INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

Similar documents
INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300. Part Number:

ENGEN -100/ENGEN -200 ENGINE GENERATOR CONTROLLER

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

INSTRUCTION MANUAL FOR

PM300E Voltage Regulator Instruction Manual

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

EA07. Generator Automatic Voltage Regulator Operation Manual

UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by

CBS 212/CBS 212A CURRENT BOOST SYSTEM

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

XR500B Universal Voltage Regulator

ESC2301. Universal Electronic Governor Controller Operation Manual

MX431 Generator Automatic Voltage Regulator Operation Manual

Instruction Manual. Installation Operation Maintenance. KCR 760 Voltage Regulator

EG3000. Generator Electronic Governor Controller Operation Manual

EA16. Generator Automatic Voltage Regulator Operation Manual

5001TCP SPEED CONTROLLER

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

ESD5500E Series Speed Control Unit

MODEL 422 Submersible Pump Controller

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

5001TCP SPEED CONTROLLER

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

BE1-50/51B with S1 Case or FT-11 sized Case and Cover For non-retrofit applications, see Product Bulletin UHD.

Specifications. Minimum Build Up Volts 3.5vac. Voltage Regulator

Power-Tronics, Inc. Electronic Voltage Regulators and Static Exciters P.O. Box , Kerrville, Texas 78029

EG3002. Electronic Engine Governor Controller User Manual

EA06. Generator Automatic Voltage Regulator Operation Manual

ENGINE GOVERNING SYSTEMS

EG1065X. Compatible with Barber Colman* Dyn1-1065X series * Use for reference purpose only and not a genuine Barber Colman product.

M T E C o r p o r a t i o n. dv/dt Filter. Series A VAC USER MANUAL PART NO. INSTR REL MTE Corporation

EG1069X. Generator Electronic Governor Controller Operation Manual

VoltPro VP4 Automatic Voltage Regulator

RP-4000 Reserve Power Control

ESD5550 / 5570 Series Speed Control Units

PRODUCT SERIES: DPG-2100

INSTALLING, OPERATING AND MAINTAINING THE MODEL D1028 COMPUTER INPUT BI-DIRECTIONAL GENERATOR FIELD REGULATOR INSTRUCTION MANUAL # S-225

ADDITIONAL INFORMATION. BE1-50/51B SELF POWERED TIME OVERCURRENT RELAY and RETROFIT KITS. FEATURES and APPLICATION Page 2

2301A Load Sharing & Speed Control with Dual Dynamics. Product Manual (Revision NEW, 1990) Original Instructions

AFM500X Automatic Flashing Module

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL MTE Corporation

SE-400 MANUAL GROUND-FAULT-RELAY TEST UNIT

A1P OPERATING MANUAL

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

SM50F48PM (-48V) Rectifier Module. Critical Power Product Manual. Part Number: SM50F48PMPD.

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

M9106-AGx-2N0x Series Electric Non-spring Return Actuators

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

ESD5100 Series Speed Control Unit PART NUMBER ESD5120 ESD (127)

PowerOhm Installation Manual for BM R Series Braking Modules

Boston Gear Ratiotrol DC Motor Speed Control

Product Manual (Revision D, 5/2015) Original Instructions. 2301A Speed Control. Installation and Operation Manual

Product Manual (Revision B) Original Instructions. EPG Electrically Powered Governor Models 501 and Installation and Operation Manual

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

SE450 Static Exciter Module

High Frequency SineWave Guardian TM

3. OPERATION 2.1. RESTRAINT CIRCUIT 2.6. INDICATING CIRCUIT 2.2. OPERATING CIRCUIT 2.7. SURGE PROTECTION CIRCUIT 2.3.

TROUBLESHOOTING GENERATOR UNITS

INSTALLATION AND SET-UP MANUAL FOR THE NEW: AVR-07. A CONTROLPAK AVR Automatic Voltage Regulator for three-phase and single-phase alternators

R & D SPECIALTIES ROTROL I USER'S MANUAL

Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear Ratiotrol

TRAC-3 TENSION READOUT AND CONTROL

G76x Direct Spark Ignition Controls

EDG6000 Electronic Digital Governor

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

MANUAL TROUBLESHOOTING. ECM Motor. ECM / ECM-DX Series. v100 Issue Date: 08/15/ Price Industries Limited. All rights reserved.

