SeasonPak Packaged Air-Cooled Water Chiller

Similar documents
Air-Cooled Screw Compressor Chiller

AIR COOLED CHILLERS WATER COOLED CHILLERS

Air-Cooled Scroll Compressor Chiller

Optional Pump Packages for

SCROLL - AIR COOLED PACKAGED & SPLIT SYSTEM ICE CHILLERS

PACKAGED LIQUID CHILLER 6. HUMIDIFIER SECTIONS. C Member. Liquid Chiller. nowlc And noalc Series

Air Cooled Water Chillers. CLS 182 to to 150 kw. Technical Brochure TM CLS-W.3GB Date : October 2004 Supersedes : TM CLS-W.2GB/07.

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H2CA300, 360, 480 & THRU 50 NOMINAL TONS

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT:

Installation Instructions

VLH 504 to Air-to-Water Reverse Cycle Heat Pumps. 126 to 294 kw. 133 to 307 kw

RCD Air Cooled Condensing Unit (50/60 Hz)

TECHNICAL GUIDE DESCRIPTION MODELS: D4HH 024 THRU 180 HORIZONTAL FEATURES SINGLE PACKAGE AIR CONDITIONERS HORIZONTAL INDOOR & CONDENSER AIR FLOW

DESCRIPTION FEATURES

Pathfinder Remote Evaporators

Liebert CSU3000 DISCONTINUED PRODUCT. CSI Mainframe Cooling Systems. CT(Three Module) Model 20, 30 & 37 ton Mainframe Chiller

Product Catalog. NQ Series. Portable and Remote Air-Cooled Condenser Chillers 4 to 43 Tons

Direct Drive Fluid Coolers Catalog 607. Type AFS 005 through AFS 107 Type AFD 046 through AFD 212

Installation Instructions

Product Data. Features/Benefits. 30HXA HXC Condenserless and Fluid-Cooled Chillers 50/60 Hz. 75 to 265 Tons (264 to 931 kw)


Product Data. Features/Benefits. 30GXN,R ECOLOGIC Air-Cooled Chiller with ComfortLink Controls 50/60 Hz. 80 to 450 Tons (267 to 1511 kw)

30GX AIR-COOLED LIQUID CHILLER

Consider The Possibilities...

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS 50 AND 60 HZ DESCRIPTION FEATURES

Air-Cooled Liquid Chiller with integrated hydraulic module

DESCRIPTION ACCESSORIES FIELD INSTALLED SPLIT-SYSTEM EVAPORATOR BLOWERS KBBU060, KDBC090, KCBC120 & KCBC180 5 THRU 15 NOMINAL TONS SUPPLY AIR PLENUMS

Product Data. Features/Benefits. 30GUN,GUR Air-Cooled Reciprocating Liquid Chillers (HFC-134a) with ComfortLink Controls 50/60 Hz

PH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C

Installation, Start-Up and Service Instructions

D M S 760 C01 A A 1 1

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS FEATURES DESCRIPTION. H5CE090 & H3CE AND 10 NOMINAL TONS (World 50HZ)

30GX AIR-COOLED LIQUID CHILLER

SINGLE PACKAGE AIR CONDITIONING WATER COOLED

CONTINUOUS CAPACITY CONTROL MODELS

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

R2H3. Product Specifications 3 PHASE HEAT PUMP COMPONENT. For Use With R 22 Refrigerant. 2 1/2 THRU 5 TONS 208 / 230 Volt, 3 phase, 60 Hz

Product Data. Features/Benefits. 30GTN,GTR Air-Cooled Reciprocating Liquid Chillers with ComfortLink controls 50/60 Hz

INSTALLATION, START-UP AND SERVICE INSTRUCTIONS

Table of Contents. 1. Model Designation And Unit Models Guide Specifications Technical Data Performance Data 10

Co m f o r t Li n k N A V I G A T O R F F

CSA6. Product Specifications. SoftSound SXC 2600

CPC Commercial. 15- & 20-Ton, Three-Phase Packaged Air Conditioner. 20-Ton Cooling Capacity: 240,000 BTU/h

Product Catalog TSE Series Scroll Central Chillers

YCWL WATER-COOLED SCROLL LIQUID CHILLER

SLH 1202 to Air-to-Water Reverse Cycle Heat Pumps. With Screw Compressors. 261 to 775 kw. 287 to 853 kw

Comfort. Description. Applications

Product Catalog TSE Series Scroll Central Chillers

McQuay Air-Cooled Reciprocating Chiller ALR

SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS

1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

TWA S/K/P. Incorporating. R410A Air cooled water chillers with axial fans and scroll compressors from 189 kw to 1007 kw

Air-Cooled Fluid Cooler

Installation Instructions

technical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO

Product Data. Features/Benefits

CGA CXA VGA VXA CG-PRC006-E4

R-22, 13 SEER 60 Hertz

Typical Applications. Horizontal Installation

TSA6. Product Specifications. SmartComfort TXC 5600

LUI / LUO. Condensing Units

Q6SE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase

Q3RD Series. Single Packaged Heat Pump, Single Phase TECHNICAL SPECIFICATIONS FEATURES AND BENEFITS

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES EB COMPACT PACKAGED CHILLERS PART 1 GENERAL

Chiller. SWS/SWR 1602 to Water Cooled Chillers Cooling Only and Condenserless Versions Engineering Data Manual.

EFFICIENCY 17 SEER TWO STAGE AIR CONDITIONER WITH OBSERVER

Air Cooled Single Screw Chiller/ Heat Pump

WATER SOURCE HEAT PUMPS

N4A6. Product Specifications

FORM NO. HSC-543 AIR HANDLERS

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH

PERFORMANCE DATA TYPICAL FIELD WIRING CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS

SUNLINE 2000 SINGLE PACKAGE GAS / ELECTRIC UNITS AND SINGLE PACKAGE AIR CONDITIONERS DESCRIPTION FEATURES

ELITE SERIES R-410A Ready - Multi-Position

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

S3BN Series Split System Air Conditioner 10.3 EER Commercial System 7½ and 10 Ton Capacity R-22 Refrigerant

R4A5. Product Specifications EFFICIENT 14 SEER/ EER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

A I R H A N D L E R S CB26UH-R. MERIT Series R-22 - Upflow / Horizontal P R O D U C T S P E C I F I C AT I O N S

FRICTION-FREE COIL TRACKS AIR-COOLED CONDENSERS FROM 28 MBH TO 4000 MBH

Q7RE Series Single Packaged Heat Pump, Single Phase

SUNLINE 2000 SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS DESCRIPTION FEATURES H4CE090 & H2CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

S6BQ Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Split System 2-Stage Air Conditioner. 7 1/2 and 10 Ton rated at 11.2 EER and 12.

CPH COMMERCIAL 7½- TO 10-TON SELF-CONTAINED PACKAGED HEAT PUMP

10AC DIPLOMAT SERIES RFC SYSTEMS

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Next-Gen MiniCon 1/2 TO 6 HP MULTI-REFRIGERANT AIR COOLED CONDENSING UNITS

50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS

R2A3. Product Specifications AIR CONDITIONER COMPONENT. For Use With R 22 Refrigerant. 1 1/2 THRU 5 TONS 208 / 230 Volt, 1 phase, 60 Hz

CPC Commercial. 7½- to 12½-Ton Three-Phase. up to 11.5 EER. Cooling Capacity: 90, ,000 BTU/h. Packaged Air Conditioners

WCA4**4. Product Specifications

ACS Screw Water Chiller R-134a

Q5RD Series Single Packaged Heat Pump, Single Phase

ZHA/ZHB SERIES WARNING

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

APARTMENT FAN COILS AVAILABLE WITH FACTORY INSTALLED 5, 7, & 11 kw ELECTRIC HEAT, or NO HEAT R -22 SYSTEMS

SPLIT-SYSTEM EVAPORATOR BLOWER DESCRIPTION ACCESSORIES EER 8.5 ARI RATINGS* K2ES120A25 10 NOMINAL TONS WITH TWO 5 TON CIRCUITS

S5BP Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS

R4A4. Product Specifications EFFICIENT 14 SEER AIR CONDITIONER ENVIRONMENTALLY SOUND R 410A REFRIGERANT

Transcription:

Installation Manual IM 676 Group: Chiller Part Number: 594920Y Date: July 1996 Supersedes: None SeasonPak Packaged Air-Cooled Water Chiller Models ALR 032E Through 185E 1996 McQuay International

Table of Contents Introduction...3 General Description...3 Inspection...3 Installation...3 Handling...3 Location...4 Service Access...5 Vibration Isolators...6 Water Piping...7 Flow Switch...8 Water Connections...8 Refrigerant Charge...9 Glycol Solutions...9 Evaporator Water Flow and Pressure Drop...10 Physical Data...12 Electrical Data...18 Field Wiring...18 Dimensional Data...36 Unit Layout and Principles of Operation...38 Control Center...38 Start-up and Shutdown...40 Pre Start-up...40 Start-up...40 Sequence of Operation...41 2 IM 676

Introduction General Description McQuay SeasonPak air-cooled water chillers are complete, self-contained automatic refrigerating units. Every unit is completely assembled, factory wired, charged, and tested. Each unit consists of twin air-cooled condensers with integral subcooler sections, multiple accessible hermetic compressors, replaceable tube dual circuit shell-and-tube evaporator, and complete refrigerant piping. Liquid line components include manual liquid line shutoff valves, sight-glass/moisture indicators, solenoid valves, and double diaphragm hydraulic element thermal expansion valves. Other features include compressor crankcase heaters, an evaporator heater for chilled water freeze protection, limited pumpdown during on or off periods, compressor lead-lag switch to alternate the compressor starting sequence, and sequenced starting of compressors. The electrical control center includes all safety and operating controls necessary for dependable automatic operation. Condenser fan motors are fused in all three phases and started by their own three-pole contactors. Compressors are not fused but may be protected by optional circuit breakers, or by a field installed fused disconnect. Inspection Check all items carefully against the bill of lading. Inspect all units for damage upon arrival. Report shipping damage and file a claim with the carrier. Check the unit name plate before unloading, making certain it agrees with the power supply available. McQuay is not responsible for physical damage after unit leaves the factory. Note: Unit shipping and operating weights are available in the Physical Data tables beginning on page 12. Installation Note: Installation is to be performed by qualified personnel who are familiar with local codes and regulations. WARNING Sharp edges and coil surfaces are a potential hazard. Avoid contact with them. Handling Be careful to avoid rough handling of the unit. Do not push or pull the unit from anything other than the base. Block the pushing vehicle away from the unit to prevent damage to the sheet metal cabinet and end frame (see Figure 1). To lift the unit, 2 1/2" (64mm) diameter lifting holes are provided in the base of the unit. Arrange spreader bars and cables to prevent damage to the condenser coils or cabinet (see Figure 2). IM 676 3

Figure 1, Suggested pushing arrangement Blocking required across full width Figure 2, Suggested lifting arrangement Spreader bars recommended (Use Caution) NOTE: Number of fans can vary from this diagram. Lifting method remains the same. Location Must use these rigging holes. (Be aware of control box location) Unit Placement ALR units are for outdoor applications and can be mounted on a roof or ground level. Set units on a solid and level foundation. For roof mounted applications, install the unit on a steel channel or I- beam frame to support the unit above the roof. For ground level applications, install the unit on a substantial base that will not settle. A one piece concrete slab with footings extended below the frost line is recommended. Be sure the foundation is level (within 1/2 [13 mm] over its length and width). The foundation must support the operating weights listed in the Physical Data tables beginning on page 12. On ground level applications protect fins against vandalism using the optional coil guards or by erecting a screen fence. The fence must allow free flow of air to the condenser coil for proper unit operation. 4 IM 676

