Busway Power Distribution XJ-L Plug-In Units

Similar documents
Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

Busway Construction. Bus Bars

Molded Case Circuit Breakers

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

22.000A IR. Catalog Number. Price $

Molded Case Circuit Breakers

Molded Case Circuit Breakers

Introduction. Upon completion of Busway you should be able to:

Enclosed Circuit Breakers

Lighting Panelboards. P2 Panelboards

Type MP-T Type MP-HT Type MP-MT

Molded Case Circuit Breakers

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Service Entrance Methods

Boxes C " wide, 5 3 4" deep. C " wide, 5 3 4" deep. Branch Breaker Side Gutters. Type Breaker (inches) C1 BL, BLH, HBL C2 BQD 3.

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Enclosed Circuit Breakers Enclosures Type 1

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

File E47705 Vol. 7 Sec. 9 Page 1 Issued: and Report Revised:

type P1 Lighting and Power Distribution Panelboards Overview P1 Panelboards

Molded Case Circuit Breakers

Multi-Pak Group Control

PANELBOARDS SECTION 1

Specialty Service Entrance Switchboards. Selection and Application Guide

Enclosed Circuit Breakers

SERVICE ATTACHMENT ON A BUILDING WITH BUS DUCT SERVICE ENTRANCE AND INDOOR METERING

Molded Case Circuit Breakers

Panelboards Circuit Breaker / Lighting and Distribution

SECTION PANELBOARDS

XP Series Pre-Wired Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof System

Ampere Connectors Suitable for Copper or Aluminum 800 (3) - #3/0 AWG-500 Kcmil 1000 (4) - #3/0 AWG-500 Kcmil 1200 (4) - #3/0 AWB-500 Kcmil

Enclosed Circuit Breakers

Introduction. P1 Panelboards. P1 Feature Overview. Contents. Siemens Panelboards Introduction to P1 Panelboards 1. General Specifications 3

Data Bulletin. Ground-Censor Ground-Fault Protection System Type GC Class 931

Section 8. Switchboards. Contents. Sentron SMP, FCI, FCII Switchboards Type SMP. Selection Construction Details Specification Type FCI, FCII

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

A. Submit manufacturer's literature and technical data before starting work.

Molded Case Circuit Breakers

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

Molded Case Circuit Breakers

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Application guide. Tmax Link OEM UL 891 Switchboard Program

Meter Centers & Loadcenters Group Metering

Installation Instructions

File E47705 Project 97ME August 21, 1997 REPORT. MOTOR CONTROLLERS, MANUAL Amberg, FED REP Germany

Molded Case Circuit Breakers Reference Guide

BUSWAY Low Voltage (Pow-R-Flex)

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

SECTION MOTOR CONTROL

Horsepower Ratings 240V AC 1 Phase, 2 Phase, 3 Phase, Ampere Catalog List Ship Wt.* Catalog List Ship Wt.* Indoor Type 1 Outdoor Type 3R

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

ASCO Low Voltage Automatic Transfer Switch Systems

POWERBUS 225 Busway and Plug-In Units

C E R T I F I C A T E O F C O M P L I A N C E

IN2 Enclosed Switches and Circuit Breakers

Enclosed Circuit Breakers

Table Line and Load Terminals. Terminal Body Material. Wire Type. Aluminum Copper Aluminum. English English English.

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

Product Specification Sheet #3LD2.1

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

Table Types LD, HLD and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Panelboards. Type P3 Panelboards. General. Revised 04/15/14. Features

Molded Case Circuit Breakers

Amperes. F-Frame. Price U.S. $ Catalog Number. Price U.S. $ EDH2100 EDH2125 EDH2150 EDH2175 EDH2200 EDH2225

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

PANELBOARDS C1/C2 SECTION 6

Air Conditioning Disconnects Molded Case Switch

5.2. Power Pedestals. Contents Description

FACT SHEET Standard: Electrical Safety

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Lighting and Power Distribution Panelboards

COMPACT BUSWAY 40 & 60 AMP HOUSING

Quik-Spec Electrical Gear

EOEM panelboard and switchboard (OPS) Program

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 03/05/09 TSEWG TP-11: UFC N BEST PRACTICES