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

SE-3SCR-LM MANUAL MOTOR LOAD MANAGER

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

2.0 CONSTRUCTION 3.0 OPERATION. SA-1 Generator Differential Relay - Class 1E 2.5 TRIP CIRCUIT

DIGITAL GENSET CONTROLLER

Table of Contents. For latest version, visit:

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

KBVF Adjustable Frequency Drive

Product Manual (Revision C) Original Instructions. Air/Fuel Ratio Control. Installation and Operation Manual

MATRIX FILTER USER MANUAL. SERIES D 600 Volts, 60HZ PART NO. INSTR 026 REL REV MTE Corporation

10V. the rack of the oil pump must be on the

ESD-5550/5570 Speed Control Unit. Manual

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

Filtered PWM Speed Control for Permanent Magnet DC Motors

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

Powers TM Controls EA 338 Electronic Actuator

XR500D-277V Special Voltage Regulator

James Hamilton Electrical Pty Ltd (Inc in Qld) A.C.N trading as. Power Drive Systems. Generator Control Specialists

XR500D Universal Voltage Regulator

Damper Actuator Installation

Boston Gear Ratiotrol

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

SALDET SALES & SERVICE, INC. CLINTON TOWNSHIP, MICHIGAN

Transcription:

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR 125-5 P/N 9168800100 Publication: 9168800990 Revision: J 03/09

INTRODUCTION This instruction manual provides information about the operation and installation of the APR 125-5 voltage regulator. To accomplish this, the following information is provided: General Information and Specifications Functional Description Installation Maintenance and Troubleshooting WARNING! To avoid personal injury or equipment damage, only qualified personnel should perform the procedures in this manual. 9168800990 Rev J APR 125-5 Introduction i

First Printing: May 1985 Printed in USA 2009 Basler Electric, Highland Illinois 62249 USA All Rights Reserved March 2009 CONFIDENTIAL INFORMATION of Basler Electric, Highland Illinois, USA. It is loaned for confidential use, subject to return on request, and with the mutual understanding that it will not be used in any manner detrimental to the interest of Basler Electric. It is not the intention of this manual to cover all details and variations in equipment, nor does this manual provide data for every possible contingency regarding installation or operation. The availability and design of all features and options are subject to modification without notice. Should further information be required, contact Basler Electric. BASLER ELECTRIC ROUTE 143, BOX 269 HIGHLAND IL 62249 USA http://www.basler.com, info@basler.com PHONE +1 618.654.2341 FAX +1 618.654.2351 ii APR 125-5 Introduction 9168800990 Rev J

REVISION HISTORY Substantive changes made to this manual (9168800990) are listed below. Manual Revision and Date Change H, 07/01 Corrected Figure 3-5 to show 240 Vac connection from transformer Added UL recognition and CSA certification Updated style of manual I This revision level not used J, 03/09 Revised caption of Figure 3-2 to show external voltage adjustment potentiometer value instead of part number Updated illustrations of front panel to reflect use of new overlay Made minor text and illustration changes throughout manual 9168800990 Rev J APR 125-5 Revision History iii

This page intentionally left blank. iv APR 125-5 Revision History 9168800990 Rev J