Clearances The flow of air to and from the condenser coil must not be limited. Restricting air flow or allowing air recirculation will result in a decrease in unit performance and efficiency. There must be no obstruction above the unit that would deflect discharge air downward where it could be recirculated back to the inlet of the condenser coil. The condenser fans are propeller type and will not operate with ductwork on the fan outlet. Install the unit with enough side clearance for air entrance to the coil and for servicing. Provide service access to the evaporator, compressors, electrical control panel and piping components as shown in Figure 3. Do not allow debris to accumulate near the unit. Air movement may draw debris into the condenser coil causing air starvation. Give special consideration to low ambient operation where snow can accumulate. Keep condenser coils and fan discharge free of snow or other obstructions to permit adequate airflow. Figure 3, Clearance requirements 5 ft. (1524mm) Clearance for air inlet 4 Ft. (1220mm) clearance for service access "X" clearance for evaporator tube removal 5 Ft. (1524mm) clearance for air inlet ALR Unit Size 032E -075E 080E - 185E Minimum "X" Dimension 8 ft (2438 mm) 10 ft (3048 mm) Sound Isolation The ultra-low sound levels of the ALR reciprocating chiller is suitable for most applications. When additional sound reduction is necessary, locate the unit away from sound sensitive areas. Avoid locations beneath windows or between structures where normal operating sounds may be objectionable. Reduce structurally transmitted sound by isolating water lines, electrical conduit and the unit itself. Use wall sleeves and rubber isolated piping hangers to reduce transmission of water or pump noise into occupied spaces. Use flexible electrical conduit to isolate sound through electrical conduit. Spring isolators are effective in reducing the low amplitude sound generated by reciprocating compressors and for unit isolation in sound sensitive areas. Service Access Each end of the unit must be accessible after installation for periodic service. Compressors, filterdriers, and manual liquid line shutoff valves are accessible on each side of the unit adjacent to the control box. High pressure, low pressure, and motor protector controls are on the compressor. Freezestats and cooler barrel thermostats are near the cooler. Most other operational, safety and starting controls are located in the unit control box. The condenser fan and motors can be removed from the top of the unit. IM 676 5

Vibration Isolators Vibration isolators are recommended for all roof mounted installations or wherever vibration transmission is a consideration. Table 1 lists isolator loads and type. Table 2 lists spring isolator part numbers for all unit sizes. See Dimensional Data beginning on page 36 for dimensions required to secure each isolator to the mounting surface. Table 1, Isolator loads and type ALR ISOLATOR LOADS AND TYPE FOR EACH MOUNTING LOCATION UNIT R S T SIZE TYPE LB. KG TYPE LB. KG TYPE LB. KG 032E CP-1-28 669 303 CP-1-28 677 307 CP-1-28 677 307 035E CP-1-28 673 305 CP-1-28 680 308 CP-1-28 680 308 040E CP-1-28 692 314 CP-1-28 699 317 CP-1-28 699 317 045E CP-1-31 804 365 CP-1-31 794 360 CP-1-31 785 356 050E CP-1-31 822 373 CP-1-31 798 362 CP-1-31 800 363 055E CP-1-31 827 375 CP-1-31 819 371 CP-1-31 809 367 060E CP-1-32 850 386 CP-1-32 841 381 CP-1-32 835 379 065E CP-1-32 868 394 CP-1-32 858 389 CP-1-32 848 385 070E CP-1-32 1040 472 CP-1-32 998 453 CP-1-32 912 414 075E CP-1-32 1042 473 CP-1-32 1019 462 CP-1-32 914 415 080E CP-2-28 1110 503 CP-2-28 1122 509 CP-2-31 1296 588 085E CP-2-28 1180 535 CP-2-28 1186 538 CP-2-31 1474 669 090E CP-2-28 1182 536 CP-2-28 1186 538 CP-2-31 1475 669 100E CP-2-28 1193 541 CP-2-28 1214 551 CP-2-31 1508 684 110E CP-2-28 1339 607 CP-2-28 1364 619 CP-2-31 1697 770 120E CP-2-31 1362 618 CP-2-31 1490 676 CP-2-32 1748 793 130E CP-2-31 1492 677 CP-2-32 1570 712 CP-2-32 1838 834 135E CP-2-31 1506 683 CP-2-32 1670 758 CP-2-32 1904 864 140E CP-2-31 1556 706 CP-2-32 1752 795 CP-2-32 1912 867 145E CP-2-31 1572 713 CP-2-32 1680 762 CP-4-27 2093 949 150E CP-2-32 1601 726 CP-2-32 1704 773 CP-4-27 2120 962 160E CP-4-27 1948 884 CP-2-32 1962 890 CP-2-32 1848 838 170E CP-4-27 2052 931 CP-2-32 2002 908 CP-2-32 1849 839 180E CP-4-27 2052 931 CP-2-32 2002 908 CP-2-32 1849 839 185E CP-4-27 2052 931 CP-2-32 2002 908 CP-2-32 1849 839 NOTE: Two of each isolator type is required for a total of six per unit. Table 2, Spring flex isolator part numbers Max. Load TYPE COLOR McQuay Each Part No. Lb. KG CP1-25 Red 477927A-25 450 204 CP1-26 Purple 477927A-26 600 272 CP1-27 Orange 477927A-27 750 340 CP1-28 Green 477927A-28 900 408 CP1-31 Gray 477927A-31 1100 499 CP1-32 White 477927A-32 1300 590 CP2-25 Red 477929A-25 900 408 CP2-26 Purple 477929A-26 1200 544 CP2-27 Orange 477929A-27 1500 681 CP2-28 Green 477929A-28 1800 817 CP2-31 Gray 477929A-31 2200 998 CP2-32 White 477929A-32 2600 1180 CP4-26 Purple 580513A-26 2400 1089 CP4-27 Orange 580513A-27 3000 1361 CP4-28 Green 580513A-28 3600 1633 CP4-31 Gray 580513A-31 4400 1996 CP4-32 White 580513A-32 5200 2359 6 IM 676

Water Piping Local authorities can supply the installer with the proper building and safety codes required for safe and proper installation. Install piping with minimum bends and changes in elevation to minimize pressure drop. Consider the following when installing water piping: 1. Vibration eliminators to reduce vibration and noise transmission to the building. 2. Shutoff valves to isolate the unit from the piping system during unit servicing. 3. Manual or automatic air vent valves at the high points of the system. Install drains at the lowest points in the system. 4. A means of maintaining adequate system water pressure (expansion tank or regulating valve). 5. Temperature and pressure indicators located at the unit to aid in unit servicing. 6. A strainer or other means of removing foreign matter from the water before it enters the pump. Place the strainer far enough upstream to prevent cavitation at the pump inlet (consult pump manufacturer for recommendations). The use of a strainer will prolong pump life and keep system performance up. 7. Place a strainer in the water line just before the inlet of the evaporator. This will help prevent foreign material from entering and decreasing the performance of the evaporator. CAUTION If separate disconnect is used for the 110V supply to the evaporator heating cable, mark the disconnect clearly to ensure disconnect is not accidentally shut off during cold seasons. 8. The shell-and-tube evaporator has a thermostat and heating cable to prevent freeze-up down to - 20 F (-29 C). It is suggested that the heating cable be wired to a separate 110V supply circuit. As shipped from the factory, the heating cable is wired to the control circuit. All water piping to the unit must also be protected to prevent freezing. 9. If the unit is used as a replacement chiller on a previously existing piping system, flush the system thoroughly before unit installation. Regular water analysis and chemical water treatment on the evaporator is recommended immediately at equipment start-up. 10. The total water volume in the system should be sufficient to prevent frequent on-off cycling. Turnover rate should not be less than 15 minutes for normal variable cooling loads. Turnover rate for process cooling or a constant load,should not be less than 6 minutes. 11. When glycol is added to the water system for freeze protection, the refrigerant suction pressure will be lower, cooling performance less, and water side pressure drop greater. If the percentage of glycol is high, or if propylene is used instead of ethylene glycol, the added pressure drop and loss of performance could be substantial. Reset the freezestat and low leaving water alarm temperatures. The freezestat is factory set to default at 36 F (2.2 C). Reset the freezestat setting to approximately 4 to 5 degress F (2.3 to 2.8 degress C) below the leaving chilled water setpoint temperature. See the section titled Glycol Solutions for additional information concerning glycol. 12. Perform a preliminary leak check before insulating the piping and filling the system. 13. Piping insulation should include a vapor barrier to prevent condensation and possible damage to the building structure. IM 676 7

Figure 4, Typical field evaporator water piping Vent Outlet Drain Vibration Eliminator Valved pressure gauge Water strainer Vibration Eliminator Gate valve Flow Balancing Switch valve Protect all field piping against freezing Gate valve Flow Switch Mount a water flow switch in either the entering or leaving water line to shut down the unit when water flow is interrupted. A flow switch is available from McQuay (part number 00175033-00). It is a paddle type switch and adaptable to any pipe size from 3 (76mm) to 8 (203mm) nominal. Certain minimum flow rates are required to close the switch and are listed in Table 3. Installation should be as shown in Figure 5. Connect the normally open contacts of the flow switch in the unit control center at terminals 5 and 6. There is also a set of normally closed contacts on the switch that can be used for an indicator light or an alarm to indicate when a no flow condition exists. Freeze protect any flow switch that is installed outdoors. NOTE: Differential pressure switches are not recommended for outdoor installation. Table 3, Flow switch minimum flow rates NOMINAL PIPE SIZE MINIMUM REQUIRED FLOW TO INCHES (MM) ACTIVATE SWITCH - GPM (L/S) 1 (25.4) 6.00 (0.38) 11/4 (31.8) 9.80 (0.62) 11/2 (38.1) 12.70 (0.80) 2 (50.8) 18.80 (1.20) 21/2 (63.50 24.30 (1.50) 3 (76.20 30.00 (1.90) 4 (101.6) 39.70 (2.50) 5 (127.0) 58.70 (3.70) 6 (152.4) 79.20 (5.00) Figure 5, Flow switch installation Flow direction marked on switch 1" (25mm) NPT flow switch connection Tee 5" (127mm) pipe dia. Min. after switch 5" (127mm) pipe dia. Min. before switch Water Connections Bring water piping to the cooler from the bottom of the unit or through the side between the vertical supports. 8 IM 676

Note: On units sizes 160E through 185E there is a diagonal bracket off of a vertical support which will interfere with the water connection if brought in from the side. This brace can be removed, but only after the unit is in place. Refrigerant Charge All units are designed for use with HCFC-22 and other refrigerants. See nameplate for specific refrigerant used. Units are shipped with an operating charge. The operating charge (using HCFC-22) for each unit is shown in the Physical Data tables beginning on page 12. Note: The procedure does not specify the type of glycol. Use the derate factors found in Table 4 for corrections when using ethylene glycol and those in Table 5 for propylene glycol. Glycol Solutions The system glycol capacity, glycol solution flow rate in GPM, and pressure drop through the cooler may be calculated using the following formulas and table. 1. Capacity -- Find the reduced capacity by multiplying the chiller s capacity with water by the capacity correction factor C. 2. Flow -- To determine evaporator gpm (or Delta-T) knowing Delta-T (or gpm) and capacity: 24 capacity( glycol) Glycol GPM = G (from table) Delta T For Metric Applications -- To determine evaporator L/s (or Delta-T) knowing Delta-T (or L/s) and kw: kw Glycol L / s = Flow(from table) 4.18 Delta T 3. Pressure drop -- To determine pressure drop through the evaporator, when using glycol, enter the water pressure drop curve on page 11 at the actual glycol GPM. Multiply the water pressure drop by PD correction factor from Table 4 or Table 5 to obtain corrected glycol pressure drop. 4. To determine the unit's power consumption when using glycol, multiply the water system kw by factor kw. Test coolant with a clean, accurate glycol solution hydrometer (similar to that found in service stations) to determine the freezing point. Obtain percent glycol from the freezing point table below. On glycol applications it is normally recommended by the supplier that a minimum of 25% solution by weight be used for protection against corrosion. IM 676 9

CAUTION Do not use an automotive grade antifreeze. Industrial grade glycols must be used. Automotive antifreeze contains inhibitors which will cause plating on the copper tubes within the chiller evaporator. The type and handling of glycol used must be consistent with local codes. Table 4, Ethylene glycol % Freeze Point E.G. F C Cap. kw GPM PD 10 26-3 0.991 0.996 1.013 1.070 20 18-8 0.982 0.992 1.040 1.129 30 7-14 0.972 0.986 1.074 1.181 40-7 -22 0.961 0.976 1.121 1.263 50-28 -33 0.946 0.966 1.178 1.308 Table 5, Propylene glycol % Freeze Point P.G. F C Cap. kw GPM PD 10 26-3 0.987 0.992 1.010 1.068 20 19-7 0.975 0.985 1.028 1.147 30 9-13 0.962 0.978 1.050 1.248 40-5 -21 0.946 0.971 1.078 1.366 50-27 -33 0.929 0.965 1.116 1.481 Table 6, Capacity and power derates Chilled Water Fouling Factor Delta-T 0.00025 (0.044) 0.00075 (0.132) 0.00175 (0.308) ALTITUDE F C Cap. kw Cap. kw Cap. kw 6 3.3 0.992 0.995 0.996 0.982 0.911 0.935 8 4.4 0.995 0.997 0.969 0.984 0.914 0.937 SEA 10 5.6 1.000 1.000 0.975 0.986 0.919 0.939 LEVEL 12 6.7 1.005 1.002 0.980 0.989 0.923 0.941 14 6.8 1.010 1.005 0.985 0.991 0.928 0.943 16 8.9 1.014 1.007 0.989 0.993 0.930 0.944 6 3.3 0.978 1.005 0.957 0.990 0.903 0.943 8 4.4 0.982 1.007 0.961 0.993 0.905 0.945 10 5.6 0.986 1.009 0.965 0.995 0.909 0.947 2000 feet 12 6.7 0.992 1.011 0.970 0.998 0.914 0.949 14 6.8 0.997 1.014 0.973 1.001 0.919 0.952 16 8.9 1.000 1.016 0.975 1.002 0.921 0.953 6 3.3 0.966 1.016 0.944 0.999 0.894 0.951 8 4.4 0.969 1.018 0.947 1.001 0.896 0.953 10 5.6 0.973 1.021 0.952 1.005 0.900 0.956 4000 feet 12 6.7 0.978 1.025 0.956 1.008 0.904 0.958 14 6.8 0.982 1.027 0.959 1.011 0.909 0.960 16 8.9 0.986 1.028 0.961 1.015 0.911 0.961 6 3.3 0.953 1.025 0.930 1.009 0.884 0.961 8 4.4 0.955 1.028 0.934 1.011 0.887 0.962 10 5.6 0.959 1.031 0.939 1.013 0.890 0.964 6000 feet 12 6.7 0.963 1.034 0.942 1.017 0.895 0.966 14 6.8 0.968 1.036 0.946 1.020 0.899 0.968 16 8.9 0.972 1.037 0.949 1.024 0.902 0.969 10 IM 676

