Amp Litewire Fiber Optic Coupled Ammeter

Similar documents
Operators Manual. Volt Litewire. Fiber Optic Coupled Voltmeter With Analog Output. SensorLink

True RMS Ampstik Slip-on Ammeters

Operators Manual. Qualstik PLUS. Live-Line Power Quality Survey Meter. SensorLink

Operators Manual. True RMS Voltstik. Radio Linked Multiple Reading Voltmeter. SensorLink

i400s Calibration Information Introduction

Copyright 2004 Alcatel. All rights reserved.

OWNER S MANUAL EVOLUTION 3500, 4500, 5500, & 8500 SERIES PUMPS

DMG100 Digital Micron Gauge Limited Warranty DMG100 DMG100 Digital Micron Gauge USA CANADA COPYRIGHT 2011 UEi

1,000 LB. CAPACITY TELESCOPIC TRANSMISSION JACK WITH AIR PUMP

DMG200. Digital Micron Gauge. 99 Washington Street Melrose, MA Phone Toll Free

Power InverterTM Watt. Continuous. User's Manual. WAGAN Corp. Limited Warranty Registration Form. Item no

OWNERS MANUAL IMPORTANT: READ OWNERS MANUAL CAREFULLY MODEL # SQUARE CAT XT OSCILLATING FLOOR MACHINE

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

INSTRUCTION MANUAL DM5B Fax: (503)

HIGH VOLTAGE DIGITAL AMMETER

SUBMERSIBLE MINI-PUMP

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

For technical questions and replacement parts, please call

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Easy-On Wireless Tail Lights User s Guide

HM860 FLOWMETER OPERATOR S MANUAL DO NOT USE OR OPERATE THIS EQUIPMENT UNTIL THIS MANUAL HAS BEEN READ AND THOROUGHLY UNDERSTOOD

instructions ZCM ZCM START International 4270 Airborn Dr. Addison, TX 75001, USA Tel Fax

i3000s/i2000 Flex AC Current Probe

Operating Manual Please Read Before Operating Unit

PUSH BUTTON KEY CABINET

SHEF30 Submersible Sump/ Effluent Pump

Replay Fabric Replacement Top

Installation and Operation Instructions Safety Director Arrow

SPECIFICATIONS GENERAL SAFETY RULES PERSONAL SAFETY. Save This Manual TOOL USE AND CARE WORK AREA

EQUIPMENT OWNERS MANUAL MATTHIESEN HEAVY DUTY SHAKER

COMPRESSED AIR LOADER MODEL: AL-1

Power. On Your Terms.

Patriot Portable Material Hoist 850/1000/2000. Operator s Manual

TOTALIZER-TRANSMITTER

EZ-R7 T-Plug. Universal 7-Pin Heavy Duty Plug For Vehicles equipped with 7-Way Trailer Connectors. Installation Instructions and Product Warranty

Infrared Thermocouple Probe

CRD610 Automatic Fitting Inserter

AC/DC LIPO CHARGER INSTRUCTION MANUAL

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications

Installation/Operating Instructions

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

CRD600 Automatic Fitting Inserter

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Read all instructions before installing and using. Installer: This manual must be delivered to the end user.

Owner s Manual. Instructions for Assembly, Testing, Operation, and Servicing. Trailer Kit: High speed upgrade kit used with Item# WARNING

AXD 530 MicroManometer

Installation/Operating Instructions

High-Dynamic-Range Power Sensors Models 2101 & 2103

10 Year Limited Warranty

Rev. 10/27/2015 CDL-2000, MANUAL

Hand Held Pull Tester Instruction Manual Order No

instruction ZCM 100 ZCM 200 START International 4270 Airborn Dr. Addison, TX 75001, USA Tel Fax

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Effective June 1, 2013 This guide supersedes all previous versions

OPERATING INSTRUCTIONS

Hydraulic Immediate Need Power Pack

Roller Door Operator

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

RESOURCE GUIDE. P r o d u c t M a n u a l. START International

Model RP310 Owner's Manual & Installation Instructions

Model 2008 I Battery Operated Irrigation Timer with 3/4 in. Anti-Siphon Valve

PAGE 1 OF 5 HEALTH, SAFETY & ENVIRONMENTAL MANUAL PROCEDURE: S360 Overhead Cranes & Lifts Procedure REV 4.0 8/14/2012

Item no Smart AC 200 USB. User s Manual

i n s t r u c t i o n m a n u a l

(450 m-925 m) ET/MDPE Tape Water Level Meter (with optional electric rewind)