CONTENTS SECTION 1 GENERAL INFORMATION... 1-1 DESCRIPTION... 1-1 SPECIFICATIONS... 1-1 Output Power (With 240 Vac Input)... 1-1 Exciter Field DC Resistance... 1-1 Power Input... 1-1 Sensing Input... 1-1 Voltage Adjustment... 1-1 Regulation... 1-1 Voltage Buildup... 1-1 Frequency Compensation... 1-2 Overexcitation Shutdown... 1-2 Power Dissipation... 1-2 EMI Suppression... 1-2 Vibration... 1-2 Shock... 1-2 Temperature... 1-2 Agency Recognition... 1-2 Weight... 1-2 SECTION 2 FUNCTIONAL DESCRIPTION... 2-1 OVEREXCITATION SHUTDOWN... 2-1 ACCESSORY ITEMS... 2-1 Power Isolation Transformer... 2-1 Paralleling Module... 2-1 Manual Voltage Control... 2-1 Current Boost System... 2-1 SECTION 3 INSTALLATION... 3-1 MOUNTING... 3-1 CONNECTIONS... 3-1 Connection Procedure... 3-4 SECTION 4 OPERATION... 4-1 INTRODUCTION... 4-1 PRELIMINARY SETUP... 4-1 SYSTEM STARTUP... 4-1 OVEREXCITATION SHUTDOWN... 4-2 ADJUSTMENTS... 4-2 Field Flashing... 4-2 Frequency Roll-Off Adjustment... 4-2 Stability Adjustment... 4-2 Voltage Adjustment... 4-3 OPERATIONAL TEST... 4-3 SECTION 5 MAINTENANCE... 5-1 PREVENTIVE MAINTENANCE... 5-1 TROUBLESHOOTING... 5-1 9168800990 Rev J APR 125-5 Contents v

This page intentionally left blank. vi APR 125-5 Contents 9168800990 Rev J

SECTION 1 GENERAL INFORMATION DESCRIPTION The Basler Electric APR 125-5 voltage regulator is an epoxy-potted unit housed in a metal case. The voltage regulator controls the dc exciter field power to regulate the output voltage of medium-size, 50 or 60 hertz brushless generators that have a 125 Vdc field. Regulation is provided by sensing the generator output voltage, converting it to a dc signal and comparing the signal to a reference voltage. An error signal is developed and used to control the dc field power in order to maintain a constant generator output. SPECIFICATIONS APR 125-5 electrical and physical specifications are listed in the following paragraphs. Output Power (With 240 Vac Input) Maximum Continuous: 5 Adc at 125 Vdc (625 W) Forcing (1 Minute): 8 Adc at 200 Vdc (1,600 W) Exciter Field DC Resistance Minimum: Maximum: 25 Ω 100 Ω Power Input Range: Burden: 190 to 277 Vac, 10%, single-phase, 50/60 Hz 1,000 VA, maximum Sensing Input Voltage 240 Vac Input: 190/220 Vac at 50 Hz, nominal 208/240 Vac at 60 Hz, nominal 480 Vac Input: 380/400/415 Vac at 50 Hz, nominal 416/450/480 Vac at 60 Hz, nominal Burden: 1 VA Voltage Adjustment Range: External Rheostat: 170 to 264 Vac or 340 to 528 Vac using the front-panel voltage adjustment control. A 5 kω, 2 W, locking-shaft potentiometer with a slotted shaft is supplied with the APR125-5 for remote mounting. The external rheostat provides a 10% adjustment of the nominal value determined by the front-panel voltage adjustment control. Regulation Accuracy: Voltage Drift: Response Time: 0.25% < 1% voltage variation for a 50 C (90 F) change <1.0 cycle Voltage Buildup The APR 125-5 has internal provisions for automatic voltage buildup from generator residual voltages as low as 6 Vac. 9168800990 Rev J APR 125-5 General Information 1-1

Frequency Compensation See Figure 1-1 for the APR 125-5 frequency compensation curves. Figure 1-1. APR 125-5 Frequency Compensation Curves Overexcitation Shutdown See Section 2 for details of overexcitation shutdown operation. Power Dissipation 25 W, maximum EMI Suppression Internal filter provides electromagnetic suppression. Vibration Withstands: 1.2 G at 5 to 26 Hz 0.036 (0.914 mm) double amplitude at 27 to 53 Hz 5.0 G at 54 to 1,000 Hz Shock Withstands up to 15 G in each of three mutually perpendicular axes. Temperature Operating: Storage: Agency Recognition UL Recognition: CSA Certification: Weight Net: Shipping: 40 to 70 C ( 40 to 158 F) 65 to 85 C ( 85 to 185 F) Per Standard 508, UL file No. E97035 Per Standard CAN/CSA-C22.2, No. 14-M91, CSA file No. LR23131 5.1 lb (2.3 kg) 6.1 lb (2.77 kg) 1-2 APR 125-5 General Information 9168800990 Rev J