Evaporator Water Flow and Pressure Drop Evaporator flow rate must fall between the minimum and maximum values shown in the evaporator pressure drop curve. Flow rates below the minimum values will result in laminar flow which will reduce efficiency, cause erratic operation of the expansion valve and could cause low temperature cutouts. Flow rates exceeding the maximum values can cause erosion on the evaporator water connections and tubes. Measure the chilled water pressure drop through the evaporator at field installed pressure taps. It is important not to include the effect of valves or strainers in these readings. Varying chilled water flow through the evaporator while the compressor(s) are operating is not recommended. Figure 6, Evaporator water pressure drop curve IM 676 11

Physical Data Table 7, Physical data ALR032E Through 050E PHYSICAL DATA ALR MODEL NUMBER 032E 035E 040E 045E 050E BASIC DATA Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Unit Capacity @ ARI Conditions (1), 32.5 (114.3) 34.6 (121.7) 40.4 (142.0) 45.9 (161.4) 50.8 (178.6) Tons (kw) Number Of Refrigerant Circuits 2 2 2 2 2 Unit Operating Charge, R-22, lb. 20 20 23 23 30 30 32 32 32 32 Unit Operating Charge, R-22, (kg) (9.1) (9.1) (11.3) (11.3) (13.6) (13.6) (13.6) (13.6) (13.6) (13.6) Cabinet Dimensions, LxWxH, In. 123 x 83 x 59 123 x 83 x 59 123 x 83 x 59 176 x 83 x 59 176 x 83 x 59 Cabinet Dimensions, LxWxH, (mm) (3124 x 2108 x 1499) (3124 x 2108 x 1499) (3124 x 2108 x 1499) (4470 x 2108 x 1499) (4470 x 2108 x 1499) Unit Operating Weight, Lb. (kg) 4045 (1835) 4065(1853) 4180 (1896) 4765 (2162) 4840 (2196) Unit Shipping Weight, Lb. (kg) 3895 (1767) 3915 (1785) 4030 (1828) 4615 (2094) 4690 (2127) Add'l Weight If Copper Finned Coils, Lb. (kg) 270 (122) 270 (122) 370 (168) 410 (186) 410 (186) COMPRESSORS Type Semi-Hermetic Semi-Hermetic Semi-Hermetic Semi-Hermetic Semi-Hermetic Nominal Horsepower 20 20 20 22 25 25 25 30 30 30 Number Of Cylinders Per Compressor 4 4 4 4 4 4 4 6 4 6 Oil Charge Per Compressor, Oz. 130 130 130 130 130 130 130 140 140 140 Oil Charge Per Compressor, (g) (3686) (3686) (3686) (3686) (3686) (3686) (3686) (3969) (3969) (3969) CAPACITY REDUCTION STEPS - PERCENT OF COMPRESSOR DISPLACEMENT Standard Staging - Circuit #1 in Lead Standard 4 Stages 0-25-50-75-100 0-22-50-72-100 0-25-50-75-100 0-21-60-81-100 0-23-59-82-100 Standard Staging - Circuit #2 in Lead Standard 4 Stages 0-25-50-75-100 0-28-50-78-100 0-25-50-75-100 0-39-60-79-100 0-36-59-77-100 Optional Staging - Circuit #1 in Lead Optional 6 Stages N/A N/A N/A N/A N/A Optional Staging - Circuit #2 in Lead Optional 6 Stages N/A N/A N/A N/A N/A CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING Coil Face Area,Sq. Ft. 28.3 28.3 28.3 28.3 28.3 28.3 43.1 43.1 43.1 43.1 Coil Face Area, (M 2 ) (2.6) (2.6) (2.6) (2.6) (2.6) (2.6) (4) (4) (4) (4) Finned Height x Finned Length, In. 40 x 102 40 x 102 40 x 102 40 x 102 40 x 102 40 x 102 40 x 155 40 x 155 40 x 155 40 x 155 Finned Height x Finned Length, (mm) 2591) 2591) 2591) 2591) 2591) 2591) 3937) 3937) 3937) 3937) Fins Per Inch x Rows Deep 16 x 2 16 x 2 16 x 2 16 x 2 16 x 3 16 x 3 16 x 2 16 x 2 16 x 2 16 x 2 Maximum Relief Valve Pressure Setting, psig (kpa) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) CONDENSER FANS - DIRECT DRIVE PROPELLER TYPE Number Of Fans - Fan Diameter, In. (mm) 4-26 (660) 4-26 (660) 4-26 (660) 6-26 (660) 6-26 (660) Number Of Motors - HP (kw) 4-1.0 (.7) 4-1.0 (.7) 4-1.0 (.7) 6-1.0 (.7) 6-1.0 (.7) Fan And Motor RPM, 60/50Hz 1100/915 1100/915 1100/915 1100/915 1100/915 60 Hz Fan Tip Speed, FPM 7760 7760 7760 7760 7760 60 Hz Total Unit Airflow, CFM 28400 29840 26980 42000 42000 DIRECT EXPANSION EVAPORATOR - BAFFLED SHELL AND THRU-TUBE Diameter, in. - Length, Ft. 10-08 10-08 10-08 10-08 12-08 Diameter, (mm) - Length, (mm) (254-2439) (254-2439) (254-2439) (254-2439) (305-2439) Water Volume, Gallons, (L) 17.90 (67.8) 17.90 (67.8) 17.90 (67.8) 17.90 (67.8) 24.30 (92) Maximum Water Pressure, psig (kpa) 175 (1207) 175 (1207) 175 (1207) 175 (1207) 175 (1207) Maximum Refrigerant Working Pressure, psig 225 (1552) 225 (1552) 225 (1552) 225 (1552) 225 (1552) (kpa) Water Inlet / Outlet Victaulic Connections, 4 (101.6) 4 (101.6) 4 (101.6) 4 (101.6) 5 (127) In. (mm) Drain - NPT int, In. (mm).375 (9.5).375 (9.5).375 (9.5).375 (9.5).375 (9.5) Vent - NPT int, In. (mm).375 (9.5).375 (9.5).375 (9.5).375 (9.5).375 (9.5) NOTE: 1. Nominal capacity based on 95F ambient air and 54F/44F water range. 12 IM 676

Table 8, Physical data ALR055E Through 075E PHYSICAL DATA ALR MODEL NUMBER 055E 060E 065E 070E 075E BASIC DATA Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Unit Capacity @ ARI Conditions (1), Tons (kw) 54.6 (192.0) 59.6 (209.6) 64.0 (225.0) 69.0 (242.6) 72.2 (253.9) Number Of Refrigerant Circuits 2 2 2 2 2 Unit Operating Charge, R-22, Lb. 45 45 45 45 45 45 58 58 60 60 Unit Operating Charge, R-22, (kg) (15.9) (15.9) (15.9) (15.9) (18.1) (18.1) (18.1) (18.1) (20.4) (20.4) Cabinet Dimensions, LxWxH, In. 176 x 83 x 59 176 x 83 x 59 176 x 83 x 59 229 x 83 x 59 229 x 83 x 59 Cabinet Dimensions, LxWxH, (mm) (4470 x 2108 x 1499) (4470 x 2108 x 1499) (4470 x 2108 x 1499) (5817 x 2108 x 1499) (5817 x 2108 x 1499) Unit Operating Weight, Lb. (kg) 4910 (2228) 5052 (2292) 5148 (2335) 5900 (2677) 5950 (2700) Unit Shipping Weight, Lb. (kg) 4760 (2160) 4850 (2200) 4946 (2244) 5635 (2556) 5685 (2579) Add'l Weight If Copper Finned Coils, Lb. (kg) 410 (186) 615 (279) 615 (279) 825 (374) 825 (374) COMPRESSORS Type Semi-Hermetic Semi-Hermetic Semi-Hermetic Semi-Hermetic Semi-Hermetic Nominal Horsepower 30 30 30 35 35 35 35 40 40 40 Number Of Cylinders Per Compressor 6 6 6 6 6 6 6 6 6 6 Oil Charge Per Compressor, Oz. 140 140 140 140 140 140 140 255 255 255 Oil Charge Per Compressor, (g) (3969) (3969) (3969) (3969) (3969) (3969) (3969) (7229) (7229) (7229) CAPACITY REDUCTION STEPS - PERCENT OF COMPRESSOR DISPLACEMENT Standard Staging - Circuit #1 in Lead Standard 4 Stages 0-33-50-83-100 0-30-67-82-100 0-33-50-83-100 0-32-67-83-100 0-33-50-83-100 Standard Staging - Circuit #2 in Lead Standard 4 Stages 0-33-50-83-100 0-36-67-85-100 0-33-50-83-100 0-35-67-84-100 0-33-50-83-100 Optional Staging - Circuit #1 in Lead Optional 6 Stages 0-17-33-50-67-83- 100 0-15-33-48-67-82- 100 0-17-33-50-67-83- 100 0-16-33-49-67-83- 100 0-17-33-50-67-83- 100 Optional Staging - Circuit #2 in Lead Optional 6 Stages 0-17-33-50-67-83- 100 0-18-33-51-67-85- 100 0-17-33-50-67-83- 100 0-17-33-51-67-84- 100 0-17-33-50-67-83- 100 CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING Coil Face Area,Sq. Ft. 43.1 43.1 43.1 43.1 43.1 43.1 57.8 57.8 57.8 57.8 Coil Face Area, (M 2 ) (4) (4) (4) (4) (4) (4) (5.4) (5.4) (5.4) (5.4) Finned Height x Finned Length, In. 40 x 155 40 x 155 40 x 155 40 x 155 40 x 155 40 x 155 40 x 208 40 x 208 40 x 208 40 x 208 Finned Height x Finned Length, (mm) 3937) 3937) 3937) 3937) 3937) 3937) Fins Per Inch x Rows Deep 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 Maximum Relief Valve Pressure Setting, psig (kpa) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) CONDENSER FANS - DIRECT DRIVE PROPELLER TYPE Number Of Fans - Fan Diameter, In. (mm) 6-26 (660) 6-26 (660) 6-26 (660) 8-26 (660) 10-26 (660) Number Of Motors - HP (kw) 6-1.0 (.7) 6-1.0 (.7) 6-1.0 (.7) 8-1.0 (.7) 10-1.0 (.7) Fan And Motor RPM, 60/50Hz 1100/915 1100/915 1100/915 1100/915 1100/915 60 Hz Fan Tip Speed, FPM 7760 7760 7760 7760 7760 60 Hz Total Unit Airflow, CFM 38250 38250 38250 51000 58000 DIRECT EXPANSION EVAPORATOR - BAFFLED SHELL AND THRU-TUBE Diameter, in. - Length, Ft. 12-08 12-08 12-08 12-08 12-08 Diameter, (mm) - Length, (mm) (305-2439) (305-2439) (305-2439) (305-2439) (305-2439) Water Volume, Gallons, (L) 24.30 (92) 24.30 (92) 24.30 (92) 24.30 (92) 24.30 (92) Maximum Water Pressure, psig (kpa) 175 (1207) 175 (1207) 175 (1207) 175 (1207) 175 (1207) Maximum Refrigerant Working Pressure, psig 225 (1552) 225 (1552) 225 (1552) 225 (1552) 225 (1552) (kpa) Water Inlet / Outlet Victaulic Connections, 5 (127) 5 (127) 5 (127) 5 (127) 5 (127) In. (mm) Drain - NPT int, In. (mm).375 (9.5).375 (9.5).375 (9.5).375 (9.5).375 (9.5) Vent - NPT int, In. (mm).375 (9.5).375 (9.5).375 (9.5).375 (9.5).375 (9.5) NOTE: 1. Nominal capacity based on 95F ambient air and 54F/44F water range. IM 676 13

