B.M.P. DOORS LTD INDUSTRIAL RAPID DOORS

Similar documents
SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

JAMISON-B.M.P. INDUSTRIAL RAPID DOORS DynamicRoll PE Installation

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

CONTROL UNIT BIOS2. Manual for installation. Programmable Control board for wings gates.

GLM SERIES CONTROL Users Manual Rev:

JAMISON-B.M.P. INDUSTRIAL RAPID DOORS DynamicRoll Installation

Table of Contents

EC DECLARATION OF CONFORMITY

Installation Guide Rollerdor RD55 Econ Roller Garage Door

ECONOMISER SERIES E2T USER MANUAL

SKC400U SLIDING GATE OPENER OWNER S MANUAL

INSTRUCTION INVERTER COMPACT FOR SLIDING GATES /R0 10/11/2017

Te 803 Electronic Controller. Service, Operation & Technical Information Manual

SLIDING DOOR OPERATOR INSTRUCTION MANUAL

BARRY BARRIER GATE AUTOMATION

BELT Rapid Fold up Door

Owner s Manual. For SOLAR BOOM GATE. Model: CA-5000 SOLAR

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

Table of Contents. General Safety Preparation for Installation Parts List Optional Accessories Part List... 5

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

Z TECHNICAL INSTRUCTIONS

HIGH SPEED SLIDING GATE OPENER

INSTALLATION GUIDE Table of Contents

Installation Guide Rollerdor RD77 Econ Roller Garage Door

Vertical Vinyl Curtain Door

Gate & Door Controller with LCD and Intelligent Technology

D-FORCE1500PV GARAGE DOOR OPENER

Installation Guide Rollerdor RD55 Econ Roller Garage Door

Combined Ventilation Controller RVWS-T-224HA

SLIDE NEW CONTROL BOARD

Barrier Gate Manual. (DZX2.1 Control Board) (The third version) (Pictures for reference only, the product prevail in kind)

OMATION FOR SLIDING GATES LINESTAR INSTALLATION MANUAL

INSTALLATION M ANUAL

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

JBI Docupunch P33 Automatic Punch

TITANO 400V SLIDING GATE OPENER

Induction Power Supplies

BELT Rapid Fold up Door

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

VELA INDUSTRIAL INSTALLATION MANUAL

INSTALLATION MANUAL (cod )

CARE-C Light Curtain Installation Instructions.

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Wheel Products. WP8300 Operators Manual Rev: 910

USER MANUAL MPS 1-5KW SERIES

USER MANUAL PAR56 LED PAR CANS

AUTOMATIC CONTROL ROLLING DOOR OPENER

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

TECHNICAL DATA HYDRAULIC UNIT

User s Manual. Automatic Switch-Mode Battery Charger

DKG-114 MANUAL AND REMOTE START UNIT

Installation and Operation Back-UPS BX550CI-CN

Furnace Web Site FAQs. Pro Press 100 / Pro 100 / Pro 100 plus. Lift. Belt Noise

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

LIFTMASTER MAGIC BUTTON FS10 & LPK5 FAST SLIDER

PowerOhm Installation Manual for BM R Series Braking Modules

USERS GUIDE LO-21U LOCKOUT RELAY

Instruction Manual for the. E-SL 450 Series

PowerOhm Installation Manual for BM R Series Braking Modules

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL

Back-Up Sensor System

INSTRUCTION MANUAL_1219_ENGLISH SUPER ELF X3. Operating Instructions for DORNIER looms. Robustness Reliability Quality Productivity Versatility

SECEUROGLIDE ROLLER GARAGE DOORS, SECEUROSHIELD, SECEUROSCREEN & SECEUROVISION ROLLER SHUTTERS CONTENTS

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

TECHNICAL MANUAL AND ELECTRONICAL MODULE REGULATION VVVF-4 +

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

3D PRINTER USER MANUAL

L /2010 rev 5 MATRIX MATRIX-RE CP.BULL CP.BULL-RI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

EB Conveyor Maintenance Guide

YG101 SWING GATE OPENER OWNER S MANUAL

Model 1:8 Beast-ZTWSS120A 1:8 Beast-ZTWSS150A. PN#Model Cont.Current 120A 150A. Burst Current 760A 1080A

