LEM~flex RR3020 AC Current Probe Operating Instructions Mode d emploi Bedienungshandbuch Manuale Operativo Manual de uso

Similar documents
1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

i3000s/i2000 Flex AC Current Probe

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

CP GermanCp 41_CP C. Operating Instructions. CP 30 CP 330 CP 1100 AC/DC current probe /7.10

Low Amp Probe EETA308A

Flex current clamps A 1179 A 1257 A 1395 User Manual Version 1.6; Code No

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

Operator s Manual TC-253A. Temperature Converter

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

i400s Calibration Information Introduction

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

PSU EN54-4 Power Supplies

Barnant Company (Type J) (Type K) (Type T)

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

K100 K110 AEMC INSTRUMENTS ENGLISH. User Manual. n DC/AC MICROPROBE. Model K mv/ma OFF. DC/AC MicroProbe

Thermistor Thermometer MODEL NO

METEOROLOGICAL INSTRUMENTS

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

MIT300 Series Insulation and Continuity Testers

KTD30 Digital Insulation and Continuity Tester. User Manual. kewtechcorp.com

P U L S A R point 210

Water Level Meter + Temperature

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

RE-PR1-F 1-Phase Din-Rail Mount 1.5, 3 & 6kW

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

Thermocouple Thermometer Models

KMP Insulation-Continuity Tester. Users Manual

TACH-10 Contact / Non-Contact Tachometer

This instrument is manufactured in the United Kingdom. The company reserves the right to change the specification or design without prior notice.

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Table of Contents Title Page No.

KTD30 Digital Insulation and Continuity Tester

INSTRUCTIONS FOR USE

Operators Manual. Qualstik PLUS. Live-Line Power Quality Survey Meter. SensorLink

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Weatherproof Tubular Slip Ring Assembly

ILED Aquarius Illuminated Windsock. User Manual

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Calibration Manual. Detachable Jaw True-rms Clamp Meter

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

365 Detachable Jaw True-rms Clamp Meter

INSP-3 Wiring Inspection Tester

Rental Industry Safety Tester Safe Check 5s

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

1.Safe testing IMPORTANT:

ROGOWSKI LEAK METER MODEL RLM-1

SINGLE STICK DIGITAL VOLTMETER

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

Switching DC Power Supply

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Declaration of Conformity

BM kv Digital Insulation Tester USER MANUAL

HIGH VOLTAGE DIGITAL AMMETER

DKG-114 MANUAL AND REMOTE START UNIT

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

Go to to register your product and find more information.

DOUBLE VISION DUAL DISPLAY PHASING VOLTMETER

Contents. Introduction Inspection Notes on Safety Precautions. Chapter 1 Overview Product Overview Names of Parts 2

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

DET3TA, DET3TC, DET3TD and DET4TD Earth Ground Electrode Testers USER MANUAL

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

KSZ 10B Current Probe Calibrator. Instruction Manual

Instruction Manual IVT-10 / IVT-20 Voltage Tester

362 Clamp Meter. Users Manual

Web Volume Control Model WV220

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

IDEAL INDUSTRIES INC. TECHNICAL MANUAL - SUPPLEMENT MODEL

APEX DRIVE USER GUIDE ADDENDUM: LVD INSTALLATION INSTRUCTIONS

Spy pocket Jeepmeter ope rati ng instructions

ETL Water Level Meter

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Indoor Air Quality Meter

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

373 Clamp Meter. Users Manual

Model 1900, 1901, 1902 Switching DC Power Supply

High Frequency SineWave Guardian TM

6 OFF ROAD LIGHT BAR

Warner Instruments 1125 Dixwell Avenue, Hamden, CT (800) / (203) (203) fax

Multi-Mover Charger for model L25

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

User Manual. FRESH AERO EasyBrow Plug-In Battery Operated LED Eyebrow Light For Most Aircraft. Where Imagination Meets Innovation

Dawson DDM190D. Digital Multimeter User s Manual

Auto-Off & Power Hold Function

BK BK J93 MA BK MA BK MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

BMRX Series ROTARY LEVEL CONTROL

PHASERS. Operating and Instruction Manual. a n d A C C E S S O R I E S

Transcription:

LEM~flex RR3020 AC Current Probe Operating Instructions Mode d emploi Bedienungshandbuch Manuale Operativo Manual de uso

Table of Contents Order Reference Order No. LEM~flex Type RR3020 AC Current Probe... 60.31.71.000.0 Batteries are included. Thank you for buying this product For safety reasons and optimum use of this instrument read through the operating instructions very carefully. Table of Contents 1 SAFETY... 1 2 INTRODUCTION... 2 3 SPECIFICATIONS... 3 4 OPERATION... 6 4.1 Battery installation... 6 4.2 Measuring current with the RR3020... 6 4.3 Operation... 8 4.4 Battery status... 8 5 MAINTENANCE... 8 6 WARRANTY... 9 7 OTHER PRODUCTS... 9 Issue 1 07/11/00.

