PMA INTAKE FILTER SCREEN INSTALLATION GUIDE

Similar documents
ANTI-SYPHON VALVE INSTALLATION GUIDE

FLEX CONNECTOR HEAT SHRINK SLEEVE INSTALLATION GUIDE

FLEX-ING TM DISPENSER HOSES INSTALLATION GUIDE

EVO TM 200 AND EVO TM 400 LCD DISPLAY INSTALLATION GUIDE

DIESEL EXHAUST FLUID PUMPING ACCESSORIES INSTALLATION GUIDE

RIGID ENTRY BOOT INSTALLATION GUIDE

ADJUSTABLE ROTARY SCRAPER TOOL SCR USER S GUIDE

COMPOSITE ACCESS COVER INSTALLATION GUIDE

SEALING DIP CAP INSTALLATION GUIDE

DIESEL EXHAUST FLUID PUMP MOTOR ASSEMBLY REPLACEMENT GUIDE

FLEX PROBE INSTALLATION AND PROGRAMMING GUIDE

DEFENDER SERIES OVERFILL PREVENTION VALVE INSTALLATION GUIDE

DEFENDER SERIES BELOW GRADE DOUBLE WALL SPILL CONTAINER INSTALLATION GUIDE

SMART CONTROLLER I INSTALLATION GUIDE

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

DC400 Dispensing Cutoff System

High Capacity Submerged Turbine Pumps

STP-MLD Installation and Owner s Manual

STP-MLD+ Installation and Owner s Manual. Manual # Revision Date Changes from previous revision

STP-DHI DISPENSER HOOK ISOLATION STP-DHI 120 Volt Hook STP-DHIB 240 Volt Hook

STP / IST Fixed & Variable Length

STP-MLD. Installation and Owner s Manual

Pro 30 Gas Caddy. Model FC-P30-UL Operator s Manual. JohnDow Industries, Inc. 151 Snyder Ave. Barberton, OH 44203

STP SUBMERGED TURBINE PUMP IST INTELLIGENT SUBMERSIBLE TURBINE. Variable Length

3 Phase Smart Controller

IMPORTANT INFORMATION

DEFENDER SERIES. 5 Gallon, Single Walled, Field Replaceable Spill Container Fiberglass Model Series INSTALLATION, OPERATION, & MAINTENANCE

Installation. Introduction

IMPORTANT SAFETY NOTICE

Pro 30 Plus Gas Caddy

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

Vapor Recovery Assist System

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Intended Users This manual is meant for Gasboy Authorized Service Contractors (ASCs) who will install this kit on Atlas units.

IMPORTANT INFORMATION

UNDERCARRIAGE KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

Intended Users This document is intended for Gasboy-certified Authorized Service Contractors (ASCs) and Customer Specified Contractors (CSCs).

Introduction. Caution. This manual provides installation instructions for installing the Atlas Discharge and Valve Conduit Retrofit Kit.

Dispenser Pan Sensors & Containment Sump Sensors

Vapor Recovery Central Vacuum System

Purpose This document provides installation instructions for the Gasboy 9820 Pump Interface Kit.

DEFENDER SERIES. 5 Gallon, Double Walled, Field Replaceable Spill Container Model Series INSTALLATION, OPERATION, & MAINTENANCE

OWNER S MANUAL SUBMERSIBLE UTILITY PUMP

Blizzard, PO Box , Milwaukee, WI B31184 UNDERCARRIAGE KIT. Ford F

Safety Precaution. Notation. Meaning of symbols WARNING CAUTION

B32207 UNDERCARRIAGE KIT. Parts List and Installation Instructions CAUTION. Read this document before installing the snowplow.

RECEIVER MOUNT KIT LP-8 Tailgate Spreaders

THE SUBMERGED PUMP SYSTEM SUPPLYING THE DISPENSERS MAY TURN ON UNEXPECTEDLY TO PERFORM A LINE LEAK TEST. THIS MAY RESULT

Effective November 2016 Supersedes September 1998 (S )

PRODIGY & PRO PLUS Skid Steer Snowplows

UPP Polyethylene Dispenser Sump

DIAGNOSTIC TOOL BATTERY

TP300 INDUSTRIAL TRASH PUMP OPERATOR S MANUAL

Advanced Pumping Solutions. Safe, efficient, reliable performance

Blizzard, PO Box , Milwaukee, WI B32214 UNDERCARRIAGE KIT. Dodge Dakota Dodge Durango

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

EZ FIT SYSTEM FLEXIBLE CONNECTORS: SERVICE STATION HARDWARE

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

Owner s Manual GLASSLINED PUMP TANK

Model 1000 Low Profile Tailgate Spreader Receiver Mount

Series K Pneumatic Switch Mechanism

75918 Heavy Duty 3-Point Mount

Battery Desktop Charger Operation Manual Northridge Dr. N.W. Suite 1 Walker, MI _REV.