Table 9, Physical data ALR080E Through 100E PHYSICAL DATA ALR MODEL NUMBER 080E 085E 090E 100E BASIC DATA Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Unit Capacity @ ARI Conditions (1), Tons (kw) 81.3 (285.9) 85.3 (300.0) 92.7 (326.0) 99.2 (348.8) Number Of Refrigerant Circuits 2 2 2 2 Unit Operating Charge, R-22, Lb. 62 62 65 65 65 65 68 68 Unit Operating Charge, R-22, (kg) (22.7) (22.7) (22.7) (22.7) (24.9) (24.9) (24.9) (24.9) Cabinet Dimensions, LxWxH, In. 229 x 83 x 59 229 x 83 x 59 229 x 83 x 59 229 x 83 x 59 Cabinet Dimensions, LxWxH, (mm) (5817 x 2108 x 1499) (5817 x 2108 x 1499) (5817 x 2108 x 1499) (5817 x 2108 x 1499) Unit Operating Weight, Lbs. (kg) 7055 (3200) 7680 (3484) 7685 (3486) 7830 (3552) Unit Shipping Weight, Lbs. (kg) 6685 (3032) 7310 (3316) 7315 (3318) 7535 (3418) Add'l Weight If Copper Finned Coils, Lb. (kg) 826 (375) 826 (375) 826 (375) 826 (375) COMPRESSORS Type Semi-Hermetic Semi-Hermetic Semi-Hermetic Semi-Hermetic Nominal Horsepower 25-25 25-25 25-25 30-25 30-25 30-25 30-30 30-30 Number Of Cylinders Per Compressor 4-4 4-4 4-4 4-4 6-4 6-4 6-4 6-4 Oil Charge Per Compressor, Oz. 130-130 130-130 130-130 140-130 140-130 140-130 140-140 140-140 Oil Charge Per Compressor, (g) (3686-3686) (3686-3686) CAPACITY REDUCTION STEPS - PERCENT OF COMPRESSOR DISPLACEMENT Standard Staging - Circuit #1 in Lead Standard 6 Stages 0-13-25-38-50-75-100 0-12-24-36-48-72-100 0-19-39-48-58-79-100 0-18-36-45-54-76-100 Standard Staging - Circuit #2 in Lead Standard 6 Stages 0-13-25-38-50-75-100 0-12-24-36-48-76-100 0-19-39-48-58-79-100 0-18-36-45-54-76-100 (3686-3686) (3969-3686) (3969-3686) (3969-3686) (3969-3969) (3969-3969) Optional Staging - Circuit #1 in Lead Optional 8 Stages 0-13-25-38-50 0-12-24-36-48 0-19-39-48-58 0-18-36-45-76-63-75-88-100-60-76-88-100-69-81-90-100-68-82-91-100 Optional Staging - Circuit #2 in Lead Optional 8 Stages 0-13-25-38-50 0-12-24-36-48 0-19-39-48-58 0-18-36-45-76-63-75-88-100-64-76-88-100-69-81-90-100-68-82-91-100 CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING Coil Face Area,Sq. Ft. 57.8 57.8 57.8 57.8 57.8 57.8 57.8 57.8 Coil Face Area, (M 2 ) (5.4) (5.4) (5.4) (5.4) (5.4) (5.4) (5.4) (5.4) Finned Height x Finned Length, In. 40 x 208 40 x 208 40 x 208 40 x 208 40 x 208 40 x 208 40 x 208 40 x 208 Finned Height x Finned Length, (mm) Fins Per Inch x Rows Deep 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 Maximum Relief Valve Pressure Setting, psig (kpa) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) CONDENSER FANS - DIRECT DRIVE PROPELLER TYPE Number Of Fans - Fan Diameter, In. (mm) 10-26 (660) 10-26 (660) 10-26 (660) 10-26 (660) Number Of Motors - HP (kw) 10-1.0 (.7) 10-1.0 (.7) 10-1.0 (.7) 10-1.0 (.7) Fan And Motor RPM, 60/50Hz 1100/915 1100/915 1100/915 1100/915 60 Hz Fan Tip Speed, FPM 7760 7760 7760 7760 60 Hz Total Unit Airflow, CFM 58000 58000 58000 58000 DIRECT EXPANSION EVAPORATOR - BAFFLED SHELL AND THRU-TUBE Diameter, in. - Length, Ft. 12-08 14-10 14-10 14-10 Diameter, (mm) - Length, (mm) (305-2439) (356-3048) (356-3048) (356-3048) Water Volume, Gallons, (L) 24.30 (92) 36.10 (136.6) 36.10 (136.6) 36.10 (136.6) Maximum Water Pressure, psig (kpa) 175 (1207) 175 (1207) 175 (1207) 175 (1207) Maximum Refrigerant Working Pressure, psig (kpa) 225 (1552) 225 (1552) 225 (1552) 225 (1552) Water Inlet / Outlet Victaulic Connections, In. (mm) 5 (127) 6 (152.4) 6 (152.4) 6 (152.4) Drain - NPT int, In. (mm).375 (9.5).375 (9.5).375 (9.5).375 (9.5) Vent - NPT int, In. (mm).375 (9.5).375 (9.5).375 (9.5).375 (9.5) NOTE: 1. Nominal capacity based on 95F ambient air and 54F/44F water range. 14 IM 676

Table 10, Physical data ALR100E Through 135E PHYSICAL DATA ALR MODEL NUMBER 110E 120E 130E 135E BASIC DATA Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Unit Capacity @ ARI Conditions (1), Tons (kw) 107.8 (379.0) 120.7 (424.4) 130.6 (459.2) 135.5 (476.4) Number Of Refrigerant Circuits 2 2 2 2 Unit Operating Charge, R-22, Lb. 87 87 90 90 120 120 120 120 Unit Operating Charge, R-22, (kg) (36.3) (36.3) (36.3) (36.3) (38.6) (38.6) (38.6) (38.6) Cabinet Dimensions, LxWxH, In. 229 x 83 x 89 229 x 83 x 89 229 x 83 x 93 229 x 83 x 93 Cabinet Dimensions, LxWxH, (mm) (5809 x 2118 x 2369) (5809 x 2118 x 2369) (5809 x 2118 x 2369) (5809 x 2118 x 2369) Unit Operating Weight, Lbs. (kg) 8800 (3992) 9200 (4173) 9800 (4445) 10160 (4609) Unit Shipping Weight, Lbs. (kg) 8505 (3858) 8760 (3974) 9350 (4241) 9735 (4416) Add'l Weight If Copper Finned Coils, Lbs. (kg) 1105 (501) 1105 (501) 1652 (750) 1652 (750) COMPRESSORS Type Semi-Hermetic Semi-Hermetic Semi-Hermetic Semi-Hermetic Nominal Horsepower 30-30 30-35 30-35 35-35 35-35 35-35 35-40 35-40 Number Of Cylinders Per Compressor 6-6 6-6 6-6 6-6 6-6 6-6 6-6 6-6 Oil Charge Per Compressor, Oz. 140-140 140-140 140-140 140-140 140-140 140-140 140-255 140-255 Oil Charge Per Compressor, (g) (3969-3969) (3969-3969) CAPACITY REDUCTION STEPS - PERCENT OF COMPRESSOR DISPLACEMENT Standard Staging - Circuit #1 in Lead Standard 6 Stages 0-16-32-40-48-71-100 0-15-32-39-48-74-100 0-17-33-42-50-75-100 0-16-32-40-48-74-100 (3969-3969) (3969-3969) (3969-3969) (3969-3969) (3969-7229) (3969-7229) Standard Staging - Circuit #2 in Lead Standard 6 Stages 0-16-32-40-48-76-100 0-17-32-41-48-76-100 0-17-33-42-50-75-100 0-16-32-40-48-74-100 Optional Staging - Circuit #1 in Lead Optional 8 Stages 0-16-32-40-48 0-15-32-39-48 0-17-33-42-50 0-16-32-40-48-64-84-92-100-67-84-91-100-67-83-92-100-66-84-92-100 Optional Staging - Circuit #2 in Lead Optional 8 Stages 0-16-32-40-48 0-17-32-41-48 0-17-33-42-50 0-16-32-40-48 CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING -68-84-92-100 -65-84-91-100 -67-83-92-100 -66-84-92-100 Coil Face Area,Sq. Ft. 115.6 115.6 115.6 115.6 115.6 115.6 115.6 115.6 Coil Face Area, (M 2 ) (10.3) (10.3) (10.3) (10.3) (10.3) (10.3) (10.3) (10.3) Finned Height x Finned Length, In. 80 x 208 80 x 208 80 x 208 80 x 208 80 x 208 80 x 208 80 x 208 80 x 208 Finned Height x Finned Length, (mm) (2032 x (2032 x (2032 x (2032 x (2032 x (2032 x (2032 x (2032 x Fins Per Inch x Rows Deep 16 x 2 16 x 2 16 x 2 16 x 2 16 x 3 16 x 3 16 x 3 16 x 3 Maximum Relief Valve Pressure Setting, psig (kpa) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) CONDENSER FANS - DIRECT DRIVE PROPELLER TYPE Number Of Fans - Fan Diameter, In. (mm) 10-28 (711) 10-28 (711) 12-28 (711) 12-28 (711) Number Of Motors - HP (kw) 10-1.5 (1.1) 10-1.5 (1.1) 12-1.5 (1.1) 12-1.5 (1.1) Fan And Motor RPM, 60/50Hz 1100/915 1100/915 1100/915 1100/915 60 Hz Fan Tip Speed, FPM 8063 8063 8063 8063 60 Hz Total Unit Airflow, CFM 94710 94710 108240 108240 DIRECT EXPANSION EVAPORATOR - BAFFLED SHELL AND THRU-TUBE Diameter, in. - Length, Ft. 14-10 16-10 16-10 16-10 Diameter, (mm) - Length, (mm) (356-3048) (406-3048) (406-3048) (406-3048) Water Volume, Gallons, (L) 36.10 (136.6) 43.6 (165) 43.6 (165) 43.6 (165) Maximum Water Pressure, psig (kpa) 175 (1207) 175 (1207) 175 (1207) 175 (1207) Maximum Refrigerant Working Pressure, psig (kpa) 225 (1552) 225 (1552) 225 (1552) 225 (1552) Water Inlet / Outlet Victaulic Connections, In. (mm) 6 (152.4) 6 (152.4) 6 (152.4) 6 (152.4) Drain - NPT int, In. (mm).375 (9.5).375 (9.5).375 (9.5).375 (9.5) Vent - NPT int, In. (mm).375 (9.5).375 (9.5).375 (9.5).375 (9.5) NOTE: 1. Nominal capacity based on 95F ambient air and 54F/44F water range. IM 676 15

