Cooling Systems CC Series TT rail 20/30lpm

Similar documents
Off-line filter / cooler unit BKF

OFFLINE SERIES GLOBAL STANDARD COOLER. p f

Oil/Air Cooler Units. Standard series EL Type. Test procedure certified following EN 1048

Oil/air cooler BLK. Fluidcontrol

HEAT EXCHANGERS AIR/OIL TYPE LAC. - ATEX Version. Approved for applications where there may be an explosive environment above ground.

Circulation pumps BFP-ATEX-T3/T4

Off-Line Filter BNF. FluidControl

Off-line filter / cooler unit FGSL

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type

H-Cube System hydraulic oil conditioning cooler filter oil tank fan drive

Oil/air cooler BLK. Fluidcontrol

Coolers. OK Series. Air Cooled Oil Coolers Hydraulic Symbol OK 1-11 OKF Cooling Systems Catalog. Applications

Oil/Air Cooler Units. Compact application with AC Motor OK-ELC Type. Test procedure certified following EN 1048

Oil/Air Cooler Units. Mobile series with DC motor OK-ELD Type. Test procedure certified following EN 1048

A20 A20. Aluminium heat exchanger 398SAE004EN00

A-L O C COOLING SYSTEM OLAER COOLERS. Olaer A-LOC with integrated circulation pump for industrial hydraulic systems

Air Cooled Exchangers With Aluminium Cooling Elements

Oil/Air Cooler Units. Standard series OK-P type. Test procedure certified following EN

ELH Series - Hydraulic Fan Drive

A26. Aluminium heat exchanger A26

ELD Series - DC Motor Drive

Oil/Air Cooler Units. Mobile application and Hydraulic motor OK ELH Type. Test procedure certified following EN 1048

Oil/air cooler BLK ATEX-3GD

Fluid Handling: Panel Unit

ELD Series - DC Motor Drive

CONTINENTAL HYDRAULICS F03MSV-ND* FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK F03MSV-ND* - FLOW CONTROL VALVE, NON-COMPENSATED WITH CHECK

Air Cooled Exchangers With Aluminium Cooling Elements

OFFLINE SERIES GLOBAL STANDARD COOLER

Air Cooled Exchangers With Aluminium Cooling Elements DC ELECTRIC HEAT EXCHANGERS

Fluid Cooling Industrial COLW Series

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

Air Cooler Mobile OK-ELD 0-6 with DC motor

CTR Series. Turbine low meters with conditioned output and built-in loading valve. Up to. Output Options. Features. Hydraulic measurement and control

GLOBAL STANDARD COOLER

Fluid Cooling Brazed Plate BPSW Series

Cooling Systems Air Cooled / Liquid Cooled

Oil circulation lubrication systems. Product catalogue

GLOBAL STANDARD COOLER

Product Data Sheet HKK70VSD Revision 1 (Variant Code E)

NCF fans 50 Hz. Protection class IP 55

FILTERS. PUMP CARE - Suction filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

Formulas and units

AAVC. Accessories HIGH PRESSURE FANS HIGH PRESSURE WITH BACKWARD IMPELLER MANUFACTURING FEATURES:

A-L A C AIR OIL COOLER LUFT/ÖL-KÜHLER OLAER COOLERS. Olaer A-LAC with A.C. motors for industrial hydraulic systems

Electric cylinders CASM

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

Off-line Oil Filter Module Pi 8400

Air Cooler Mobile AC-LNH 8-14 with hydraulic motor

SINGLE STAGE TWO STAGES

HYDRAULIC MOTOR FAN DRIVEN PRODUCTS

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500

FILTERS. TANK CARE - Return filters TECHNICAL DATA ORDERING AND OPTIONS CHART CLOGGING INDICATORS. PRESSURE DROP ( p) CURVES CROSS FUNCTIONAL VIEW

Coolers. Air Cooled / Liquid Cooled

NCF fans 60Hz. Protection class IP 55

Spin-on Filters. Maxiflow Series. MAX 360 I/min - 10 bar. Low pressure filters

HYDROVAR IncReAseD flexibility AnD control with new generation

Filtrec elements are tested according to ISO 2941, ISO 2942 and ISO 23181

LKI LKI-HYD COOLING. Series. advanced quality customized designs made in europe. Oil/Air heat exchangers. Low noise level. High performance.

RETURN FILTERS. MATERIALS Head: Aluminium alloy Spin-on cartridge: Steel Bypass valve: Polyammide Seals: NBR Nitrile Indicator housing: Brass

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 202 CURVE SPECIFICATIONS 203 PERFORMANCE CURVE RIGHT PERFORMANCE CURVE RIGHT

PVE /117 ED VARIABLE DISPLACEMENT VANE PUMPS WITH DIRECT PRESSURE ADJUSTMENT SERIES 30 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS

MINI POWER PACKS WITH SUBMERSED MOTOR AND PUMP

Oil Filter Module Pi 8300

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEALS 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING TECHNICAL DATA 500

Graphic Symbol 100 L 140 G25. R -M V 4 4 G P E. Perm.* 2 Magnet. Differential Pressure P. Connection. R: BSP.F Thd. O: Not Fitted.

PRPM2-A. = 5.5 Nm (4.1 lb.-ft.) (qual. 8.8 Nm (6.5 lb.-ft.) for socket cap screws. = 50 Nm (36.9 lb.-ft.) for cartridges

Fluid Cooling Mobile AOHM / AOVHM Series

MODEL DIMENSIONS, mm WEIGHT OIL FILL L W H A B C D E kg l HK 450/ x ,9

2.4 HEAVY DUTY SERIES

Filter cooler unit with inline filter according to DIN Type ABUKG. Contents. Features. RE Edition: Replaces: 50126

IGP /117 ED INTERNAL GEAR PUMPS SERIES 10 OPERATING PRINCIPLE TECHNICAL SPECIFICATIONS HYDRAULIC SYMBOL

MODEL DIMENSIONS, mm WEIGHT OIL FILL L W H A B C D E kg l HK 450/ x ,9

MICROPUMP MAG-DRIVE GEAR PUMPS

Feed Pumps FZP / MFZP

Toll-free: 1 (844) MAGISTER

Calculation of external available Pressure. [m/s] 0,41 0,62 0,82 1,03 1,23 1,44 1,64 1,85 2,05 2,47 2,88 3,29 3,7

Industrial Diesel Generator Set KD1650-E 50 Hz - Emission Optimized EPA Tier 2 Compliant

Page - SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY 201 CURVE SPECIFICATIONS 202 PERFORMANCE CHART IDROGO PERFORMANCE CHART IDROGO

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

P.C. Priority Flow Control Valve Series J02D3. General Description

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Feed Pumps Direct Drive Series 1.1.

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 QUANTITY FOR MODEL 303 BEARINGS 303

Choose quality. FIMA 1

Oil / air cooler Series BLK-DC

Calculation of external available Pressure. 1. Criterion flow velocity (Ref. 20 C) Do not design units in conditions acc. to white areas!

By-pass: 1,7 bar (24.6 psi) setting N.B. Cartridge with integrated bypass valve and antidrainback membrane

Cooler Bellhousing KPV series

GLOBAL STANDARD COOLER

Technical specification agenitor 404b NG

Technical specification agenitor 408 NG

GLOBAL STANDARD COOLER

GLOBAL STANDARD COOLER

NCF 60 Hz. Protection class IP 55

ARW DRY COOLERS AXIAL FANS VERSION, MEDIUM AND HIGH CAPACITY. CAPACITY FROM 20 TO 775 kw ARW DRY COOLERS

PRESS G SERIES. Two Stage Light Oil Burners FIRING RATES

Oil/Air Cooler Units

VIKING SG SERIES SEALLESS MAG DRIVE PUMPS

Transcription:

CC Series 20/30lpm General Data And Details The oil / air coolers of our CC series are autonomous cooling systems with an integrated circulation pump. They work as a separate cooling unit or as a ilter cooling unit with an adequate ilter. The beneits of such circulation coolers are a constant cooling performance and a higher durability, because there are no pressure vibrations or peaks in the cooler unit. Conditions of use: Maximum oil temperature: 100 C, maximum air temperature: 50 C. Motors can be used up to an altitude of 1.500m. For other conditions of use please contact our engineers. Connection asa rail y x The asa rail system is the irst worldwide lexible mounting and connection system for air blast heat exchangers. It gives you the free choice of the connector direction through turnable ports. The rail slots in the radiator are the frame structure not only for connecting the ports, also for various possible mounting arrangements such as bypass systems, mounting of the cooler to aggregates, measurement devices and much more. Please contact us to discover the huge potential of this system for your application. x y Scale Drawing 40