Safety 1 SAFETY The following symbols appear on the products: Attention! Refer to Manual Double/Reinforced Insulation Read all instructions completely before using this product. To avoid electric shock: Use caution during installation and use of this product; high voltages and currents may be present in circuit under test. This product must be used only by qualified personnel practising applicable safety precautions. Wear protective clothing and gloves as required. Do not install this product on live conductors. Always de energise circuit under test before installing flexible measuring head. Always inspect the electronics unit, connecting cable, and flexible measuring head for damage before using this product. Do not use product if damaged. Always connect electronics unit to display device before installing the flexible measuring head. Never change batteries while measurement head is installed on conductor. 1

Introduction 2 INTRODUCTION The LEM~flex RR3020 is an AC current probe utilising Rogowski principle. The LEM flex RR3020 can be used to measure AC current up to 3000 A when used with a DMM, oscilloscope, or other recording instruments. The flexible measuring head allows current measurements on conductors that are hard to reach or inaccessible using typical clamp-on current probes. The LEM~flex RR3020 provides a low-voltage, (3 V AC), output proportional to the current being measured. Three selectable ranges provide direct readings for 30 A, 300 A, and 3000 A full scale. 2

Specifications 8 9 2 5 1 6 7 3 4 Fig 1 1. Measuring Head 2. Measuring Head Coupling 3. Head Output cable 4. Enclosure 5. Power On / Range Selector 6. Battery Low Indicator 7. Power On Indicator 8. 4mm Safety Plug (Common) 9. 4mm Safety Plug (V Output) 3

Specifications 3 SPECIFICATIONS Measuring ranges Output sensitivity Accuracy (at 25ºC) Frequency range Phase error Linearity Position sensitivity External field Minimum load Noise 30A / 300A / 3000A AC, switch selectable 100mV / 10mV / 1mV per A (AC coupled) ± 1% of range (45-65Hz) 10Hz to 20kHz (-1dB) <± 1 (45-65Hz), ± 10 (at 20kHz) ± 0.2% of reading from 10%... 100% of range ± 2% of range with cable > 25mm (1") from the coupling ± 1% of range with cable >200mm (8") from the head 100kΩ for specified accuracy 8mV rms (0.3% of range) in 30A range 2mV rms (0.1% of range) in 300A and 3000A ranges Gain variation ± 0.08% / C Operating temp. Storage temp. Power supply Battery life Low battery Enclosure Material 0 C to 70 C (32 F to 158 F) electronics -20 C to +70 C (-4 F to 158 F) Two AA MN 1500 LR6 alkaline batteries or equivalent 200 hours typical Indicated by a red LED IP5X flame retardant UL94-VO rated Valox 357 X 4

Specifications Output con. Weight 4mm safety plugs 0.19 kg (0.4 lb) Safety BS EN 61010-1: 1993, 600V CAT III Pol. Deg 2 Test voltage: 5550 V AC for 1 minute, Double insulation EMC EN 61326 : 1998 Dimensions 116 (l) x 68.5 (w) x 30 (d) mm 4.57 x 2.71 x 1.18 inches Measuring Head Cable length Cable dia. Bend radius Output cable Coupling dia. Material Operating temp Storage temp. Weight 610mm (24 inches), double insulated 14.3mm (0.562 inches) 38.1mm (1.5 inches) 2m long (78.7inches) 22.2mm (0.875 inches) TPE rubber, Polypropylene, UL94-VO rated -20 C to +90 C (-4 F to 194 F) -40 C to +105 C (-40 F to 221 F) 0.18kg (0.4 Ib.) Safety BS EN 61010-1 : 1993, 600V CAT III Pol. Deg 2 5

