Synchronous condenser solutions siemens.com/energy/facts

Similar documents
The Smart Way. HVDC PLUS One Step Ahead. Answers for energy.

Comprehensive solution with SIHARBOR

SGT-2000E gas turbine series

SGT-2000E gas turbine series

High-current and generator switchgear from Siemens siemens.com/generatorswitchgear

3TM Vacuum Contactors

SIGENTICS HV Series S-modyn

We power the world with innovative gas turbines

The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw

Control & monitoring system for Siemens gas engines & gen-sets siemens.com

Reliable, economical and safe siemens.com/rail-electrification

Shunt reactors Proven history for future success

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

Siemens Power Rectifiers powering your industrial copper and zinc electrolysis siemens.com/mining

Trusted technology for maximum power yield SINAMICS W180 siemens.com/sinamics-w180

ABB Group August 27, 2010 Slide 1

Pathways to the global grid Answers for energy.

Power Transmission Solutions Grid Access

Beyond 60% - Pioneering H-class Efficiency with World Class Flexibility

Small step, big impact: Energy efficiency and dynamic performance

Life Needs Power, Hannover Messe 2017 Inertia in Future Electrical Power Systems Challenges and Solutions Dr. Ervin Spahic

ABB Wind Power Solution

Bright outlook for improved profitability. Direct drive wind turbine SWT Answers for energy.

CHAPTER 6 DESIGN AND DEVELOPMENT OF DOUBLE WINDING INDUCTION GENERATOR

Modular Standardized Electrical and Control Solutions for Fast Track Projects

ABB in Wind &Integration of renewables

Agility in energy Ahead of the challenge, ahead of the change

Comprehensive Technical Training

SIMINE DRAG. Innovative solutions for maximum productivity and reliability. Mining Technologies

TURBO GENERATORS BEST QUALITY FOR THERMAL POWER PLANTS

Experience on Technical Solutions for Grid Integration of Offshore Windfarms

AT A GLANCE GRID /2014

Electrical Power Systems 2014/15

Diversifying into Marine Energy. ABB March 2015

Grid Stability Analysis for High Penetration Solar Photovoltaics

When grids get smart ABB your partner for developing Smart Grids solutions

Annex A-4 DIESEL UNITS INDEX TO SYSTEM/COMPONENT CAUSE CODES BALANCE OF PLANT GENERATOR DIESEL ENGINE

SYSTEM INTEGRATION. Railway and urban transport electrification Energy-efficient and reliable solutions

Gas-insulated switchgear from 72.5 to 550 kv. Excellent systems that create lasting value. siemens.com/energy-management

Grid Integration of Large Scale Wind and Solar

Shoreside power supply. Intelligent solutions for berthed ships based on SIHARBOR / SIPLINK medium-voltage systems. Answers for Energy.

Efficient & Reliable Power Delivery

Possibilities of Distributed Generation Simulations Using by MATLAB

Dynamic Control of Grid Assets

Power Transmisson Division Erlangen, April 15, Siemens receives major order for BorWin3 North Sea grid connection from TenneT

DC RSB efficiency with DC technology. Integration in industry, renewable energies, and infrastructure

The Smart Way HVDC PLUS One Step Ahead Answers for energy.

ELG4125: Flexible AC Transmission Systems (FACTS)

The SGT5-8000H proven in commercial operation

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Lower Operating Costs Higher Availability.

The 1,400-MW Kii-Channel HVDC System

Product Environmental Declaration according to ISO Type II siemens.com/mobility

Workshop on Grid Integration of Variable Renewable Energy: Part 1

Offshore Wind: Grid Connection & Technology Options. Dietmar Retzmann Focus on. CO 2 Reduction Green Energy Megacities Security of Supply

Lesson 16: Asynchronous Generators/Induction Generators

Just as precise as your motion control application siemens.com/servo-geared-motors

POWER QUALITY SOLUTIONS FOR INDUSTRIAL AND DISTRIBUTION GRIDS. W WW.R EINHAU S EN.COM

Use of High-Power Thyristor Technology for Short-Circuit Current Limitation in High Voltage Systems

CMU Electricity Conference, 9th March 2011

Power Quality innovative SolutionS for industrial and distribution grids.

GE Energy. Variable Frequency Transformers Grid Inter-tie

Unit Protection System for Pumped-Storage Power Stations

Ukujima Photovoltaic Park 400 MW Stable Integration of a 400MW Photovoltaic Farm into the Japanese Power System Challenges and Chances

SINAMICS S120 Cabinet Modules Application Shaft Generator Drive

Reliability is our profession

9. Examples of hydro energy conversion

RT2DB Excitation and voltage regulation system for synchronous generators

Getting Smart Evolution to the Smart Grid April 2008

Medium Voltage Drives. ABB Value Provider Program Partnership for growth and profit

The Enhanced Platform

The behavior of the cycloconverter fed gearless drive under abnormal electrical conditions

POWER TRANSMISSION OF LOW FREQUENCY WIND FIRMS

Pedals for commercial and special-purpose vehicles. Robust Electronically controlled Flexible installation.

