Pressure sequence valve, direct operated

Similar documents
Pressure sequence valve, direct operated

Pressure relief valve, pilot operated

Check valve, pilot operated

Pressure relief valve, pilot operated

Pressure reducing valve, direct operated

Pressure reducing valve, pilot operated

2-way flow control valve

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated, with pressure monitoring

Pressure relief valve, directly operated

Meter-in pressure compensator, direct operated

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Pressure reducing valve, pilot operated Type DR

3/2 and 4/2 directional poppet valve with solenoid actuation

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Throttle and throttle check valve

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Pressure reducing valve, direct operated

RC /

Pressure reducing valve, direct operated

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Throttle and throttle check valve

Double throttle check valve Type Z2FS 10

Supply pressure compensator, direct operated

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

Twin throttle check valve

Pressure relief valve, pilot operated

2-way flow control valve

Check valve, pilot operated

Throttle and throttle check valve

Hydro-electric pressure switch

Proportional pressure reducing valve, pilot operated

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Proportional pressure reducing valve, 3-way variant, pilot operated

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Filling valve sandwich plate

Pressure relief valve, pilot operated

Pressure reducing valve, direct operated

Check valve, pilot operated

Check valve, pilot operated

Proportional pressure reducing valve, pilot operated

Check valve, pilot operated

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Winch control block. RE 65051/08.04 Replaces: Type YM-WCB

Check valve cartridge Type M-SR

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Directional spool and seat valves with electrical actuation and M12x1 plug-in connection

Proportional pressure reducing valve, pilot operated

Pressure relief and feed valve, pilot operated. Type MHDBN. Features. Contents. RE Edition: Replaces:

Proportional pressure relief valve, directly operated, rising characteristic curve

3/2 and 4/2 directional seat valves with solenoid actuation

Proportional flow control valve, with integrated pressure compensator

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Directional servo-valve of 4-way design

Pressure relief valve, pilot-operated. Type DB and DBW. Features. Contents. RE Edition: Replaces:

Bourdon tube pressure switch with infinitely variable switching pressure differential

Accumulator shut-off block. Type 0532VAW. Contents. Features. RE Edition: Replaces: 07.10

4-way directional servo-valve

Proportional pressure reducing valve, pilot operated. Type DRE(M) and DRE(M)E. Features. Contents. RE Edition: Replaces: 11.

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Proportional directional valves, pilot operated, with electrical position feedback and integrated electronics (OBE)

4/3-way high response directional control valve pilot operated with electrical feedback and integrated electronics (OBE)

Reservoir oil filler/breather

3/2 directional spool valve, direct operated with solenoid actuation

3/2 and 4/2 directional seat valves with solenoid actuation

2/2 directional seat valve, direct operated with solenoid actuation

Bourdon tube pressure switch with infinitely variable switching pressure differential

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

4/4 directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Proportional flow control valve, 2-way version

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13

2/2-way poppet valves with solenoid operation Type KSDER1

3/2 and 4/2 directional seat valves with solenoid actuation

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRDE. Contents.

Directional servo-valve in 4-way design

Proportional flow control valve. Type 2FRE. Features. Contents. RE Edition: Replaces: 02.07

Safety valves, directly operated

2-way proportional throttle valve for block installation

Throttle check valve. Type Z2FS. Size 16 Component series 3X Maximum operating pressure 350 bar [5076 psi] Maximum flow 250 l/min [66 US gpm]

Rexroth Hydraulics. Pressure reducing valve, pilot operated, type 3DR 3DR 10 P 6X Y 00 RE /10.97

Proportional directional valve, pilot-operated, with integrated electronics (OBE)

Proportional pressure reducing valve, pilot operated

Directional control valves, pilot-operated, with electrical position feedback and integrated electronics (OBE) Type 4WRTE. Features.

3/3 servo directional control valve with mechanical position feedback

Directional control valves, direct operated, with electrical position feedback and integrated electronics (OBE)

Directional spool valves, direct operated, with solenoid actuation. Type WE. Features. Contents. RE Edition: Replaces: 04.