Table 11, Physical data ALR140E Through 160E PHYSICAL DATA ALR MODEL NUMBER 140E 145E 150E 160E BASIC DATA Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Unit Capacity @ ARI Conditions (1), Tons (kw) 139.7 (491.2) 144.7 (508.8) 149.9 (527.0) 157.8 (554.8) Number Of Refrigerant Circuits 2 2 2 2 Unit Operating Charge, R-22, Lbs 125 125 130 130 130 130 140 140 Unit Operating Charge, R-22, (kg) (45.4) (45.4) (45.4) (45.4) (45.4) (45.4) (49.9) (49.9) Cabinet Dimensions, LxWxH, In. 229 x 83 x 93 229 x 83 x 93 229 x 83 x 93 263 x 83 x 93 Cabinet Dimensions, LxWxH, (mm) (5809 x 2118 x 2369) (5809 x 2118 x 2369) (5809 x 2118 x 2369) (6690 x 2118 x 2369) Unit Operating Weight, Lbs. (kg) 10440 (4736) 10690 (4849) 10850 (4922) 11515 (5223) Unit Shipping Weight, Lbs. (kg) 10040 (4554) 10290 (4668) 10450 (4740) 11115 (5042) Add'l Weight If Copper Finned Coils, Lb. (kg) 1652 (750) 1652 (750) 1652 (750) 1930 (876) COMPRESSORS Type Semi-Hermetic Semi-Hermetic Semi-Hermetic Semi-Hermetic Nominal Horsepower 40-40 40-40 40-40 40-40 40-40 40-50 40-50 40-50 Number Of Cylinders Per Compressor 6-6 6-6 6-6 6-6 6-6 6-8 6-8 6-8 Oil Charge Per Compressor, Oz. 255-255 255-255 255-255 255-255 255-255 255-255 255-255 255-255 Oil Charge Per Compressor, (g) (7229-7229) (7229-7229) CAPACITY REDUCTION STEPS - PERCENT OF COMPRESSOR DISPLACEMENT Standard Staging - Circuit #1 in Lead Standard 6 Stages (N/A on MicroTech Units) 0-17-33-42-50-75-100 0-17-33-42-50-75-100 0-15-32-40-48-72-100 0-17-33-42-50-77-100 (7229-7229) (7229-7229) (7229-7229) (7229-7229) (7229-7229) (7229-7229) Standard Staging - Circuit #2 in Lead Standard 6 Stages (N/A on MicroTech Units) 0-17-33-42-50-75-100 0-17-33-42-50-75-100 0-15-32-40-48-76-100 0-17-33-42-50-77-100 Optional Staging - Circuit #1 in Lead Optional 8 Stages (Std. on MicroTech Units) 0-17-33-42-50 0-17-33-42-50 0-15-32-40-64 0-17-33-42-50-67-83-92-100-67-83-92-100-64-84-92-100-63-71-86-100 Optional Staging - Circuit #2 in Lead Optional 8 Stages (Std. on MicroTech Units) 0-17-33-42-50 0-17-33-42-50 0-15-32-40-48 0-17-33-42-50 CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING -67-83-92-100 -67-83-92-100 -68-84-92-100 -63-71-86-100 Coil Face Area,Sq. Ft. 115.6 115.6 115.6 115.6 115.6 115.6 135 135 Coil Face Area, (M 2 ) (10.3) (10.3) (10.3) (10.3) (10.3) (10.3) (12.5) (12.5) Finned Height x Finned Length, In. 80 x 208 80 x 208 80 x 208 80 x 208 80 x 208 80 x 208 80 x 243 80 x 243 Finned Height x Finned Length, (mm) (2032 x (2032 x (2032 x (2032 x (2032 x (2032 x (2032 x 6172) (2032 x 6172) Fins Per Inch x Rows Deep 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 Maximum Relief Valve Pressure Setting, psig (kpa) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) CONDENSER FANS - DIRECT DRIVE PROPELLER TYPE Number Of Fans - Fan Diameter, In. (mm) 12-28 (711) 12-28 (711) 12-28 (711) 14-28 (711) Number Of Motors - HP (kw) 12-1.5 (1.1) 12-1.5 (1.1) 12-1.5 (1.1) 14-1.5 (1.1) Fan And Motor RPM, 60/50Hz 1100/915 1100/915 1100/915 1100/915 60 Hz Fan Tip Speed, FPM 8063 8063 8063 8063 60 Hz Total Unit Airflow, CFM 108240 108240 108240 126280 DIRECT EXPANSION EVAPORATOR - BAFFLED SHELL AND THRU-TUBE Diameter, in. - Length, Ft. 16-10 18-10 18-10 18-10 Diameter, (mm) - Length, (mm) (406-3048) (457-3048) (457-3048) (457-3048) Water Volume, Gallons, (L) 43.6 (165) 57.30 (216.9) 57.30 (216.9) 57.30 (216.9) Maximum Water Pressure, psig (kpa) 175 (1207) 175 (1207) 175 (1207) 175 (1207) Maximum Refrigerant Working Pressure, psig (kpa) 225 (1552) 225 (1552) 225 (1552) 225 (1552) Water Inlet / Outlet Victaulic Connections, In. (mm) 6 (152.4) 6 (152.4) 6 (152.4) 6 (152.4) Drain - NPT int, In. (mm) 0.375 (9.5) 0.375 (9.5) 0.375 (9.5) 0.375 (9.5) Vent - NPT int, In. (mm) 0.375 (9.5) 0.375 (9.5) 0.375 (9.5) 0.375 (9.5) NOTE: 1. Nominal capacity based on 95F ambient air and 54F/44F water range. 16 IM 676

Table 12, Physical data ALR170E Through 185E PHYSICAL DATA ALR MODEL NUMBER 170E 180E 185E BASIC DATA Ckt.1 Ckt.2 Ckt.1 Ckt.2 Ckt.1 Ckt.2 Unit Capacity @ ARI Conditions (1), Tons (kw) 167.2 (587.9) 177.3 (623.4) 185.8 (653.3) Number Of Refrigerant Circuits 2 2 2 Unit Operating Charge, R-22, Lb. 140 140 145 145 145 145 Unit Operating Charge, R-22, (kg) (52.2) (52.2) (54.4) (54.4) (54.4) (54.4) Cabinet Dimensions, LxWxH, In. 263 x 83 x 93 263 x 83 x 93 263 x 83 x 93 Cabinet Dimensions, LxWxH, (mm) (6690 x 2118 x 2369) (6690 x 2118 x 2369) (6690 x 2118 x 2369) Unit Operating Weight, Lbs. (kg) 11805 (5355) 11805 (5355) 11805 (5355) Unit Shipping Weight, Lbs. (kg) 11405 (5174) 11405 (5174) 11405 (5174) Add'l Weight If Copper Finned Coils, Lb. (kg) 1930 (876) 1930 (876) 1930 (876) COMPRESSORS Type Semi-Hermetic Semi-Hermetic Semi-Hermetic Nominal Horsepower 50-50 50-50 50-60 50-60 60-60 60-60 Number Of Cylinders Per Compressor 8-8 8-8 8-8 8-8 8-8 8-8 Oil Charge Per Compressor, Oz. 255-255 255-255 255-255 255-255 255-255 255-255 Oil Charge Per Compressor, (g) (7229-7229) (7229-7229) CAPACITY REDUCTION STEPS - PERCENT OF COMPRESSOR DISPLACEMENT (7229-7229) (7229-7229) (7229-7229) (7229-7229) Standard Staging - Circuit #1 in Lead Standard 6 Stages (N/A on MicroTech Units) 0-19-37-44-50-75-100 0-17-34-40-46-73-100 0-19-37-44-50-75-100 Standard Staging - Circuit #2 in Lead Standard 6 Stages (N/A on MicroTech Units) 0-19-37-44-50-75-100 0-17-34-40-46-73-100 0-19-37-44-50-75-100 Optional Staging - Circuit #1 in Lead Optional 8 Stages (Std. on MicroTech Units) 0-19-37-44-50 0-17-34-40-46 0-19-37-44-50-62-75-87-100-67-89-94-100-62-75-87-100 Optional Staging - Circuit #2 in Lead Optional 8 Stages (Std. on MicroTech Units) 0-19-37-44-50 0-17-34-40-46 0-19-37-44-50 CONDENSERS - HIGH EFFICIENCY FIN AND TUBE TYPE WITH INTEGRAL SUBCOOLING -62-75-87-100 -67-89-94-100 -62-75-87-100 Coil Face Area,Sq. Ft. 135 135 135 135 135 135 Coil Face Area, (M 2 ) (12.5) (12.5) (12.5) (12.5) (12.5) (12.5) Finned Height x Finned Length, In. 80 x 243 80 x 243 80 x 243 80 x 243 80 x 243 80 x 243 Finned Height x Finned Length, (mm) (2032 x 6172) (2032 x 6172) (2032 x 6172) (2032 x 6172) (2032 x 6172) (2032 x 6172) Fins Per Inch x Rows Deep 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 16 x 3 Maximum Relief Valve Pressure Setting, psig (kpa) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) 450 (3103) CONDENSER FANS - DIRECT DRIVE PROPELLER TYPE Number Of Fans - Fan Diameter, In. (mm) 14-28 (711) 14-28 (711) 14-28 (711) Number Of Motors - HP (kw) 14-1.5 (1.1) 14-1.5 (1.1) 14-1.5 (1.1) Fan And Motor RPM, 60/50Hz 1100/915 1100/915 1100/915 60 Hz Fan Tip Speed, FPM 8063 8063 8063 60 Hz Total Unit Airflow, CFM 126280 126280 126280 DIRECT EXPANSION EVAPORATOR - BAFFLED SHELL AND THRU-TUBE Diameter, in. - Length, Ft. 18-10 18-10 18-10 Diameter, (mm) - Length, (mm) (457-3048) (457-3048) (457-3048) Water Volume, Gallons, (L) 57.30 (216.9) 57.30 (216.9) 57.30 (216.9) Maximum Water Pressure, psig (kpa) 175 (1207) 175 (1207) 175 (1207) Maximum Refrigerant Working Pressure, psig (kpa) 225 (1552) 225 (1552) 225 (1552) Water Inlet / Outlet Victaulic Connections, In. (mm) 6 (152.4) 6 (152.4) 6 (152.4) Drain - NPT int, In. (mm).375 (9.5).375 (9.5).375 (9.5) Vent - NPT int, In. (mm).375 (9.5).375 (9.5).375 (9.5) NOTE: 1. Nominal capacity based on 95F ambient air and 54F/44F water range. IM 676 17

Electrical Data Field Wiring CAUTION Internal power wiring to the compressors for single and multiple point option are different. Field wiring must be installed according to unit wiring diagram. Wiring must comply with all applicable codes and ordinances. Warranty is void if wiring is not in accordance with specifications. Copper wire is required for all power lead terminations at the unit. Aluminum or copper can be used for all other wiring. ALR units may be ordered with internal power wiring for either single or multiple point power connection. If single point power connection is ordered, a single large power terminal block is provided and wiring within the unit is sized in accordance with the National Electrical Code. A single field supplied fused disconnect is required. An optional factory mounted transformer may be installed. If multiple point power wiring is ordered, three power connections, one per compressor circuit, one for condenser fans, and control circuit, are required. Separate field supplied fused disconnects are required for each of the three circuits. A single power block is provided for all of the condenser fans and the optional 115V control transformer. If the evaporator heater is on a separate disconnect switch from the main unit power supply, the unit may be shut down without defeating the freeze protection provided by the cooler heater. 18 IM 676

Table 13, 032E - 070E Electrical Data Single Point Minimum POWER SUPPLY FIELD FUSE SIZE ALR Circuit Field Wire Hub Unit Volts HZ. Ampacity Wire Nominal Recommended Maximum Size (MCA) Quantity Gauge Quantity Size 208 151 3 2/0 1 1.50 175 200 230 151 3 2/0 1 1.50 175 200 032E 460 60 76 3 4 1 1.00 90 100 575 58 3 6 1 1.00 70 80 208 151 3 2/0 1 1.50 175 200 230 151 3 2/0 1 1.50 175 200 035E 460 60 76 3 4 1 1.00 90 100 575 61 3 6 1 1.00 70 80 208 183 3 3/0 1 2.00 225 250 230 183 3 3/0 1 2.00 225 250 040E 460 60 92 3 3 1 1.25 110 125 575 79 3 4 1 1.00 90 100 208 217 3 4/0 1 2.00 250 300 230 217 3 4/0 1 2.00 250 300 045E 460 60 108 3 2 1 1.25 125 150 575 89 3 3 1 1.25 110 125 208 228 3 4/0 1 2.00 300 300 230 228 3 4/0 1 2.00 300 300 050E 460 60 113 3 2 1 1.25 150 150 575 94 3 3 1 1.25 110 125 208 238 3 250 1 2.50 300 300 230 238 3 250 1 2.50 300 300 055E 460 60 118 3 1 1 1.25 150 150 575 94 3 3 1 1.25 110 125 208 270 3 300 1 2.50 350 350 230 259 3 300 1 2.50 300 350 060E 460 60 134 3 1/0 1 1.50 175 175 575 102 3 2 1 1.25 125 125 208 296 3 350 1 2.50 350 400 230 276 3 300 1 2.50 350 350 065E 460 60 147 3 1/0 1 1.50 175 200 575 108 3 2 1 1.25 125 150 208 322 3 400 1 3.00 (76) 400 450 230 303 3 350 1 2.50 350 400 070E 460 60 156 3 2/0 1 1.50 200 200 575 120 3 1 1 1.25 150 150 208 344 3 500 1 3.00 (76) 400 450 230 326 3 400 1 3.00 (76) 400 450 075E 460 60 164 3 2/0 1 1.50 200 225 575 130 3 1 1 1.25 150 175 See page 33 for all Electrical Data notes. IM 676 19

