RSA-MRZ Installation Instructions

Similar documents
RSA-MRZ Installation Instructions

Installation Instructions Shaper 1800 aircraft cable installation

Installation Instructions - Continua Suspended LED

Luminous HE 282/284 Direct ambient lighting. Neoray. Possibilities of Light

SeleCCTable LED Direct Mount Collection. RL Recessed Downlight. Direct Mount

SeleCCTable LED Direct Mount Collection

I. Pendant Mount Installation

INSTALLATION INSTRUCTIONS LED RETROFIT ASSEMBLY (LRA) Rev F

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

READ AND FOLLOW ALL SAFETY INSTRUCTIONS 1. DANGER RISK OF SHOCK DISCONNECT POWER BEFORE INSTALLATION

USB Panel-mount Extension Cable Installation Guide

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

Installation Instructions MX LED Enhanced Color Adjustable

Project. Comments. Prepared by

RSQ Collection Square LED downlight

INSTALLATION INSTRUCTION

LS1 SERIES IMPORTANT: READ ALL INSTRUCTIONS THOROUGHLY AND CAREFULLY PRIOR TO INSTALLATION OF LINEAR SERIES FIXTURES AND RETAIN FOR FUTURE REFERENCE.

Project. Comments. Prepared by

EZ Fingerprint Recognition Unit Installation Guide

INSTALLATION INSTRUCTIONS MOONRING 1 LP1/MR1

Project. Comments. Prepared by

HU20 Undercabinet lighting

HALO 2700K. 4000K nominal 493WBS06 494WB K Correlated Color Temperature. ML709840ICAT120D 900 Series Module, 80CRI / 4000K

INSTALLATION INSTRUCTIONS LIGHTPLANE 3.5. LP3.5 Suspended LED. A nd Avenue, Unit 1. CA P E W alwusa.

Lumination TM LED Luminaire RC/LRC/RX/LRX Series - New Construction Frame

MOONRING 1.5 MOONRING 3

Industrial LED luminaires Exit and Emergency

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Cruze Recessed LED luminaire

Project. Comments. Prepared by

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

Specification Grade Contemporary Wall Mount/Technical Installation Data

Project. Comments. Prepared by

INSTALLATION INSTRUCTION

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

Installation Instructions

Encounter Recessed LED luminaire

Diagnostic Test Kit Series P Series WARNING. for Polaris Robotic Cleaners

INSTALLATION INSTRUCTIONS SUPERPLANE 2.5. Suspended. A nd Avenue, Unit 1 Oakland, CA P E W alwusa.

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

Lumination TM LED Luminaires LAL Series - Continuous Run Option

Project. Comments. Prepared by

OSQ Series IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. LED Area Light TO INSTALL:

HBLEDLD524SEWUNV Hbledld524sewunvl850ed2u

Project. Comments. Prepared by

MAXLITE RKT LED Retrofit Kit

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

LUNERA VERTICAL E26 LED FLOODLIGHT LED Replacement for E26 Medium Base Floodlights Type B Ballast Bypassed

Captivate Illuminated Mirror Light

Avenue B. Grid Mount (Regress Trim Shown) Flush Lens. Drywall Flange (Regress Trim Shown) Narrow 3" slot LED with frosted satin lens.

ArcLine Recessed LED luminaire

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

MEDIA LED. Pendant Standard Mount Installation ou de montage WARNING:

2" LED SPECIFICATIONS ADJUSTABLE DOWNLIGHT & WALL WASH

FR Series Premium Commercial LED Luminaire

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

Project. Comments. Prepared by

High Bay Luminaire Series

Model: LUM-P1-40WCDS LUM-P7-50WCDS

INSTALLATION INSTRUCTIONS LED Canopy Retrofit Kit

VERSYS Architectural Recessed T5 Fluorescent

Installation Instructions Sero / Qub Pendant RETROFIT CONSTRUCTION- INACCESSIBLE CEILING Mounting Option GP

Cruze Recessed LED Luminaire

Project Name. 24 (609.6mm) 24 (609.6mm)

Project Name. 24 (609.6mm)

id + 4.5" Downlight mm Trim ChromaSure: Color consistency resulting in a 2-step MacAdam ellipse across the entire ID+ product line.

