MANUAL ELECTROMAGNETIC FIELD RADIATION TESTER EMF 823

Similar documents
EMF TESTER OPERATION MANUAL. ELECTROMAGNETIC FIELD RADIATION TESTER Model : EMF-832

Three axis ( X, Y, Z ) electromagnetic field measurement 3 D EMF TESTER. Model : EMF-828

TABLE OF CONTENTS 1. FEATURES CAUTION OF ELECTROMAGNETIC FIELD EXPOSURE SPECIFICATIONS...2

Manual Calibrator PCE-IC1

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

Instruction Manual. IM-191 Magnetic Field Meter

Manual Thickness gauge PCE-CT 30

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

2-Color Display High-Precision Digital Pressure Switch

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

USER MANUAL. Insulation Tester + DMM. Model MG320

Manual Rotation Meter PCE-AT 5

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

Model LE-300C/LH-300C/LZ-300C Coating Thickness Tester. Operating Manual

Manual Balanza dosificadora PCE-ABZ 200C

1.Safe testing IMPORTANT:

DLRO10HDX 10 Amp Digital Low Resistance

Autoranging Multimeter

INSTRUCTION MANUAL VISCOTESTER VT-05 / VT-06 PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

Instruction Manual. Coating Thickness Gauge. Optionally with Memory

2-Color Display Digital Pressure Switch. NPN/PNP open collector 2 outputs added. Cut-to-zero display function added. Rated Pressure Metal Body Type

DPS280 / DVS280 Series

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

THT-500-A/R INSTRUCTION MANUAL TEMPERATURE AND HUMIDITY TRANSMITTER

DIGITAL RCD(ELCB) TESTER

True RMS Autoranging Multimeter

Autoranging Industrial Multimeter

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

Clamp Earth Tester MET-2. Instruction Manual

DIGITAL FORCE GAUGE FM-204

2-Color Display Digital Pressure Switch. Rated Pressure Metal Body Type (ISE75H) 2-color digital. Functions

WalkLAB Digital Dissolved Oxygen meter HD9030

KMP Insulation-Continuity Tester. Users Manual

NPS Series. Pallet Jack Scale Operator s Guide (V1611)

MANUAL PCE-IT111

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

AZ-8904 THERMO ANEMOMETER

User Guide. Model Insulation Tester / Megohmmeter

OPERATING INSTRUCTION

KMP7010. Ground Resistance Tester. Users Manual

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

Virtual Measurements & Control. VC210 Operators Manual

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

Dawson DAN100. Analog Multimeter User s Manual

SCALIX MULTIPURPOSE SCALES SCALIX COMPACT SCALE FKS-600 FKS-6000 INSTRUCTION MANUAL

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Mini Multimeter with Non-Contact Voltage Detector (NCV)

INTRODUCTION. Backlight for operating in dark area Low battery indicator Auto power off function. CO levels and its effect

Dawson DDM190D. Digital Multimeter User s Manual

Interactive Whiteboard. User Guide. Before operating the unit, please read this manual thoroughly, and retain it for future reference

Digital Force Gauge with RS232 Output Instruction Manual

ROGOWSKI LEAK METER MODEL RLM-1

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

Closed Cup Flash Point Tester

Digital/Analog Megohmmeter Model 1026

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Safety design conforming to the following provisions

Model Insulation Tester / Megohmmeter. User Manual

General safety and installation information.

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

Pressure measurements can easily be taken any time, anywhere. POWER LIGHT

DIGITAL 5000 g x 1 g FORCE GAUGE TENSION & COMPRESSION

Digital/Analog Megohmmeter Model 1026 USER MANUAL

LM-100 LM-120. Light Meters. Users Manual. For detailed specifications and ordering info go to

Weighing Scale IDS-802. User Manual

Illustrations. Contents. Burns Connection Head. Models #22, #23 & #24 with Battery Powered LCD Indicator Instruction Manual

Safety design conforming to the following provisions

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

Mini Multimeter with Non-Contact Voltage Detector (NCV)

Lumitester PD-30. Instruction Manual. Table of Contents

USER GUIDE. Model RH10 Hygro Thermometer. Humidity and Temperature Meter

FrelTec GmbH. Wire Wound Ceramic Chip Inductors SMD

Compact Scales. Software Revision V1.25 & above

User Manual. CFM/CMM Vane Thermoanemometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

WIRELESS TRI-JACK WIRELESS REMOTE KIT COMPONENTS LITERATURE NUMBER REV. C WARNING EXPLOSION WARNING PERSONAL INJURY & PROPERTY DAMAGE

3. Input KJ: Thermocouple P: Platinum resistance thermometer G: Thermistor T: Thermocouple/platinum resistance thermometer (universal-input)

WIRELESS CAMPER JACK LITERATURE NUMBER REV. C CCD WARNING PERSONAL INJURY & PROPERTY DAMAGE WARNING EXPLOSION. Effective NOV 2018