Siemens AG SIMOTICS T-1FW3 Torque Motors. The Powerful Torque Motors. Edition February Brochure. siemens.

APPENDIX I: Description and Functional Specifications for Transmission Facilities Eligible for Competitive Solicitation

Unit 32 Three-Phase Alternators

Kontakt. Turnkey solutions for hydropower plants An overview of the ABB portfolio

Surge arresters for railway applications. Product guide. Siemens HP-AR 41. siemens.com/arresters

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Extended requirements on turbogenerators

Transmission Problem Areas. Bulk power transfer over long distances Transmission Limitations/Bottlenecks have one or more of the following:

Enabling the power of wind. Competence and expertise for wind power customers

Power Voltage Transformers for Air Insulated Substations

Request for Payment Instructions Rule 21 Export Submittal Instructions

SIMOTICS S-1FT7 Servomotors. The Compact Servomotors for High-Performance Motion Control Applications. Motors. Edition April 2017.

Surge Arresters. Supply Program. Answers for energy.

Wind is our Element. siemens.com/loher-windgenerators. Answers for industry.

Asynchronous generators

Turbogenerators. With Top Performance for Steam and Gas Applications. Specifically tailored 4-pole Synchronous Turbogenerators

GRAND RENEWABLE ENERGY PARK PROJECT DESCRIPTION REPORT. Attachment C. Turbine Specifications

Electrical Machines and Energy Systems: Overview SYED A RIZVI

Enabling resilient and cost effective access to power

Electrical Theory. Generator Theory. PJM State & Member Training Dept. PJM /22/2018

CHAPTER 3 TRANSIENT STABILITY ENHANCEMENT IN A REAL TIME SYSTEM USING STATCOM

Innovative electric road freight transport. siemens.com/mobility

Power and Distribution Transformers

Advanced Active And Reactive Power Control For Mini Grids

The future role of storage in a smart and flexible energy system

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

Transcription:

The stable way Synchronous condenser solutions siemens.com/energy/facts

Bringing grids in line with new requirements bitte PSD-Datei von der Retusche liefern, da hier Tonwertabrisse 2

Global climate change poses new challenges for power generation and transmission. Innovative solutions will contribute to the reduction in CO 2 emissions and an optimized use of energy resources. The most crucial points in today s and tomorrow s power supply are sustainability, security, and efficiency. Synchronous condenser solutions are being introduced worldwide to support today s transmission system requirements. The addition of renewables-based power generation to the energy mix, phaseout of conventional power plants, new HVDC systems, and the extension of power supply systems to remote areas influence the stability of transmission networks. Siemens offers tailor-made turnkey synchronous condensers to address the customers needs based on proven, reliable in-house equipment, extensive knowhow on transmission system requirements, and project execution experience. Benefits Short-circuit power capability Reactive power compensation Short-term overload capability Inertia to the transmission system Leveling out of»grid signals«support of grid to island operation capabilities Applications Synchronous condensers support and improve power transmission quality in a wide range of applications: Stabilization of grids High-voltage DC transmission links based on line-commutated converter technology Transmission grids with a high amount of power infeed from renewable sources Retirement/shutdown of conventional power plants 3

Technology and system overview 9 5 8 4 1 3 7 2 6 10 Siemens synchronous condenser solutions comprise a horizontal synchronous generator connected to the high-voltage transmission network via a step-up transformer. Siemens supplies a broad range of generators up to 2,235 MVA. The generators are air-, hydrogen-, and water-cooled. The synchronous generator is started up and stopped by a frequency-controlled electric motor (pony motor) or a starting frequency converter. When the generator has reached an operating speed that is synchronous to the system frequency, it is synchronized with the transmission network and acts as a motor providing reactive and short-circuit power to the transmission network. Synchronous electrical machines like synchronous generators can generally be used as synchronous condensers. Without active power delivery or con sumption, the machines can act in the same way as a capacitor or a reactor, depending on the excitation field current. 1 Synchronous generator 2 Generator step-up transformer 3 Static/brushless excitation 4 Pony motor/starting frequency converter 5 Isolated phase bus duct 6 Control and protection system 7 Auxiliary transformer 8 Generator circuit breaker 9 Optional external coolers 10 Complete civil and construction works Siemens in-house equipment 4

