CRICKET Alphasonic Level Transmitter Model LA12 Owner s Manual

Similar documents
LA19 Series Ricochet Battery Powered Level Transmitter and Display

Switch Pro w/ Compact Junction Box A_1_ Series Owner s Manual

Switch-Pak. AU13, AV13 & AZ13 Series Owner s Manual. w/ Compact Relay Controller

Switch-Tek Horizontal and Vertical And Float-Point Float Switches LV20, LV21, LV35, LV36, LH25, LH29, LH35, AV_6 Series 22AUG 08 Rev A

Optic Level Switch LO10 Series Owner s Manual

Smart Trak. AU18, AU28, AU38, AU48, AV16, AV26, AV36, AV46, AZ18, AZ28, AZ38 & AZ48 Series Owner s Manual. w/ Compact Junction Box

AV16, AV26, AV36, AV46, AV56, LH25, LH29, LH35, LV20, LV21, LV35 & LV36 Series Manual

INTRODUCTION / TABLE OF CONTENTS

Thermo Flo Thermal Dispersion Flow Switch FT10 & GT10 Series Manual

XP88 & XP89 Series Quick Start

EchoPod. DL10, DL14, DL24, DS14 & DX10 Series Quick Start. DL14-00 Shown Flowline, Inc. All Rights Reserved Made in USA

User s Guide. LVU-90 Series. Ultrasonic Level Transmitter. Where Do I Find Everything I Need for Process Measurement and Control? OMEGA Of Course!

LU27 Series Quick Start

EchoPod. Technical Support. Model: DL14-(XX) Quick Start

EchoPod. UG06 & UG12 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Ultrasonic Liquid Level Transmitter

LU23, LU28 & LU29 Series Quick Start

EchoPod. UG01 & UG03 Series Quick Start Flowline, Inc. All Rights Reserved Made in USA. Ultrasonic Liquid Level Switch, Controller & Transmitter

Switch Pro Remote Level Controller LC40, LC41 & LC42 Series Manual

EchoSonic. LU23, LU27, LU28 & LU29 Series Manual. Ultrasonic Liquid Level Transmitter

SETRA Operating Instructions Series DPT 230 Pressure Transducers

User s Guide. LVU-19 Series. Battery Powered Level Transmitter & Display

Intrusive RF Capacitance Level Switch LP10 Series Owner s Manual Provided by:

INTRODUCTION / TABLE OF CONTENTS

A Member of the. Integrated Metering Technologies

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

A Member of the. Integrated Metering Technologies

Smart -Trak. AU23, AV23, AZ23 Series Manual. With Compact Relay Controller

INSTALLATION DATA MANUAL Model 510 Pressure Transmitter

MAXIGARD A2000 SPEED SWITCH. Introduction

INSTALLATION DATA MANUAL. Model 521/522 Pressure Transmitter

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

Model 616 Rotating Disk Electrode Instruction Manual

Full View Flow Indicator

QPV1 Electronic Pressure Regulator INSTALLATION AND MAINTENANCE INSTRUCTIONS

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

C3000 SIGNAL TRANSMITTER. Introduction

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

EchoPod DL14, DL24 & DL34 Series Manual Revision A.3

Level Alert Model Multi-Switch Liquid Level Sensor. Assembly and Installation Instructions

EchoPod. DL10, DL14, DL24, DL34, DS14, DX10 Series Manual. Ultrasonic Liquid Level Transmitter, Switch and/or Controller

QSI (Q-Star) Electronics Owner s Manual

CM3000 SIGNAL TRANSMITTER. Introduction. The MAXIGARD CM3000 is designed to convert shaft speed into a 4/20 ma or 0-10 VDC analog output signal.

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

ODY-19-1 AIR PRESSURE GAUGE

Model FMBC3000 Series Operating Instructions. Drum Pump Flow Meter

A1500, A1500NF SPEED SWITCH SINGLE SET POINT - SELF CONTAINED. Introduction

CDS-JOHN BLUE COMPANY

Model GD-K77D4X-XX Supplement to the GD-K77D Operator s Manual

Model FM1000 Series Operating Instructions. Drum Pump Flow Meter

NorthStar. brand. Instruction Manual. SLIM Tach SL Thru-Shaft Diameter. Magnetoresistive Encoder Designed for GE Wind Energy

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

PVI 60KW, PVI 82KW, PVI 95KW

Type 2000 Transducer Product Instructions

CDS-JOHN BLUE COMPANY

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Model GD-70D4A-XX Supplement to the GD-70D Operator s Manual


