceleration valve, regulator 5 (KV1S) Regulator 5 adjusts the deceleration during the upward stop. Screwing the regulator the deceleration becomes smoother and unscrewing it becomes rougher. In order to pre-adjust we disconnect the solenoid A with the pump working, then we screw the regulator until the car starts to move. Then we unscrew slowly until the car stops. Downward acceleration valve, reguletor 6 Regulator 6 determinates the elevators downward acceleration. Screwing the regulator the deceleration becomes smoother and unscrewing it becomes rougher. In order to pre-adjust we screw all the way in the regulator with the solenoid D working, the car stops, then we unscrew slowly until the car starts to move. Downward valve, regulator 9 Regulator 9 determinates the downward speed. Screwing the regulator the speed becomes smaller and unscrewing it becomes faster. pg.6

KV Elevator Control Valve Trouble-Shooting Problems in up travel Elevator valves KV P S Problem Possible cause Recommended 1. Screw all the way in the adjustment 5 if the elevator starts the problem is in the coil A. 2. Solenoid Α not working or the voltage is too low. Check solenoid Α. 3. The AR tube of the solenoid Screw tight the tube. No Up-Start (Elevator remains at floor) A is not screwed down tight. 4. Solenoid valve A - dirt or damage between needle and seat Clean or replace needle and seat 5. Adjustment 1 too far back With the pump running, turn (open). adjustment 1 in. 6. Relief valve S is set too low. Set relief valve higher. 7. Down valve 7 or 9 is open due to contamination in its orifice.(especially if the Replace down valves 7 (KV2 elevator settles back on the only) and 9. buffers after pump is stopped). 8. Solenoid D is leaking. Clean solenoid D. 9. Pump running in the wrong Install the pump correct. direction. 10. The pump connection flange Seal the pump connection. is leaking excessively. 11. The pump is undersize or Select bigger pump or replace worn. pump. 12. Test: If by turning adjustment 1 with the pump running the pressure does not rise above 5 bar, even with a smaller bypass valve inserted, the problem should be sought at the pump. 13. Test: Turn restriction 3 all the way in. If the elevator now travels with full speed, the cause is the energy. Up-Start, but no Full Speed 14. Solenoid C not energized or voltage too low 15. Dirt or damage in solenoid C or solenoid tube not pulled up tight. 16. Solenoid valve B - dirt or damage between needle DΝ and seat S6. Check solenoid C. Clean solenoid C or pull tighter. Clean or replace needle and seat pg.7

Problem Possible cause Recommended 17. Adjustment 1 turned in too far. Turn out adjustment 1. 18. Bypass flow guide U too small (slots too narrow) Change to flow guide with wider slots. Up-Start too hard 19. Star to delta motor switch period is too long. 0.2-0.3 sec. is sufficient. 20. UO O-ring on the by-pass valve U is leaking. Change O-Ring (see KV Spare Parts List.) 21. Excessive friction on the Cannot be eliminated through guide rails or in the cylinder valve adjustment. head. 22. Solenoid A (Up-stop) is deenergized too late. Check solenoid Α. 23. Adjustment 5 (Soft Stop) not Elevator slows far enough open. down but travels Open further out. floor level. Relief-Valve not adjustable to lower value. 24. Adjustment 1 (By-pass) not far enough open and pump flow does not completely by-pass. Open adjustment 1 two turns further out. 25. Adjustment 1 too far in. Open adjustment 1 further out. 26. ½ pipe thread connection in With tape threads, 4-6 threads return line T should not of engagement are sufficient. exceed 14 mm. pg.8

Problems in down travel Problem Possible cause Recommended 27. Solenoid D not energized or Check the solenoid D. voltage too low. No Down Start 28. Adjustment 6 turned in too (Elevator remains Unscrew the adjustment 6. far. at floor) 29. O-ring XO on down valve, Replace the O-Ring (see ΚV leaking. parts list). 30. Solenoid C not energized or KV2 only: Down Check the solenoid C. voltage too low. start but no full speed 31. Adjustment 7 (Full speed Unscrew the adjustment 7. down) turned in too far. 32. Solenoid D not energized Check the solenoid D and the (possibly solenoids C and D connection reversed KV2 only: Down full speed but no down reveling Elevator travels through the lower floor. Leakage (Elevator sinks away from floor). 33. Adjustment 9 (Down leveling speed) turned in too far. 34. Down flow guide too small (slots too narrow) 35. KV2 only: Down leveling speed 9 too fast. 36. Solenoid Valve C leaking at needle. Dirt or wear between the needle DΝ and the seat S6. 37. Orifice in flow guide contaminated. 38. Leak at DN, XO, VO, WO or HO. 39. Other valve or hand pump in system leaking. 40. Contraction of oil during cooling especially from above 35 C. Unscrew the adjustment 9. Change flow guide. Adjust to between 6 and 10 cm/sec. Clean or change needle and seat. Replace flow guide. Replace and test in sequence. Where possible, isolate and check. Consider oil cooler to keep oil temperatures down. pg.9

Down leakage In case of down leakage change one part at the time according to the mentioned sequence and check, if the leakage doesn t stop continue to the next step etc. pg.10

Adjustment of rupture valve R10 Blain We suggest that the rupture valve should shut off the oil s flow when the lowering speed of the elevator becomes 0,1 m/sec higher than the nominal. To find the cut off flow: Q c = (v + 0,3) * Q / v V the elevator s speed Q the nominal speed of the pump Example: v = 0,16 m/sec Q = 55 l/min Q c = (0,16 + 0,1) * 55 / 0,16 = 89 l/min To adjust the rupture valve we use the following diagram, for the example above the h must be set on 22 mm pg.11