Low-Peak 600V Class RK1

Series C, F-frame molded case circuit breaker, 15A, Two-pole, Thermal Magnetic Trip, FD Breaker

PowerWave Bus System. For More Information Use your QR Reader THE NEXT GENERATION OF FLEXIBLE POWER DISTRIBUTION

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Power Quality and Protective Device Coordination: Problems & Solutions Part 1 Undersizing of Utility Main Service Transformers

General Specifications for Lighthouse Power Pedestal

Overload Relay Heater Tables

Cutler-Hammer. January 2001

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

1 Installation of accessories in molded case switches requires dummy trip; see page. Breaker/Switch Type TQD/TJD

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

QMB Panel boards Switchboards. 200,000A. short circuit rating. www. ElectricalPartManuals. com

Self-protected Combination Starters System PKZ 2-SP

Series C, F-frame molded case circuit breaker, 125A, Three-pole, Thermal magnetic trip. Thermal magnetic

General Purpose US Fuses

UNDERGROUND SERVICES - SECONDARY

Dry Type Distribution Transformers

5.11. Metering Products 3 MTB 400 R C. Group Metering. Catalog Number Selection

Transcription:

14 Busway Power Distribution XJ-L Plug-In Units Circuit Breaker Enclosure XQ45 XQ Circuit Breaker Enclosures Front Operable Enclosures Only Breaker Breaker AC Ampere Catalog List Catalog List Type Volts Rating Number Price $ Number Price $ XQ35 184.00 XQ45 198.00 QP and BQ 120/240 XQ35R 264.00 XQ45R 288.00 Circuit Breaker Bus Plugs Front Operable Breaker Enclosure Only Enclosure Only Breaker AC Ampere Catalog List Catalog List Type Volts Rating Number Price $ Number Price $ ED2 240 ED4 480 ED6 600 Operable Through Cover Enclosure Only Enclosure Only Breaker Breaker AC Ampere Catalog List Catalog List Catalog List Catalog List Type Volts Rating Number Price $ Number Price $ Number Price $ Number Price $ ED2 240 ED4 480 Circuit Breaker Plugs Floor Operable XEC3100 408.00 XEC3100IG 461.00 XEC4100 517.00 XEC4100IG 570.00 XLEC3100 649.00 XLEC4100 794.00 Circuit Breaker Bus Plug (Receptacles and covers supplied by installer) XQ45R Fusible Vacu-Break Switch Plugs Floor Operable 3-Pole 4-Pole Ampere Volts Rating Catalog Number List Price $ Catalog Number List Price $ 30 XLVB321 706.00 XLVB421N 880.00 240 60 XLVB322 775.00 XLVB422N 902.00 100 XLVB323 1181.00 XLVB423N 1320.00 30 XLVB351 775.00 XLVB451N 915.00 600 60 XLVB352 845.00 XLVB452N 949.00 100 XLVB353 1203.00 XLVB453N 1355.00 Circuit Breaker Bus Plug Front-operable XEC4100 For inches / millimeters conversion, see Application Data Section. XEQH floor-operating handle with ON-OFF labels, $44.50 each. Designed for 2 or 3-pole breakers only. Standard package 10 per carton. Ground kit for bonded ground Catalog Number W62890. List price $56.00. Ground kit for isolated ground Catalog Number W68101. List price $59.00. XQ plug designed for 1, 2 or 3-pole breakers use. Enclosures available from stock. For factory installed breakers, add enclosure and breaker prices together and add 20% to the total. When ordering circuit breaker bus plugs complete with breaker, factory-installed, allow time for assembly and SPECIFY enclosure frame size, phase and ampere rating. Example: One XEC3100ED23P70Afactoryassembled. On-Off bus plug, pressure-sensitive labels, W47185: $6.20 per pair. Ground kit bonded ground Catalog Number W62891. List price $56.00. W63810 required when used on XL busway list price $16.20. Breaker cover for XQ Bus Plugs, XQBRKCVR: List Price $57.00. 14-56 Discount Schedule BPLU