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Read Chapter 8 Servicing Machine in the Manual for general guidelines

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

5600 Series Power Operator Installation and Instruction Manual

Installing the gate post bracket with the cardboard arm template

USER MANUAL LUX-LD30W LED MOVING HEAD

1999 Mercury Cougar ACCESSORIES & EQUIPMENT' 'Passive Anti-Theft Systems - Cougar 1999 ACCESSORIES & EQUIPMENT

FM SECURITY AND REMOTE START SYSTEM

BOXER KING 5600/5600R TRUCK TYRE CHANGER

Sliding Gate Operator User's Manual

Installing the gate post bracket with the cardboard arm template

Delta Secure Spiroll 40 High Speed Security Door. Product Data Sheet 4 / 7

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

PowerOhm Installation Manual for LG ATV Series Braking Modules

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

IGLOO IGLOO EASY INSTRUCTION MANUAL

Technical Installation and Service Manual RollSeal 1733 County Road 68 Bremen, Alabama 35033

VECTRIX VX-2 SERVICE MANUAL. Version 1.0/May 2011 VECTRIX, LLC

INSTALLATION INSTRUCTIONS

Informational Distribution List:

Power Distribution System User s Manual. Model: PDS-100

Transcription:

B.M.P. DOORS LTD INDUSTRIAL RAPID DOORS Web site : www.bmpdoors.co.uk e-mail : info@bmpdoors.co.uk THERMICHROLL KOMBY ENGLISH INSTALLATION MANUAL IMPORTANT Read this manual carefully before installing the product The service of installation must be performed only by authorized personnel and in accordance with national wiring standards. After reading the entire manual, keep it for future reference.

INSTALLATION INSTRUCTIONS - Always use a power circuit specifically dedicated to the door. For wiring follow the manufacturer's instructions. - Tighten the screws of the electrical terminals to prevent loosening. - Make sure the power source has the required capacity. - Make sure the thickness of the cable conforms to what is stated in the specification of the power source. - Never install a differential circuit breaker in wet or damp areas. EQUIPMENT NEEDED 1 Tape measure 10 Level 2 Suitable lifting equipment (Genie, Forklift, Scissor Lift etc) 3 Screwdriver set 12 Tester 4 Steel drill 13 Hammer 11 Set of spanners (17 mm, 13 mm, 10 mm, 8 mm) 5 Hammer drill 14 Cordless screwdriver 6 Drill bits (Steel and concrete) 15 Grinder 7 Scissors 16 Silicone gun 8 Cable cutters 17 Pliers 9 Vices / Clamps 18 Set of Allen keys Elevator Forklift WITH INTENTION TO CONTINUOSLY IMPROVE ITS SERVICE, B.M.P. SRL. RESERVES THE RIGHT TO CHANGE THIS MANUAL AT ANY TIME, WITHOUT PRIOR NOTICE. IMAGES USED IN THIS MANUAL MAY BE SLIGHTLY DIFFERENT FROM YOUR PRODUCT AND ARE USED FOR ILLUSTRATIVE PURPOSES ONLY. 2 Installation manual

ASSEMBLY OF THE MECANICAL PART Door parts placed on the ground Attach the base plates to the wall. Fixing points. installation manual 3

ROLL-UP SHUTTER DOOR PLATE HOLDER ASSEMBLY Motor side Bearing side - 30 Bearing Side - 40 Fix the Dynamicroll support plates to the Roll-Up Shutter plate holders. 4 Installation manual

Rotate the motor using the chain, until it reaches the horizontal position. Insert the bearing on the opposite side of the shaft. Lift up and install the roll-up shutter. Assemble the components of the Dynamicroll door. installation manual 5

INFRARED PHOTOCELLS - BP100 NOTE: IN CASE OF OTHER PHOTOELECTRIC SENSORS INSTALLED NEARBY, YOU MAY EXPERIENCE DIFFICULTIES DUE UNCONTROLLED BEAM REFLECTIONS. 9 CONTROL BOARD 1 1 2 8 7 3 6 LEGEND 5 4 1 CONTROL CARD 6 MOTOR BRAKE TERMINAL FRAME (N 30-31) + FLASHING LIGHTS (N 29-30) 2 CONTROL CABINET 7 CONTROL CABINET LOCK 3 MOTOR TERMINALS (U-V-W) 8 START BUTTON 4 ISOLATOR 9 EMERGENCY BUTTON 5 EARTH TERMINAL 10 6 Installation manual