& r"1aintef~ance. Your KENBAK-l computer is a quality instrument which is. should expect months or years of operation without significant

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

Installation Instructions for: Channel Thermocouple Amplifier

Calibration Manual. Detachable Jaw True-rms Clamp Meter

HDI inch Choke Position Indicator User s Manual Rev Indicator Gauge Linear Potentiometer

MODEL 660 AUTOMATIC FASTENING CENTER OPERATOR S MANUAL

HI HLPT SERIES LOAD POINT ASSEMBLIES OPERATION AND INSTALLATION MANUAL

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

E7000 AND E7500 INSTALLATION, OPERATION AND MAINTENANCE MANUAL FOR. 4 TO 20 ma ANALOG TRANSMITTERS

Automatic Butter Dispenser Instruction Manual Model #2395NS

TABLE OF CONTENTS GENERAL INFORMATION

HTR-202 INSTRUCTION MANUAL. Portable Digital Height Rod. Befour, Inc. 102 Progress Drive Saukville, WI 53080

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

High Velocity Series Air Curtains

SeekTech Inductive Clamp

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Remote Vehicle Control System. Keyless Entry and Convenience System

IV. PROOF OF PURCHASE: A warranty claim must be accompanied by proof of the date of purchase.

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

The Da-Lite Difference.

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

Compressor Clutch Replacement Procedure

Instruction Manual. Model HC1 Series Electrodless Conductivity Sensors

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Low Amp Probe EETA308A

HOOK-BASE INSTRUCTION MANUAL

Lincoln Hoist. Web Hoist Operating Manual. Lincoln Hoist

Battery Powered Hydraulic Pump; Kit PN [ ]

Snapshot LX5 USER MANUAL. OK on Dimmer Outdoor OK Sound Activated DMX512 Master/Slave 115V/230V Switch Replaceable Fuse User Serviceable Duty Cycle

INSTRUCTION MANUAL SURFACE RESISTIVITY METER SRM-110

RESPA -SD or Gideon HVAC Fresh Air Filtration System Installation Guidelines for John Deere 450J, 550J, 650J, 700J, 750J, 850J Crawlers

Transcription:

Operators Manual Amp Litewire Fiber Optic Coupled Ammeter SensorLink

Wide Jaw Amp Litewire Sensor Transmitter Model: 8-016 Amp Litewire Sensor Transmitter Model: 8-015 XT Amp Litewire Receiver Fiber Optic Cable Model: 7-026-1

Operators Manual Amp Litewire Fiber Optic Coupled Ammeter Available Stock Codes: 8-015 XT 50HZ 8-015 XT 60HZ 8-015 XT EURO 8-016 50HZ 8-016 60HZ 8-016 EURO 6-026 6-027 Table of Contents Page Theory of Operation 4 Safety Information 4 Specifications 5 Operating Instructions 6-8 Troubleshooting Guide 8 Handling Guidelines 9 Cleaning 10 Directional Properties 11 Battery Replacement 12 Amp LiteWire Diagram 13 Warranty 15 Quality Assurance Back Cover

Amp LiteWire Amp & Volt LiteWire Theory of Operation The Amp Litewire is a two piece, True RMS am me ter with a fiber op tic link be tween the high volt age amp sensor transmitter and the read out at ground po ten tial. The amp sen sor transmitter is mount ed on a hotstick (insulated pole) and slipped over a high volt age line. A fi ber optic cable con nects the amp sen sor transmitter to a receiver unit at ground po ten tial, which con tains the dig i tal read out and an an a log output. The in stru ment has no mov ing parts and does not re quire clamp ing onto the wire. The cases are wa ter re sis tant and will with stand high phys i cal impact. The analog output is the unique fea ture of this in stru ment. It is a re pro duc tion of the high volt age current waveform that will display up to the 50th har mon ic, but available as a 0-2 volt AC signal at ground. This allows the use of many so phis ti cat ed low volt age in stru ments, such as scopes, waveform ac qui si tion re cord ers, an a lyz ers, and other analysis in stru ments which would pre vi ous ly not be usable at high voltage. The fiber optic cable is physically rugged while providing the high speed data path required for digital waveform transmission from the sensor to the dis play unit. It also is the high voltage insulator be tween the two units. The Amp LItewire may be used with the Volt Litewire to maintain power systems and troubleshoot power problems.! SAFETY INFORMATION The Litewire is designed for use when attached to a suitable uni ver sal hotstick. All precautions appropriate for the line voltage should be taken. The sensor transmitter unit of the Litewire is not designed to be a high voltage insulator. The sensor transmitter should not bridge be tween conductors or between a conductor and ground. Be care ful not to allow the universal chuck adaptor or the metal parts of the hotstick to bridge between high voltage and ground or be tween two high voltage points. The fiber optic cable is a high voltage insulator and will isolate equipment and personnel in the same manner as a fiber glass hot stick. Visually inspect and clean the fiber with a non-abrasive hot stick wipe. The fiber should be replaced if the visual inspection reveals a flaw of a void or a hole in the finish of the fiber. The fiber should also be tested to determine its electrical insulation properties. If a fault is observed, the fiber should be replaced. Page 4