Busway Power Distribution XL-X, XL-U, BD Plug-In Units Circuit Breaker Plugs Floor Operable Enclosure Only Enclosure Only Catalog Catalog Catalog Number Catalog Catalog Catalog Number Breaker AC Ampere Number Number List BD List Number Number List BD List Type Volts Rating XL-X XL-U Price $ Plug-In Price $ XL-X XL-U Price $ Plug-In Price $ ED2 240 ED4 480 ED6 15 60 70 100 15 60 REC3100G UEC3100G 833.00 BEC3100 671.00 REC4100G UEC4100G 995.00 BEC4100 822.00 70 100 15 60 70 100 FD6, FXD 600 70 250 RFC3250G UFC3250G 1748.00 BFC3250 1562.00 RFC4250G UFC4250G 2025.00 BFC4250 1828.00 JXD6 200 400 JXD2 240 200 400 RJC3400G UJC3400G 4270.00 BJC3400 4039.00 RJC4400G UJC4400G 4758.00 BJC4400 4886.00 JD6 200 400 LXD6 450 600 RLC3600G ULC3600G 4514.00 BLC3600 4191.00 RLC4600G ULC4600G 5058.00 BLC4600 4990.00 LD6 MD6 600 250 600 400 600 RMC3800G UMC3800G 5266.00 BMC3800 5012.00 RMC4800G UMC4800G 5994.00 BMC4800 5792.00 700 800 I-T-E Fusible Vacu-Break Switch Plugs Floor-Operable with Line Terminal Protection Horsepower Catalog Horsepower Catalog Ratings Catalog Catalog Number Number Ratings, AC Catalog Number Number Ampere Standard Maximum List BD List Standard Maximum List BD List Volts Rating (NEC) (Time Delay) XL-X XL-U Price $ Plug-In Price $ (NEC) (Time Delay) XL-X XL-U Price $ Plug-In Price $ 030 003 007 1 2 RV321G UV321G 873.00 BOS14321 763.00 003 007 1 2 RV421G UV421G 1017.00 BOS16421 937.00 060 007 1 2 015 RV322G UV322G 950.00 BOS14322 822.00 007 1 2 015 RV422G UV422G 1040.00 BOS16422 961.00 100 015 030 RV323G UV323G 1376.00 BOS14323 1251.00 015 030 RV423G UV423G 1510.00 BOS16423 1389.00 250 AC or 200 025 060 RV324G UV324G 2225.00 BOS14324 2118.00 025 060 RV424G UV424G 2539.00 BOS16424 2431.00 250 DC 400 050 125 RV325G UV325G 5569.00 BOS14325 5486.00 050 125 RV425G UV425G 6240.00 BOS16425 6437.00 600 075 200 RV326G UV326G 8051.00 BOS14326 7604.00 075 200 RV426G UV426G 8230.00 BOS16426 8463.00 030 007 1 2 020 RV361G UV361G 950.00 BOS14351 822.00 005 015 RV461G UV461G 1063.00 BOS16451 971.00 060 015 050 RV362G UV362G 1017.00 BOS14352 891.00 015 030 RV462G UV462G 1096.00 BOS16452 1007.00 100 030 075 RV363G UV363G 1398.00 BOS14353 1274.00 025 060 RV463G UV463G 1554.00 BOS16453 1424.00 600 AC 200 060 150 RV364G UV364G 2359.00 BOS14354 2246.00 050 125 RV464G UV464G 2605.00 BOS16454 2500.00 400 125 350 RV365G UV365G 5938.00 BOS14355 5856.00 100 150 RV465G UV465G 6397.00 BOS16455 6599.00 400 125 350 RV365SG UV365SG 5938.00 100 150 RV465SG UV465SG 6397.00 600 200 500 RV366G UV366G 7996.00 BOS14356 7662.00 150 400 RV466G UV466G 8287.00 BOS16456 8521.00 14 Fuse Adapter Kits RV and UV 240V AC/250V DC Class J Class T Class R Amper- Catalog List Catalog List Catalog List age Number Price $ Number Price $ Number Price $ 30 W56626 72.00 60 W56628 91.00 100 TFAK32 76.00 W55365 61.00 200 TFAK42 102.00 W55366 61.00 400 TFAK52 102.00 W55367 91.00 600 W49813 459.00 TFAK62 120.00 W55368 91.00 600V 30 W56627 101.00 60 W56629 85.00 100 TFAK35 120.00 W55365 61.00 200 TFAK45 143.00 W55366 61.00 400 TFAK55 151.00 W55367 91.00 600 W49813 459.00 TFAK65 174.00 W55368 91.00 Field Addable Ground Kits for BD Bus Plugs Fusible Ampere Catalog List Rating Number Price $ 30 60 W63231 109.00 100 W63232 154.00 200 W63233 154.00 400 W63234 173.00 600 W63234 173.00 Circuit Breaker BEC W63553 173.00 BFC W63554 173.00 BJC W63238 263.00 BLC W63238 263.00 BMC W73534 168.00 Note: These are for use on busway with internal ground bus manufactured after March, 1986. For ground kits prior to this date, consult local sales office. Fuse Adapter Kits BOS 240V AC/250V DC Class J Class T Class R Amper- Catalog List Catalog List Catalog List age Number Price $ Number Price $ Number Price $ 30 W56626 72.00 60 W56628 91.00 100 W49827 131.00 TFAK32 76.00 W55365 61.00 200 W49819 131.00 TFAK42 102.00 W55366 61.00 400 W49814 330.00 TFAK52 102.00 W55367 91.00 600 W49813 459.00 TFAK62 120.00 W55368 91.00 600V 30 W49832 163.00 W56627 101.00 60 W49830 163.00 W56629 85.00 100 W49828 131.00 TFAK35 120.00 W55365 61.00 200 W49818 163.00 TFAK45 143.00 W55366 61.00 400 W49816 395.00 TFAK55 151.00 W55367 91.00 600 W49815 330.00 TFAK65 174.00 W55368 91.00 Grounding Finger See table. Enclosures available from stock. For factory installed breakers, add enclosure and breaker prices together and add 20% to the total. When ordering circuit breaker bus plugs complete with breaker, factory-installed, allow time for assembly and SPECIFY enclosure frame size, phase and ampere rating. Example: One UEC3100ED43P70A factory assembled Bus plugs 400A and smaller require one plug-in opening. 600 800A require two plug-in openings. To order 400A fusible plug with increased wire space, add S to the catalog number. Example: UV365SG, UV465SG. Channel Spacers Must be used with bus plugs mounted on 600, 800, or 1000 ampere ABD busway or on 800 or 1000 ampere BDP busway. Catalog Number W37940 list price $8.90 When BD busway capacity exceeds 400A for aluminum or 600A for copper, capacity must be specified to obtain proper number and arrangement of neutral fingers. Not required. Discount Schedule BPLU 14-57