Proportional pressure relief valve, pilot operated

Check valve. Type Z1S. Contents. Features. RE Edition: Replaces: 09.10

4/3 directional control valve, pilot operated, with electric position feedback and integrated electronics (OBE)

Proportional pressure reducing valve, in 3-way version

Single-circuit power brake valve LT 05

Transcription:

Courtesy of C/Flodyne/Hydradyne otion Control Hydraulic neumatic Electrical echanical (800) 426-5480 www.cmafh.com ressure sequence valve, direct operated Type DZ 6 D Nominal size 6 Series 5X aximum operating pressure 315 bar aximum flow 60 l/min Overview of contents Contents age Features Order code 2 referred types 2 Symbols 2 Function, section 3 Technical data 4 Characteristic curves 4 Unit dimensions 5 Informationen zu lieferbaren Ersatzteilen: www.boschrexroth.com/spc Features RE 26076/04.07 Replaces: 02.03 K 4297-9 /6 For subplate mounting Connection location to DIN 24340 form (without locating bore), (standard) Connection location to ISO 4401-03-02-0-05 (with locating bore), (ordering code.../60) Subplates see catalogue sheet RE 45052 (separate order) 5 pressure stages 4 adjustment elements, optional: Rotary knob Set screw with hexagon and protective cap Lockable rotary knob with scale Rotary knob with scale Check valve, optional

2/6 Bosch Rexroth G Hydraulics DZ 6 D RE 26076/04.07 Courtesy of C/Flodyne/Hydradyne otion Control Hydraulic neumatic Electrical echanical (800) 426-5480 www.cmafh.com Order code ressure sequence valve NG6, direct operated djustment element Rotary knob = 1 Set screw with hexagon and protective cap = 2 Lockable rotary knob with scale 1) = 3 Rotary knob with scale = 7 Series 50 to 59 = 5X (50 to 59: unchanged installation and connection dimensions) ax. sequence pressure 25 bar = 25 ax. sequence pressure 75 bar = 75 ax. sequence pressure 150 bar = 150 ax. sequence pressure 210 bar = 210 ax. sequence pressure 315 bar = 315 2) 1) H-key with aterial No. R900008158 is included within the scope of supply. 2) Only with adjustment element 2 and without check valve 3) Locating pin ISO 8752-3x8-St, aterial No. R900005694 (separate order) Standard types Type DZ 6 D2-5X/25Y DZ 6 D2-5X/75Y DZ 6 D2-5X/150Y DZ 6 D2-5X/210Y DZ 6 D2-5X/315Y Symbols DZ 6 D 5X * aterial number R900403077 R900481060 R900481061 R900481062 R900513984 No code = /60 3) = Further details in clear text without locating pin hole with locating pin hole Seal material No code = NBR seals V = FK seals (other seals on request) ttention! The compatibility of the seals and pressure fluid has to be taken into account! No code = = with check valve without check valve No code = Internal pilot oil supply, internal leakage oil drain X = External pilot oil supply, internal leakage oil drain Y = Internal pilot oil supply, external leakage oil drain XY = External pilot oil supply, external leakage oil drain referred types and standard components are highlighted in the RS (Standard rice list). Version No code Version X Version Y Version XY B (X) T (Y) B (X) T (Y)

RE 26076/04.07 DZ 6 D Hydraulics Bosch Rexroth G 3/6 Courtesy of C/Flodyne/Hydradyne otion Control Hydraulic neumatic Electrical echanical (800) 426-5480 www.cmafh.com Function, section The valve type DZ 6 D is a direct operated pressure sequence valve. It is used for the pressure dependent connection of a second system. The setting of the sequence pressure is via the adjustment element (4). The compression spring (3) holds the control spool (2) in its initial position, the valve is closed. The pressure in port is applied to the piston area of the control spool (2) via the control line (6) at the opposite side to the spring (3). When the pressure in port reaches the set value of the spring (3), then the control spool (2) is moved to the left and the connection to is opened. The system connected to port is connected without a pressure decrease occuring in port. Type DZ 6 D1 5X/ Type DZ 6 D1 5X/.XY The control signal originates internally via the control line (6) from port or externally via port B (X). Depending on the use of the valve the leakage oil drain is externally via port T (Y) or internally via. ttention! With internal leakage oil drain the set opening pressure increases by the pressure present in port. For the free return of the pressure fluid from port to port a check valve (5) may optionally be installed. pressure gauge port (1) enables the monitoring of the sequence pressure set at the valve. 4 3 2 5 6 1 T (Y) T (Y) B (X) 4 3 2 1 B (X)