Fueltec Models 950AW & 955SS Mobile Fuel Tank Cleaning Systems

Dispenser Pan Sensors & Containment Sump Sensors

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

Introduction 1 Important Safety Information 3 Installing TopKAT Series 900 Replacement Report Printer Kit 5

MOUNT KIT. Polaris Ranger Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

Western Products, PO Box , Milwaukee, WI MOUNT KIT

en Vibroplate VP 1550 (RAW) OPERATOR S MANUAL

MOUNT KIT. Kubota RTV 900, 1140 Kubota RTV X-Series. Installation Instructions CAUTION. Read this document before installing the snowplow.

Galaxy VM. Battery Breaker Box Installation 09/

Purpose Of This Document This manual provides the information to assemble and install Lighted Canopy Conduit Kits on The Advantage Series.

Mount Kit. Chevy/GMC 1500HD/2500/3500 4X Chevy/GMC Suburban 2500 Yukon XL Installation Instructions CAUTION

Galaxy Receiving and Unpacking 09/

FUEL INJECTOR / VAPOR SEPARATOR SEAL KIT, P/N INSTALLATION INSTRUCTIONS

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

OMEGA CORDLESS SERIES VACUUM INSTRUCTION MANUAL

MOUNT KIT. Installation Instructions CAUTION. Read this document before installing the snowplow. CAUTION

Purpose This document provides installation instructions for Gasboy 9800A/2600A Pump Interface Kits.

Installation Manual Stand-Alone Dispenser Pan Sensor

Required Tools and Materials Following tools and materials are required to install the Boot Switch Kit: Nut Driver Heat Gun Thread Lock

AIR MOTOR DRIVE

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

CONTACTS EGR VALVE TESTER 66248

Installation and Operation Manual A / A G30 Cold Climate Kit

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

Propane torch. Model Assembly And Operation Instructions

Martin Tornado Retrofit Valve

BlinkerBeam Solar Controller

General information about underground storage tank (UST) fueling systems in every day language.

HD2 and HDX Skid Steer Snowplows

Air Operated Diaphragm Pumps Operating and Maintenance Instructions

Utility Mount. Tailgate Spreaders. Installation Instructions CAUTION. Read this document before installing or operating the spreader.

SUPER PUMP OUT SYSTEM

Transcription:

PMA INTAKE FILTER SCREEN INSTALLATION GUIDE

The information in this publication is provided for reference only. While every effort has been made to ensure the reliability and accuracy of the information contained in this manual at the time of printing, we recommend that you refer to franklinfueling.com for the most current version of this manual. All product specifications, as well as the information contained in this publication, are subject to change without notice. Franklin Fueling Systems does not assume responsibility and expressly disclaims liability for loss, damage, or expense arising out of, or in any way connected with, installation, operation, use, or maintenance by using this manual. Franklin Fueling Systems assumes no responsibility for any infringement of patents or other rights of third parties that may result from use of this manual or the products. We make no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Copyright 2017 Franklin Fueling Systems, Madison, WI 53718. All world rights reserved. No part of this publication may be stored in a retrieval system, transmitted, or reproduced in any way, including, but not limited to, photocopy, photograph, magnetic, or other record, without the prior written permission of Franklin Fueling Systems. For technical assistance, please contact: Franklin Fueling Systems 3760 Marsh Rd. Madison, WI 53718 USA Web: franklinfueling.com Telephone: USA and Canada: +1.608.838.8786, +1.800.225.9787 USA and Canada Technical Support: +1.800.984.6266 UK: +44 (0) 1473.243300 Mexico: 001.800.738.7610 China: +86.10.8565.4566 400669001 r5

Contents Introduction...1 Conventions used in this manual...1 Questions and concerns...1 Operating precautions...2 Installation...3