CONTROL CARD TERMINAL WITH LIMIT SWITCH Terminal N CONNECTION 1 +12V DC 100mA max. 2 0 V DC 100mA max. 3 Not used 4 5 SIGNAL - (option used 20.300) door open signal - (option used 40.300) door close signal 6 Not used 7 Photocell/safety sensor or safety edge N.C. 8 Opening command, radar, push button, pull cord etc N.O. 9 Not used 10 Not used 11 Start opening (standard) / closing option in use 000008 N.O. 12 Pedestrian start N.O. 13 Common inputs (+12Vdc) 14 Photocell N.C. 15 Common inputs (+12Vdc) 16 Stop N.C. 17 Slow down opening limit switch N.C. 18 Slow down closing limit switch N.C. 19 Opening limit switch N.C. 20 Closing limit switch N.C. 21 24 V ac power. Accessories 300mA max. 22 24 V ac power. Accessories 300mA max. 32-33 SIGNAL: open door signal Jumpers inputs N.C. not used Terminal N CONNECTION 23 Motor phase U 24 Motor phase V 25 Motor phase W 26 Power phase 230Vac 27 Neutral phase 230Vac 28 GROUNDING TERMINAL 29 Flashing light 230VDC 30 Flashing light/brake phase (COMMON) 31 Brake 105VDC installation manual 7

PRE-WIRING WITH LIMIT SWITCH 8 Installation manual

CONTROL CARD TERMINAL WITH ENCODER Terminal N CONNECTION 1 +12v DC 100mA max. encoder red cable 2 0 V DC 100mA max. encoder black cable 3 Not used 4 5 SIGNAL - (option used 20.300) door open signal - (option used 40.300) door close signal 6 Not used 7 Photocell/safety sensor or safety edge N.C. 8 Opening command, radar, push button, pull cord etc N.O. 9 Not used 10 Not used 11 Start opening (standard) / closing option in use 000008 N.O. 12 Pedestrian start N.O. 13 Common inputs (+12Vdc) 14 Photocell (no jumpers photocell with encoder) N.C. 15 Common inputs (+12Vdc) 16 Stop N.C. 17 Encoder green cable 18 Encoder yellow cable 19 Not used 20 Not used 21 24 V ac power. Accessories 300mA max. 22 24 V ac power. Accessories 300mA max. 32-33 SIGNAL (option used 20.300)closed door signal Jumpers inputs N.C. not used (no jumpers photocell with encoder) Terminal N CONNECTION 23 Motor phase U 24 Motor phase V 25 Motor phase W 26 Power phas e 230Vac 27 Neutral phase 230Vac 28 GROUNDING TERMINAL 29 Flashing lights 230VDC 30 Flashing lights/brake phase (COMMON) 31 Brake 105VDC installation manual 9

PRE-WIRING WITH ENCODER SCREEN ENCODER CABLE MUST BE CONNECTED TO TERMINAL NO. 2 (0Vdc) IN THE CARD 10 Installation manual

SIGNAL LED LD2 LD3 LD4 LD5 LD6 LD7 LD8 LD9 LD10 LD11 LD12 LD13 LED CLOSING LIMIT SWITCH LED OPENING LIMIT SWITCH LED SLOW DOWN CLOSING LIMIT SWITCH LED SLOW DOWN OPENING LIMIT SWITCH LED STOP LED ALIGNED PHOTOCELL LED PEDESTRIAN START LED START NOT USED NOT USED LED OPENING COMMAND LED PHOTOCELL/SAFETY SENSOR installation manual 11

12 CURTAIN INSERTION PROGR. BUTTON (P3) P1 OPEN P2 CLOSE CLOSING BUTTON (P1) OPEN ING BUTTON (P2) REVERSE 2 1 13 CURTAIN TENSIONING AND COLUMNS FIXING TELO MONTANTE MOLLA GUIDA MAX! 12 Installation manual

B 500 OPEN (green) LIMIT SWITCH ADJUSTING SCREWS SLOW DOWN OPENING (white) SLOW DOWN CLOSING (grey) CAMMES CLOSE (brown) COMMON (yellow) installation manual 13