14 Busway Power Distribution XL-X, XL-U and BD Plug-In Units Shipping Weights Pounds For Circuit Breaker Bus Plugs Only Enclosure Complete Enclosure Complete Only Assembly Only Assembly Breaker Ampere XL-U BD, XL-U BD, XL-U BD, XL-U BD, Type Rating XL-X LO-X XL-X LO-X XL-X LO-X XL-X LO-X ED2, ED4, 15 100 12 14 13 9 13 15 14 10 ED6 FD6 70 250 1 27 51 37 45 28 55 38 JXD6 200 400 90 35 102 57 95 36 107 58 JXD2 200 400 90 35 102 57 95 36 107 58 JD6 200 400 95 39 117 61 100 40 122 62 LXD6 450 600 140 39 175 691 147 40 182 62 LD6 450 600 140 39 175 61 147 40 182 62 MD6 400 800 140 79 175 114 147 80 182 115 Shipping Weights Pounds For Fusible Switch Bus Plugs Only XL-X XL-X XL-U BD, LO-X XL-U BD, LO-X Switch Prefix Prefix Ampere RV Prefix RV Prefix Rating UV BOS UV BOS 30,60 17 15 19 12 100 17 18 19 18 200 36 34 38 36 400 165 111 160 112 600 165 111 170 112 Special Bus Plugs Catalog Number Description XL-U XL-X BD, LO-X List Price $ Ground Detector and Potentializer For 2 or 3-pole 240 and 480 Volt service. UPGR314G RPGR314G PGR6314 1137.00 Accessories Catalog List Description Number Price $ Channel Spacers Must be used with Bus Plugs or Plug-in Branch-Run Adapters mounted on 600-, 800- or 1000-ampere ABD Busway or on 800- or 1000-ampere BDP Busway. 4 per package W37940 8.90 ON-OFF Bus Plug Stickers Pressure sensitive, per pair. W47185 6.20 BD Bus Plug Catalog Number Reference ABD4 Busway Catalog Number BDP4 Busway 225 400 600 800 1000 1200 225 400 600 800 1000 1350 ABD402 ABD404 ABD406 ABD408 ABD410 ABD412 BDP402 BDP404 BDP406 BDP408 BDP410 BDP413 BJC44001 BJC44002 BJC4400G1 BJC4400G2 BFC46001 BFC46002 BFC4600G1 BFC4600G2 BMC48001 BMC48002 BMC4800G1 BMC4800G2 BOS164251 BOS164252 BOS16425G1 BOS16425G2 BOS164261 BOS164262 BOS16426G1 BOS16426G2 BOS164551 BOS164552 BOS16455G1 BOS16455G2 BOS164561 BOS164562 BOS16456G1 BOS16456G2 1600 BDP416 14-58 Discount Schedule BPLU