Operation 4 OPERATION 4.1 BATTERY INSTALLATION Never replace batteries with flexible measuring head installed on conductor to be tested or output connected to a display device. Never operate the unit without the battery cover fitted. The LEM~flex RR3020 requires two AA MN1500 LR6 alkaline batteries for operation. The battery compartment is accessed from the rear of the electronics enclosure. The batteries must be replaced when the LED is lit continuously or fails to light up. Ensure that the LEM flex current probe is away from any current carrying conductor and the output is disconnected from any other equipment. Using a coin or a similar tool turn the battery lock ¼ turn until the dot aligns with the unlock symbol. The battery cover can now be removed. Install the batteries ensuring that correct polarity is observed. Replace the battery cover and turn the battery lock until the dot aligns with the lock symbol. 4.2 MEASURING CURRENT WITH THE LEM~flex RR3020 Read safety section of instructions before operating this product Ensure conductor to be tested is de energised. Connect the output of the electronics to the VOLTS input of the DMM or other data recording device. 6

Operation The flexible current probe is not for use on conductors with a potential of over 600V. Wrap the flexible measuring head around the conductor to be tested, close coupling. Energise circuit under test. For most accurate measurement, centre the flexible head around conductor. Locate coupling away from nearby conductors. Do not use the flexible current probe to measure bare conductors unless wearing protective clothing suitable for high voltage work. Always use appropriate equipment for personal protection. 7

Maintainance 4.3 OPERATION Select the AC VOLTS range on the DMM (or other device). To activate unit, move switch from the off position to the required measuring range. If the value of current being measured is unknown, first select the 3000A range and then reduce accordingly. 4.4 BATTERY STATUS Battery status is indicated by an LED on the front of the probe. This LED will flash one time when the unit is activated. The length of time the LED is lit will increase as battery life decreases. Momentary lighting of LED indicates batteries are good. Continuous lighting of LED indicates low battery, replace batteries soon. No lighting of LED indicates batteries are dead, replace immediately. 5 MAINTENANCE Do not use the LEM~flex RR3020 if damaged. Always inspect the electronics unit, connecting cable, and flexible measuring head for damage before use. To avoid electric shock, keep the LEM~flex RR3020 clean and free of surface contamination. Use Isopropyl Alcohol to clean the electronics unit and measuring head. Make sure the flexible measuring head, connecting cable, and electronics enclosure are dry before further use. 8

Warranty & Other Products 6 WARRANTY Your LEM~flex is guaranteed for one year from the date of purchase against defective material or workmanship. If the LEM~flex fails during the warranty period, we shall at our discretion, repair or replace it with a new or reconditioned unit provided we are satisfied that the failure is due to defective material or workmanship. To make a claim under warranty, the probe should be returned to us, postage prepaid, with a description of the defect. The use of a battery, other than that specified invalidates this warranty. Goods alleged by the buyer to be defective shall not form the subject of any claim for injury, loss, damage, or any expense howsoever incurred whether arising directly or indirectly from such alleged defects other than death or personal injury resulting from the seller s negligence. No condition is made or to be implied nor is any warranty given or to be implied as to the life or wear of goods supplied or that they will be suitable for any particular purpose or for use under specific conditions, notwithstanding that such purpose or conditions may be made known to the seller. 7 OTHER PRODUCTS LEM Probes offer a wide range of current probes covering AC and DC currents from 5mA to 2000A. LEM produces a range of instruments and devices for measuring electrical parameters. More information can be found in the LEM web site : www.lem.com LEM policy is one of continuous product improvement and the Company reserves the right to revise the above specifications without notice. 9

DECLARATION OF CONFORMITY Equipment Name/Type Number: RR3020 Manufacturer: Address: LEM HEME LIMITED 1 Penketh Place, West Pimbo, Skelmersdale, Lancashire, WN8 9QX. United Kingdom. European Standards: - EMC Safety BS EN 61326 : 1998 Electrical equipment for measurement, control and laboratory use EMC requirements BS EN 61010-1 : 1993. Safety requirements for electrical equipment for measurement, control and laboratory use Part 1. General Requirements Description of Equipment: Flexible AC current probe I certify that the apparatus identified above conforms to the requirements of Council Directives: - Signed: (1) Electromagnetic Compatibility Directive 89/336/EEC (2) Low Voltage Directive 73/23/EEC (3) CE Marking Directive 93/68/EEC Date: 18.08.00 Having made this declaration the CE mark may be affixed to the product, its packaging, instruction manual or guarantee certificate.

LEM Probes 1 Penketh Place, West Pimbo Skelmersdale, Lancashire WN8 9QX Tel. +44 1695 72 05 35 Fax +44 1695 502 79 e-mail: probe@lem.com www.lem.com