STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

Similar documents
STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

STANDBY 240 ekw 300 kva 50 Hz 1500 rpm 400 Volts

PRIME 365 ekw 456 kva 60 Hz 1800 rpm 480 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1360 ekw 1700 kva 50 Hz 1500 rpm 400 Volts

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

PRIME 591 ekw 739 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 3000 ekw 3750 kva 60 Hz 1800 rpm 4160 Volts

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 400 Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva

STANDBY 484 ekw 605 kva 50 Hz 1500 rpm 400 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 900 ekw 1125 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

CONTINUOUS 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Specifications. 3406C Generator Set Electric Power

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL 800 ekw 1000kVA 60 Hz 1800 rpm 480Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 50 Hz 1500 rpm Volts

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1500 ekw 1875 kva 60 Hz 1800 rpm 600 Volts

MISSION CRITICAL STANDBY. 50 Hz 1500 rpm Volts DIESEL GENERATOR SET FEATURES

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1250 ekw 1562 kva 60 Hz 1800 rpm 480 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

MISSION CRITICAL STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 700 ekw 875 kva 60 Hz 1800 rpm 600 Volts

PRIME 292 ekw 365 kva 50 Hz 1500 rpm 400 Volts

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

Mission Critical Standby 1400 ekw 1750 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

220 to Volts or 1800 RPM

220 to Volts or 1800 RPM

Engine Specifications 3512C HD ATAAC, V-12, 4-Stroke Water-Cooled Diesel Compression Ratio 14.7:1 Aspiration

CONTINUOUS 728 ekw 910 kva 50 Hz 1500 rpm 400 Volts

STANDBY. 60 Hz 1800 rpm 480 Volts DIESEL GENERATOR SET FEATURES

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 225 ekw 281 kva

DIESEL GENERATOR SET FEATURES

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

220 to Volts. Generator Set Configurations U.S. EPA Certified for Stationary Emergency Use Only (Tier 2 Nonroad Equivalent Emission Standards)

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm Volts

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

Voltage 220 to or 1800 RPM

PRIME 910 ekw 1138 kva 60 Hz 1800 rpm 480 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

Generator Set Specifications 100 ekw (125 kva)

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

1500 or 1800 RPM. Engine Specifications C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel 145 mm (5.71 in) 183 mm (7.2 in) Compression Ratio 14.

P R I M E e k W k V A 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

STANDBY 520 ekw 650 kva 50 Hz 1500 rpm 400 Volts

3412C Generator Set Electric Power. Specifications. Benefits and Features

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

220 to volts. Electronic unit injection

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

Continuous, Prime, Standby, Mission Critical

220 to volts. Engine Specifications 3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel 170 mm (6.69 in) Compression Ratio 14.

PRIME 1825 ekw 2281 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 480 Volts

ESP 550 ekw 688 kva 60 Hz 1800 rpm 480 Volts

DIESEL FEATURES GENERATOR SET

Standby 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1600 ekw 2000 kva 50 Hz 1500 rpm Volts

Specifications. C13 Generator Set Electric Power

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

Transcription:

DIESEL GENERATOR SET STANDBY 250 ekw 313 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness. Image shown may not reflect actual package. FEATURES FUEL/EMISSIONS STRATEGY Low Fuel consumption UL 2200 UL 2200 listed packages available. Certain restrictions may apply. Consult with your Cat Dealer. SINGLE-SOURCE SUPPLIER Fully prototype tested with certified torsional vibration analysis available WORLDWIDE PRODUCT SUPPORT Cat dealers provide extensive post sale support including maintenance and repair agreements Cat dealers have over 1,800 dealer branch stores operating in 200 countries The Cat S O S SM program cost effectively detects internal engine component condition, even the presence of unwanted fluids and combustion by-products CAT 3306B TA DIESEL ENGINE Reliable, rugged, durable design Field-proven in thousands of applications worldwide Four-stroke-cycle diesel engine combines consistent performance and excellent fuel economy with minimum weight CAT GENERATOR Designed to match the performance and output characteristics of Cat diesel engines Single point access to accessory connections UL 1446 recognized Class H insulation

FACTORY INSTALLED STANDARD & OPTIONAL EQUIPMENT System Standard Optional Air Inlet Single stage canister type air cleaner Service indicator Dual element air cleaner Heavy duty air cleaner & muffler Light-duty air cleaner Precleaner Cooling Exhaust Radiator with guard and duct flange Coolant drain line with valve Fan and belt guards Dry exhaust manifold Flanged outlet Jack water heater Caterpillar Extended Lift Coolant Low coolant level alarm or shutdown Industrial muffler Residential muffler Critical muffler Muffler mounting kit Flexible fitting Fuel Fuel priming pump Day tanks Water separator Flexible fuel lines Fuel pressure gauge Generator Self excited Class H insulation Class F Temperature (105ºC prime/130ºc standby) VR3 voltage regulator, 3-phase sensing Permanent magnet excitation Anti-condensation space heater Terminal strip connection Extension box Oversize generators Circuit breaker, UL Listed, 3 & 4-pole with shunt trip Multiple breaker capability Governor Hydra-mechanical PSG Woodward 1724 Load sharing module Governor control motor Control Panels EMCP II EMCP II+ Customer Communication Module Local alarm and remote annunciator modules Lube Lubrication oil and filter Manual sump pump Oil drain line with valve Fumes disposal Mounting Starting/Charging General Formed steel base Linear vibration isolators between base and engine-generator Energized to Run (ETR) fuel shutoff solenoid 24 volt starting motor 35 amp charging alternator Sub base fuel tanks (single and dual wall) Heavy-duty skidable base Heavy-duty skidable base w/fuel tank Narrow base Lifting arch 5 or 10 amp battery charger Energized to Shutoff (ETS) fuel shutoff solenoid Ether starting aid Battery sets Enclosures - sound attenuated, weather protective Automatic transfer switches (ATS) CSA Certification 2