LIMIT SWITCH SETTINGS SETTING OPEN GREEN CABLE (C1) LED OK 1) SETTING SLOW DOWN OPENING WHITE CABLE(C2) 300-400 mm LED OK 2) SETTING SLOW DOWN CLOSING GREY CABLE (C3) LED OK 100 mm PHOTOCELL 3) SETTING CLOSE BROWN CABLE (C4) LED OK 14 Installation manual

PLANNING WITH LIMIT SWITCH 1 2 LED OK DOOR CLOSE 3 4 HOLD FOR 10 SECONDS FAST FLASHING 5 6 PRESS START BUTTON OK DOOR OPEN 7 8 WAIT BREAK TIME PRESS START END installation manual 15

SETTING WITH ENCODER 1 2 PRESS DOOR CLOSE HOLD FOR 20 SECONDS 3 4 PRESS FAST FLASHING 5 6 PRESS OK CONFIRM THAT THE DOOR IS OPEN 7 8 PRESS WAIT BREAK TIME CONFIRM BREAK TIME 9 10 START CURTAIN STOPS AT PHOTOCELLS LEVEL 16 Installation manual

SETTING POSITION OPEN AND CLOSE WITH PROGRAMMER (only with encoder) ONLY AFTER PROGRAMMING THE ENCODER INSERT PROGRAMMER IN THE CONTROL CARD PLUG * +/- 10qc = ~ 1cm (*) OPEN RIDE VALUE INDICATIVE ONLY * +/- 10qc = ~ 1cm (*) CLOSE RIDE VALUE INDICATIVE ONLY installation manual 17

ATTENTION: CORRECT POSITION CLOSED DOOR YES NO BALLAST TUBE ATTENTION: CORRECT POSITION OPENED DOOR YES NO 18 Installation manual

SETTING HIGHEST SPEED (System parameters) MOTOR TYPE : 1,5 KW 50/60Hz PARAMETER FREQUENCY OPEN FREQUENCY CLOSE FREQUENCY SLOW DOWN OPEN FREQUENCY SLOW DOWN CLOSE FREQUENCY MAX SPEED HZ 70HZ 40HZ 30HZ 30HZ MOTOR TYPE : 0,75 KW 50Hz PARAMETER FREQUENCY OPEN FREQUENCY CLOSE FREQUENCY SLOW DOWN OPEN FREQUENCY SLOW DOWN CLOSE FREQUENCY MAX SPEED HZ 60HZ 30HZ 25HZ 25HZ PARAMETERS TO BE RESPECTED (System status) POWER MOTOR (Opening door) 1.5KW = MAX 8.5A (*) 0.75KW = MAX 4.5A (*) (*) IF THE VALUE EXCEEDS THAT SHOWN LOWER OPEN FREQUENCY. POWER BUS VOLTAGE (Opening door) MIN 280V(*) (*) IF VALUE DROPS BELOW THATSHOWN CHECK THE POWER SUPPLY CIRCUIT (CABLES SECTION 2.5MM FROM MAIN SOURCE, POWER SUPPLY VOLTAGE ETC.) installation manual 19

PLANNING PEDESTRIAN OPENING WITH ENCODER 1 2 PRESS DOOR CLOSE 3 4 PEDESTRIAN HEIGHT PRESS 5 PRESS 6 WITHIN 5 SECONDS SLOWLY FLASH CONFIRM PEDESTRIAN POSITION 7 8 PRESS CONFIRM BREAK TIME WAIT BREAK TIME END 20 Installation manual

PLANNING PEDESTRIAN OPENING WITH LIMIT SWITCH 1 2 PRESS DOOR CLOSE PRESS 10/15 SEC. 3 4 PRESS FAST FLASH 5 6 PEDESTRIAN HEIGHT PRESS CONFIRM PEDESTRIAN POSITION 7 8 PRESS CONFIRM BREAK TIME WAIT BREAK TIME END installation manual 21