zu viel Text für O2e Proven, reliable in-house products Manufacturing of an air-cooled generator Generators A generator is an electric machine that converts mechani - cal energy into electric power. It operates on the basis of the dynamoelectric principle that Werner von Siemens registered for a patent with the first dynamo generator in 1867. The principle states that an electric generator does not need to have an electric current supplied from the outside to start generating electric power. A selfreinforcing electrical induction can take place due to the residual magnetism of iron. Today, the mechanical excitation, the generator s need to generate electricity, is often provided by a turbine. It drives a shaft that is known as the rotor. This shaft rotates in the stator core, in other words, inside the generator. The rotor is equipped with an electromagnet, and the moving magnetic field of the rotor causes a charge transfer in the conductor coils of the stator. The charge transfer generates electric voltage between the ends of the conductors. This is how the mechanical energy, which acts on the rotor, produces electric energy power in the stator. Excitation systems The generator is equipped with either a brushless exciter or a conventional static exciter with brushes. The two solutions have different characteristics in terms of dynamic behavior, and are selected according to the project requirements. Contrary to power electronics-based static VAr compensators (SVCs), a synchronous condenser features the major advantages of injecting large amounts of shortcircuit power and providing inertia due to its rotating mass. The same generators are implemented for synchronous condenser applications. Starting frequency converter/pony motor The startup and breaking system of a Siemens synchronous condenser is either based on a frequency-controlled pony motor or a starting frequency converter. These two methods have different advantages and will be offered from Siemens own portfolio depending on the customer s requirements. Control and protection system Generator performance is dynamically controlled by an automatic voltage regulator (AVR), which is an integral part of all excitation systems. In a brushless excitation system, the AVR is separately installed, and in case of static excitation system, AVR software is integrated in the control system of the static excitation system. In addition to the AVR system, a generator control panel is required for start and stop sequences, protection of the generator (vibration and temperature) and for cooling system control. Segment cooling Nuc Fossil Industrial H 2 O H 2 Air 50 Hz 550 1300 MVA 60 Hz 800 1065 MVA 50 Hz 350 570 MVA 60 Hz 310 540 MVA 50 Hz 165 370 MVA 60 Hz 165 310 MVA 50/60 Hz 25 300 MVA 25 65 MVA (4-pole) 1000 2235 MVA (4-pole) The Siemens generator portfolio 5

Project references Black Sea 3x60 MVAr Republic of Georgia Siemens installed three 60 MVAr synchronous condensers at the Georgia Black Sea HVDC station in June 2012. This synchronous condenser solution supports the transmission network between Georgia and Turkey with the required short-circuit power in order to operate the newly installed HVDC back-to-back station. Bjæverskov 1x250 MVAr Denmark In Denmark, Siemens delivered a 250 MVAr synchronous condenser solution that started operation in 2013, providing the transmission system with a short-circuit power of more than 800 MVA in addition to reactive power control. The installation of this stand-alone synchronous condenser solution will enable the transmission system operator Energinet.dk to operate the transmission network without the need for a large thermal power plant. This makes the installation an economically and environmentally advantageous investment enabling the infeed of large amounts of renewable energy into the transmission network. 6

These solutions will ensure the transmission system stability in the country s regions of Funen and Zealand. Siemens scope of supply comprises engineering, procurement, and construction of these facilities. The customer Energinet.dk will manage the civil work. Each synchronous condenser solution is capable of delivering more than 900 MVA of short-circuit power and +150/-75 MVAr of reactive power. The projects are running in trial operation as of August 2014. Fraugde and Herslev 2x200 MVAr Denmark Feda 1x200 MVAr Norway This solution will secure short circuit power for the NorNed HVDC connection, especially during the planned upgrade of the overhead line in the southern region of Norway. Siemens scope of supply comprises engineering, procurement, and construction of these facilities including necessary civil works. The synchronous condenser solution for Feda is capable of delivering more than 750 MVA of short-circuit power and +170/-90 MVAr of reactive power. The project is scheduled for trial operation at the end of 2014. The turnkey supply of two 225 MVA synchronous condenser systems for Talega substation in California will support the California grid with reactive power, short-circuit power, and inertia. Siemens scope of supply comprises the complete engineering, procurement, and construction of these facilities including necessary civil works. Each synchronous condenser solution for Talega is capable of delivering +225/-120 MVAr of reactive power. The units are planned to commence commercial operation in July 2015. Talega 2x225 MVAr USA 7

Published by Siemens AG 2016 Energy Management Division Freyeslebenstrasse 1 91058 Erlangen, Germany For more information, please contact our Customer Support Center. Phone: +49 180 524 70 00 Fax: +49 180 524 24 71 (Charges depending on provider) E-mail: support.energy@siemens.com Article No. EMTS-B10016-00-7600 Printed in Germany Dispo 30003 TH 263-161039 BR 1016X.X Subject to changes and errors. The information given in this document only contains general descriptions and/or performance features which may not always specifically reflect those described, or which may undergo modification in the course of further development of the products. The requested performance features are binding only when they are expressly agreed upon in the concluded contract.