Nissin s Products for Electric Railway System

Similar documents
MV Air Insulated Switchgear TAP17. Technical Data TGOOD

GAS INSULATED VOLTAGE TRANSFORMERS.

Unrestricted. Air Core Reactor Applications Current Limiting Reactors

33 KV STATIC SHUNT CAPACITOR WITH ALLIED EQUIPMENT

Power Interchange System for Reuse of Regenerative Electric Power

Outdoor live tank vacuum circuit breaker Type OVB-VBF for 24/36/40.5 kv applications

EMPAC Metal enclosed capacitor bank for wind applications

Activity of YASKAWA for Industrie 4.0 -Focus on Robotics-

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

AIR CORE REACTORS. Phoenix Electric Corporation

Global and China Aluminum Electrolytic Capacitor Market Report, August 2011

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Capacitor Related Definitions

Small wonder. Station service voltage transformers for small power requirements

HARYANA VIDYUT PRASARAN NIGAM LTD.

EH2741 Communication and Control in Electric Power Systems Lecture 3. Lars Nordström Course map

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Power Protection Discrete Automation & Motion South Africa

Dynamic Reactive Power Control. By V. R. Kanetkar Full Time Consultant Technical Services at Veretiv Energy Private Limited Thane (West)

Raising the bar. UHV switchgear and components

Overview of Mitsubishi Electric's Transportation Business & Power Device Technology January, 2017 Mitsubishi Electric Corporation

B kv Gas-insulated Substations

Transforming Energy.. For Advanced Technology

M-RING 24. SF6 Insulated Ring Main Unit Metal-Enclosed (LSC2A)

Increasing Wanzhou Power Transfer Capability by 550kV Fixed Series Capacitor FSC Fengjie

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Study of composition draft on automatic changeover system in neutral section railway catenary system for highspeed train line

Independent Testing Laboratory for High Voltage Equipment

Impulse Voltage Test System, Q Structure, kV

Gas Insulated Switchgear

HV Compensation & Filtering Products

NXPLUS C Single busbar. Maintenance-free for lifetime

Vacuum Circuit Breaker VS1

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE - B - C - en - REV

Power Factor Correction

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

CP Automatic capacitor bank

POWER QUALITY SEMINAR OF IRAN, 2 ND MARCH 2017 Power Quality Seminar. Abel-Zhang,Power Quality Center Manager

DESIGN CONSIDERATIONS FOR APPLICATION OF SHUNT CAPACITORS IN HEAVY HATER PLANT (TUTICORIN)

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

KOREA INDONESIA COMPANY NAME SAMWHA CAPACITOR CO., LTD. ESTABLISHMENT AUGUST 1956 HEADQUARTER USD10,000,000 CAPITAL REVENUE USD150,000,000 (2009)

Product brochure. Gas-insulated switchgear ELK-4, 800 kv Pioneering technology for extra-high voltage applications

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

TECHNICAL SPECIFICATIONS OF PCC PANEL

Renovation 2018 FY2018 Medium-Term Management Plan April 28, 2016 Fuji Electric Co., Ltd.

Large-scale Photovoltaic Power Generation Systems

Sri Lanka Japan Business Forum Overview of SG Holdings Group

MODELLING OF 25 kv ELECTRIC RAILWAY SYSTEM IN EMTP-RV

3AP1 DTC for 145 and 245 kv

Substation Maintenance Training

China. Fig. 1 Chain SVG Electrical Diagram

ABB Transformers For reliability, efficiency and minimum environmental impact

Sr. No. Details Page No. 1 MV Capacitor Unit Drawings 3. 2 Technical Perticular for Capacitor Unit 4. 3 MV Surge Capacitor Unit Drawings 6

High voltage in motion Environmentally friendly circuit breakers and economic long-rod insulators

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

Supporting Industry for a Century

ABB FACTS Grid connection of Wind Farms

Air-insulated switchgear UniGear type ZS1

Management Plan for FY2013

The Development of ±800kV/4750A UHVDC Valve & HVDC/FACTS Status in China. For EPRI HVDC & FACTS Conference Aug. 30, 2011 Palo Alto, California, USA

ELG4125: Flexible AC Transmission Systems (FACTS)

The Application of Power Electronics to the Alberta Grid

Gas Insulated Switchgear

MEDIUM VOLTAGE CE-B36 METAL CLAD SWITCHBOARDS. CE - B36 - C - en - REV

Medium voltage vacuum circuit breaker. E-VAC series

Estimation of electrical losses in Network Rail Electrification Systems

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

ASN3 ASN2 ASN1. ASN Series Medium voltage, metal-clad, air-insulated switchgear for primary distribution