CONNECTIONS WITHOUT ELECTRICAL PRE WIRING WIRING CABLE: Motor cable 3x1.5 screened cable (screen grounded) Limit switch cable (where installed) 5x0,5 Encoder cable (where installed) 4x0,5 screened cable (screen grounded) Break cable 2x1,00 screened cable Flashing light cable (screen grounded) 2x1,00 screened cable (screen grounded) Photocell receiver cable 3x0,5 Photocell transmitter cable 2x0,5 Motor safety switch cable 2x0.5 Button/anchors cable 2x0,5 Radar cable 4x0,5 Cable lines: - First tube line: motor, brake and flashing light cable ( High voltage 230V) - Second tube line: Photocell,limit switch, push buttons, radar etc. ( Low voltage 12-24V) BMP srl IS NOT RESPONSIBLE IF THE DOOR DOES NOT WORK WHEN THE REQUIREMENTS ARE NOT OBSERVED MOTOR TRIANGLE CONNECTION 22 Installation manual

DOOR ELECTRICAL SYSTEM MOTOR BOX WIRING installation manual 23

SENSOR NO TOUCH 24 Installation manual

LIMIT SWITCH CONNECTION C1 C2 C3 C4 F1 F2 F3 F4 FC OPENING LIMIT SWITCH SLOW DOWN OPENING LIMIT SWITCH SLOW DOWN CLOSING LIMIT SWITCH CLOSING LIMIT SWITCH CONNECTION N.C. CONNECTION N.C. CONNECTION N.C. CONNECTION N.C. CONNECTION COMMON - ADJUSTABLE AUTOMATIC CLOSURE DIP SWITCH (DS) To set this function put the dip Switch1 to ON - STEP BY STEP (*) Functioning mode set by the factory To set this function put the dip switch 1 to OFF ATTENTION!!! THIS FUNCTION DOES NOT PERFORM THE AUTOMATIC CLOSURE FUNCTIONING WITH NEGATIVE ENGINE BRAKE To set this function put the dip switch 2 to OFF FUNCTIONING WITH POSITIVE ENGINE BRAKE (*) To set this function put the dip switch 2 to ON (*) set it only if you have a door with COUNTERWEIGHT to open the door in case of power cut to the control board installation manual 25

SAFETY RESISTIVE EDGE RECEIVER TRANSMITTER RESISTIVE EDGE RESISTIVE EDGE VALUE BETWEEN 8.1 AND 8.4 kω (Tester on 20kΩ) ATTENTION ALWAYS CHECK THE RESISTIVITY BEFORE CONNECTING TRANSMITTER AND RECEIVER TRANSMITTER CONNECTION NO JUMPER PROG RESISTIVE EDGE INSIDE CURTAIN 26 Installation manual

RECEIVER CONNECTION CODE MEMORY A) Press PROG (transmitter) until you hear a beep B) Press PROG (in 5 sec max) (receiver) until you hear a beep C) Wait 10/15 sec D) LD 13 (resistive edge) ON TRANSMITTER MAXIMUM DISTANCE BETWEEN RECEIVER AND TRANSMITTER 8 METERS installation manual 27

MANUAL OPERATION RESET CONTROL CARD CLOSE BUTTON (P1) OPEN BUTTON (P2) - SWITCH OFF THE POWER TO THE CONTROL CARD - PRESS AND HOLD BUTTONS P1 & P2 - SWITCH THE POWER BACK ON TO THE CONTROL CARD WHILST STILL PRESSING THE BUTTONS P1 & P2 - KEEP PRESSED FOR 5-6 SECONDS - RESET COMPLETE, RESET ENCODER IF FITTED SAFETY GENERAL RULES Before any intervention the maintenance engineer must: o Cordon off area and affix the right signs in order to signal the maintenance works on the door o o PERIODICAL CHECKS AND MAINTENANCE Check that the electricity power is disconnected before you start the maintenance Check that they fully understand the maintenance required and have read and understand this manual o The maintenance man can t use the electrical fittings without a declaration of his proved experience. Don t allow unauthorized people to repair or maintenance the doors. Read the manual before maintaining the doors. During maintenance don t use heat sources that could start fires. During maintenance do not weld The presence of the maintenance staff around the door must be limited. The presence of other people around the door is necessary only to support the maintenance staff 28 Installation manual