SECTION 2 FUNCTIONAL DESCRIPTION OVEREXCITATION SHUTDOWN If the exciter field voltage exceeds 190 Vdc, the voltage regulator automatically removes the field current after a time delay. This time delay is inversely proportional to the magnitude of the detected overvoltage condition (see Figure 2-1). At approximately 280 Vdc, the field voltage is removed instantaneously. Overexcitation shutdown will not occur below 160 Vdc. Figure 2-1. Typical Inverse Time Delay Characteristic Curves Upon detection of overexcitation and the resulting field voltage shutdown, the voltage regulator will not reset or return to an operational condition until the generator output decreases to less than 6 Vac for a minimum of 10 seconds. ACCESSORY ITEMS Power Isolation Transformer A low-voltage, power isolation transformer can be used to provide electrical isolation and match voltages from the generator to the voltage regulator. To obtain maximum voltage regulator output power (exciter field resistance of 25 to 30 Ω), select a power isolation transformer of 1.0 kva or greater. For field resistances of 30 Ω or higher, the transformer may be derated (500 VA at 50 Ω, 250 VA at 100 Ω). Paralleling Module To parallel two or more generators using droop or cross-current compensation, use an APM 2000 paralleling module and a current transformer with a 5 Aac nominal secondary. Manual Voltage Control The MVC 300 manual voltage control offers backup excitation for the regulator in critical applications. The regulated output of this electronic device improves the performance of a generator using traditional types of manual control. Current Boost System The CBS 320 uses the APR 125-5 and a current transformer (to tap the generator s line current) to boost the field current during short-circuit conditions or large motor starting. 9168800990 Rev J APR 125-5 Functional Description 2-1

This page intentionally left blank. 2-2 APR 125-5 Functional Description 9168800990 Rev J

SECTION 3 INSTALLATION MOUNTING The APR 125-5 may be mounted in any position using quarter-inch hardware and may be mounted directly on the generator. Select the proper mounting hardware to withstand any expected operating and shipping/transportation conditions. Outline dimensions for the APR 125-5 and external voltage adjust control are shown in Figures 3-1 and 3-2. Dimensions are listed in inches with millimeters in parenthesis. Figure 3-1. APR 125-5 Outline Dimensions Figure 3-2. External Voltage Adjust Potentiometer, 5 kω, 2 W 9168800990 Rev J APR 125-5 Installation 3-1

CONNECTIONS APR 125-5 interconnection diagrams are provided in Figures 3-3, 3-4, and 3-5. Figure 3-3 illustrates 208/240 Vac connections, Figure 3-4 illustrates 410/450/480 Vac connections, and Figure 3-5 illustrates APR 125-5 interconnection with an isolation transformer. Figure 3-3. 208/240 Vac Interconnection Diagram 3-2 APR 125-5 Installation 9168800990 Rev J

Figure 3-4. 410/450/480 Vac Interconnection 9168800990 Rev J APR 125-5 Installation 3-3

Figure 3-5. Isolation Transformer Interconnection Connection Procedure 1. Configure the APR 125-5 for 50 or 60 Hz operation by connecting the terminal block jumper across the COM and 50 Hz or COM and 60 Hz terminals. 2. If a CBS 320 Current Boost System will be used with the APR 125-5, remove the jumper connected across terminals CB and CB+ and connect the CBS 320 to these terminals. If a CBS 320 is not used, leave the jumper across terminals CB and CB+ in place. 3. If the external voltage adjust potentiometer (supplied with the APR 125-5) will be used, connect it across terminals 6 and 7 as shown in Figures 3-3 through 3-5. If the potentiometer won t be used, connect a jumper across terminals 6 and 7. 4. Observing the proper polarity, connect terminals F+ and F to the exciter field. 5. Connect APR 125-5 operating power from the generator stator to terminals 3 and 4-E3. The applied voltage must be within the range of 190 to 277 Vac. Both operating power inputs should be protected with fuses. If desired, install an optional shutdown switch. 6. Connect the sensing voltage source to terminals 240 (E1) and 4-E3 or 480 (E1) and 4-E3. These connections should be connected line-to-line and depend upon the voltage level of the sensing source. 3-4 APR 125-5 Installation 9168800990 Rev J