AUTOMOTIVE LOW PROFILE MICRO-ISO/MICRO-280 RELAY

TABLE OF CONTENTS. Introduction

MANUAL DE INSTRUÇÕES DO ANEMÔMETRO DIGITAL MODELO AN-3040

1. D-Lux Introduction ENGLISH Parts & Components Product Overview. 4. Precautions. 5. Hand-piece Components Installation

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Hot Wire CFM/CMM Thermo-Anemometer

Noncontact Thermometer

PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL USA From outside US: +1 Tel: (561) Fax: (561)

Manual KREBS Viscometer PCE-RVI 5

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

SSI Technologies Application Note PS-AN4 MediaGauge (Model MG-9V) Digital Pressure Gauge Product Overview

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

MIT300 Series Insulation and Continuity Testers

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

Transcription:

www.pce-industrial-needs.com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co. Durham DH6 5PG United Kingdom Phone: +44 ( 0 ) 191 377 3398 Fax: +44 ( 0 ) 191 377 3357 info@tursdaletechnicalservices.co.uk http://www.industrial-needs.com/ MANUAL ELECTROMAGNETIC FIELD RADIATION TESTER EMF 823

Your purchase of this EMF TESTER marks a step forward for you into the field of recision measurement. Although this EMF TESTER is a complex and delicate instrument, its durable structure will allow many years of use if proper operating techniques are,developed. Please read the following instructions carefully and always keep this manual within easy reach. Table of contents 1.Features... 3 2. Applications... 3 3. Caution of Electromagnetic Field Exposure... 3 4. Specifications... 4 4-1 General Specifications... 4 4-2 Electrical Specifications... 5 5. Front Panel Description... 5 6. Measuring Procedure... 6 6-1 EMF measurement... 6 6-2 Data Hold... 7 6-3 Data Record... 7 6-4 Display backlight On/Off... 7 6-5 Auto power OFF disable... 7 7. Battery Replacement... 7 8. Optional Accessories... 8 2

1.Features * The EMF tester is designed to provide user a quick, reliable and easy way to measure electromagnetic field radiation levels around power lines, home appliances and industrial devices. * Three EMF measuring ranges, 20 micro Tesla/200 micro Tesla /2000 micro Tesla and 200 mg/2000 mg/20000 mg. * The EMF tester is a cost effective, hand-held instrument designed and calibrated to measure electromagnetic field radiation at different bandwidths down to 50 Hz/60 Hz. * Microprocessor circuit assures high accuracy and provides special functions and features. * Records Maximum, Minimum readings with Recall. * LCD dspaly is with the backlight installation. * Auto power Off or manual power Off. * Data hold. * Operates from 006P DC 9V battery. * Heavy duty & compact housing case. 2. Applications This EMF tester is specifically designed to determine the magnitude of electromagnetic field radiation generated by power lines, computer's monitor, TV sets, video machinery and many other similar devices. 3. Caution of Electromagnetic Field Exposure Claims by some scientists that long term exposure to electromagnetic field may be the cause of childhood leukemia & other forms of cancer. Complete answers to any of these and related questions are not currently available. At the present time the most common practice is to avoid excess exposure over long period of time. "Prudent Avoidance" as stated by the Environmental Protection Agency(EPA) USA is recommended. 3

4. Specifications 4-1 General Specifications Display LCD size : 48.8 mm x 25.3 mm. LCD is with the backlight installation. Circuit Custom one-chip of microprocessor LSI circuit. Measurement EMF ( Electromagnetic field radiation ) EMF micro Tesla : Range 20 micro Tesla x 0.01 micro Tesla /Resolution 200 micro Tesla x 0.1 micro Tesla 2,000 micro Tesla x 1 micro Tesla milli-gauss : 200 mg x 0.1 mg 2,000 mg x 1 mg 20,000 mg x 10 mg * mg : milli-gauss * 1 micro Tesla = 10 milli-gauss EMF Band 30 Hz to 300 Hz. Axes no. of Single axis. Over-input Sampling Time Approx. 1 second. Battery DC 9 V battery (006P, 6F22). Power Current Approx. DC 5 ma. * Back light Off. Operating 0 to 50. Temperature Operating Less than 80% R.H. Humidity Dimension Weight Accessories Included Optional Accessories 152 x 69 x 36.3 mm ( 6.0 x 2.7 x 1.4 inch). 216 g/0.48 LB. Operation Manual... 1 PC. * Soft carrying case, CA-52A * AC to DC 9V power adapter. 4

4-2 Electrical Specifications Range Resolution 20 micro Tesla 0.01 micro Tesla 200 micro Tesla 0.1 micro Tesla 2,000 micro Tesla 1 micro Tesla 200 mg 0.1 mg 2,000 mg 1 mg 20,000 mg 10 mg * mg : milli-gauss * 1 micro Tesla = 10 milli-gauss Range Accuracy 20 micro Tesla ± (4 % + 3 d) 200 micro Tesla ± (5 % + 3 d) 2,000 micro Tesla ± (10 % + 5 d) 200 mg ± (4 % + 3 d) 2,000 mg ± (5 % + 3 d) 20,000 mg ± (10 % + 80 mg) * Spec. accuracy tested under 50 Hz or 60 Hz. @ Above specification tests under the environment RF Field Strength less than 3 V/M & frequency less than 30 MHz only. 5. Front Panel Description 5-1 Display 5-2 Power Button 5