Table 14, 080E - 135E Electrical Data Single Point Minimum POWER SUPPLY FIELD FUSE SIZE ALR Circuit Field Wire Hub Unit Volts HZ. Ampacity Wire Nominal Recommended Maximum Size (MCA) Quantity Gauge Quantity Size 208 355 3 500 1 3.00 (76) 400 400 230 355 3 500 1 3.00 (76) 400 400 080E 460 60 177 3 3/0 1 2.00 200 200 575 154 3 2/0 1 1.50 175 175 208 368 3 500 1 3.00 (76) 400 450 230 368 3 500 1 3.00 (76) 400 450 085E 460 60 184 3 3/0 1 2.00 200 225 575 160 3 2/0 1 1.50 175 175 208 402 6 250 1 3.00 (76) 450 450 230 402 6 250 1 3.00 (76) 450 450 090E 460 60 200 3 3/0 1 2.00 225 225 575 165 3 2/0 1 1.50 200 200 208 424 6 300 1 4.00 (102) 450 500 230 424 6 300 1 4.00 (102) 450 500 100E 460 60 210 3 4/0 1 2.00 225 250 575 175 3 2/0 1 1.50 200 200 208 494 6 350 1 4.00 (102) 600 600 230 483 6 350 1 4.00 (102) 600 500 110E 460 60 244 3 250 1 2.50 300 300 575 184 3 3/0 1 2.00 200 225 208 547 6 500 1 4.00 (102) 600 600 230 517 6 400 1 4.00 (102) 600 600 120E 460 60 270 3 300 1 2.50 300 300 575 196 3 3/0 1 2.00 225 225 208 584 6 500 1 4.00 (102) 700 700 230 546 6 500 1 4.00 (102) 600 600 130E 460 60 289 3 350 1 2.50 300 300 575 206 3 4/0 1 2.00 225 225 208 615 6 350 2 2.50 700 700 230 579 6 350 2 2.50 700 700 135E 460 60 298 3 350 1 2.50 350 350 575 220 3 300 1 2.00 250 250 See page 33 for all Electrical Data notes. 20 IM 676

Table 15, 140E - 185E Electrical Data Single Point Minimum POWER SUPPLY FIELD FUSE SIZE ALR Circuit Field Wire Hub Unit Volts HZ. Ampacity Wire Nominal Recommended Maximum Size (MCA) Quantity Gauge Quantity Size 208 643 6 500 2 3.00 (76) 700 700 230 609 6 500 2 3.00 (76) 700 700 140E 460 60 306 3 350 1 2.50 350 350 575 232 3 250 1 2.50 250 250 208 643 6 500 2 3.00 (76) 700 700 230 609 6 500 2 3.00 (76) 700 700 145E 460 60 306 3 350 1 2.50 350 350 575 232 3 250 1 2.50 250 250 208 677 6 500 2 3.00 (76) 800 800 230 653 6 500 2 3.00 (76) 800 800 150E 460 60 328 3 400 1 3.00 (76) 350 450 575 257 3 300 1 2.50 300 300 208 716 6 500 2 3.00 (76) 800 800 230 700 6 500 2 3.00 (76) 800 800 160E 460 60 352 3 500 1 3.00 (76) 400 400 575 281 3 300 1 2.50 300 300 208 770 6 600 2 3.00 (76) 800 800 230 770 6 600 2 3.00 (76) 800 800 170E 460 60 388 3 600 1 3.00 (76) 450 450 575 321 3 400 1 3.00 (76) 350 350 208 860 12 300 2 4.0 (102) 1000 1000 230 860 12 300 2 4.0 (102) 1000 1000 180E 460 60 413 3 600 1 3.00 (76) 500 500 575 337 3 500 1 3.00 (76) 400 400 208 940 12 350 2 4.0 (102) 1000 1000 230 940 12 350 2 4.0 (102) 1000 1000 185E 460 60 435 6 300 1 3.00 (76) 500 500 575 351 3 500 1 3.00 (76) 400 400 See page 33 for all Electrical Data notes. IM 676 21

Table 16, 032E - 075E Electrical Data Multiple Point Electrical Circuit #1 - Fans and Transformer Electrical Circuit #2 - Compressor Circuit #1 Electrical Circuit #3 - Compressor Circuit #2 ALR Min. Power Supply Field Fusing Min. Power Supply Field Fusing Min. Power Supply Field Fusing Unit Volts HZ. Circuit Field Wire Hub Rec. Max. Circuit Field Wire Hub Rec. Max. Circuit Field Wire Hub Rec. Max. Size Amps Wire Hub Fuse Fuse Amps Wire Hub Fuse Fus e Amps Wire Hub Fuse Fuse (MCA) Qty. Gauge Qty. Size Size Size (MCA) Qty. Gauge Qty. Size Size Size (MCA) Qty. Gaug e Qty. Size Size Size 208 17 3 12 1 1.00 20 20 75 3 4 1 2.00 100 125 75 3 4 1 2.00 100 125 230 17 3 12 1 1.00 20 20 75 3 4 1 2.00 100 125 75 3 4 1 2.00 100 125 032E 460 60 8.5 3 14 1.75 15 15 38 3 8 1 1.25 50 60 38 3 8 1 1.25 50 60 (19) 575 9.4 3 14 1.75 15 15 28 3 10 1 1.00 35 45 28 3 10 1 1.00 35 45 (19) 208 17 3 12 1 1.00 20 20 75 3 4 1 2.00 100 125 75 3 4 1 2.00 100 125 230 17 3 12 1 1.00 20 20 75 3 4 1 2.00 100 125 75 3 4 1 2.00 100 125 035E 460 60 8.5 3 14 1.75 15 15 38 3 8 1 1.25 50 60 38 3 8 1 1.25 50 60 (19) 575 9.4 3 14 1.75 15 15 28 3 10 1 1.00 35 45 30 3 10 1 1.00 40 50 (19) 208 17 3 12 1 1.00 20 20 93 3 3 1 2.00 125 150 93 3 3 1 2.00 125 150 230 17 3 12 1 1.00 20 20 93 3 3 1 2.00 125 150 93 3 3 1 2.00 125 150 040E 460 60 8.5 3 14 1.75 15 15 47 3 8 1 1.25 60 80 47 3 8 1 1.25 60 80 (19) 575 9.4 3 14 1.75 15 15 39 3 8 1 1.25 50 60 39 3 8 1 1.25 50 60 (19) 208 25 3 12 1 1.00 25 25 93 3 3 1 2.00 125 150 119 3 1 1 2.00 150 200 230 25 3 12 1 1.00 25 25 93 3 3 1 2.00 125 150 119 3 1 1 2.00 150 200 045E 460 60 12.5 3 14 1.75 15 15 47 3 8 1 1.25 60 80 59 3 6 1 1.50 80 100 (19) 575 13.8 3 14 1.75 15 15 39 3 8 1 1.25 50 60 45 3 8 1 1.25 60 80 (19) 208 25 3 12 1 1.00 25 25 107 3 2 1 2.00 150 175 119 3 1 1 2.00 150 200 230 25 3 12 1 1.00 25 25 107 3 2 1 2.00 150 175 119 3 1 1 2.00 150 200 050E 460 60 12.5 3 14 1.75 15 15 53 3 6 1 1.50 70 90 59 3 6 1 1.50 80 100 (19) 575 13.8 3 14 1.75 15 15 45 3 8 1 1.25 60 80 45 3 8 1 1.25 60 80 (19) 208 25 3 12 1 1.00 25 25 119 3 1 1 2.00 150 200 119 3 1 1 2.00 150 200 230 25 3 12 1 1.00 25 25 119 3 1 1 2.00 150 200 119 3 1 1 2.00 150 200 055E 460 60 12.5 3 14 1.75 15 15 59 3 6 1 1.50 80 100 59 3 6 1 1.50 80 100 (19) 575 13.8 3 14 1.75 15 15 45 3 8 1 1.25 60 80 45 3 8 1 1.25 60 80 (19) 208 25 3 12 1 1.00 25 25 119 3 1 1 2.00 150 200 152 3 2/0 1 1.50 200 250 230 25 3 12 1 1.00 25 25 119 3 1 1 2.00 150 200 140 3 1/0 1 1.50 200 250 060E 460 60 12.5 3 14 1.75 15 15 59 3 6 1 1.50 80 100 75 3 4 1 2.00 100 125 (19) 575 13.8 3 14 1.75 (19) 15 15 45 3 8 1 1.25 60 80 53 3 6 1 1.50 70 90 See page 33 for all Electrical Data notes. 22 IM 676

Table 17, 032E - 075E Electrical Data Multiple Point (continued) Electrical Circuit #1 - Fans and Transformer Electrical Circuit #2 - Compressor Circuit #1 Electrical Circuit #3 - Compressor Circuit #2 ALR Min. Power Supply Field Fusing Min. Power Supply Field Fusing Min. Power Supply Field Fusing Unit Volts HZ. Circuit Field Wire Hub Rec. Max. Circuit Field Wire Hub Rec. Max. Circuit Field Wire Hub Rec. Max. Size Amps Wire Hub Fuse Fuse Amps Wire Hub Fuse Fuse Amps Wire Hub Fuse Fuse (MCA) Qty. Gauge Qty. Size Size Size (MCA) Qty. Gauge Qty. Size Size Size (MCA) Qty. Gauge Qty. Size Size Size 208 25 3 12 1 1.00 230 25 3 12 1 1.00 065E 460 60 12.5 3 14 1.75 (19) 575 13.8 3 14 1.75 (19) 208 33 3 10 1 1.00 230 33 3 10 1 1.00 070E 460 60 16.5 3 12 1 1.00 575 18.1 3 12 1 1.00 208 41 3 8 1 1.25 230 41 3 8 1 1.25 075E 460 60 21 3 12 1 1.00 575 23 3 12 1 1.00 25 25 152 3 2/0 1 1.50 25 25 140 3 1/0 1 1.50 15 15 75 3 4 1 2.00 15 15 53 3 6 1 1.50 35 35 152 3 2/0 1 1.50 35 35 140 3 1/0 1 1.50 20 20 75 3 4 1 2.00 20 20 53 3 6 1 1.50 45 45 169 3 2/0 1 1.50 45 45 159 3 2/0 1 1.50 25 25 80 3 4 1 2.00 25 25 60 3 6 1 1.50 200 250 152 3 2/0 1 1.50 200 250 140 3 1/0 1 1.50 100 125 75 3 4 1 2.00 70 90 53 3 6 1 1.50 200 250 169 3 2/0 1 1.50 200 250 159 3 2/0 1 1.50 100 125 80 3 4 1 2.00 70 90 60 3 6 1 1.50 225 300 169 3 2/0 1 1.50 225 250 159 3 2/0 1 1.50 110 125 80 3 4 1 2.00 80 100 60 3 6 1 1.50 200 250 200 250 100 125 70 90 225 300 225 250 110 125 80 100 225 300 225 250 110 125 80 100 Table 18, 080E - 135E Electrical Data Multiple Point Electrical Circuit #1 - Fans and Transformer Electrical Circuit #2 - Compressor Circuit #1 Electrical Circuit #3 - Compressor Circuit #2 ALR Min. Power Supply Field Fusing Min. Power Supply Field Fusing Min. Power Supply Field Fusing Unit Volts HZ. Circuit Field Wire Hub Rec. Max. Circuit Field Wire Hub Rec. Max. Circuit Field Wire Hub Rec. Max. Size Amps Wire Hub Fuse Fuse Amps Wire Hub Fuse Fuse Amps Wire Hub Fuse Fuse (MCA) Qty. Gauge Qty. Size Size Size (MCA) Qty. Gauge Qty. Size Size Size (MCA) Qty. Gauge Qty. Size Size Size 208 41 3 8 1 1.25 230 41 3 8 1 1.25 080E 460 60 21 3 12 1 1.00 575 23 3 12 1 1.00 208 41 3 8 1 1.25 230 41 3 8 1 1.25 085E 460 60 21 3 12 1 1.00 575 23 3 12 1 1.00 208 41 3 8 1 1.25 230 41 3 8 1 1.25 090E 460 60 21 3 12 1 1.00 575 23 3 12 1 1.00 208 41 3 8 1 1.25 230 41 3 8 1 1.25 100E 460 60 21 3 12 1 1.00 575 23 3 12 1 1.00 See page 33 for all Electrical Data notes. 45 45 167 3 2/0 1 2.00 45 45 167 3 2/0 1 2.00 25 25 84 3 4 1 1.00 25 25 70 3 4 1 1.00 45 45 167 3 2/0 1 2.00 45 45 167 3 2/0 1 2.00 25 25 84 3 4 1 1.00 25 25 70 3 4 1 1.00 45 45 193 3 3/0 1 2.00 45 45 193 3 3/0 1 2.00 25 25 96 3 3 1 1.25 25 25 76 3 4 1 1.00 45 45 204 3 4/0 1 2.00 45 45 204 3 4/0 1 2.00 25 25 101 3 2 1 1.25 25 25 81 3 4 1 1.00 200 225 167 3 2/0 1 2.00 200 225 200 225 167 3 2/0 1 2.00 200 225 100 110 84 3 4 1 1.00 100 110 80 100 70 3 4 1 1.00 80 100 200 225 181 3 3/0 1 2.00 225 250 200 225 181 3 3/0 1 2.00 225 250 100 110 90 3 3 1 1.25 110 125 80 100 76 3 4 1 1.00 90 110 225 250 193 3 3/0 1 2.00 225 250 225 250 193 3 3/0 1 2.00 225 250 110 125 96 3 3 1 1.25 110 125 90 110 76 3 4 1 1.00 90 110 250 250 204 3 4/0 1 2.00 250 250 250 250 204 3 4/0 1 2.00 250 250 125 125 101 3 2 1 1.25 125 125 100 110 81 3 4 1 1.00 100 110 IM 676 23