SECTION 4 OPERATION INTRODUCTION The following procedures provide instructions for starting, operating, and adjusting the APR 125-5 voltage regulator. A troubleshooting guide lists symptoms of startup problems that may result from incorrect regulator adjustment and certain generator system problems that resemble faulty regulation with possible solutions. NOTE During periods of prime mover idling (operation at reduced speeds), use the shutdown switch to remove voltage regulator operating power. PRELIMINARY SETUP To prevent damage to the voltage regulator, the following precautions should be taken before proceeding with system startup. Verify that the voltage regulator specifications conform with the generator system requirements. Ensure that the voltage regulator has been installed and connected in accordance with Section 3. SYSTEM STARTUP Table 4-1 lists the steps associated with system startup, the problems that may be encountered, and the possible solutions to these problems. Table 4-1. System Startup Procedure/Troubleshooting Guide Procedure Symptom Remedy 1. Perform the precautions N/A N/A listed under Preliminary Setup. 2. Start the prime mover and bring it up to rated speed. Voltage does not build up. a. Flash the field. b. Troubleshoot Voltage builds and then decays. Troubleshoot 3. Slowly adjust the VOLT adjustment or external voltage adjust potentiometer until the voltage reaches nominal. Voltage does not build up to rated value. Voltage is high and uncontrollable. a. Check the generator output for a shorted or excessive load. b. Troubleshoot Troubleshoot 4. Apply and remove load to check stability. 5. Check regulation under normal operating conditions. Generator response is too slow or is hunting (oscillating). Poor regulation. a. Check the generator output for shorted or excessive load. b. Troubleshoot a. Check that the prime mover is up to speed. b. Check that the voltmeter is connected at the same point as the regulator sensing. c. Use an average sensing voltmeter (not rms sensing). d. Troubleshoot 9168800990 Rev J APR 125-5 Operation 4-1

Procedure Symptom Remedy 6. Reduce the generator frequency to approximately 5 Hz below nominal. The generator output should decrease from this point. Generator output voltage does not decrease at the desired frequency. a. Check that all wiring is in accordance with Section 3. b. Adjust the regulator FREQ control. OVEREXCITATION SHUTDOWN The overexcitation shutdown function removes the regulator output power if the exciter field voltage exceeds 190 Vac. After regulator output power is shut down due to overexcitation, the regulator can be reset by decreasing the input voltage to less than 6 Vac for a minimum of 10 seconds. This can be accomplished by stopping the prime mover or by interrupting the regulator input with the shutdown switch. ADJUSTMENTS APR 125-5 adjustments include field flashing, frequency roll-off, stability, and voltage. Field Flashing When the voltage regulator is operated with the generator for the first time, the polarity of the generator s residual magnetism may be incorrect of insufficient magnitude. If the residual voltage present at terminals 3 and 4-E3 is greater than 6 Vac, replace the regulator. If the generator residual voltage is less than 6 Vac, stop the prime mover and proceed with the following steps. CAUTION Do not flash the field with the generator in motion. The voltage regulator may be damaged. 1. With the prime mover at rest, apply a dc source (ungrounded), of not more than 48 Vdc to terminals F+ (positive) and F (negative) in series with a limiting resistor. Use 1 Ω of resistance for each volt from the dc power source. The resistor should have a power rating of at least 1 watt per ohm. 2. Allow the field to be flashed for approximately 10 seconds before removing the dc source. 3. If voltage buildup does not occur after performing steps 1 and 2, verify the polarity of the dc source and repeat flashing as necessary. Frequency Roll-Off Adjustment The APR 125-5 underfrequency adjustment is factory preset to cause an average 2 Vac drop in the generator line input voltage to the regulator when the frequency is between 55.0 and 55.6 hertz (for 60 Hz applications). For 50 hertz applications, the frequency roll-off is factory preset to between 45.75 and 47.75 hertz. To reset the frequency roll-off, proceed as follows: 1. Adjust the prime mover rpm to the desired frequency compensation (corner frequency roll-off) point. 2. Adjust the front panel FREQ control until the output voltage begins to drop off. 3. Bring the prime mover up to rated speed. The output voltage should return to normal. Stability Adjustment An oscilloscope or other voltage recording device should be used if a stability setting is desired that will provide the fastest possible voltage response with good generator stability. When adjusting regulator stability, note the following: Clockwise rotation of the front panel STAB control slows response time. Counterclockwise rotation of the front panel STAB control speeds response time. If rotated too far counterclockwise, the generator voltage may oscillate (hunt). Rotate the front panel STAB control counterclockwise until the system starts oscillating and then rotate the control clockwise just pas the point where oscillation occurred. 4-2 APR 125-5 Operation 9168800990 Rev J