GENERAL CLEANING AND MAINTENANCE The general maintenance operations can be carried out by the user. The maintenance and cleaning of the door is necessary to ensure the smooth operation and continued reliability in operation of the door. COMPONENT DESCRIPTION PERIODICITY Structure Verify that the structure is securely fixed to the wall in order to avoid incidents. Clean with soft cloth any dirt or dust build up ( use soap and water if required ) If there is ice on the structure immediately remove it Six-month Clean with soft cloth ( in dusty areas could be necessary to clean Photocell and more frequently the photocells: dust on photocells could cause radar malfunctioning of the photocells) Six-month Vision Window Curtain Clean the window with a soft cloth and if necessary with soap and water ( do not use any solvent that could damage the window) Check the condition of the belts and of the curtain. Clean the curtain with a soft cloth and if necessary with soap and water ( do not use any solvent that could damage the curtain) Six-month Six-month installation manual 29

CHECK, PLANNED INSPECTIONS AND MAINTENANCE Only the maintenance staff or authorized people could do checks, planned inspections and planned maintenance. These operations are necessary for the validity of the warranty INTERVENTION POINT Structure Electrical components Mechanical components Curtain DESCRIPTION - Check the condition of the fixing frames, and all fixings are tight that secure the frame to the fixing face - Check that there isn t any structural damage due to impact or collisions - Check the electrical connections in the control board and check that there is no moisture inside the cabinet. - Check the electrical connections in the junction box and check that there is no moisture present - Check the condition and operation of the safety components (photocells, safety edge and emergency button etc) - Check the condition and operation of the opening components (opening buttons, radars, loop detectors etc) - Check that all the electrical cables are in good condition. - Check the condition of the motor - Check the condition of the motor brake - Check the wear and tension of the drive chain from the motor to the barrel (where applicable) - Check the condition of the Gearbox: eg oil leaks, fixing to the motor, fixing of the structure. - Check the condition of the limit switch box: eg wear of the drive chain, wear and fixing of the cogs, the correct functioning of the cams and micro switches. - Check the tightness of all bolts for any part of the structure. - Check the condition of the main barrel in the heading - Check the condition and grease the bearings. - Check the condition of the anti wear washers on the columns - Check the condition and clean the guides ( on the Dynamic doors) - - Check the condition and wear of the curtain and in particular in the areas subject to rubbing. - Check that there aren t any tears on the curtain. - Check the condition and operation of the belts, lower and upper fixing plates and of the loop belts( for the rapid pack doors) - Check the condition of the curtain bars - Check the operation of the curtain rolling around the barrel squarely - Check the tensioning of the curtain, the condition and wear of the zips ( for the dynamic doors) PERIODICITY Six-month Six-month Six-month Six-month 30 Installation manual

