Generator Quick Connection Tap Box WM Series

Similar documents
Generator/Loadbank Quick Connection Tap Box

Solar Power Switchgear & Energy Storage Renewable Energy Systems

Single pole connectors

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

C1000 Series Automatic Cap Bank

MP Meter-Pak Meter Centers Product Description PRODUCT DESCRIPTION. MP Meter-Pak Meter Centers

A. Submit manufacturer's literature and technical data before starting work.

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

30 Years of Innovative Solutions for Construction & Industry

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

Application guide. Tmax Link OEM UL 891 Switchboard Program

6.2. Power Pedestals. Contents

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

Cam-Lok. Single pole connectivity. The industry standard for reliable service under the most severe operating conditions.

Posi-Lok Plugs and Panels

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Cam-Lok Single Pole Connectors

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Roughneck Single- Conductor Connectors. The ultimate performance solution, built to take heavy abuse under the most extreme conditions.

5.2. Power Pedestals. Contents Description

Publication No.: PSG

Data Bulletin. Wire Temperature Ratings and Terminations INTRODUCTION WHY ARE TEMPERATURE RATINGS IMPORTANT?

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

CLEAVELAND / PRICE INC. Type RL-C Side Break Switch kv A. Bulletin DB-104E12

Pow-R-Line 3E Panelboard

SECTION PANELBOARDS

CTN QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473. Two-Hole NEMA CTN QTY

SWITCHGEAR DIVISION PRODUCT PROFILES

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

CANADIAN BROCHURE Enclosed Circuit Breakers Tmax Range

Busway Construction. Bus Bars

Generator Fire Safety: Generator assemblies should be located outside the building.

Options: PART NUMBER MAIN BREAKER PHASE VOLTAGE

AMENDMENT ELECTRIC SERVICE MANUAL 2014

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

MEH Series Sectionalizing Enclosures. Single-Phase and Three-Phase

CTN U-TYPE DIE COLOR INDEX QTY 7/374 8/346 11/375 12/ /298 18/324 19/470 20/299 22/472 24/473 CTN U-TYPE DIE COLOR INDEX QTY

Easy assembly with standard tools. Fully insulated for direct mounting to steel panels

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Quick Connection Panel (QCP) Installation Guide

Chapter 6 Generator-Voltage System

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Accessories. Accessories. Meter Mounting Equipment

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

University of Houston Master Construction Specifications Insert Project Name

Contents. Power Outlet. Don t Give Up! If you don t find the product you want in this catalog, try the Flex Center at

BETA Switching Switches and Light Indicators

Applications. Trim are flat gauge steel per code. Standard painted finish ANSI 61 gray. Directory card with plastic cover on front of trim

BUSWAY Low Voltage (Pow-R-Flex)

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

SECTION SECTION. EATON 2014 Arrow Hart Buyers Guide

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Contents. Volume 1 Residential and Light Commercial CA E December

MEG Approval Meter Equipment Group

Overview for Fusible Disconnect Switches

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Lighthouse-SS Power Pedestals

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

MP Meter-Pak Meter Centers

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

CP3B11115A22 Comm Metr PDSTL. Descriptions. Manufacturer Information. Packaging Carton 1 Weight Per each 0. Weight per unit

Power-Trex. Family of Products for Temporary & Emergency Power

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Quik-Spec Electrical Gear

Service Entrance Methods

9. Non-Residential Services (Commercial, Industrial, and Agricultural)

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

W Series Cast Junction Box Options Boxes Available for Raintight, Watertight, or Submersible Applications

Eaton Corp. - Marina Power and Lighting, Inc. General Specifications for Hatteras Light Pedestals

Low Voltage Automatic Transfer Switch Systems

PSC Terminations. Features Class 1 (outdoor) termination as defined in IEEE 48 standard. For use on all extruded dielectric cables.

Switchboard MaxSB. Low Voltage Products and Systems. Power. Distribution Systems

Design Standard. Purpose: Design Standard:

Duke/MEG Approval Meter Equipment Group

SIRCOVER UL1008/98 Changeover switches standards UL and CSA 100 to 1200 A

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

TYPE BLT DISCONNECT SWITCHES

Critical Power Switchboards. Selection and Application Guide

Design Guide for Integration of Fixed-Mount Circuit Breakers

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

SIRCO M UL 508 Non-fusible disconnect switches standards UL and CSA from 16 to 100 A

750 kva Transformer V Delta Primary Voltage - 480Y/277 Wye-N Voltage Secondary - NEMA 3R

Typical Specification

Standard switch modules (type WS) are designed for flexibility, space savings, & durability.

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Panelboards and Lighting Control. Types PRL1a, 2a, 3a, 3E, 4 and Column Modifications. Contents Description

Switchgear Skid, C1192

Transcription:

Generator Quick Connection Tap Box WM Series Product Line Brochure www.apt-power.com 433 N. 36 th Street www.apt-power.com 433 North 36 th Street, Lafayette, Indiana 47905 Lafayette, IN 47905 Tel. 765-446-2343 765-446-2343