CC Series 20/30 lpm TT 25 4-pol TT 25 6-pol TT 16 4-pol TT 16 6-pol TT 11 4-pol TT 11 6-pol TT 07 4-pol TT 07 6-pol compact group product overview LL 06 LL 04 LL 02 LL 01 Technical Data description order number oil low max. working pressure power current rotation air low noise level weight A C D K L M N [lpm] [bar] [kw] [A] [rpm] [kg/s] [db(a)] [kg] [mm] [mm] [mm] [mm] [mm] [mm] [mm] TT 07 rail CC 4-pol TT07RA47CC 30 10 0,75 1,81 1430 0,28 65 25,2 355 205 72 135 493 157 320 TT 11 rail CC 4-pol TT11RA47CC 30 10 0,75 1,81 1430 0,35 68 29,6 395 225 62 200 495 222 380 TT 16 rail CC 4-pol TT16RA47CC 30 10 0,75 1,81 1430 0,72 74 34,4 520 288 65 200 511 222 460 TT 25 rail CC 4-pol TT25RA47CC 30 7 0,75 1,81 1430 1,08 79 44,1 660 358 68 300 511 322 558 TT 07 rail CC 6-pol TT07RA66CC 20 9 0,37 1,22 925 0,19 57 26 355 205 72 135 493 157 320 TT 11 rail CC 6-pol TT11RA66CC 20 9 0,37 1,22 925 0,26 58 30,4 395 225 62 200 495 222 380 TT 16 rail CC 6-pol TT16RA66CC 20 8 0,37 1,22 925 0,52 65 35,2 520 288 65 200 511 222 460 TT 25 rail CC 6-pol TT25RA66CC 20 7 0,37 1,22 925 0,76 68 44,9 660 358 68 300 511 322 558 The maximum suction pressure is -0,4 bar. The viscosity range is <100cSt. Motor voltage: 230/400V @ 50Hz*. The protection level is IP55. Design radiator material radiator air in shape pump type pump material (housing) sheet metal material suitable luids Connection (BSP 1 ) Options ILLZATT53G25K gerotor powder coated steel mineral oil asa rail connector BSP 1 ¼ temperature switch 50 C, 60 C data* alternative voltages, frequencies, protection levels, etc on request HL 0929 HL 1247 HL 1508 electronic mounting connection 41 Cooler Systems Calculation

CC Series Series 40/60 lpm General Data And Details The oil / air coolers of our CC series are autonomous cooling systems with an integrated circulation pump. They work as a separate cooling unit or as a ilter cooling unit with an adequate ilter. The beneits of such circulation coolers are a constant cooling performance and a higher durability, because there are no pressure vibrations or peaks in the cooler unit. Conditions of use: Maximum oil temperature: 100 C, maximum air temperature: 50 C. Motors can be used up to an altitude of 1.500m. For other conditions of use please contact our engineers. Connection asa uc z The AUC (asa universal connector) system was the irst worldwide lexible connection system for air blast heat exchangers. It gives you the free choice of the connector direction through turnable ports in 3 directions. Also the dimension of the ports can be varied with optional types. Please contact us to discover the huge potential of this system for your application. x y Scale Drawing order number description A B C D E H1 H2 K L M N P [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] [mm] 0177AA49CC 0177 CC 4-pol 530 400 331 471 60 120 90 442 807 462 601 89 0257AA49CC 0257 CC 4-pol 635 410 341 568 60 110 110 542 817 562 701 93 0367AA49CC 0367 CC 4-pol 720 420 351 658 43 120 120 565 827 676 781 93 0467AA49CC 0467 CC 4-pol 785 420 361 725 40 125 125 738 837 758 856 94 0567AA49CC 0567 CC 4-pol 860 410 361 802 43 125 125 806 837 826 931 94 0177AA68CC 0177 CC 6-pol 530 400 331 471 60 120 90 442 807 462 601 89 0257AA68CC 0257 CC 6-pol 635 410 341 568 60 110 110 542 817 562 701 93 0367AA68CC 0367 CC 6-pol 720 420 351 658 43 120 120 565 827 676 781 93 0467AA68CC 0467 CC 6-pol 785 420 361 725 40 125 125 738 837 758 856 94 0567AA68CC 0567 CC 6-pol 860 410 361 802 43 125 125 806 837 826 931 94 42