SPECIFICATIONS CAT SR4B GENERATOR Frame Size...446 Excitation...Self Excited Pitch... 0.7500 Number of poles...4 Number of bearings... Single Bearing Insulation... UL 1446 Recognized Class H with tropicalization and antiabrasion IP Rating...Drip Proof IP22 Alignment... Pilot Shaft Overspeed capability - % of rated... 150 Wave form... Less than 5% deviation Paralleling kit/droop transformer... Optional Voltage regulator...3 Phase sensing with volts/hz Voltage Regulation...Less than +/- 1/2% (steady state) Less than +/- 1% (No load to full load) Telephone Influence Factor... Less than 50 Harmonic distortion... Less than 5% CAT DIESEL ENGINE 3306B TA, I-6, 4-stroke-cycle watercooled diesel Bore - mm... 120.70 mm (4.75 in) Stroke - mm... 152.40 mm (6.0 in) Displacement - L... 10.45 L (637.7 in 3 ) Compression ratio... 15.0:1 Aspiration... Air-to-air aftercooled Fuel System... Pump and Lines Governor type... Hydra-mechanical CAT CONTROL PANELS EMCP II 24 Volt DC Control NEMA 1, IP22 enclosure Electronically dead front Lockable hinged door Generator instruments meet ANSI C-39-1 Single location customer connection point Panel illuminating lights Auto start/stop control Voltage adjust potentiometer True RMS AC metering Digital indications for: - RPM - Operating hours - Oil pressure - Coolant temperature - System DC volts - AC volts, phase amps, Hz Shutdowns with indicating lights for: - Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) 3

TECHNICAL DATA Open Generator Set - - 1800 rpm/60 Hz/208 Volts DM6443 Package Performance Genset Power rating with fan Genset Power rating @ 0.8 pf 250 ekw 312.5 kva Fuel Consumption 100% load with fan 72.3 L/hr 19.1 Gal/hr 75% load with fan 53.8 L/hr 14.2 Gal/hr 50% load with fan 37.8 L/hr 10.0 Gal/hr Cooling System 1 Air flow restriction (system) 0.12 kpa 0.48 in. water Engine coolant capacity 15.9 L 4.2 gal Exhaust System Combustion air inlet flow rate 21.4 m³/min 755.7 cfm Exhaust stack gas temperature 534.5 º C 994.1 º F Exhaust gas flow rate 61.5 m³/min 2171.9 cfm Exhaust flange size (internal diameter) 152.4 mm 6.0 in Exhaust system backpressure (maximum allowable) 6.7 kpa 26.9 in. water Heat Rejection Heat rejection to coolant (total) 116 kw 6597 Btu/min Heat rejection to exhaust (total) 275 kw 15639 Btu/min Heat rejection to atmosphere from engine 55 kw 3128 Btu/min Heat rejection to atmosphere from generator 22.3 kw 1268.2 Btu/min Alternator 2 Motor starting capability @ 30% voltage dip Frame Temperature Rise 446 skva 446 130 º C 234 º F Lube System Sump refill with filter 39.0 L 10.3 gal 1 Ambient capability at 200 m (660 ft) above sea level. For ambient capability at other altitudes, consult your Caterpillar dealer. 2 Generator temperature rise is based on a 40ºC (104ºF) ambient per NEMA MG1-32. 4

RATING DEFINITIONS AND CONDITIONS Meets or Exceeds International Specifications: ABGSM TM3, AS1359, AS2789, BS4999, BS5000, BS5514, DIN6271, DIN6280, EGSA101P, IEC34/1, ISO3046/1, ISO8528, JEM1359, NEMA MG 1-22, VDE0530, 89/392/EEC, 89/336/EEC Standby - Output available with varying load for the duration of the interruption of the normal source power. Standby power in accordance with ISO8528. Fuel stop power in accordance with ISO3046/1, AS2789, DIN6271, and BS5514. Standby ambients shown indicate ambient temperature at 100 percent load which results in a coolant top tank temperature just below the shutdown temperature. Ratings are based on SAE J1995 standard conditions. These ratings also apply at ISO3046/1, DIN6271, and BS5514 standard conditions. Fuel Rates are based on fuel oil of 35º API (16º C or 60º F) gravity having an LHV of 42 780 kj/kg (18,390 Btu/lb) when used at 29º C (85º F) and weighing 838.9 g/liter (7.001 lbs/u.s. gal.). Additional Ratings may be available for specific customer requirements. Consult your Caterpillar representative for details. 5

DIMENSIONS Package Dimensions Length 3200.4 mm 126 in Width 1320.8 mm 52 in Height 1714.2 mm 67.49 in Weight 2361 kg 5,205 lb NOTE: For reference only - do not use for installation design. Please contact your local dealer for exact weight and dimensions. (General Dimension Drawing #2262915). Performance No.: DM6443 Feature Code: 306DE1B Gen. Arr. Number: 1304718 Source: U.S. Sourced July 01 2011 17789744 6 www.cat-electricpower.com 2011 Caterpillar All rights reserved. Materials and specifications are subject to change without notice. The International System of Units (SI) is used in this publication. CAT, CATERPILLAR, their respective logos, "Caterpillar Yellow," the "Power Edge" trade dress, as well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission.