TABLE OF CONTENTS 1. FEATURES CAUTION OF ELECTROMAGNETIC FIELD EXPOSURE SPECIFICATIONS...2

Similar documents
Three axis ( X, Y, Z ) electromagnetic field measurement 3 D EMF TESTER. Model : EMF-828

EMF TESTER OPERATION MANUAL. ELECTROMAGNETIC FIELD RADIATION TESTER Model : EMF-832

MANUAL ELECTROMAGNETIC FIELD RADIATION TESTER EMF 823

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

Instruction Manual. IM-191 Magnetic Field Meter

DIGITAL 5000 g x 1 g FORCE GAUGE TENSION & COMPRESSION

Model LE-300C/LH-300C/LZ-300C Coating Thickness Tester. Operating Manual

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Breath Alcohol Tester

MAGNETIC EFFECTS OF ELECTRIC CURRENT

Digital Force Gauge with RS232 Output Instruction Manual

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Autoranging Multimeter

TES-1601 INSTRUCTION MANUAL AUTORANGING INSULATION TESTER SAFETY INFORMATION TES ELECTRICAL ELECTRONIC CORP. Warnings and Safety symbols:

OPERATING INSTRUCTION

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

SA1W: Water Detection Sensors

EMF Readings in Tollgate Crossing community Robert L. Vaessen - 22 Dec 2016

Pre-lab Questions: Please review chapters 19 and 20 of your textbook

Experimental Question 1: Levitation of Conductors in an Oscillating Magnetic Field

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Compact Scales. Software Revision V1.25 & above

No.LV31JE To prevent accidents arising from the misuse of this instrument, please ensure the operator receives this manual.

True RMS Autoranging Multimeter

INSULATION RESISTANCE TESTER FOR PHOTOVOLTAIC SYSTEMS MSEI-200C INSTRUCTION MANUAL

DPS280 / DVS280 Series

JINLONG MACHINERY & ELECTRONICS CO., LTD. PRODUCT SPECIFICATION

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

2-Color Display High-Precision Digital Pressure Switch

OPERATING MANUAL PLS HLE 1000 PACIFIC LASER SYSTEMS. The Professional Standard

SSP-7080 USER MANUAL. 80W Constant Power Switching Mode Power Supply with Master & Slave Remote Sensing. Rev /

Marin Control Digital

Model Insulation Tester / Megohmmeter. User Manual

MICRO SWITCH ESS SERIES

PCS 100 SYSTEM INSTALLATION INSTRUCTIONS

Transmitter CSA-591 Instruction Manual

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Advanced Test Equipment Rentals ATEC (2832)

Digital/Analog Megohmmeter Model 1026 USER MANUAL

EW-38. Owner s Manual. (888)

Easy Weigh ADVANCED COUNTING SCALE MODEL: AC-100 OWNER S MANUAL VER 1.00

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

PRODUCT SPECIFICATION

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

Electromagnetic Induction (approx. 1.5 h) (11/9/15)

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Check-Rod Type Mounting Attachment with Slide Stop Mechanism CCACC010- B (S) Instruction Manual EN E

DIGITAL RCD(ELCB) TESTER

Pre-lab Questions: Please review chapters 19 and 20 of your textbook

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

Instruction Manual. Coating Thickness Gauge. Optionally with Memory

SA1W: Water Detection Sensors SA1W-FN1 SA1W-FN2 SA1W-FP1 SA1W-FP2

Weighing Scale IDS-802. User Manual

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Illustrations. Contents. Burns Connection Head. Models #22, #23 & #24 with Battery Powered LCD Indicator Instruction Manual

1 Form A 5A small size power relay for interface

Autoranging Industrial Multimeter

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

C.T.M. MOBILITY SCOOTER

Breath Alcohol Tester

Digital/Analog Megohmmeter Model 1026

General safety and installation information.

DISSECTIBLE TRANSFORMER - large

1.Safe testing IMPORTANT:

C.T.M. MOBILITY SCOOTER. HS-125 Instruction Booklet

PA39 TYPE PANEL POWER METERS APPLICATION CHOICE OF MEASURING RANGE TECHNICAL DATA. Additional errors

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

OPERATION MANUAL Common for All models Bobbin Sensor (Weft End Detection) DP150 - L2 BP150 - L2-12V BP150 - L2-24V (PNP/NPN)

Wire Wound Chip Inductor (Ferrite)-NL Series

VA-7000 SERIES ACTUATOR

Specification Approval Sheet

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

RATE CONTROLLED TORQUE WRENCH TESTER

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

Physics 121 Practice Problem Solutions 11 Faraday s Law of Induction

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Cable Length Meter INSTRUCTION MANUAL

TMA5 Mini Vane Anemometer

Table of Contents 1. OVERVIEW OPERATION FUNCTION SPECIFICATIONS INSTRUMENT LAYOUT INSTALLATION...

Dawson DDM190D. Digital Multimeter User s Manual

Wire Wound Chip Inductor Ferrite

GH-5S. 5.6 times approx. Tightening torque 0.78N m or less. Disconnection Alarm Indicator

12:1 WIDE-RANGE INFRARED THERMOMETER WITH STAR BURST LASER TARGETING

DIGITAL CLAMP TESTER MODEL HCL-5000D

AP Physics B: Ch 20 Magnetism and Ch 21 EM Induction

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

Analog Input Terminal

How to Degauss Car Tires

LP4300 FLOOR SCALE OPERATION INSTALLATION AND SERVICE MANUAL

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

TV-5, TV-8 rated 10mm flat power relays Silent type is available

AT8060 BREATH ALCOHOL TESTER USING MANUAL. Ver: HW Catalogue

Transcription:

TABLE OF CONTENTS 1. FEATURES...1 2. APPLICATIONS...1 3. CAUTION OF ELECTROMAGNETIC FIELD EXPOSURE...1 4. SPECIFICATIONS...2 5. FRONT PANEL DESCRIPTION... 3 5-1 Display...3 5-2 EMF Sensor Position...3 5-3 OFF/micro Tesla/milli Gauss Switch...3 5-4 Battery Cover/Compartment...3 6. MEASURING PROCEDURE...4 7. RECOMMENDATION...5 8. BATTERY REPLACEMENT...5

1. FEATURES * The EMF tester is designed to provide user a quick, reliable and easy way to measure electromagnetic field radiation levels around power lines, home appliances and industrial devices. * The EMF tester is a cost effective, hand-held instrument designed and calibrated to measure electromagnetic field radiation at different bandwidths down to 50 Hz/60 Hz. * Display micro Tesla & milli Gauss in the same tester. 2. APPLICATIONS This EMF tester is specifically designed to determine the magnitude of electromagnetic field radiation generated by power lines, computer's monitor, TV sets, video machinery and many other similar devices. 3. CAUTION OF ELECTROMAGNETIC FIELD EXPOSURE Claims by some scientists that long term exposure to electromagnetic field may be the cause of childhood leukemia & other forms of cancer. Complete answers to any of these and related questions are not currently available. At the present time the most common practice is to avoid excess exposure over long period of time. "Prudent Avoidance" as stated by the Environmental Protection Agency(EPA) USA is recommended. 1

4. SPECIFICATIONS Display 13mm (0.5") LCD, 3 1/2 digits. Max. indication 199.9. Range/Resolution Two function : micro Tesla & milli Gauss : 20 micro Tesla x 0.01 micro Tesla 200 milli Gauss x 0.1 milli Gauss * 1 micro Tesla = 10 milli Gauss Band width 30 Hz to 300 Hz. Number of Axes Single axis. Accuracy ± ( 4 % + 3 d ) at 50 Hz or 60 Hz. Over-input Display shows " 1 ". Sampling Time Approx. 0.4 second. Battery DC 9 V battery (006P, 6F22). Power Current Approx. DC 3 ma. Operating Temp. 0 to 50 ( 32 to 122 ). Operating Less than 80% R.H. Humidity Weight 165 g/0.36 LB (including battery). Dimension H.W.D. - 131x70x25 mm (5.2x2.8x1.0 inch). Accessories Operation Manual... 1 PC. Included 2

5. FRONT PANEL DESCRIPTION Fig. 1 5-1 Display 5-2 EMF Sensor Position 5-3 OFF/micro Tesla/milli Gauss Switch 5-4 Battery Cover/Compartment 3

6. MEASURING PROCEDURE 1) Place the " OFF/micro Tesla/milli Gauss Switch " ( 5-3, Fig. 1 ) to the " milli Gauss " or " micro Tesla " position according the measurement requirement. Tester is now ready to take the measurement. Due to the electromagnetic interference of the environment, the display reading may show small values before testing, for example less than 0.5 gauss. This is not malfunction of the tester. 2) With the tester in hand, move slowly towards to the object under measurement until it is physically touched. * Notice how the field intensity increases as you move closer to the object. 3) Position the EMF tester at different angles to the object under measurement and observe how this may affect your reading. 4) By trying different angles approaching the object under measurement, recorder the highest value shown on the display. If the object under measurement is turned off during the measurement, the EMF tester reading should then return to zero, unless a field from other sources are detected. 4

7. RECOMMENDATION It is recommended to measure the presence of the electromagnetic field inside and outside of your home and business locations regularly. As "hot spots" are detected by the EMF tester, re-arrangement of the living and working areas is lightly recommended. Always try the best to avoid long term exposure to strong electromagnetic field. 8. BATTERY REPLACEMENT 1) When the left corner of the LCD display shows "LO BAT", Replacement of the battery is then needed. However measurement could still be taken for another few hours before the tester becomes inaccurate. 2) Open the Battery Cover (5-4, Fig 1) at the back of tester and remove the battery. 3) Replace with a 9V battery and reinstate the cover. 5 0805-EMF822A