Busway Power Distribution XL-X, XL-U, BD Cubicles Cubicles Molded Case Circuit Breakers (For Use With All Types of Busway) List Price $ With Breaker Breaker Ampere 3-Phase 120/280V AC Type Rating 600V AC 277/480V AC ET Heavy Duty JD6 200 400 13433. 14093. MD6 400 600 22939. 24092. 700 800 23496. 24675. 800 26867. 28135. 1000 29097. 30543. PD6 1200 34129. 35840. 1400 37488. 39364. 1600 38045. 39947. RD6 Current-Limiting CJD6 1800 43634. 45826. 2000 44763. 46993. 150 225 19947. 20948. 250 400 22939. 24079. CLD6 450 600 38895. 40833. CMD6 400 800 39895. 41885. 800 40884. 42937. 1000 44877. 47120. CPD6 1200 51860. 54457. 1400 53051. 55712. 1600 53849. 56548. CRD6 Note: Additional molded case circuit breakers not listed may be used. Consult local sales office for availability. 1800 56447. 59273. 2000 56840. 59692. 14 Fusible Switch Vacu-Break 250 600 120/208 277/480 Volts AC Volts AC Volts AC Volts AC Ampere Catalog List Catalog List Catalog List Catalog List Rating Number Price $ Number Price $ Number Price $ Number Price $ 200 FC3022 8351.00 FC3025 9010.00 FC4022 9809.00 FC4025 10594.00 400 FC3042 9593.00 FC3045 10367.00 FC4042 11280.00 FC4045 12179.00 600 FC3062 11266.00 FC3065 12166.00 FC4062 13243.00 FC4065 14295.00 800 FC3085 19200.00 FC4085 22558.00 1200 FC3125 23370.00 FC4125 27464.00 Power Circuit Breaker AC Interrupting Capacity List Price $ Breaker Maximum Symmetrical (RMS) Amperes With Breaker Frame Ampere 3-Phase, 3-Phase, Size Rating 240 Volt 480 Volt 600 Volt 3-Wire 4-Wire Type RL RL-800 800 30,000 30,000 30,000 39541. 43495. RL-1600 1600 50,000 50,000 50,000 69210. 76130. RL-2000 2000 65,000 65,000 65,000 75534. 83086. RL-3200 3200 65,000 65,000 65,000 158190. 174007. RL-4000 4000 85,000 85,000 85,000 237286. 261011. Type RLF (Fused) RL-800 800 200,000 200,000 200,000 57347. 63075. RL-3200 3200 200,000 200,000 200,000 197731. 217502. RL-4000 4000 200,000 200,000 200,000 276827. 304506. Bolted Pressure Switches Ampere 480 Volts AC 600 Volts AC Rating 3-Pole 4-Pole 3-Pole 4-Pole 800 28613. 29185. 30330. 30901. 1200 32905. 33562. 34878. 35538. 1600 35765. 36481. 37912. 38627. 2000 42919. 43777. 45493. 46352. 2500 51504. 52532. 54593. 55624. 3000 65809. 67126. 69758. 71073. 4000 94422. 96311. 100087. 101975. No fuses supplied with fusible cubicles. Cubicle pricing includes labor and material for: 1. Single cubicle frame section complete with required busway openings. 2. Circuit breaker or fusible switch. 3. Mounting of circuit breaker or fusible switch and line-side connections. Figure busway footage through cubicle to compensate for load-size connections. For other options, consult local sales office. For electrically operated, specify control voltage. 14-59