ZDM Positive Displacement Flow Meter User Instructions

CDS-JOHN BLUE COMPANY

TBM Series 3-Way Ball Valve

PARTS AND INSTALLATION MANUAL

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Dodge Ram 5.9L Cummins LOW FUEL PRESSURE ALARM LIGHT - Installation Manual -

INSTALLATION DATA MANUAL MODEL 148/248/348

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

CBC-300 & CBC Series Dual Channel Adjust Clutch/Brake Controls

RESISTIVITY MONITOR/CONTROLLERS

Owner s Manual FS-10/FreshSpa

U00X ULTRASONIC LEVEL SWITCH. Ultrasonic Liquid Level Switches INSTALLATION AND OPERATIONS MANUAL. For Models: U002, U003 & U004

Broadband PowerShield. CP27U Models. User Manual

NEO-DYN MODELS 100T AND 100TC ADJUSTABLE TEMPERATURE SWITCHES; ENCLOSURE 3X FOR WEATHERPROOF APPLICATIONS INSTALLATION AND OPERATION MANUAL

QSB (Q-Star) Electronics for QSE Electromagnetic Meter. Owner s Manual TABLE OF CONTENTS

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

PENBERTHY FROST PROOF EXTENSION INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

1 2-Inch Station Outlet Valves

ELECTRONIC CONTROLLER

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

INSTALLATION & OPERATION MANUAL

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

INSTALLATION & OPERATION MANUAL

MS40 MS40/EX Explosion

PARTS AND INSTALLATION MANUAL

Flo-Way. Measure Granular or Powdered Material. Stand Alone or Connect to Other Devices for Blending. Used by Successful Producers World-Wide

RP-4000 Reserve Power Control

INSTALLATION AND OPERATION MANUAL

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

VSP SERIES Installation, Operation and Maintenance Manual

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

MANUAL Model: PT 12/24-60 Solar Converters Inc. - Rev. F

Installation Instructions for: Channel Thermocouple Amplifier

1250 LB. CAPACITY MECHANICAL WHEEL DOLLY

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

B2000 SERIES TACHOMETERS DIGITAL OR ANALOG DISPLAYS

Transcription:

Warranty, Service and Repair To register your product with the manufacturer, fill out the enclosed warranty card and return it immediately to: FLOWLINE Inc. 10500 Humbolt Street Los Alamitos, CA 90720 If for some reason your product must be returned for factory service, contact your FLOWLINE distributor to receive a material return authorization number first, providing the following information: 1. Part Number, Serial Number 2. Name and telephone number of a person who can answer questions related to the product and its application. 3. Return shipping address 4. Brief description of the symptom 5. Brief description of the application Once you have received a material return authorization number, ship the product prepaid in its original packing to: FLOWLINE Factory Service 10500 Humbolt Street Los Alamitos, CA 90720 CRICKET Level Model LA12 Owner s Manual Supplied by www.kthsales.com Please include any related symptom and application information with your product. This information enables our service technicians to process your repair order as quickly as possible. Version 2.2A 1999 FLOWLINE Inc. All rights reserved. Part # LA900001 4/99 WARRANTY FLOWLINE warrants to the original purchaser of its products that such products will be free from defects in material and workmanship under normal use and service for a period which is equal to the shorter of one year from the date of purchase of such products or two years from the date of manufacture of such products. This warranty covers only those components of the products which are non-moving and not subject to normal wear. Moreover, products which are modified or altered, and electrical cables which are cut to length during installation are not covered by this warranty. FLOWLINE s obligation under this warranty is solely and exclusively limited to the repair or replacement, at FLOWLINE s option, of the products (or components thereof) which FLOWLINE s examination proves to its satisfaction to be defective. FLOWLINE SHALL HAVE NO OB- LIGATION FOR CONSEQUENTIAL DAMAGES TO PERSONAL OR REAL PROPERTY, OR FOR INJURY TO ANY PERSON. This warranty does not apply to products which have been subject to electrical or chemical damage due to improper use, accident, negligence, abuse or misuse. Abuse shall be assumed when indicated by electrical damage to relays, reed switches or other components. The warranty does not apply to products which are damaged during shipment back to FLOWLINE s factory or designated service center or are returned without the original casing on the products. Moreover, this warranty becomes immediately null and void if anyone other than service personnel authorized by FLOWLINE attempts to repair the defective products. Products which are thought to be defective must be shipped prepaid and insured to FLOWLINE s factory or a designated service center (the identity and address of which will be provided upon request) within 30 days of the discovery of the defect. Such defective products must be accompanied by proof of the date of purchase. THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE OF THIS WARRANTY. This warranty and the obligations and liabilities of FLOWLINE under it are exclusive and instead of, and the original purchaser hereby waives, all other remedies, warranties, guarantees or liabilities, express or implied. EX- CLUDED FROM THIS WARRANTY IS THE IMPLIED WARRANTY OF FITNESS OF THE PRODUCTS FOR A PARTICULAR PURPOSE OR USE AND THE IMPLIED WARRANTY OF MERCHANT ABIL- ITY OF THE PRODUCTS. This warranty may not be extended, altered or varied except by a written instrument signed by a duly-authorized officer of FLOWLINE, Inc. If FLOWLINE level transmitters or switches are used for process control where failure of the transmitter or switch could result in personal injury or property damage, an independent means such as a redundant FLOW- LINE point level switch should be used. Where FLOWLINE level transmitters or switches are used as a part of a pressure vessel or pipe, care should be taken to independently protect against personal injury or property damage should the FLOWLINE sensor fail or be mishandled. Contact FLOWLINE or your local distributor for additional information.