Specifications Model Number 8-015 XT 8-016 6-026 6-027 Sensor Opening Standard Wide Jaw Standard for Powermetrix Ultra Wide Jaw for Powermetrix Opening Width 2.5" 6.35 cm 3.86" 9.84 cm 3.86" 9.84 cm 6" 15.24 cm Weight 4.8 lbs 2.18 kg 6.0 lbs 2.73 kg 6.0 lbs 2.73 kg 6.8 lbs 3.084 kg Range of Operation Current 1-2000 A 1-2000 A 1-2000 A 1-2000 A Voltage Environment up to 150 kv up to 150 kv up to 150 kv up to 69 kv Accuracy ±1.5 % Resolution Amps 1-199.9 Amps 200-2000.1 A 1 A Frequency 50Hz Calibrated 60Hz Calibrated Analog Output Output Impedance Frequency Response 47 to 53 Hz 57 to 63 Hz One mv RMS per Amp on both the low range and the high range. Output connector is BNC. No DC offset voltage. 6000 ohms minimum 3000 Hz or to the 50th harmonic Fiber Optic Cable Standard Length Isolation 40 ft, 12.19 m 100 kv per Foot, 150 kv max Mechanical Ambient Temperature Display Housing Hotstick Mounting Battery -22 to +140 F, -30 to +60 C Lithium battery required for use below -4 F (-20 C) 3.5 Digit Display in Receiver Shock and Water resistant molded urethane Universal Chuck Adaptor (hot stick not included) 9 volt, one per Transmitter and Receiver Page 5

OPERATING INSTRUCTIONS The Litewire is controlled by the single push button switch located on the front panel of each unit, and is operated as follows: 1. Connecting the Fiber Optic link Work with one end at a time Uncover the dust cap on the male connector Uncover the dust cap on the female receiver, located on the sensor transmitter Line-up the male connector and insert into the female receiver Push and twist to lock into place Repeat the process on the opposite end of the fiber for the receiver unit 2. Attach units to the hot stick Attach the sensor transmitter to a universal hot stick (Insulated Pole) 3. Attach the Strain Relief Strap Wrap the velcro securely around the handle of the Transmitter as shown below Page 6

4. Press each switch once to turn on each unit of the Litewire The lower unit will activate the digital display when it is turned on. 5. Measurement Modes: Auto Range Mode (low/high range) If digits are showing in the digital display of the receiver as shown in figure 2.0, the LiteWire is in the normal Autor Ranging measurement mode..0 Figure 2.0 To use the Litewire in this mode, place the sensor transmitter so the current carrying wire is between the jaws into the sensor and observe the display on the receiver. The current in the wire will be continuously displayed. The digital display is auto ranging and the current may always be read directly from the receiver. No sample and hold mode is necessary since the readings can be observed at the operator s location. High Range Mode (exclusive high range) It may be necessary to have the unit in the high current range before a high current transient takes place. This prevents the Litewire from missing the transient while it is trying to switch ranges. Press the power on/off switch of the amp sensor transmitter. The unit will now be in the High Range mode. Figure 2.1 The resolution of the display will not display a decimal point, as in figure 2.1. 6. Hanging the Unit A detachable hook, ordered separately, is available to allow the amp sensor transmitter and its hotstick to hang temporarily from overhead wires. **The unit should never be left unattended while hanging. **The receiver unit should never be allowed to hang free. **The receiver unit should always be placed on a solid surface. 7. Output At the same time that the digital display is responding, an analog replica of the high voltage current waveform is available at the BNC connector. This signal may be read with any instrument that is capable of reading 0-2 volt AC and having an input impedance of 6000 ohms or greater. A portable oscilloscope, waveform recorder, or power analyzer may be used. You will need the following equipment to output to an analog device: (1) Amp Litewire: 8-015 XT Narrow Jaw or 8-016 Wide Jaw (1) Hanger Assembly: 7-017 Narrow Jaw or 7-016 Wide Jaw (1) 7-011-CABL (1) 7045 Hard Carrying Case 0 Page 7