CAST RESIN TRANSFORMERS

CPG.1 Gas insulated, single busbar cubicle range Up to 27 kv / 2000 A / 31.5 ka Up to 38 kv / 2000 A / 31.5 ka IEEE Standards

Power Voltage Transformers for Air Insulated Substations

Introduction to Power Electronics - A Tutorial. Burak Ozpineci Power Electronics and Electrical Power Systems Research Center

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

SUBSTATION DESIGN TRAINING

Up to 24kV Modular type Air insulated switchgear

Catalog HA Edition up to 24 kv, Air-Insulated, Extendable. Medium-Voltage Switchgear. siemens.com/simosec

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

3EK7 Distribution Class Surge Arresters. Answers for energy.

Interruption Technology of Breakers for High-voltage Direct Current

Magnetically Controlled Reactors Enhance Transmission Capability & Save Energy Especially in Compact Increased Surge-Impedance- Loading Power Lines

The 1,400-MW Kii-Channel HVDC System

KYN28A-12 (GZS1) A.C METALCLAD REMOVABLE SWITCHGEAR FOR INDOOR USE CHINATCS

7.0 Technical Guarantee Specification of 60MVA, 132/33kV Mobile Substation. TECHNICAL DATA SCHEDULE 60MVA, 132/33 kv MOBILE SUBSTATION

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

HIGH POWER RECTIFIER SYSTEMS

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

3EK7 Distribution Class Surge Arresters. Answers for energy.

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

PASS M0. Innovative solutions for distribution substations up to 170 kv

Vacuum Circuit Breaker

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

MEDIUM VOLTAGE CE-B METAL CLAD SWITCHBOARDS. CE-B-C-en-REV

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Smart Battery Systems. for Energy Storage

Annie-Qingwen Guo, Chief Engineer, ABB Xi an Power Capacitor Co., Ltd., November, 2016 New UHV Capacitor with Low Noise, Small Footprint, Anti-seismic

A Transient Free Novel Control Technique for Reactive Power Compensation using Thyristor Switched Capacitor

Review paper on Fault analysis and its Limiting Techniques.

Transcription:

Ref. No. EKF120927-PRWS Nissin s Products for Electric Railway System KYOTO, JAPAN September, 2012

Introduction of Nissin Electric as Prime Supplier of Equipment for Electric Railway System in Japan

Nissin Electric Co., Ltd. Outline of the Company Corporate Overview General information of Nissin Electric Co., Ltd. is as follows; Establishment: 1914 Capital: 10,252,840,000 (Equivalent to US$137 million) Net Sales: 105,000 million (Equivalent to US$1.4 billion (2011 Fiscal Year)) Number of Employees: 4,818(All Nissin Groups)

Nissin Electric Co., Ltd. Outline of the Company Product Lineup Nissin started its capacitor business in 1914 and expanded the manufacturing range to other substation equipment. Substation & Distribution Equipment Power Capacitors (Tank & Can Type) Power Transformers Shunt Reactors Thyristor Q Compensator (TQC/SVC) Instrument Transformers (CT, CVT & VT) Gas Insulated Switchgears (GIS) Circuit Breakers Photovoltaic (Solar Power) Systems Power Conditioner Thin Film Coating System Ion Implantation Systems for Semiconductor Industry Electron-Beam Processing Systems for Cross-Linking of Tires, Electric Wires, Films, Polyethylene Foam, etc. EV Charger Diesel Particulate Filter (DPF)

Nissin Electric Co., Ltd. Outline of the Company Umezu Headquarters & Factory (Kyoto) Nissin has 2 main factories (Kyoto & Gumma) in Japan. Site Area: 93,000m 2 Products Capacitor, Harmonic Filter Equipment, SVC, Power Transformer, Reactor, Grounding Fault Protective Discharger, Solar Power Equipment, Metal Clad Switchgear, Computer & Control System, EV Charger, Electron Beam Equipment

Nissin Electric Co., Ltd. Outline of the Company Maebashi Works (Gumma) Products Instrument Transformers (CT, CVT & VT) Gas Insulated Switchgears (GIS) Extra-High Voltage Test Laboratory Site Area: 186,700m 2