PROBLEM SOLUTION 1 THE WARNING LIGHTS IN THE CONTROL BOARD DO NOT LIGHT UP 2 THE DOOR DOES NOT MOVE WITH P1 AND P2 BUTTON 1 CHECK POWER SUPPLY ( 230 V ) 1 CHECK FUSE 2 CHECK SETTING MOTOR WITH PROGRAMMER (SETTING PARAMETERS MOTOR TYPE kw) 2 RELEASE STOP BUTTON (LED 6 turned on) 2 CHECK MOTOR CONNECTION (triangle 230V three-phase, star 380V three-phase) 3 YOU CAN NOT COMPLETE THE SETTING OF THE CARD ( with encoder) 3 CHECK WITH PROGRAMMER PARAMETER OPTION IN USE 4300 FOR SINGLE PHOTOCELL 4380 FOR DOUBLE PHOTOCELL 3 RELEASE THE STOP BUTTON (LED 6 turned ON) 3 MOVE THE DOOR WITH BUTTON P1 AND P2 OF 40/ 50 cm AND LOCATE IT ON CLOSE POSITION ( this operation is useful to recognize the encoder ) 3 VERIFY THAT THE LED LD13 (radio safety edge or sensor in the upper case) IS ON 3 IF NOT, MAKE JUMPERS 7 /13 AND CONTROL THEN THE SECURITY COMPONENTS 3 INVERT THE ENCODER CABLE (yellow with green ) 3 FOR DOORS WITH UPPER PHOTOCELL CONTROL THAT LD 3 IS OFF WHEN THE DOOR IS CLOSE 4 YOU CAN NOT COMPLETE THE SETTING OF THE CARD 4 CONTROL THAT THE LIMIT SWITCH ARE CORRECTLY REGUALATED ( if slow down closing and closing limit switch are not pressed the card can not be set) (with limit switch ) 4 VERIFY THAT THE LED LD13 (radio safety edge or sensor in the upper case) IS ON 4 VERIFY THAT THE LED LD7 (safety photocell ) IS ON 4 RELEASE STOP BUTTON (LED 6 turned on) 5 YOU CAN NOT COMPLETE THE SETTING OF THE RESISTIVE EDGE 5 VERIFY THAT THE JUMPER ON THE TRANSMITTER J1 IS TAKEN OFF 5 RESET THE OLD CODES (close the jumper "MR" press the PROG button until you hear a beeps tight series, then remove the jumper) 5 VERIFY WITH THE TESTER THE CHARGE OF THE TRANSMITTER BATTERIES 5 VERIFY IF THE RESISTENCE (8.2 KΩ) FOR THE CABLES THAT COME OUT FROM THE EDGE CHANGES IF YOU PRESS THE EDGE if it does not change control that the resistive band is perfectly flat for all the length of the black profile or take out the gum and control the integrity. 5 VERIFY THE CONNECTIONS OF THE RECEIVER 6 THE PHOTOCELL DOES NOT WORK ( LD 7 OFF) (the door does not close ) 7 THE ANTI-JAMMING SENSOR DOES NOT WORK (sensor) (the sensor does not light up) 6 VERIFY THE ALIGNMENT 6 VERIFY THE CONNECTION OF THE BLACK RECEIVER CABLE( brown +12Vdc) (blue 0V dc ) ( black: signal that it arrives to the terminal 14 in the local plant) 6 VERIFY THE CONNECTION OF THE TRANSMITTER GREY CABLE ( brown +12Vdc) (blue 0V dc) ( ATTENTION! If you invert the brown and blue cables you will damage the sensors) 7 VERIFY THE CONNECTION ( brown +12Vdc) (blue + white 0V dc ) ( black: signal that it arrives to the terminal 7 in the local plant) installation manual 31

8 THE ANTI-JAMMING SENSOR DOES NOT WORK (sensor) (the door closes but the sensor does not work if I press it) 8 BRING THE SENSOR CLOSER TO THE CURTAIN 8 PUT THE SENSOR FRONTALLY TO THE TUBE AXIS 8 CONTROL THE CONNECTIONS ( brown +12Vdc) (blue 0V dc ) ( black connected to the cable 7 in the local plant) 9 THE DOOR STOPS AT THE PHOTOCELL LEVEL AND COMES BACK 9 REGULATE THE SLOWING DOWN LIMIT SWITCH: IT CLOSES 10 cm BEFORE THE PHOTOCELL ( the contact switch off the functioning ) 10 THE DOOR CLOSES ONLY 50 cm AND THEN COMES BACK 10 INCREASE THE INTERVENTION TIME OF THE ANTI-JAMMING PHOTOCELL USING THE PROGRAMMER (PARAMETER SETTING- ANTI- JAMMING PHOTOCELL READING) 10 LOWER THE ANTI-JAMMING PHOTOCELL SENSOR 11 LD1 REMAINS ON( IN THE TOP LEFT- HAND ) 11 VERIFIY THE FUSE 11 THE CARD IS DAMNAGED ( replace it) 12 THE DOOR DOES NOT CLOSE AUTOMATICALLY 12 VERIFY DIP 1 ( ON = automatic ) (OFF = manual ) 12 CONTROL THE CORRECT FUNCTIONING OF THE SAFETY COMPONENTS ( LD 7 - LD 13- LD 6 on) 13 THE DOOR WORKS BUT SOMETIMES IT GETS STUCK (in any position) 13 VERIFY THE CORRECT SETTING OF THE MOTOR WITH THE PROGRAMMER (PARAMETER SETTING TYPE OF MOTOR kw) 13 CONTROL THAT THE FLASHING LIGHTS WIRES OR THE MOTOR BRAKE WIRES ARE NOT IN THE SAME CABLE OF THE PHOTOCELL AND LIMIT SWITCH (interference problem) they must have their own cable and tube,the 230V must be separated from 12-24V 13 VERIFY WITH THE TESTER THAT THE CURRENT ISN T LOWER THAN 220V (control when the door s working) if the current is lower than 220V control the input 13 VERIFY WITH THE PROGRAMMER THAT THE BUS VOLTAGE IS NOT LOWER THAN 300V (SYSTEM CONDITION BUS VOLTAGE) (control when the door s working) if the voltage is lower than 300V control the input. 13 VERIFY WITH THE PRORAMMER THE MOTOR UPTAKE (SYSTEM CONDITION- MOTOR CURRENT with motor 0,75kW can t be higher than 7A;with motor 1,5 kw can t be higher than 9A, control when the door s working) if the door exceeds the threshold lower the opening HZ 14 THE PHOTOCELL DOES NOT WORK (the door closes but the photocell doesn t reverse the curtain) 14 CONTROL THAT IN THE VICINITY THERE ARE NOT ANY OTHER PHOTOCELLS THAT COULD CAUSE REFLECTION (try to darken the photocells) 14 CONTROL THAT WITH THE PHOTOCELL CABLES THERE ARE NOT ANY HIGH VOLTAGE CABLES (motor,motor brake, flashing lights, power line) (take to the control board separated cables in different pipes, separate the low voltage 12-24V from the high voltage 100V) 14 PUT THE MINUS OF THE RECEIVER (black cable, blue wire) ground 15 WITH OPEN DOOR (locked) THE CURTAIN SLOW DOWN 15 SET THE MOTOR BRAKE (remove the fan cover and close of a quarter turn of the dial brake adjustment, then make tests to reach the optimum) Spares or Technical support Information needed: - Personal information company (or owner of the door) - Door data (serial NO.) - Description of the problem - Eventually photos 32 Installation manual