8. Extending the Power Off time-out When the Amp Litewire sensor transmitter is powered on, the user has two minutes to place it on a conductor with greater than 7-10 Amps. To extend the time to 10 minutes the user needs to place the sensor transmitter in the High Range mode. If the Auto Range is desired, press the on/off button on the sensor transmitter an additional time. The user now has 10 mintues to place it on a conductor with greater than 7-10 Amps. 9. Powering the unit OFF Either unit may be manually turned off by holding its button down for 4-8 seconds. NOTE: The Litewire meters will automatically turn themselves off if there is no signal detected during a time out period. This feature is designed to save battery power. If an automatic time-out occurs, the units will have to be manually restarted. The amp sensor transmitter will turn off first and the receiver will always turn off one minute after losing communications with the amp sensor transmitter. Upon initial power-up of the units, if there is no signal detected within a one minute time period, the Amp Sensor/Transmitter unit will automatically turn itself off. If a signal of 7-10 amps or greater is detected within the one minute time period, the unit will continue to operate, or as long as the battery will operate the unit. TROUBLESHOOTING GUIDE Why are there dashes on the display? Dashes on the display indicate that the amp sensor transmitter is not communicating. Troubleshoot the communications: a. Make sure the amp sensor transmitter is powered on b. Make sure the battery in the amp sensor transmitter has 8.5VDC or greater c. Check the fiber end and ferule for dirt. See page nine and ten for the fiber optic cable handling and cleaning instructions d. Replace the Fiber Optic Cable Why is my unit not powering on? a. Verify that there are fresh 9V Batteries in each unit b. The units will automatically power off after one minute of inactivity in low range, or ten minutes in high range. Seven to 10 amps is required to keep the unit powered Page 8

Handling Guidelines Male Connector (End of Cable) Female Receiver (Mounted on In stru ment) Guide One: Never touch the ceramic ferrite end face of the male connector. Guide Two: Cover the fiber optic connector when not in use. Unprotected connector ends are most often damaged by impact, such as hitting the floor. The provided tethered boot will protect the connector s polished ferrule end from impact damage that might crack or chip the polished surface. Please contact Sensorlink Corporation for a replacement if the provided boot is lost or broken. Guide Three: The fiber end face and ferrule must be absolutely clean before it is inserted into a transmitter or receiver. Dust, lint, oil (from touching the fiber end face), or other foreign particles obscure the end face, compromising the integrity of the optical signal being sent over the fiber. From the optical signal s point-of-view, dirty connections are like dirty windows. Less light gets through a dirty window than a clean one. See page ten for cleaning instructions. Guide Four: As residue can build up in the boot, it important that the connector is thoroughly cleaned before mating, even if it was cleaned before the protection boot was installed. It is hard to conceive of the size of a fiber optic connector core. The core of your fiber is 62.5 microns, about half the size of a sheet of paper. Fiber optic connectors need to be clean and some debris cannot be seen by the naked eye. It is not unreasonable that users develop the discipline to clean the connectors everytime they are mated. See page ten for cleaning instructions. Page 9

Cleaning The fiber optic cable can be cleaned by wiping with a small amount of alcohol on a rag. The fiber optic cable should be cleaned and handled in the same manner as a fiberglass hotstick. It is critically important for fiber optic connectors to be free of dust and dirt to maintain optimum performance. Cleaning should be done as often as possible. Especially if used in a dusty and or dirty environment. A simple and effective way to guarantee cleanliness is to clean the ends of your fiber optic cables each time they are disconnected. Connector Body Ceramic Ferrite Dust Cap Recommended Equipment: Kimwipes or any lens-grade, lint-free tissue. The type sold for eyeglasses work quite well. Denatured alcohol. Note: Use only industrial grade 99% pure isopropyl alcohol. Commercially available isopropyl alcohol is for medicinal use and is diluted with water and a light mineral oil. Industrial grade isopropyl alcohol should be used exclusively. Canned dry air. (Optional) Microscope Recommended Process: 1. Fold the tissue twice so it is four layers thick. 2. Saturate the tissue with alcohol. 3. Clean the sides of the connector ferrule. Place the connector ferrule in the tissue. Apply pressure to the sides of the ferrule. Rotate the ferrule several times to remove all contamination from ferrule sides. 4. Move to a clean, saturated part of the tissue that is four layers thick. Put the tissue against the end of the connector ferrule. Put your fingernail against the tissue so that it is directly over the ferrule. Scrape the end of the connector until it squeaks; it will sound like a crystal glass that has been rubbed when it is wet. 5. (Optional) Use the microscope to verify the quality of the cleaning. If it isn t completely clean, repeat the steps with a clean tissue. Repeat until you have a cleaning technique that yields good, reproducible results. 6. Mate the connector immediately if possible. If not possible, be sure to replace protective boot. 7. 7. Air can be used to remove lint or loose dust from the port of a transmitter or receiver to be mated with the connector. Never insert any liquid into the ports. Page 10