SAFETY PRECAUTIONS Step Two About this Manual: PLEASE READ THE ENTIRE MANUAL PRIOR TO INSTALLING OR USING THIS PRODUCT. This manual includes information on all models of the continuous contact level transmitter from FLOWLINE: LA12- _0_1. Please refer to the part number located on the sensor label to verify the exact model which you have purchased. User s Responsibility for Safety: FLOWLINE manufactures a wide range of liquid level sensors and technologies. While each of these sensors is designed to operate in a wide variety of applications, it is the user s responsibility to select a sensor model that is appropriate for the application, install it properly, perform tests of the installed system, and maintain all components. The failure to do so could result in property damage or serious injury. Proper Installation and Handling: Because this is an electrically operated device, only properly-trained staff should install and/ or repair this product. Use a proper sealant or gasket with all transmitter installations. Note: Always install the Viton gasket with all versions of the LA12-_061. The G threaded version of the Cricket will not seal unless the gasket is installed properly. Never overtighten the transmitter within the fitting, beyond a maximum of 80 inch-pounds torque. Always check for leaks prior to system start-up. Wiring and Electrical: A supply voltage of 12-36 VDC is used to power the LA12 transmitter. The sensor systems should never exceed a maximum of 36 volts DC. Electrical wiring of the sensor should be performed in accordance with all applicable national, state, and local codes. Material Compatibility: The enclosure (LA12 series) is made of Polypropylene with the diaphragm made of Polyethylene (PE). The pipe adapter is made of Polypropylene. The wave guide can be of either Polypropylene, Polyvinylchloride (PVC) or Polyvinylidene Fluoride (PVDF). Make sure that the wave guide which you have selected is chemically compatible with the application liquids it will contact. Enclosure: While the transmitter housing is liquid-resistant when installed properly, it is not designed to be immersed. It should be mounted in such a way that the enclosure and sensing diaphragm do not come into contact with fluid. Flammable, Explosive and Hazardous Applications: The LA12 transmitter systems should not be used within flammable or explosive applications. Make a Fail-Safe System: Design a fail-safe system that accommodates the possibility of transmitter or power failure. In critical applications, FLOWLINE recommends the use of redundant backup systems and alarms in addition to the primary system. WARNING The is shipped with the pipe adapter installed in the true union fitting. Remove the pipe adapter before installing the pipe. Avoid installing the near a source of vibrations or loud repetitive noise, such as a motor. Always install the 1" Viton gasket with all versions of the LA12-_061. The G threaded version of the Cricket will not seal unless the gasket is installed properly. COMPONENTS Step Three Input Terminal: Connect the output device to this terminal. Note the polarity of the terminal. If polarity is not reversed, the transmitter will not operate. Power LED: This Green LED lights when DC power is On. Span: Adjustment for the 4mA setting (invert off) or the 20 ma setting (invert on). Follow instructions in Calibration section, Step 7. Invert: This switch reverses the logic of the output. With Invert Off, 4 ma setting will be at the end of the wave guide and 20 ma setting will be 2" below the top of the threads. With Invert On, 20 ma setting will be at the end of the wave guide and 4 ma setting will be 2" below the top of the threads. 1/2" Conduit Connection: For direct electrical connection. Input Terminal 1/2 Conduit Connection Power LED Diaphragm (PE) Pipe Adapter True Union Tank Fitting Wave Guide (PP, PVC or PVDF) Span Invert Cricket : Housing containing the electronics for the transmitter. The housing is rated NEMA 4X (IP 65) with a material of construction of Polypropylene, U.L. 94 VO. Diaphragm: Sensing transducer for transmitting and receiving the sound pulses. The material of construction for the diaphragm is Polyethylene (PE). Pipe Adapter: Attaches the wave guide to the transmitter in conjunction with the true union fitting. Material of construction for the pipe adapter is PP and the female thread is a 1/2" NPT. True Union Fitting: Attaches the wave guide to the transmitter. Also provides the mounting threads for the. Threads for the true union fitting are either 1" NPT or 1" G. Material of construction for the true union fitting is Polypropylene. Wave Guide: Device which directs the sound pulses created by the transmitter. Materials of construction for wave guides are Polypropylene, Polyvinylidene Fluoride (PVDF) or Polyvinylchloride (PVC).