Intentionally Blank

Introduction Conventions used in this manual This manual includes safety precautions and other important information presented in the following format: NOTE: This provides helpful supplementary information. IMPORTANT: This provides instructions to avoid damaging hardware or a potential hazard to the environment, for example: fuel leakage from equipment that could harm the environment. CAUTION: This indicates a potentially hazardous situation that could result in minor or moderate injury if not avoided. This may also be used to alert against unsafe practices. WARNING: This indicates a potentially hazardous situation that could result in severe injury or death if not avoided. DANGER: This indicates an imminently hazardous situation that will result in death if not avoided. Questions and concerns In case of emergency, follow the procedures established by your facility. If you have questions or concerns about safety or need assistance, use the information below to contact Franklin Fueling Systems: Web: franklinfueling.com Telephone: USA and Canada: +1.608.838.8786, +1.800.225.9787 USA Technical Support: 1.800.984.6266 UK: +44 (0) 1473.243300 Mexico: 001.800.738.7610 China: +86.10.8565.4566 1

Operating precautions Franklin Fueling Systems (FFS) equipment is designed to be installed in areas where volatile liquids such as gasoline and diesel fuel are present. Working in such a hazardous environment presents a risk of severe injury or death if you do not follow standard industry practices and the instructions in this manual. Before you work with or install the equipment covered in this manual, or any related equipment, read this entire manual, particularly the following precautions: IMPORTANT: Refer to the documentation provided with the product for additional warnings and safety information. IMPORTANT: To help prevent spillage from an underground storage tank, make sure the delivery equipment is well-maintained, that there is a proper connection, and that the fill adaptor is tight. Delivery personnel should inspect delivery elbows and hoses for damage and missing parts. CAUTION: Use only original FFS parts. Substituting non-ffs parts could cause the device to fail, which could create a hazardous condition and/or harm the environment. WARNING: This product is part of a pressurized system. Relieve the pressure in the system before working on parts in the dispensing system. WARNING: Follow all codes that govern how you install and service this product and the entire system. Always disconnect power to the Submersible Turbine Pump (STP) and related equipment at the electrical supply box. Always lock out and tag electrical circuit breakers while installing or servicing this equipment and related equipment. A potentially lethal electrical shock hazard and the possibility of an explosion or fire from a spark can result if the electrical circuit breakers are turned on while you are installing or servicing this product. Refer to this manual (and documentation for related equipment) for complete installation and safety information. WARNING: Before you enter a containment sump, check for the presence of hydrocarbon vapors. Inhaling these vapors can make you dizzy or unconscious, and if ignited, they can explode and cause serious injury or death. Containment sumps are designed to trap hazardous liquid spills and prevent environmental contamination, so they can accumulate dangerous amounts of hydrocarbon vapors. Check the atmosphere in the sump regularly while you are working in it. If vapors reach unsafe levels, exit the sump and ventilate it with fresh air before you resume working. Always have another person standing by for assistance. WARNING: Follow all federal, state, and local laws governing the installation of this product and its associated systems. When no other regulations apply, follow NFPA codes 30, 30A, and 70 from the National Fire Protection Association. Failure to follow these codes could result in severe injury, death, serious property damage, and/or environmental contamination. WARNING: Always secure the work area from moving vehicles. The equipment in this manual is usually mounted underground, so reduced visibility puts service personnel working on it in danger from moving vehicles that enter the work area. To help prevent this safety hazard, secure the area by using a service truck (or some other vehicle) to block access to the work area. WARNING: Discharge static electricity from the splice kit to ground before you install it, and make sure it is properly grounded while in service. WARNING: Make sure you check the installation location for potential ignition sources such as radio waves, ionizing radiation, and ultrasound sonic waves. If you identify any potential ignition sources, you must make sure safety measure are implemented. 2

Installation PMA End Bell Filter Clip Filter Screen Mounting Screw 1. Remove 2 opposite sections of the rib guards on the end bell to make room to mount the filter clip. 2. Remove the plastic hole plug from the bottom of the Pump Motor Assembly (PMA) end bell. IMPORTANT: Make sure no broken rib pieces enter the PMA. 3. Insert the filter clip into the end bell by pushing one end through the center hole and the other through the opening in the side of the end bell. 4. Align the filter clip nut with the PMA shaft. 5. Place the filter screen over the end bell, and insert the screw into the filter screen to engage the filter clip nut. 6. Tighten until the filter screen is snug. Do not over-tighten. 3

A Franklin Fueling Systems Brand 400669001 r5