Nissin Electric Co., Ltd. Outline of the Company Nissin Global Operation (1) 3 Nissin is expanding its operation worldwide. Arteche Nissin, Sociedad Limitada Beijing Hongda Nissin Electric Co., Ltd. Nissin Hengtong Elctric Co.,Ltd Nissin Advanced Technology Electric (Dongguan) Co., Ltd. Dongguan Beijing Wuxi Taiwan Nissin Electric (Wujiang) Co.,Ltd. Nissin Electric Wuxi Co., Ltd. Nissin Electric (Wuxi) Co., Ltd. Nissin Electric (Thailand) Co., Ltd. Nissin Electric Vietnam Co., Ltd. Nissin Allis Electric Co., Ltd. Substation Equipment Business

Nissin Electric Co., Ltd. Outline of the Company Nissin Global Operation (2) 3 Nissin Advanced Coating (Shenyang) Co., Ltd. Nissin Advanced Technology Electric (Dongguan) Co., Ltd. Nissin Advanced Coating Indo Co., Ltd. Nissin Advanced Coating (Tianjin) Co., Ltd. Dongguan Taiwan Nissin Electric (Dalian) Technology Development Co.,Ltd. Nissin Ion Korea Co., Ltd. Nissin Ion Equipment USA Inc. Boston Texas Nissin Ion Hightech (Yangzhou) Co., Ltd. NHV Corporation Shanghai NHV America Inc. Nissin Allis Union Ion Equipment Co., Ltd. Nissin Allis Ion Equipment (Shanghai) Co., Ltd. Electron Beam Processing & Ion Implantation Business Fine Coating Business

Nissin s Products for Electric Railway System

Nissin s Product Lineup for Electric Railway System The below are the typical items we supply for electric railway system. Name of Equipment Filter Equipment Static Var Compensator Parallel Capacitor Series Capacitor Series Reactor Distribution Transformer Booster Transformer Grounding Fault Protective Discharger Capacitor Resister Device Capacitor Voltage Transformer Voltage Transformer Current Transformer Abbreviation FL SVC PC SrC SR D-TR BT GP CR Device CVT VT CT

Application of Nissin s Products for DC Feeding System A S/S B S/S TR D-TR D-TR Silicon Rectifie r High Speed Switch PC I-TR Signal Light 6600V PC I-TR Feeder (Trolley) 1500V Coupler SR FL Testing Equipment Rail

Application of Nissin s Products for AC Feeding System A S/S B S/S Feeding TR (Scott connection) D-TR D-TR Signal Light 6600V PC SrC PC Feeder (trolley) 20kV BT Testing Equipment PC SrC PC Rail

Application of Nissin s Products for Shinkansen (Japanese Bullet Train) FL 50Hz 154~275kV CVT Power Utility 66kV Line for Railway SVC 6.6kV Feeding S/S Feeding S/S 6.6kV 50kV AT Feeding GP SP Power Panel GP Feeding TR (Scott TR) PC CR-L Device SP GP VT (PD) CT GP Feeding TR (Scott TR) Power panel PC SVC

Nissin s Supplied Items for Shinkansen (Japanese Bullet Train) Nissin s Products have been adopted to the electrical system of Shinkansen (Japanese Bullet Train). CR Device Products Parallel Capacitor Static Var Compensator (SVC) Instrumental Transformers (CT/CVT) Remarks Nissin has overwhelming share. Nissin has overwhelming share. Nissin developed and supplied the first SVC for Shinkansen (Japanese Bullet Train) system. Nissin has overwhelming share. All Nissin Capacitors supplied for Shinkansen system are Tank Type Capacitors.

Nissin Capacitor Products (Comparison between Tank and Can Type Capacitor)

Tank type/can type Capacitor NSISSIN is manufacturing both Tank Type and Can Type Capacitor. Tank Type Capacitor 69 kv, 3-phase, 60 Hz, 40 Mvar Can Type Capacitor 69kV 3-phase 60 Hz 40Mvar Tank Type Capacitor is primary choice of Power Companies and Railroad Companies in Japan while Can Type Capacitors are usually used by smaller factories, buildings.

Comparison of Tank type and Can type Capacitor Equipment As a leading manufacturer of capacitors in Japan, Nissin have more than 96% share of the Japanese domestic market for Shunt Capacitor Equipment above 11kV class. Nissin can offer both tank-type and can-type capacitors. Ex. Rating : 33kV 3-phase 60Hz 15Mvar L=13% Tank type Can type Layout H3000 H3000 W7000 D5500 W9500 D9500 (Including Safety Fence) Approx. WT 20ton Approx. WT 13ton Main Component SC: Capacitor x 3 units SR: Series Reactor x 1 unit DC: Discharge Coil x 3 units SC: Capacitor with Internal Discharge Resistor x 6 racks (24 Capacitors) SR: Series Reactor x 1 unit NCT: Neutral Current Transformer x 1 unit