5-3 REC Button 5-4 HOLD Button 5-5 Range Button 5-6 Unit Button 5-7 Backlight Button 5-8 Tripod Fix Nut 5-9 Stand 5-10 Battery Cover/Compartmen 5-11 DC 9V Power Adapter Input Socket 5-12 EMF Sensor Position 6. Measuring Procedure 6-1 EMF measurement 1) Power On the meter by pressing the " Power Button " ( 5-2, Fig. 1 ) once. Select the suitable range by pressing the " Range Button " ( 5-5, Fig. 1 ) Select the unit ( ut. mg ) by pressing the " Unit Button " ( 5-6, Fig. 1 ) * ut : micro Tesla, mg " milli-gauss. * For the unknown EMF measurement, start with the highest range and keep decreasing until the higher resolution's reading is obtained. 2) With the tester in hand, move slowly towards to the object under measurement until it is physically touched. The upper Display ( 5-1, Fig. 1 ) will present the EMF measurement value. * EMF Sensor Position is in the area of " 5-13, Fig. 1 ". * Due to the electromagnetic interference of the environment, the display reading may show small values before testing, for example less than 0.05 micro Tesla. This is not malfunction of the tester. * Notice how the field intensity increases as you move closer to the object. 3) Position the EMF tester at different angles to the object under measurement and observe how this may affect your reading. 4) By trying different angles approaching the object under measurement, recorder the highest value shown on the display. * If the object under measurement is turned off during the measurement, the EMF tester reading should then return to zero, unless a field from other sources are detected. Recommendation for EMF measurement It is recommended to measure the presence of the electromagnetic field inside and outside of your home and business locations regularly. As "hot spots" are detected by the EMF tester, rearrangement of the living and working areas is lightly recommended. Always try the best to avoid long term exposure to strong electromagnetic field. 6

6-2 Data Hold During the measurement, press the Hold Button (5-4, Fig. 1) once will hold the measured value & the LCD will display a " HOLD " symbol. * Press the Hold Button once again will release the data hold function. 6-3 Data Record ( Max., Min. reading ) * The data record function records the maximum and minimum readings. Press the "REC Button" (5-3, Fig.) 1 ) once to start the Data Record function and there will be a " REC " symbol on the display. * When the " REC " symbol on the display : a) Press the " REC Button " ( 5-3, Fig. 1 ) once, the " REC MAX " symbol along with the maximum value will appear on the display. If intend to delete the maximum value, just press the " Hold button " ( 5-4, Fig. 1 ) once, the display will show the " REC " symbol only & execute the memory function continuously. b) Press the " REC button " ( 5-3, Fig. 1 ) again, the "REC. MIN." symbol along with the minimum value will appear on the display. If intend to delete the minimum value, just press the " Hold button" ( 5-4, Fig. 1 ) once, then the display will show the " REC " symbol only & execute the memory function continuously. c) To exit the memory record function, just press the " REC " button for 2 seconds at least. The display will revert to the current reading. 6-4 Display backlight On/Off During the measurement, the LCD backlight will On. If press the '" Backlight Button " ( 5-7, Fig. 1 ) once, the LCD backlight will be switched to Off. * Press the " Back light Button " once again will switch the Display backlight installation On again. 6-5 Auto power OFF disable The instrument has built-in " Auto Power OFF " in order to prolong battery life. The meter will switch off automatically if none of the buttons are pressed within 10 min. To de-activate this feature, Select the memory record function during measurement by pressing the " REC Button " ( 5-3, Fig. 1 ). 7. Battery Replacement 1) When the left corner of LCD display show ", is necessary to replace the battery. However, inspec. measurement may still be made for several hours after low battery indicator appears before the instrument become inaccurate. 2) Slide the " Battery Cover " ( 5-10, Fig. 1 ) away from the instrument and remove the battery. 3) Replace with 9V battery ( Alkaline or Heavy duty type ) and reinstate the cover. 4) Make sure the battery cover is secured after changing the battery. 7

8. Optional Accessories Soft carrying case Model : CA-52A DC 9V POWER ADAPTER Model : AP-9VA PLUG CONVERTER Model : AP-GTU PLUG CONVERTER Model : AP-GTE * Soft carrying case with sash. * Size : 200 x 80 x 50 mm. * Input voltage : 100 to 240 ACV, 50/60 Hz. * Output voltage : Regulation DC 9V/ 1 Amp. rating max. * Output plug : round 2.5 mm dia. plug. * Convert the input plug of AP-9VA, from the Germany type to USA type. * Convert the input plug of AP-9VA, from the Germany type to UK ( England ) type. In this direction will find a vision of the measurement technique: http://www.industrial-needs.com/measuring-instruments.htm NOTE: "This instrument doesn t have ATEX protection, so it should not be used in potentially explosive atmospheres (powder, flammable gases)." 8