ASSEMBLY Step Four MODEL LA12-_0_1-00" ONLY: Cricket wave guides may be assembled in the factory or in the field. If your Cricket was factory assembled, skip to installation. If your Cricket requires field assembly, then use the following instructions below. 1. First, remove the true union fitting from the transmitter. The assembly can be removed by hand. CALIBRATION Step Five The measurement span may be calibrated over the entire range of the wave guide. Use the following procedure to calibrate the measurement span. 1. Connect a multimeter in series to read current. The top of the Cricket's current signal is located 2" from the bottom of the threads. The calibration procedure for the transmitter requires that the bottom of the transmitter's current signal be set using the Span potentiometer. 2. Set Invert switch to OFF. 3. Set level to lowest point. A cup of liquid or a piece of tape over the end of the pipe may be used as a substitution for a low level reading. 2. Turn a 1/2" NPT male thread on the end of the 1/2" schedule 40 or 80 pipe. 3. Locate the pipe adapter and thread the pipe into the 1/2" NPT thread. 4. Turn Span until current reads 4 ma. Turning pot counterclockwise will lower the current and turning the pot clockwise will increase the current. Always increase current to above 5 ma and slowly return to 4 ma for best results. The is now calibrated for normal operation. Remove the cup of water or tape and continue on to Installation (Step Six). If the Cricket's current signal is need to be reversed (20 ma at the end of the pipe), continue on to step five. 4. Drill a 1/8" pressure equalization hole through the pipe. The location of the hole should be placed from 1" to 1-1/2" from the top of the wave guide. 1/8" D. 1" to 1-1/4" 5. Make sure all burrs have been removed from the pipe ID. 6. Insert the wave guide assembly into the true union fitting. 5. Turn Invert to ON if 20 ma signal at end of LA12 is required. Adjust pot until 20 ma is read. Always decrease current to below 19 ma and slowly increase to 20 ma for best results. 6. Remove cup of water or tape if required. Power Supply CALIBRATION 4 5 6 ma OFF com (+) True Union Tank Fitting Wave Guide Assembly 7. Finally, insert the assembled pieces into the transmitter. Tighten the fitting to hand tight. 8. Proceed to the calibration section. 20 ma Invert OFF 4 ma Always use a 1/2" schedule 40 or 80 (PP, PVDF or PVC) pipe. 4 ma Invert ON ON 20 ma

INSTALLATION Step Six FLOWLINE s LA12 transmitter may be installed through the tank top, through a stand pipe top or to the side of a tank. Tank top and stand pipe installations require a 1" NPT fitting or blind flange. Side wall installations require a side mount bracket from FLOWLINE, model LM50-1001, and a 2" to 1" NPT reducer bushing or equivalent. 1. Install the appropriate 1" fitting in the top wall of the tank or stand pipe. Prior to installation, make sure that the fitting has been installed properly and checked for leaks. Use a proper sealant at the time of installation to ensure a liquid-tight seal. Secondly, make sure that the fitting s threads are not damaged or worn. WIRING Step Seven Remove the cap of the LA12 transmitter enclosure. The terminals of the transmitter are visible from the top of the enclosure. 1. Wiring to a FLOWLINE Continuous Controller (LC52): Connect the (+) terminal to the positive 24 VDC, 4-20 ma terminal on the LC52 controller. Connect the (-) terminal to the terminal on the LC52 continuous controller (See illustration below). Check LC52 instruction manual for setting the LC52 for loop powered operation. 2. Unscrew the True Union Tank Fitting from the transmitter. Install True Union Tank Fitting along with the Wave Guide Assembly into the fitting. Apply the appropriate amount of sealant to the tapered threads which will be screwed into the fitting. LATCH PWR PROPORTIONAL CONTROLLER RELAY 1 DELAY OFF SET RLY1 RLY2A RLY2B 0% INPUT 100% RELAY 2 DELAY EASY CAL 4 20 OP UP DOWN SET 3. Insert the on the True Union Tank Fitting and tighten to hand tight. 4. Always check for leaks prior to system start-up. To ensure proper installation, a complete leak test and simulation of actual process conditions should be preformed. LM50 Side Mount Bracket Tank Top Mounting Stand Pipe Mounting 2. Wiring to a Two-Wire Loop Indicator: The LA12 requires a loop indicator that receives a current input. A 12-36 VDC power supply is required for the system. Connect the (+) terminal of the LA12 transmitter to the positive VDC terminal on the power supply. Connect the (-) terminal on the LA12 to the (+) terminal on the loop indicator. Connect the (-) of the loop indicator to the (-) of the power supply (See illustration below). DC Power Supply 12-36 VDC + - - + 3. Wiring to a typical PLC: The LA12 requires a PLC which provides a 12-36 VDC excitation and receives a current input. Connect the (+) terminal of the LA12 transmitter to the positive VDC power terminal. Connect the (-) terminal on the LA12 to the (+) channel on the PLC. Connect the (-) of the PLC to the (-) of the power terminal (See illustration below). WARNING Avoid installing the near a source of vibrations or loud repetitive noise, such as a motor. DC Power Supply 12-36 VDC + - 6 5 4 3 2 1 0 A Typical PLC 250Ω Do not insert or remove the quickly from its fitting. Doing so may increase the back pressure within the pipe and cause the diaphragm to rupture. Always install the 1" Viton gasket with all versions of the LA12-_061. The G threaded version of the Cricket will not seal unless the gasket is installed properly.