Comparison of Capacitor Unit Although initial cost of the Tank Type Capacitors is higher than Can Type Capacitor, its long-term reliability and quality is highly preferred by Japanese Power Companies, Railroad Companies and large factories. Estimated Product Life Cycle Maintenance Discharge Device Space to be Occupied Safety Manufacturing Range of Capacity Tank type Longer 30 Years Easier Maintenance is for a few capacitor units and bushings only. Shorter Device: Discharge Coil Discharge time : 5 sec. after opening the switch of the capacitor bank. Smaller Safety distance is not necessary Safer Surface of the tank is not live part. Up to approx. 40,000kvar/unit Can type Shorter 20 Years Complicated It requires the maintenance for many capacitor units, racks, bushings and insulators. Also, replacement of the capacitor units is required within shorter period as the life cycle of capacitor is shorter. Longer Device: Discharge Resistor (Built-in) Discharge time : 5 min. after opening the switch of the capacitor bank. Larger Safety distance is necessary Less Safe Capacitors and rack are live part. It must be surrounded by fence so that people will not access to the live part. Up to approx. 600kvar/unit

Specification of Nissin Products for High-Speed Railway System

CR Device General Specification of CR Device we supplied for Shinkansen System is as follows; Item Ratings CR Device Capacitor Unit: Tank Type Reactor: Oil-Immersed Type Rated Voltage Number of Phase Rated Frequency Rated Current Rated Harmonic Current (Continuous) Rated Capacity Resistance of Resistor Withstand Voltage Pollution Level for Bushing Connection 30kV 1 50Hz 14.3A 11.5A 1.5μF 125Ω 70/200kV Very Heavy Bushing

Parallel Capacitor General Specification of Parallel Capacitor we supplied for Shinkansen System is as follows; Ratings Parallel Capacitor Capacitor Unit: Tank Type 34.1kV x 2 2273kvar Reactor: Oil-Immersed Type Rated Voltage Number of Phase Rated Frequency Rated Harmonic Frequency Rated Current Rated Harmonic Current (Continuous) Installed Capacity Withstand Voltage Pollution level for bushing Connection 60kV 1 50Hz 150Hz 33.4A 16.7A 2000kvar 70/200kV Very Heavy Bushing

Static Var Compensator General Specification of Static Var Compensator we supplied for Shinkansen System is as follows; Item Static Var Compensator (SVC) Capacitor Unit: Tank Type Reactor: Oil-Immersed Type Equipment High-Impedance Transformer Thyristor (Light Direct Point Arc Type) Capacitor for Harmonic Filter Reactor for Harmonic Filter Ratings % Impedance: 80% 4kV 3000A 7~11 Series Connection Consist of 2FL, 3FL and PC For 2FL: L = 27% For 3FL and PC: L = 13%

Current Transformer General Specification of Current Transformer we supplied for Shinkansen System is as follows; Item Current Transformer Description Type Number of Phase Highest System Voltage Rated Frequency Applied Standard Test Voltages - Power Frequency - Full Wave Impulse Rated Primary Current Rated Secondary Current Burden and Accuracy - No. 1 Core - No. 2 Core FGCH-30 1 34.5kV 60Hz JEC-1201-1996 70kV 200kV 1500A 5A 40VA/1PS 40VA/1PS

Voltage Transformer General Specification of Voltage Transformer we supplied for Shinkansen System is as follows; Item Voltage Transformer Type Number of Phase Connection Highest System Voltage Rated Frequency Applied Standard Test Voltages - Power Frequency - Full Wave Impulse Rated Primary Voltage Rated Secondary Voltage Burden and Accuracy Description FTIE-60 (Dual Element Type) U or V Terminal to O Terminal 132kV (Induced voltage) 350kV 1 Phase to Earth 2 x 66kV 60Hz JEC-1201-1996 2 x 66kV 2 x 110V 2 x 200VA/1P O Terminal to Earth 22kV 60kV

Supply Record of Nissin Products for Overseas Railway System

Supply Record of Nissin Products for Overseas Railroad Projects Nissin s Quality Products have also been used for the railroad projects of overseas countries. Country South Korea Taiwan China Series Capacitor AC Filter Parallel Capacitor Shunt Reactor Voltage Transformer AC Filter Item High-Speed Railway System High-Speed Railway System High-Speed Railway System India CR-Device Capacitor Equipment 2 x 25kV AT Traction System of Bina-Katni section of Jabalpur in West Central Railway in 1991