Compose GYPSUM Mud-In

Project Name ADEO AD22 EMERGENCY. G1-15/16 Grid G9-9/16 Grid GS - Screw Slot Grid FL - Flanged S - Surface Mount. Mounting pg. 3

ZIP LIGHT LED LUMINAIRE

2" LED SPECIFICATIONS ADJUSTABLE DOWNLIGHT & WALL WASH

Project Name. 23-3/4 (603.3mm)

Portfolio LDA4A 4L. Type. Catalog # Project. Date. Comments. Prepared by

Project Name. 23-5/8 (600.2mm)

ULTRA PERFORMANCE LED TUBE INSTALLATION INSTRUCTIONS

LED Recessed Troffer Retrofit Kit

id + 4.5" x 4.5" Downlight mm Trim ChromaSure: Color consistency resulting in a 2-step MacAdam ellipse across the entire ID+ product line.

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

INSTALLATION INSTRUCTIONS

LIGHTPLANE 1 RECESSED - LP1R

id + 6" x 6" Downlight mm Trim ChromaSure: Color consistency resulting in a 2-step MacAdam ellipse across the entire ID+ product line.

Installation Instructions BLTR and 2BLTR Relight Assembly

Albeo TM LED Luminaire Heavy Industrial High Bay Lighting (ABR1-Series)

RECESSED T-Bar & Drywall. Project. Type. Notes AULED 14 SO

Assembly of kick TM Utility Poles

NOVO LIGHTED MIRROR. Installation Instructions

LiFT LF12 1x2 Architectural Recessed

Project Name ADEO AD24 EMERGENCY. G1-15/16 Grid G9-9/16 Grid GS - Screw Slot Grid FL - Flanged S - Surface Mount. Mounting pg. 3

Output (nominal lumens) 700 lm, 1000 lm, 1300 lm, 2000 lm, 3000 lm, 4000 lm, 5000 lm. Color and color temperature

LED VaporProof Fixture

LED Retrofit Collection RL SeleCCTable Series

CONVERJ CJ24 2x4 Architectural Recessed

Project Name ADEO AD14. Adeo 1x4 (AD14) 1x4 Architectural Recessed. (76.2mm) EMERGENCY

Project. Comments. Prepared by

Strand Lighting Inc Darin Way, Cypress, CA 90630, USA Tel: Fax:

seem 2 led features dimensional data Narrow extruded aluminum 2.5" aperture recessed slot LED.

Luminaire PROFILE-SPOKE 15 UP 85 DN LED (PS1-D) Type. Notes. Performance Summary D OPTIONS 3S A 28 W B 34 W C 44 W D 57 W

4" LED SPECIFICATIONS LOW-PROFILE ADJUSTABLE DOWNLIGHT

INSTALLATION NOTES: nbeckon-26

4DR 4.5 Downlight Round

Transcription:

IL511001EN Brand Logo reversed black out of INS # RSA-MRZ Installation Instructions IMPORTANT: Read carefully before installing fixture. Retain for future reference. WARNING Risk of Electric Shock Disconnect power at fuse or circuit breaker before installing or servicing. WARNING Risk of Fire/Electric Shock. If not qualified, consult an electrician. WARNING Proper grounding is required to ensure personal safety. WARNING Risk of burn Use protective gear to ensure personal safety. This product must be installed in accordance with the applicable installation code by a certified electrician, familiar with the construction and operation of the product and hazard involved. To prevent possible wiring damage, do not expose wiring to edges of sheet metal or other sharp objects. Fixture in compliance with UL 1598 and UL 8750. MAX ambient temperature 25 C for all small fixtures. All electrical wire from junction box to fixture is to be provided by others. Ensure mounting surface s can support fixture assembly. Ensure all screws are torqued to proper settings. This product must be installed in accordance with applicable installation code and the hazards involved. Battery Section: This luminaire is provided with a factory installed emergency lighting pack and must be serviced by a person familiar operation of the product and the hazards involved. Danger Risk of shock. Disconnect all power and disable the battery pack power before servicing. LED Driver replacement requires re-connection of wires that may be energized. Description: The RSA-MRZ is a single and multi-head, recessed group of products with integral LED dedicated head / heads. Options include: flanged or mud-in trim, varied LED color temperatures, lumen packages, CRI, paint finishes, and optics are available. Each fixture head / heads tilt 45 deg with 365 deg rotation. Accessories available include: different shielding media, Chicago plenum, and remote mounted battery pack. The RSA-MRZ also has two available controls platforms, LumaWatt Pro and WaveLinx.