- RUN OPTION with control card BMP1-VO1;BMP1-V03 end BMP2-V03 WARNING: logic board is set to the value of 200 (200 DEFAULT VALUE) by the factory. - Further values must to be added. VALUE TO INSERT ON RUN OPTION FUNCTION DESCRIPTION Enable ups batteries: function opens after fixed time 2 Enable ups batteries: function opens after start command 4 Start button: it closes but it doesn t open 8 Step cycle: closing the door to start stops mid 10 Pause time and queue time after transit individually considered with zero (0) break time only 20 Move the pedestrian start on internal radar: when you need pedestrian + ups 40 It disables current control brake before starting 100 It disables timeout control alarms on movements and other inconsistencies DEFAULT SETTING 200 Pedestrian start: it opens but doesn t close, it only clears pause time 400 It disables unplugged encoder alarm 800 Frost protection function: maneuver every 15 minutes 1.000 Frost protection function: running every 60 minutes 2.000 Frost protection function: adjustable time 3.000 You write the time in queue time after transit Encoder recognized automatically to the first movement in jog 4.000 DEFAULT SETTING It reverses relay outputs for signal door state Terminals 4-5 = door open 20.000 Terminals 32-33 = door closed It reverses relay outputs for signal door state Terminals 4-5 = door closed Terminals 32-33 = door open DEFAULT SETTING INTELOOK for BMP1-V03 end BMP2-V03(new models) Enable interlaced operation connect: Terminal no. 4 of card 1 with terminal no. 12 of the card 2 Terminal no. 5 of card 1 with terminal free of the card 2 80.000 Terminal no. 4 of card 2 with terminal no. 12 of the card 1 Terminal no. 5 of card 2 with terminal free of the card 1 Write in the lcd menu "bussola/c.remoto terminal n. The number of terminal used INTELOOK for BMP1-V01(running model) Enable interlaced operation connect: Terminal no. 4 of card 1 with terminal no. 12 of the card 2 80.000 Terminal no. 5 of card 1 with terminal no 13 of the card 2 Terminal no. 4 of card 2 with terminal no. 12 of the card 1 Terminal no. 5 of card 2 with terminal no. 13 of the card 1 It disables automatic alignment (after blackouts to return power) 100.000 With encoders and 1 single photocell If you inserted a undervoltage motor heating 200.000 (use only with installations in low temperature On pedestrian cycle, when the door is open, 400.000 It closes relay door state and disables automatic The radar does not open it only performs reversals in closing 1.000.000 installation manual 33