Directional Properties The Amp sensor on the Litewire is direction sensitive. In order to insure proper phase relationship when comparing to a voltage reference, place the Amp Litewire so the face of the instrument is facing the load. Another indication of improper orientation would be indicated by the phase angle indication on the Bar Graph Screen of the Fluke 43. The proper phase angle should be 0 to ±90º when measuring the fundamental. When the sensor is positioned in an improper orientation the phase angle will read ±91º to ±180º. Source Load Current Flow Page 11

BATTERY LIFE & REPLACEMENT The Litewire is powered by two 9V batteries, one in the upper unit and one in the lower unit. When the word LOBAT appears on the display, the battery in the upper unit should be replaced. When the word LOBAT flashes on the display, the battery in the lower unit should be replaced. The unit will continue to operate for an hour or more after one of these indicators appears. To replace the battery, remove the four screws on the battery cover at the rear of the unit. Carefully insert a screwdriver blade in the notch and pry the cover out, being careful not to damage the cover seal. Pull the battery out of the compartment and separate the battery from the battery connector. To avoid breaking the battery leads do not pull on the battery only. Install a fresh battery and reinsert the battery in its compartment. Do not pinch the wires between the battery and compartment; put wires in slot above the battery. Reinstall the cover by gently pressing it into place while pulling out on the edges of the compartment, and reinstall the four cover screws. Take care to avoid overtightening the screws. Always reuse the screws provided and do not damage or lose the o-ring seal on each screw. Page 12

Amp Litewire Diagram 4 1 6 3 9 7 8 2 5 1 1. Female Fiber Optic Ends 2. ON/OFF Switch 3. Universal Chuck Adaptor 4. Amp Sensor/Transmitter 5. Digital Display 6. Fiber Optic Cable 7. Male Fiber Optic Ends 8. BNC Outputs 9. Strain Relief with Velcro Page 13

Page 14

SensorLink Corporation Warranty SensorLink warrants each instrument it man u fac tures to be free from defects in materials and workmanship under normal use and service for the period of one year after date of shipment. Within this period, SensorLink agrees to repair or replace, at SensorLink s option, any instrument that fails to perform as specified. This Warranty shall not apply to any instrument that has been: 1 Repaired, worked on, or altered, including removal of the front panel, by persons un au tho rized by SensorLink in such a manner as to injure, in SensorLink s sole judgment, the per for mance, sta bil i ty, or reliability of the instrument; 2 Sub ject ed to misuse, negligence, or accident; or 3 Connected, installed, adjusted, or used otherwise than in ac cor dance with the instructions furnished by SensorLink. This Warranty is in lieu of any other warranty, expressed or implied. SensorLink reserves the right to make any changes in the design or construction of its in stru ments at any time, without incurring any obligation to make any change what ev er in units previously de liv ered. If a failure occurs, contact the manufacturer for a Return Au tho ri za tion and instructions for return shipment. This warranty con sti tutes the full understanding of the man u fac tur er and buyer, and no terms, conditions, understanding, or agree ment purporting to modify or vary the terms hereof shall be binding unless here af ter made in writing and signed by an authorized official of SensorLink. Page 15

Quality Assurance Certification Fiber Optic Coupled Ammeter Model 8-015 XT and 8-016 SensorLink certifies that its calibration measurements are traceable to the National Institute of Standards and Technology (NIST), to the extent allowed by the Institute's calibration facility, and to the calibration facilities of other International Standards Organization members. This document certifies the following Model 8-015 XT/8-016 was tested at the SensorLink Corporation High Voltage Laboratory, Ferndale, WA, USA to the appropriate standard and comply with the requirements of that standard. Serial Numbers Model Numbers I hereby certify that the Model 8-015 XT/8-016 Amp Litewire has passed all tests defined in the SensorLink Corporation standard. I also certify that I have reviewed the standard and test procedure and that they are sufficient in determining compliance with the standard. Signed: Date: Form No: SALE-Manual Template AMP LW-014 REV: V01 Date: 11/19/2013 Manual Stock Code No: DOPM-801-500 SensorLink Corporation 1360 Stonegate Way Ferndale, WA 98248 USA phone: 360/595.1000 fax: 360/595.1001 www.sensorlink.com