Voltage Adjustment Installation of a jumper across terminals 6 and 7 enables the front panel VOLT control to adjust the generator nominal voltage over the range shown in Table 1-1. The external potentiometer, supplied with the APR 125-5, may be connected in place of the jumper and will allow for a 10% adjustment of the voltage range. The nominal value of this range is set by the front panel VOLT control. If a range less-than or greater-than that provided by the supplied 5 kω potentiometer is desired, a 2 watt potentiometer of any value from 1,000 to 10,000 ohms may be substituted. OPERATIONAL TEST To perform an operational test of the APR 125-5, connect the regulator as shown in Figure 4-1 and perform the following steps. Figure 4-1. APR 125-5 Operational Test Setup 1. Apply 240 Vac to the regulator as shown in Figure 4-1. 2. Adjust the front panel VOLT control fully counterclockwise. Observe that the lamps do not light. 3. Adjust the front panel VOLT control fully clockwise. Observe that the lamps light. 4. Adjust the front panel VOLT control counterclockwise until the lamps just turn off. Regulator operation is satisfactory if the above results are obtained. Stability, however, must be tested with the generator and regulator operating. 9168800990 Rev J APR 125-5 Operation 4-3

This page intentionally left blank. 4-4 APR 125-5 Operation 9168800990 Rev J

SECTION 5 MAINTENANCE PREVENTIVE MAINTENANCE The APR 125-5 voltage regulator requires no periodic maintenance other than periodic inspection to ensure that the regulator is clean and free from accumulations of dust and moisture. Be sure that all terminal connections are clean and tight. TROUBLESHOOTING If the regulator does not perform as expected, consult Table 5-1 for assistance with troubleshooting. Table 5-1. Troubleshooting Symptom Possible Cause Remedy Voltage does not build up. No voltage or incorrect voltage to power input at terminals 3 and 4-E3. a. Flash the field. b. Verify all wiring. c. Check the fuses. d. Check the shutdown switch. e. Replace the regulator. Voltage builds and then decays. Voltage does not build to rated value. Overexcitation circuit is shutting off regulator Open the external voltage adjust potentiometer connected across terminals 6 and 7. Defective regulator Terminals CB+ and CB are not jumpered. Stop the prime mover and then restart (watch for high voltage). Replace the external voltage adjust potentiometer or the jumper across terminals 6 and 7. Replace the regulator Install jumper across terminals CB+ and CB. Voltage high and uncontrollable Generator response too slow or is hunting (oscillating). Poor regulation Wrong sensing tap selected. Internal or external voltage adjustments are improperly set. Faulty regulator No sensing input Wrong sensing tap Faulty regulator Improper front panel STAB adjustment Faulty regulator Field resistance not matched to regulator capability or the regulator output rating is too low for the generator requirements. Incorrect jumper selection for 50 or 60 Hz operation Low prime mover speed Check sensing tap. Adjust the front panel VOLT control and/or external voltage adjust potentiometer. Replace the regulator Verify wiring Check sensing tap Replace the regulator. Readjust front panel STAB control. Replace the regulator. Verify specifications Check for improper frequency jumper installation Verify prime mover speed 9168800990 Rev J APR 125-5 Maintenance 5-1

This page intentionally left blank. 5-2 APR 125-5 Maintenance 9168800990 Rev J

ROUTE 143, BOX 269 HIGHLAND, IL 62249 USA http://www.basler.com, info@basler.com PHONE +1 618-654-2341 FAX +1 618-654-2351