14 Busway Mobile Industrial Power Industrial Trol-E Duct 2 and 3-Pole 100/150 Amperes 600 Volt AC, 250 Volt DC Standard Duty TD310 Ship. Catalog List Weight Description Number Price $ (lbs.) Standard Straight Busway Sections 2-pole, 10 foot TD210 1001.00 40 3-pole, 10 foot TD310 1128.00 40 Drop-Out Sections 2-pole, 10 foot TD210R 1204.00 45 2-pole, 10 foot sectionalizing TD210RS 1432.00 45 3-pole, 10 foot TD310R 1357.00 45 3-pole, 10 foot sectionalizing TD310RS 1614.00 45 Busless Busway And Drop-Out Sections 10 foot busway TD010 800.80 36 10 foot drop-out TD010R 963.20 36 Accessories (Complete Assemblies) Hanger 2 and 3-pole TDH3 79.00 04 Intermediate Hanger TRH31 43.00 01 End Plate TRB23 53.00 00 3 4 Feed-In Adapter 2 and 3-pole TDF3 150.00 04 Insulated Ramp Ends (pair) 510.00 Replacement Parts Cover for standard hanger (contains 10 pieces) W43771 70.00 05 Hanger with cover (see TDH3) 04 Bus Connector (contains 12 pieces) W43101 132.00 00 1 2 Feed-In Connector (top) (contains 2 pieces) W43100 53.00 01 Feed-In Connector (side) (contains 4 pieces) W43099 130.00 01 For inches / millimeters conversion, see Application Data Section. Busway rating is 100A continuous and 150A intermittent. Note: All busway sections, regardless of length, include: 1 hanger, 1 hanger cover, 1 set of bus connectors. Recommended loads not to exceed 25 pounds. UL listed. (All dimensions in inches) / Dimensions General Straight Duct Sessions Less Than 10 Feet For each straight busway section less than 10 feet long: 1. Use base price of $228. list to cover special construction. 2. Take list price of standard 10-foot section of type required and prorate for footage price, figuring fractions to the next larger number of even feet, as shown below: Example: Required: 4 feet of 3-pole Trol-E-Duct, 100/150 ampere type. Base price to cover special construction.................$228. Footage price ($112.00/foot) prorated from TD310..................$448. List price for 4 feet of 3-pole extra footage.....................$676. Special Curved Duct Sections Curved busway sections should be figured on basis of $120. list per linear foot, plus $2090. set-up and engineering charge for each curved section. Any change of direction constitutes a curve and should be priced as above. Exceptions: 1. On a circle, 2 set-up charges will apply. 2. When 2 or more identical curves are required on a job, apply only one set-up charge to each group of identical curves. To find the linear footage of special curves of any number of degrees and any radius, use the formula shown below: 2R x 3.1416 x D =L 360 R = Radius in feet D = Degrees of curve L = Length of curve Example: Required: The length of a 75 curve with a radius of 5 1 2 feet. 2 x 5.5 x 3.1416 x 75 =7.199 feet 360 (charge for 8 feet). Fractions are figured to the next larger number of even feet, as price is always based on full linear feet. Flared Ends List price for each flared end on any straight or curved busway section $476. Special feed-in (required for busway sections with two flared ends)...$234. 14-60