2 Standard Configuration Figure 1: Carbon Steel NEMA 3R Enclosure Inside Access Figure 3: Mechanical lugs on silver plated copper bus bars (Top) with Cam-lok Cover (Left) and Male Cam-lok Receptacle (Right) Figure 2: 1200A No Circuit Breaker (Inside Cover Removed) 400 4000A, 480V (3Ø) No Circuit Breaker Tap Box Wall-Mountable Rating: 400 4000A, 120/208-480V (3Ø) Color coded, male Cam-lok E1016 compatible single pole receptacles with cover. o A phase Brown o B phase Orange o C phase Yellow o Neutral White o Ground Green Silver plated copper bus with 1000A/in 2 current density connects the permanent facility load feeders to industry standard Cam-lok E1016 compatible receptacles. NEMA standard hole pattern for permanent facility side connection. Enclosure o UL 50 Listed. o NEMA 3R for outdoor installation. o Carbon steel. o Powder coated ANSI 61 Gray. o Corrosion resistant hardware. o Padlockable front door. o Integral lower flip door allowing access to connect the mobile generator cables. o Bottom door mechanically interlocked with front door to prevent unauthorized access to receptacles when not in use. o Typical Dimensions 36"H x 30 W x 16 D

3 Build Your Own with Optional Features APT understands there is not a one size fits all for your power distribution needs. Generator Quick Connection Tap Boxes are customer customizable to suit your facility s needs. Circuit Breaker Cam-lok Style Receptacles Figure 4: 800A with Circuit Breaker (Inside Cover Removed) Lower Flip Door (Kirk Key Interlocked with Circuit Breaker) Figure 5: GQC Tap Box Wall-Mount to Pad-Mount Conversion Stand Standard Optional Features Mechanical lugs for permanent facility side connection. Circuit Beaker o Rating: 400 3000A, 480V Kirk Key Interlocking schemes to prevent inadvertent paralleling of two sources. 1. Interlocking between bottom flip door and facility main circuit breaker*. 2. Interlocking between tap box circuit breaker and facility main circuit breaker*. 3. Interlocking between tap box circuit breaker and bottom flip door for service entrance units. o * Requires a ship loose matching lock for installation on customer s equipment. Phase Rotation Monitoring includes: o Insures mobile generator set phase rotation matches that of facility. o Provides visual assurance of correct phasing. o Prevents circuit breaker from being closed if phase rotation is incorrect. Wall-Mount to Pad-Mount Conversion Stand o 3/16 Formed Steel Construction o Bolt together design for easy factory or field assembly o Designed to withstand Category 5 Hurricane force winds (Up to 190MPH) o Galvanized or Powder Coated Finishes Available Contact APT factory to discuss any further site specific requirements including: o Generator Quick Connection Switchboard o Automatic Load Transfer o Distribution Switchboards o Service Entrance Rated o Load Shed Contacts o Generator Paralleling o 5kV 15kV Applications o And more!

4 Pricing Information Table 2: Standard Product Configuration Budgeting Prices Base Part Number Approx. Generator Rating @ 480V (kw@0.8pf, MVA) Current Rating Without Circuit Breakers With Circuit Breakers Maximum # of Cables Per Phase and Neutral Cam-loks/Phase (Temporary Generator Side) Mechanical Lugs Available/Phase (Permanent Facility-Side)* Base Budget Price** (USD $) APN1583 250kW, 0.33MVA 400A 400A 1 2 $4,580.00 APN1584 500kW, 0.67MVA 800A 800A 2 4 $4,890.00 APN1585 750kW, 1.00MVA 1200A 1200A 3 6 $5,200.00 APN1586 1000kW, 1.33MVA 1600A 1600A 4 8 $5,500.00 APN1632 1250kW, 1.67MVA 2000A 2000A 5 10 $5,850.00 APN1633 1500kW, 2.00MVA 2400A 2500A 6 12 $6,150.00 *NEMA standard 9/16 holes are provided in the copper bus for the permanent side connection to accommodate NEMA standard 1-hole lugs. Maximum number of cables shown assumes one cable per lug. **Base Budget Prices are representative of the standard product configuration which does not include a circuit breaker. One (1) Optional APT mechanical lug (APN1587) accommodates Two (2) #1/0 AWG - 300kcmil AL/CU cables or One (1) #1/0 AWG - 750kcmil AL/CU cable; therefore, more cables per phase can be connected if needed. Table 3: Permanent Facility Side Lugs Budgeting Price Table Part Number Product Base Budget Price/ Lug (USD $) APN1587 Mechanical Lug $17.00 Figure 6: 800A with Circuit Breaker (with Inside Cover) Figure 7: 800A Bottom Flip with Kirk Key Interlock Door Open

5 Typical Dimensions of GQC Tap Boxes

6 GQC Tap Box Pad-Mount Conversion Stand

7 GQC Tap Box Part Number The Generator Quick Connection Tap Box WM-Series has been designed to provide maximum functionality at a minimum price. Although we offer many options, you only need to select what your facility needs. Please build the part number of the product you would like quoted and contact APT so that a representative can quickly and efficiently quote to your needs. Base Size Option Number BPN A ET EM MT CB KK MO ML Example: APN1583 G 3R CS 0 0 0 0 1 Your P/N: Base Part Number Enclosure Type Mounting (APN1583) - 400A (01) - NEMA 1 (0) - Wall Mount (0) - None Kirk Key Interlocking (APN1584) - 800A (3R) - NEMA 3R (1) - Pad Mount (1) - Bottom Flip Door & Main CB, Ship Loose Lock (APN1585) - 1200A (APN1586) - 1600A (APN1632) - 2000A (APN1633) - 2400A (APN1682) - 2800A (APN1683) - 3200A (CUSTOM) - 4000A (2) - Tap Box CB & Main CB, Ship Loose Lock (3) - Tap Box CB & Bottom Flip Door (SER only) Application Enclosure Metal # of Circuit Breakers Monitoring (G) - Generator (CS) - Carbon Steel (0) - None (0) - None (0) - No (L) - Loadbank (SS4) - 304 Stainless Steel (1) - 1 CB (1) - Phase Rotation Only (1) - Yes (S) - Service Entrance Rated (SS6) - 316 Stainless Steel Mechanical Lugs