4/6 Bosch Rexroth G Hydraulics DZ 6 D RE 26076/04.07 Courtesy of C/Flodyne/Hydradyne otion Control Hydraulic neumatic Electrical echanical (800) 426-5480 www.cmafh.com Technical data (for applications outside these parameters, please consult us!) General Weight kg pprox. 1.2 Installation mbient temperature range 1) Suitable for NBR and FK sesals 2) Only suitable for FK seals 3) The cleanliness class stated for the components must be adhered too in hydraulic systems. Effective filtration prevents 350 300 250 200 150 100 50 0 10 20 30 40 50 60 Flow in l/min C Optional 30 to +80 (NBR seals) 20 to +80 (FK seals) Hydraulic aximum operating orts,, B (X) bar 315 pressure orts T (Y) bar 160 aximum sequence pressure (adjustable) bar 25; 75; 150; 210; 315 aximum flow l/min 60 ressure fluid ineral oil (HL, HL) to DIN 51524 1) ; Fast bio-degradable pressure fluids to VD 24568 (also see RE 90221); HETG (rape seed oil) 1) ; HEG (polyglycols) 2) ; HEES (synthetic ester) 2) ; other pressure fluids on request ressure fluid temperature range C 30 to +80 (NBR seals) 20 to +80 (FK seals) Viscosity range mm 2 /s 10 to 800 ax. permissible degree of contamination of the hydraulic fluid cleanliness class to ISO 4406 (c) Class 20/18/15 3) Characteristic curves (measured with HL46, ϑ oil = 40 C ± 5 C) Sequence pressure in bar p-q V -characteristic curves The characteristic curves are valid for the output pressure = zero over the entire flow range faults from occurring and at the same time increases the component service life. For the selection of filters see catalogue sheets RE 50070, RE 50076, RE 50081, RE 50086, RE 50087 and RE 50088. ressure differential in bar 25 20 15 10 5 p-q V -characteristic curves 0 10 20 30 40 50 60 Flow in l/min 1 via check valve, flow from to 2 to 1 2

RE 26076/04.07 DZ 6 D Hydraulics Bosch Rexroth G 5/6 Courtesy of C/Flodyne/Hydradyne otion Control Hydraulic neumatic Electrical echanical (800) 426-5480 www.cmafh.com Unit dimensions (dirmensions in mm) Ø40 6 4 5 1 12 18 0,01/100 Rzmax 4 Required surface quality of the mating part 1 Name plate 2 djustment element 1 3 djustment element 2 4 djustment element 3 5 djustment element 7 Ø35 5 4 3 2 1 189 2 84,5 12,5 11 Ø39 6 Space required to remove the key 7 Valve fixing holes 8 Locknut 24/F 9 Hexagon 10/F 10 Same seal rings for ports, B(X),, T(Y) 11 ressure gauge connection G1/4; 12 deep; internal hexagon 6/F 12 Without check valve 13 With check valve 3 2 1 233 209 189 3 13 Ø32 9 8 14 10 7 26 14 Connection location to DIN 24340 Form (without locating bore), or ISO 4401-03-02-0-05 (with locating bore for locating pin ISO 8752-3x8-St, aterial No. R900005694, order separately) Subplates to data sheet RE 45052 (order separately) (without locating bore) G 341/01 (G1/4) G 342/01 (G3/8) G 502/01 (G1/2) (with locating bore) G 341/60 (G1/4) G 342/60 (G3/8) G 502/60 (G1/2) F1 F4 T(Y) G 39,5 F2 B(X) F3 50 20 40 45 41 4 x Ø5,4 52,5 Valve fixing screws (order separately) 4 socket head cap screws (SHCS) ISO 4762-5 x 50-10.9-flZn-240h-L friction coefficient μ total = 0.09 bis 0.14, tightening torque T = 7 Nm ± 10%, material number R913000064 ipe thread (G..) to ISO 228/1 7

6/6 Bosch Rexroth G Hydraulics DZ 6 D RE 26076/04.07 Courtesy of C/Flodyne/Hydradyne otion Control Hydraulic neumatic Electrical echanical (800) 426-5480 www.cmafh.com Notes Bosch Rexroth G Hydraulics Zum Eisengießer 1 97816 Lohr am ain, Germany hone +49 (0) 93 52 / 18-0 Fax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth G. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

RE 26076/04.07 DZ 6 D Hydraulics Bosch Rexroth G 7/6 Courtesy of C/Flodyne/Hydradyne otion Control Hydraulic neumatic Electrical echanical (800) 426-5480 www.cmafh.com Notes Bosch Rexroth G Hydraulics Zum Eisengießer 1 97816 Lohr am ain, Germany hone +49 (0) 93 52 / 18-0 Fax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth G. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

8/6 Bosch Rexroth G Hydraulics DZ 6 D RE 26076/04.07 Courtesy of C/Flodyne/Hydradyne otion Control Hydraulic neumatic Electrical echanical (800) 426-5480 www.cmafh.com Notes Bosch Rexroth G Hydraulics Zum Eisengießer 1 97816 Lohr am ain, Germany hone +49 (0) 93 52 / 18-0 Fax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth G. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.