Table 19, 080E - 135E Electrical Data Multiple Point (continued) Electrical Circuit #1 - Fans and Transformer Electrical Circuit #2 - Compressor Circuit #1 Electrical Circuit #3 - Compressor Circuit #2 ALR Min. Power Supply Field Fusing Min. Power Supply Field Fusing Min. Power Supply Field Fusing Unit Volts HZ. Circuit Field Wire Hub Rec. Max. Circuit Field Wire Hub Rec. Max. Circuit Field Wire Hub Rec. Max. Size Amps Wire Hub Fuse Fuse Amps Wire Hub Fuse Fuse Amps Wire Hub Fuse Fuse (MCA) Qty. Gauge Qty. Size Size Size (MCA) Qty. Gauge Qty. Size Size Size (MCA) Qty. Gauge Qty. Size Size Size 208 60 3 6 1 1.50 230 60 3 6 1 1.50 110E 460 60 29 3 10 1 1.00 575 24 3 10 1 1.00 208 60 3 6 1 1.50 230 60 3 6 1 1.50 120E 460 60 29 3 10 1 1.00 575 24 3 10 1 1.00 208 71 3 4 1 2.00 230 71 3 4 1 2.00 130E 460 60 35 3 8 1 1.25 575 28 3 10 1 1.00 208 71 3 4 1 2.00 230 71 3 4 1 2.00 135E 460 60 35 3 8 1 1.25 575 28 3 10 1 1.00 See page 33 for all Electrical Data notes. 60 60 214 3 4/0 1 2.00 60 60 214 3 4/0 1 2.00 30 30 106 3 2 1 1.25 25 25 81 3 4 1 1.00 60 60 247 3 250 1 2.50 60 60 235 3 250 1 2.50 30 30 122 3 1 1 1.25 25 25 89 3 3 1 1.25 80 80 273 3 300 1 2.50 80 80 252 3 250 1 2.50 35 35 135 3 1/0 1 1.50 30 30 95 3 3 1 1.25 80 80 290 3 350 1 2.50 80 80 271 3 300 1 2.50 35 35 140 3 1/0 1 1.50 30 30 102 3 2 1 1.25 250 300 247 3 250 1 2.50 300 350 250 300 235 3 250 1 2.50 300 300 125 150 122 3 1 1 1.25 150 150 100 110 89 3 3 1 1.25 110 125 300 350 273 3 300 1 2.50 350 350 300 300 252 3 250 1 2.50 300 350 150 150 135 3 1/0 1 1.50 175 175 110 125 95 3 3 1 1.25 110 125 350 350 273 3 300 1 2.50 350 350 300 350 252 3 250 1 2.50 300 350 175 175 135 3 1/0 1 1.50 175 175 110 125 95 3 3 1 1.25 110 125 350 400 290 3 350 1 2.50 350 400 350 350 271 3 300 1 2.50 350 350 175 200 140 3 1/0 1 1.50 175 200 125 150 102 3 2 1 1.25 125 150 Table 20, 140E - 185E Electrical Data Multiple Point Electrical Circuit #1 - Fans and Transformer Electrical Circuit #2 - Compressor Circuit #1 Electrical Circuit #3 - Compressor Circuit #2 ALR Min. Power Supply Field Fusing Min. Power Supply Field Fusing Min. Power Supply Field Fusing Unit Volts HZ Circuit Field Wire Hub Rec. Max. Circuit Field Wire Hub Rec. Max. Circuit Field Wire Hub Rec. Max.. Size Amps Wire Hub Fuse Fuse Amps Wire Hub Fuse Fuse Amps Wire Hub Fuse Fuse (MCA) Qty Gauge Qty Size Size Size (MCA) Qty Gauge Qty Size Size Size (MCA) Qty Gauge Qty Size Size Size 208 71 3 4 1 2.00 230 71 3 4 1 2.00 140E 460 60 35 3 8 1 1.25 575 28 3 10 1 1.00 208 71 3 4 1 2.00 230 71 3 4 1 2.00 145E 460 60 35 3 8 1 1.25 575 28 3 10 1 1.00 See page 33 for all Electrical Data notes. 80 80 304 3 350 1 2.50 80 80 286 3 350 1 2.50 35 35 144 3 1/0 1 1.50 30 30 108 3 2 1 1.25 80 80 304 3 350 1 2.50 80 80 286 3 350 1 2.50 35 35 144 3 1/0 1 1.50 30 30 108 3 2 1 1.25 350 400 304 3 350 1 2.50 350 400 286 3 350 1 2.50 175 200 144 3 1/0 1 1.50 125 150 108 3 2 1 1.25 350 400 304 3 350 1 2.50 350 400 286 3 350 1 2.50 175 200 144 3 1/0 1 1.50 125 150 108 3 2 1 1.25 350 400 350 400 175 200 125 150 350 400 350 400 175 200 125 150 24 IM 676

Table 26, 140E - 185E Electrical Data Multiple Point (continued) Electrical Circuit #1 - Fans and Transformer Electrical Circuit #2 - Compressor Circuit #1 Electrical Circuit #3 - Compressor Circuit #2 ALR Min. Power Supply Field Fusing Min. Power Supply Field Fusing Min. Power Supply Field Fusing Unit Volts HZ Circuit Field Wire Hub Rec. Max. Circuit Field Wire Hub Rec. Max. Circuit Field Wire Hub Rec. Max.. Size Amps Wire Hub Fuse Fuse Amps Wire Hub Fuse Fuse Amps Wire Hub Fuse Fuse (MCA) Qty Gauge Qty Size Size Size (MCA) Qty Gauge Qty Size Size Size (MCA) Qty Gauge Qty Size Size Size 208 71 3 4 1 2.00 230 71 3 4 1 2.00 150E 460 60 35 3 8 1 1.25 575 28 3 10 1 1.00 208 83 3 4 1 2.00 230 83 3 4 1 2.00 160E 460 60 40 3 8 1 1.25 575 33 3 10 1 1.00 208 83 3 4 1 2.00 230 83 3 4 1 2.00 170E 460 60 40 3 8 1 1.25 575 33 3 10 1 1.00 208 83 3 4 1 2.00 230 83 3 4 1 2.00 180E 460 60 40 3 8 1 1.25 575 33 3 10 1 1.00 208 83 3 4 1 2.00 230 83 3 4 1 2.00 185E 460 60 40 3 8 1 1.25 575 33 3 10 1 1.00 See page 33 for all Electrical Data notes. 80 80 304 3 350 1 2.50 80 80 286 3 350 1 2.50 35 35 144 3 1/0 1 1.50 30 30 108 3 2 1 1.25 90 90 338 3 500 1 3.00 (76) 90 90 330 3 400 1 3.00 (76) 40 40 167 3 2/0 1 2.00 35 35 133 3 1/0 1 1.50 90 90 365 3 500 1 3.00 (76) 90 90 365 3 500 1 3.00 (76) 40 40 185 3 3/0 1 2.00 35 35 153 3 2/0 1 2.00 90 90 415 6 300 1 3.00 (76) 90 90 415 6 300 1 3.00 (76) 40 40 199 3 3/0 1 2.00 35 35 162 3 2/0 1 2.00 90 90 455 6 350 1 4.00 (102) 90 90 455 6 350 1 4.00 (102) 40 40 210 3 4/0 1 2.00 35 35 169 3 2/0 1 2.00 350 400 338 3 500 1 3.00 (76) 350 400 330 3 400 1 3.00 (76) 175 200 167 3 2/0 1 2.00 125 150 133 3 1/0 1 1.50 400 400 338 3 500 1 3.00 (76) 400 400 330 3 400 1 3.00 (76) 200 225 167 3 2/0 1 2.00 175 200 133 3 1/0 1 1.50 450 500 365 3 500 1 3.00 (76) 450 500 365 3 500 1 3.00 (76) 225 250 185 3 3/0 1 2.00 175 200 153 3 2/0 1 2.00 500 600 415 6 300 1 3.00 (76) 500 600 415 6 300 1 3.00 (76) 225 250 199 3 3/0 1 2.00 200 225 162 3 2/0 1 2.00 600 600 455 6 350 1 4.00 (102) 600 600 455 6 350 1 4.00 (102) 250 300 210 3 4/0 1 2.00 200 225 169 3 2/0 1 2.00 400 400 400 400 200 225 175 200 400 400 400 400 200 225 175 200 450 500 450 500 225 250 175 200 500 600 500 600 225 250 200 225 600 600 600 600 250 300 200 225 IM 676 25

Table 21, 032E - 075E Compressor And Condenser Fan Motor Amp Draw Rated Load Amps Locked Rotor Amps ALR Compressors Fan No. Of Fan Compressors Unit Volts HZ. No. No. No. No. Motors Fan Motors Across-The-Line Reduced Inrush Size 1 2 3 4 (Each) Motors (Each) No. 1 No. 2 No. 3 No. 4 No. 1 No. 2 No. 3 No. 4 208 60 60 ---- ---- 4.0 4 17.0 308 308 ---- ---- 188 188 ---- ---- 230 60 60 ---- ---- 4.0 4 17.0 308 308 ---- ---- 188 188 ---- ---- 032E 460 60 30 30 ---- ---- 2.0 4 8.5 154 154 ---- ---- 104 104 ---- ---- 575 22 22 ---- ---- 2.2 4 10.3 135 135 ---- ---- 81 81 ---- ---- 208 60 60 ---- ---- 4.0 4 17.0 308 374 ---- ---- 188 222 ---- ---- 230 60 60 ---- ---- 4.0 4 17.0 308 374 ---- ---- 188 222 ---- ---- 035E 460 60 30 30 ---- ---- 2.0 4 8.5 154 187 ---- ---- 104 108 ---- ---- 575 22 24 ---- ---- 2.2 4 10.3 135 135 ---- ---- 81 81 ---- ---- 208 74 74 ---- ---- 4.0 4 17.0 428 428 ---- ---- 250 250 ---- ---- 230 74 74 ---- ---- 4.0 4 17.0 428 428 ---- ---- 250 250 ---- ---- 040E 460 60 37 37 ---- ---- 2.0 4 8.5 214 214 ---- ---- 132 132 ---- ---- 575 31 31 ---- ---- 2.2 4 10.3 172 172 ---- ---- 103 103 ---- ---- 208 74 95 ---- ---- 4.0 6 17.0 428 565 ---- ---- 250 340 ---- ---- 230 74 95 ---- ---- 4.0 6 17.0 428 565 ---- ---- 250 340 ---- ---- 045E 460 60 37 47 ---- ---- 2.0 6 8.5 214 283 ---- ---- 132 156 ---- ---- 575 31 36 ---- ---- 2.2 6 10.3 172 230 ---- ---- 103 138 ---- ---- 208 85 95 ---- ---- 4.0 6 17.0 470 565 ---- ---- 292 340 ---- ---- 230 85 95 ---- ---- 4.0 6 17.0 470 565 ---- ---- 292 340 ---- ---- 050E 460 60 42 47 ---- ---- 2.0 6 8.5 235 283 ---- ---- 141 156 ---- ---- 575 36 36 ---- ---- 2.2 6 10.3 200 230 ---- ---- 130 138 ---- ---- 208 95 95 ---- ---- 4.0 6 17.0 565 565 ---- ---- 340 340 ---- ---- 230 95 95 ---- ---- 4.0 6 17.0 565 565 ---- ---- 340 340 ---- ---- 055E 460 60 47 47 ---- ---- 2.0 6 8.5 283 283 ---- ---- 156 156 ---- ---- 575 36 36 ---- ---- 2.2 6 10.3 230 230 ---- ---- 138 138 ---- ---- 208 95 121 ---- ---- 4.0 6 17.0 565 650 ---- ---- 340 400 ---- ---- 230 95 112 ---- ---- 4.0 6 17.0 565 594 ---- ---- 340 340 ---- ---- 060E 460 60 47 60 ---- ---- 2.0 6 8.5 283 297 ---- ---- 156 195 ---- ---- 575 36 42 ---- ---- 2.2 6 10.3 230 245 ---- ---- 138 152 ---- ---- 208 121 121 ---- ---- 4.0 6 17.0 650 650 ---- ---- 400 400 ---- ---- 230 112 112 ---- ---- 4.0 6 17.0 594 594 ---- ---- 340 340 ---- ---- 065E 460 60 60 60 ---- ---- 2.0 6 8.5 297 297 ---- ---- 195 195 ---- ---- 575 42 42 ---- ---- 2.2 6 10.3 245 245 ---- ---- 152 152 ---- ---- 208 121 135 ---- ---- 4.0 8 17.0 650 754 ---- ---- 400 463 ---- ---- 230 112 127 ---- ---- 4.0 8 17.0 594 594 ---- ---- 340 340 ---- ---- 070E 460 60 60 64 ---- ---- 2.0 8 8.5 297 297 ---- ---- 195 195 ---- ---- 575 42 48 ---- ---- 2.2 8 10.3 245 245 ---- ---- 152 152 ---- ---- 208 135 135 ---- ---- 4.0 10 17.0 754 754 ---- ---- 463 463 ---- ---- 230 127 127 ---- ---- 4.0 10 17.0 594 594 ---- ---- 340 340 ---- ---- 075E 460 60 64 64 ---- ---- 2.0 10 8.5 297 297 ---- ---- 195 195 ---- ---- 575 48 48 ---- ---- 2.2 10 10.3 245 245 ---- ---- 152 152 ---- ---- See page 33 for all Electrical Data notes. 26 IM 676