MAINTENANCE Step Eight General: The LA12 series level transmitter itself requires no periodic maintenance except cleaning as required. It is the responsibility of the user to determine the appropriate maintenance schedule, based on the specific characteristics of the application liquids. Cleaning Procedure: 1. Power: Make Sure that all power to the transmitter, controller and/or power supply is completely disconnected. 2. Sensor Removal: In all through-wall installations, make sure that the tank is drained well below the sensor prior to removal. Carefully, remove the sensor from the installation. 3. Cleaning the Sensor: Use a soft bristle brush and mild detergent, carefully wash the wave guide of the LA12. Do not use harsh abrasives such as steel wool or sandpaper, which might damage the transmitter's surface. Do not use incompatible solvents which may damage the transmitters PP, PVDF or PVC plastic body. 4. Sensor Installation: Follow the appropriate steps of installation as outlined in the installation section of this manual.

SPECIFICATIONS Step One : 0.3 to 10' (9 cm to 3 m) Accuracy: ± 1% of span in air Resolution: 0.125 (3 mm) Frequency: 2 khz (nominal) Pulse rate: 5 per second Dead band: 0.3' (5 cm) minimum Supply voltage: 12-36 VDC Loop resistance: 600 ohms @ 36 VDC Signal output:, 12-36 VDC Signal invert: or 20-4 ma Minimum range: 8 Maximum range: 120" Span adjustment: Potentiometer Indication: LED for power status Temperature rating: F: -40º to 140º C: -40º to 60º Temp. compensation: Automatic over range Pressure rating: Atmospheric Wave guide: Schedule 40 or 80, 1/2" Guide materials: PVC, PP or PVDF Enclosure rating: NEMA 4X / IP65 Enclosure material: Polypropylene, U.L. 94 VO Diaphragm material: Polyethylene Mounting threads: 1 NPT (1" G) Mounting gasket: Viton 1" (metric only) Conduit connection: 1/2 NPT Thread material: PP CE compliance: EN 50082-2 immunity EN 55011 emission LA12 - _ 0 _ 1 Guide Material 1 - PP 5 - PVDF 7 - PVC Mounting Thread 0-1" NPT 2-1" G About Contact Technology: An sound wave is pulsed five times per second from the base of the transducer. The sound wave travels down the pipe and reflects against the process medium below before returning back to the receiver. The electronics measures the time of flight between the sound generation and receipt, and translates this figure into the distance between the transmitter and process medium below. Diaphragm (PE) Pipe Adapter Ambient Sensor Temperature ( C) Maximum Temperature/Voltage Derating Continuous 20 ma Curve 100 80 60 40 20 Unacceptable Acceptable 0 12 16 20 24 28 32 36 Operating Voltage (VDC) Max. Series Resistance (Ohms) 1,400 1,200 1,000 800 600 400 200 000 Flowline Electrical Loading Limits Unacceptable Acceptable 12 18 24 30 36 Supply Volyage (VDC) True Union Tank Fitting Wave Guide (PP, PVC or PVDF) 2.8" (71mm) 4.2" (106mm) 4.7" (119mm) 5.9" (149mm) 1.0" (25mm) A (Specify)