Busway Mobile Industrial Power Industrial Trol-E Duct / Trolleys, Tool Hangers 2 and 3-Pole Non-Fusible 600V AC and 250V DC Number Minimum Ship. Trolley of Maximum Radius Catalog List Weight Type Poles Amperes (feet) Number Price $ (lbs.) Trolleys Only Standard 2 30 5 T131 399.00 4 Standard 3 30 5 T331 406.00 4 Curve 2 60 3 T134 716.00 5 Curve 3 60 3 T334 805.00 5 Heavy Duty 2 60 5 TR1311 478.00 4 Heavy Duty 3 60 5 TR3311 530.00 4 Roller 2 20 5 TR1312 364.00 4 Roller 3 20 5 TR3312 406.00 4 Transfer 2 30 2 T25 1241.00 7 Transfer 3 30 2 T35 1308.00 7 Button 2 60 5 T132 649.00 5 Button 3 60 5 T332 659.00 5 Trolleys Box Hangers Plain TPTH 223.00 5 Tool TBTH 292.00 6 Box Tool Hanger With SAF To Fuse Unit 30A 240V AC 250V DC TBTH302F 455.00 7 30A 600V AC TBTH306F 760.00 8 Box Tool Hanger With Receptacle 20A 240V AC 250V DC TBTH202R 628.00 7 Cleaning Trolleys Abrasive 3 5 ACT331 705.00 4 Brush 3 5 BCT331 705.00 4 Note: When trolleys are used with auxiliary equipment that has a lower rating, the rating of the auxiliary device will govern the rating of the trolley. For example: heavy-duty trolleys (maximum 60A) used with box tool hangers having SAFtoFUSE units are limited by the fuse size to a rating of 30A. Also, trolleys used with box tool hangers having receptacles are limited by the receptacles rating to a rating of 20A, 480V AC or 250V DC. Heavy Duty Trolley TR331-1 Transfer Type Trolley T35 / Dimensions Standard Trolley T331 Roller Type Trolley TR331-2 Button Type Trolley T332 14 Plain Tool Hanger Box Tool Hanger For 90A heavy duty trolleys, 2 or 3-pole, add $102. to list price above. Plain and box tool hangers are not designed for use with curve or transfer type trolleys. They are for assembly only on standard, heavy-duty, roller or button trolleys. 14-61

Busway Mobile Industrial Power Industrial Trol-E Duct 4-Pole 100/150 Amperes 480 Volt AC, 250 Volt DC / Dimensions 14 Standard Duty TD410 Ship. Catalog List Weight Description Number Price $ (lbs.) Standard Straight Busway Sections 4-pole, 10 foot TD410 44 Drop-Out Sections 4-pole, 10 foot TD410R 49 4-pole, 10 foot sectionalized TD410RS 49 Busway Accessories (Complete Assemblies) Hanger 4-pole TDH4 4 1 4 Intermediate Hanger TRH31 1 End Plate TRB23 3 4 Feed-In Adapter 4-pole TDF4 4 1 4 4-Pole Trolley Insulated Ramp Ends (pair) 30A 4-pole Button Trolley T431 4 Replacement Parts Cover for standard hanger (contains 10 pieces) W43771 5 Hanger with cover (see TDH4) 4 Bus Connector (contains 12 pieces) W43101 1 2 Feed-In Connector (top) (contains 2 pieces) W43100 1 Feed-In Connector (side) (contains 4 pieces) W43099 1 AVAILABILITY TO BE ANNOUNCED (All dimensions in inches) For inches / millimeters conversion, see Application Data Section. Busway rating is 100A continuous and 150A intermittent. See Electronic Pricing. Note: All busway sections, regardless of length, include: 1 hanger, 1 hanger cover, 1 set of bus connectors. Recommended loads not to exceed 25 pounds. UL listed. 14-62