CC Series Series 40/60 lpm group product overview LL 06 LL 04 LL 02 LL 01 Technical order number description oil low max. working pressure power current rotation air low noise level weight [lpm] [bar] [kw] [A] [rpm] [kg/s] [db(a)] [kg] 0177AA49CC 0177 CC 4-pol 60 10 1,5 3,35 1445 0,57 74 70,7 0257AA49CC 0257 CC 4-pol 60 10 1,5 3,35 1445 1,14 79 80,0 0367AA49CC 0367 CC 4-pol 60 8 1,5 3,35 1445 1,47 83 90,4 0467AA49CC 0467 CC 4-pol 60 8 1,5 3,35 1445 1,77 84 107,7 0567AA49CC 0567 CC 4-pol 60 8 1,5 3,35 1445 1,89 84 108,1 0177AA68CC 0177 CC 6-pol 40 9 0,75 1,95 955 0,39 62 66,7 0257AA68CC 0257 CC 6-pol 40 9 0,75 1,95 955 0,75 68 76,0 0367AA68CC 0367 CC 6-pol 40 8 0,75 1,95 955 0,94 73 86,4 0467AA68CC 0467 CC 6-pol 40 8 0,75 1,95 955 1,12 74 103,7 0567AA68CC 0567 CC 6-pol 40 8 0,75 1,95 955 1,21 74 104,1 The maximum suction pressure is 0,5 bar. The viscosity range is <240cSt. Motor voltage: 230/400V @ 50Hz*. The protection level is IP55. Design radiator material radiator air in shape pump type pump material (housing) sheet metal material suitable luids Connection (BSP 1 ) Options ILLZ32G32 (BSP1¼ ) ILLZ40G40 (BSP1½ ) screw pump powder coated steel mineral oil temperature switch 50 C, 60 C data* alternative voltages, frequencies, protection levels, etc on request compact HL 0929 HL 1247 HL 1508 electronic mounting connection 43 Cooler Systems Calculation

GT cooler The GT cooler is a ready mounted cooler package, consisting of a cooler, protection housing, mounted rail connectors and the ready wired electronic temperature control. All standard cooler sizes from TT 07 to 0177 are available as a GT cooler. Also the internal bypass version is easy to integrate with the same housing dimensions. The temperature control is a relay box in connection with a temperature sensor controlling the fan with the optimal fan speed and a soft start curve (see page 36). This reduces the noise level and increases the duration of the fan unit. The protection housing is a solid metal framework for rough mobile and special applications. The radiator side is protected by a metal grid and the whole cooler is mounted on the asa rubber vibration absorbers to reduce the mechanical stress. Speciic cooling performance Dimensions TT 16 GT TT 11 GT TT 07 GT h.p. TT 07 GT Technical Data order number description A B C D E F G H J K L weight optional internal bypass (30PSI) [mm] [mm] [mm] [mm] [mm] [mm] BSP [mm] [mm] [mm] [mm] [kg] cooler order no. TT07GD01GT TT 07 rail 12V GT 334 425 176 341 300 190 1 385 114 20 240 13,7 TT07GD01BPGT TT07GD02GT TT 07 rail 24V GT 334 425 176 341 300 190 1 385 114 20 240 13,7 TT07GD02BPGT TT07GD03GT TT 07 rail 12V GT h.p. 334 425 176 341 300 190 1 385 114 20 240 14,1 TT07GD03BPGT TT07GD04GT TT 07 rail 24V GT h.p. 334 425 176 341 300 190 1 385 114 20 240 14,1 TT07GD04BPGT TT11GD01GT TT 11 rail 12V GT 410 465 256 381 370 190 1 425 137 25 240 20,1 TT11GD01BPGT TT11GD02GT TT 11 rail 24V GT 410 465 256 381 370 190 1 425 137 25 240 20,1 TT11GD02BPGT TT16GD01GT TT 16 rail 12V GT 490 590 328 515 450 210 1 ¼ 550 143 25 260 30,6 TT16GD01BPGT TT16GD02GT TT 16 rail 24V GT 490 590 328 515 450 210 1 ¼ 550 143 25 260 30,6 TT16GD02BPGT Coniguration ready mounted and wired! 4x shock absorbers 1x temperature sensor 1x radiator 1x protection housing 1x fan unit 1x fan speed control unit Radiator material working temperature range: air in shape: working pressure: internal bypass 20 C to +80 C (oil temperature) 26 bar (static) alternative bypass settings (1bar / 5 bar) 44