INSTALLATION Flanged Housing 1. Unpack RSA-MRZ fixture and ensure that all parts are included. (Figure 1) Figure 1. Accessory Plate (5) Wirenuts (2) S-Hooks Head Plate (2) 8-32 Screw (2) #1/4-20 Flange Nut Sheet Rock/ Grid Ceiling Tile Cut hole in ceiling or ceiling tile per cutout chart below: 1 Head Cut 1 Head (sensor) Cut 2 Head 2 Head (sensor) Cut Length 5.63 5.88 7.03 7.28 10.91 11.16 12.31 12.56 Flange Length 6.67 7.97 11.95 13.25 Width 5.82 6.07 5.82 6.07 5.82 6.07 5.82 6.07 Flange Width 6.64 6.64 6.64 6.64 3 Head Cut 3 Head (sensor) Cut 4 Head Cut 4 Head (sensor) Length 16.16 16.41 17.56 17.81 21.41 21.66 22.81 Flange Length 17.20 18.50 22.45 23.75 Width 5.82 6.07 5.82 6.07 5.82 6.07 5.82 Flange Width 6.64 6.64 6.64 6.64 2 EATON RSA-MRZ Installation Instructions IL511001EN

Mounting with ¼-20 Threaded Rod (All Thread) Options for threaded rod: Unistrut, Hanger Bars, Metal Bar Hanger Space ¼-20 threaded rod to line up with the knockouts on top of the fixture housing per distance(s) provided below. 1 Head 2 Head 3 Head 4 Head 5 Head 6 Head Distance Between Holes 3.53 8.78 14.03 19.28 24.53 29.78 Distance Holes off Center 1.338 0 0 0 0 0 Distance From End 1.063 1.063 1.063 1.063 1.063 1.063 Distance From End - Sensor End 2.463 2.463 2.463 2.463 2.463 2.463 2. Remove Fixture Head Plate and set the #8-32 screws aside to be used again. Disconnect low voltage Red and Blue wires at the WAGO connector junction located midway between the LED driver and fixture head mounting plate. (Figure 2) Figure 2. IL511001EN EATON RSA-MRZ Installation Instructions 3

3. Remove both ½ (0.5 ) knockouts from the top of the housing for threaded rod installation. (Figure 3) Figure 3. Remove knockouts for Threaded Rod 4. Power wires can be pulled through the power access plate. (Figure 4) Figure 4. Attach Whip to Accessory Plate 4 EATON RSA-MRZ Installation Instructions IL511001EN

5. Raise fixture housing into ceiling so the threaded rod feeds into the knockout holes. Make sure the flanges of the fixture housing are pulled tightly against the ceiling using the ¼-20 flange nuts on the threaded rod inside the housing. (Figure 5) Figure 5. #1/4-20 Threaded Rod Attached to Structure #1/4-20 Flange Nut 6. Use the S Hooks provided to attach through the rectangular slots on the non-power side of the housing. (Figure 6) Figure 6. Lift fixture into place and fasten with #1/4-20 Flange Nut Insert S-Hooks into rectangular slots IL511001EN EATON RSA-MRZ Installation Instructions 5

7. Lift the Fixture Head Plate up to the S Hooks and attach through the slots on the small flanges. (Figure 7) Figure 7. Hang Head Assembly From S-Hooks Connect Low Voltage wires Using Provided WAGO connectors 8. Reconnect the Red and Blue low voltage wires into the provided Wago connectors. Connect the hot, neutral, ground, purple (0-10V (+)), and gray (0-10V(-)) wires from fixture side to power feed side using wire nuts provided - minimize the lengths of wires being pushed back into the wire compartment, cut and strip wires to a shorter length if necessary. (Figure 8) Figure 8. Wiring Table: Black - Hot White - Neutral Green - Ground Purple - 0-10V (+) Gray - 0-10V (-) 6 EATON RSA-MRZ Installation Instructions IL511001EN

8a. Remove S Hooks while supporting Fixture Head Plate. Move the Fixture Head Plate into the housing, inserting the small flanges into the rectangular slots at a slight angle. Ensure wires do not get pinched along the edges of the plate and tilt up. Install the 8-32 screws. (Figure 8A) Figure 8A. Re-attach Head Plate using provided 8-32 thread forming screws Mud In/ Gypsum/ Sheet Rock Housing 9. Follow steps 1 through 4 from Flange Version above. Mounting shown (Figure 9, 9.a, 9.b) Figure 9. #1/4-20 Threaded Rod Attached to Structure Structure (by others #1/4-20 Flange Nut. Raise fixture housing into ceiling so the threaded rod feeds into the knockout holes. Make sure the flanges of the fixture housing are pulled tightly against the ceiling using the ¼-20 flange nuts on the threaded rod inside the housing. IL511001EN EATON RSA-MRZ Installation Instructions 7

9.a. Drill pilot holes through mud in flange along the side of the fixture as shown in figure 9.a. One screw every 4 inches is recommended on each side of the fixture. Figure 9.a 9.b. To finish - apply a generous amount of joint compound to fixture flange and feather at least 12 from fixture aperture. mud in up to the trim, around the edge of the fixture 8 EATON RSA-MRZ Installation Instructions IL511001EN

Replacing Optics 10. Using both thumbs, put pressure on the optic as you rotate it ¼ turn. (Figure 10) Figure 10. Snoot & Media Replacement 11. Remove O-Ring if using Shielding Media, otherwise Leave O-Ring to hold Snoot in place. (Figure 11) Figure 11. Head Assembly ML4 Optic Media (Optional) Snoot O-Ring (Remove only when using Shielding Media) Bezel Ring IL511001EN EATON RSA-MRZ Installation Instructions 9

Head Rotation Figure 12. 360 Rotation pull down head to rotate up to 45 Butterfly Bracket Attachment (Option) 8-32 SCREWS BUTTERFLY BRACKET 10 EATON RSA-MRZ Installation Instructions IL511001EN

Warranties and Limitation of Liability Please refer to www.eaton.com/lightingwarrantyterms for our terms and conditions. Garanties et limitation de responsabilité Veuillez consulter le site www.eaton.com/lightingwarrantyterms pour obtenir les conditions générales. Garantías y Limitación de Responsabilidad Visite www.eaton.com/lightingwarrantyterms para conocer nuestros términos y condiciones. Eaton 1121 Highway 74 South Peachtree City, GA 30269 P: 770-486-4800 www.eaton.com/lighting Canada Sales 5925 McLaughlin Road Mississauga, Ontario L5R 1B8 P: 905-501-3000 F: 905-501-3172 2018 Eaton All Rights Reserved Printed in USA Imprimé aux États-Unis Impreso en los EE. UU. Publication No. IL511001EN February 7, 2018 Eaton is a registered trademark. All trademarks are property of their respective owners. Eaton est une marque de commerce déposée. Toutes les autres marques de commerce sont la propriété de leur propriétaire respectif. Eaton es una marca comercial registrada. Todas las marcas comerciales son propiedad de sus respectivos propietarios. Product availability, specifications, and compliances are subject to change without notice La disponibilité du produit, les spécifications et les conformités peuvent être modifiées sans préavis La disponibilidad de productos, las especificaciones y los cumplimientos están sujetos a cambio sin previo aviso