Table 22, 080E -135E Compressor And Condenser Fan Motor Amp Draw Rated Load Amps Locked Rotor Amps ALR Compressors Fan No. Of Fan Compressors Unit Volts HZ. No. No. No. No. Motors Fan Motors Across-The-Line Reduced Inrush Size 1 2 3 4 (Each) Motors (Each) No. 1 No. 2 No. 3 No. 4 No. 1 No. 2 No. 3 No. 4 208 74 74 74 74 4.0 10 17.0 428 428 428 428 250 250 250 250 230 74 74 74 74 4.0 10 17.0 428 428 428 428 250 250 250 250 080E 460 60 37 37 37 37 2.0 10 8.5 214 214 214 214 132 132 132 132 575 31 31 31 31 2.2 10 10.3 172 172 172 172 103 103 103 103 208 74 74 74 85 4.0 10 17.0 428 428 428 470 250 250 250 292 230 74 74 74 85 4.0 10 17.0 428 428 428 470 250 250 250 292 085E 460 60 37 37 37 42 2.0 10 8.5 214 214 214 235 132 132 132 141 575 31 31 31 36 2.2 10 10.3 172 172 172 200 103 103 103 130 208 95 95 74 74 4.0 10 17.0 565 565 428 428 340 340 250 250 230 95 95 74 74 4.0 10 17.0 565 565 428 428 340 340 250 250 090E 460 60 47 47 37 37 2.0 10 8.5 283 283 214 214 156 156 132 132 575 36 36 31 31 2.2 10 10.3 230 230 172 172 138 138 103 103 208 95 95 85 85 4.0 10 17.0 565 565 470 470 340 340 292 292 230 95 95 85 85 4.0 10 17.0 565 565 470 470 340 340 292 292 100E 460 60 47 47 42 42 2.0 10 8.5 283 283 235 235 156 156 141 141 575 36 36 36 36 2.2 10 10.3 230 230 200 200 138 138 130 130 208 95 95 95 121 5.8 10 23.7 565 565 565 650 340 340 340 400 230 95 95 95 112 5.8 10 21.4 565 565 565 594 340 340 340 340 110E 460 60 47 47 47 60 2.8 10 10.7 283 283 283 297 156 156 156 195 575 36 36 36 42 2.3 10 11.5 230 230 230 245 138 138 138 152 208 95 121 121 121 5.8 10 23.7 565 650 650 650 340 400 400 400 230 95 112 112 112 5.8 10 21.4 565 594 594 594 340 340 340 340 120E 460 60 47 60 60 60 2.8 10 10.7 283 297 297 297 156 195 195 195 575 36 42 42 42 2.3 10 11.5 230 245 245 245 138 152 152 152 208 121 121 121 121 5.8 12 23.7 650 650 650 650 400 400 400 400 230 112 112 112 112 5.8 12 21.4 594 594 594 594 340 340 340 340 130E 460 60 60 60 60 60 2.8 12 10.7 297 297 297 297 195 195 195 195 575 42 42 42 42 2.3 12 11.5 245 245 245 245 152 152 152 152 208 121 121 135 135 5.8 12 23.7 650 650 754 754 400 400 463 463 230 112 112 127 127 5.8 12 21.4 594 594 594 594 340 340 340 340 135E 460 60 60 60 64 64 2.8 12 10.7 297 297 297 297 195 195 195 195 575 42 42 48 48 2.3 12 11.5 245 245 245 245 152 152 152 152 See page 33 for all Electrical Data notes. IM 676 27

Table 23, 140E - 185E Compressor And Condenser Fan Motor Amp Draw Rated Load Amps Locked Rotor Amps ALR Compressors Fan No. Of Fan Compressors Unit Volts HZ. No. No. No. No. Motors Fan Motors Across-The-Line Reduced Inrush Size 1 2 3 4 (Each) Motors (Each) No. 1 No. 2 No. 3 No. 4 No. 1 No. 2 No. 3 No. 4 208 135 135 135 135 5.8 12 23.7 754 754 754 754 463 463 463 463 230 127 127 127 127 5.8 12 21.4 594 594 594 594 340 340 340 340 140E 460 60 64 64 64 64 2.8 12 10.7 297 297 297 297 195 195 195 195 575 48 48 48 48 2.3 12 11.5 245 245 245 245 152 152 152 152 208 135 135 135 135 5.8 12 23.7 754 754 754 754 463 463 463 463 230 127 127 127 127 5.8 12 21.4 594 594 594 594 340 340 340 340 145E 460 60 64 64 64 64 2.8 12 10.7 297 297 297 297 195 195 195 195 575 48 48 48 48 2.3 12 11.5 245 245 245 245 152 152 152 152 208 135 135 135 162 5.8 12 23.7 754 754 754 1070 463 463 463 654 230 127 127 127 162 5.8 12 21.4 594 594 594 1070 340 340 340 654 150E 460 60 64 64 64 82 2.8 12 10.7 297 297 297 510 195 195 195 330 575 48 48 48 68 2.3 12 11.5 245 245 245 405 152 152 152 262 208 135 135 162 162 5.8 14 23.7 754 754 1070 1070 463 463 654 654 230 127 127 162 162 5.8 14 21.4 594 594 1070 1070 340 340 654 654 160E 460 60 64 64 82 82 2.8 14 10.7 297 297 510 510 195 195 330 330 575 48 48 68 68 2.3 14 11.5 245 245 405 405 152 152 262 262 208 162 162 162 162 5.8 14 23.7 1070 1070 1070 1070 654 654 654 654 230 162 162 162 162 5.8 14 21.4 1070 1070 1070 1070 654 654 654 654 170E 460 60 82 82 82 82 2.8 14 10.7 510 510 510 510 330 330 330 330 575 68 68 68 68 2.3 14 11.5 405 405 405 405 262 262 262 262 208 162 162 202 202 5.8 14 23.7 1070 1070 1070 1070 654 654 654 654 230 162 162 202 202 5.8 14 21.4 1070 1070 1070 1070 654 654 654 654 180E 460 60 82 82 93 93 2.8 14 10.7 510 510 510 510 330 330 330 330 575 68 68 75 75 2.3 14 11.5 405 405 405 405 262 262 262 262 208 202 202 202 202 5.8 14 23.7 1070 1070 1070 1070 654 654 654 654 230 202 202 202 202 5.8 14 21.4 1070 1070 1070 1070 654 654 654 654 185E 460 60 93 93 93 93 2.8 14 10.7 510 510 510 510 330 330 330 330 575 75 75 75 75 2.3 14 11.5 405 405 405 405 262 262 262 262 See page 33 for all Electrical Data notes. 28 IM 676

Table 24, 032E -075E Field Wiring Data, Single Point Power Wiring to Wiring to ALR Standard Power Block Optional Disconnect Switch Unit Volts HZ. Terminal Connector Wire Range Terminal Connector Wire Range Size Amps (Copper Wire Only) Amps (Copper Wire Only) 208 335 (1 qty.) #4-400 MCM 225 (1 qty.) #3-300 MCM 230 335 (1 qty.) #4-400 MCM 225 (1 qty.) #3-300 MCM 032E 460 60 335 (1 qty.) #4-400 MCM 100 (1 qty.) #14-1/0 575 335 (1 qty.) #4-400 MCM 100 (1 qty.) #14-1/0 208 335 (1 qty.) #4-400 MCM 225 (1 qty.) #3-300 MCM 230 335 (1 qty.) #4-400 MCM 225 (1 qty.) #3-300 MCM 035E 460 60 335 (1 qty.) #4-400 MCM 100 (1 qty.) #14-1/0 575 335 (1 qty.) #4-400 MCM 100 (1 qty.) #14-1/0 208 335 (1 qty.) #4-400 MCM 225 (1 qty.) #3-300 MCM 230 335 (1 qty.) #4-400 MCM 225 (1 qty.) #3-300 MCM 040E 460 60 335 (1 qty.) #4-400 MCM 100 (1 qty.) #14-1/0 575 335 (1 qty.) #4-400 MCM 100 (1 qty.) #14-1/0 208 335 (1 qty.) #4-400 MCM 225 (1 qty.) #3-300 MCM 230 335 (1 qty.) #4-400 MCM 225 (1 qty.) #3-300 MCM 045E 460 60 335 (1 qty.) #4-400 MCM 150 (1 qty.) #4-4/0 575 335 (1 qty.) #4-400 MCM 100 (1 qty.) #14-1/0 208 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 230 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 050E 460 60 335 (1 qty.) #4-400 MCM 150 (1 qty.) #4-4/0 575 335 (1 qty.) #4-400 MCM 100 (1 qty.) #14-1/0 208 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 230 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 055E 460 60 335 (1 qty.) #4-400 MCM 150 (1 qty.) #4-4/0 575 335 (1 qty.) #4-400 MCM 100 (1 qty.) #14-1/0 208 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 230 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 060E 460 60 335 (1 qty.) #4-400 MCM 150 (1 qty.) #4-4/0 575 335 (1 qty.) #4-400 MCM 150 (1 qty.) #4-4/0 208 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 230 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 065E 460 60 335 (1 qty.) #4-400 MCM 250 (1 qty.) #4-350 MCM 575 335 (1 qty.) #4-400 MCM 150 (1 qty.) #4-4/0 208 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 230 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 070E 460 60 335 (1 qty.) #4-400 MCM 250 (1 qty.) #4-350 MCM 575 335 (1 qty.) #4-400 MCM 150 (1 qty.) #4-4/0 208 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 230 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 075E 460 60 335 (1 qty.) #4-400 MCM 250 (1 qty.) #4-350 MCM 575 335 (1 qty.) #4-400 MCM 150 (1 qty.) #4-4/0 See page 33 for all Electrical Data notes. IM 676 29

Table 25, 080E - 135E Field Wiring Data,Single Point Power Wiring to Wiring to ALR Standard Power Block Optional Disconnect Switch Unit Volts HZ. Terminal Connector Wire Range Terminal Connector Wire Range Size Amps (Copper Wire Only) Amps (Copper Wire Only) 208 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 230 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 080E 460 60 335 (1 qty.) #4-400 MCM 250 (1qty.) #4-350 MCM 575 335 (1 qty.) #4-400 MCM 250 (1qty.) #4-350 MCM 208 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 230 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 085E 460 60 335 (1 qty.) #4-400 MCM 250 (1qty.) #4-350 MCM 575 335 (1 qty.) #4-400 MCM 250 (1qty.) #4-350 MCM 208 840 (2 qty.) 1/0-600 MCM 600 (2 qty.) 250-500 MCM 230 840 (2 qty.) 1/0-600 MCM 600 (2 qty.) 250-500 MCM 090E 460 60 335 (1 qty.) #4-400 MCM 250 (1qty.) #4-350 MCM 575 335 (1 qty.) #4-400 MCM 250 (1qty.) #4-350 MCM 208 840 (2 qty.) 1/0-600 MCM 600 (2 qty.) 250-500 MCM 230 840 (2 qty.) 1/0-600 MCM 600 (2 qty.) 250-500 MCM 100E 460 60 335 (1 qty.) #4-400 MCM 250 (1qty.) #4-350 MCM 575 335 (1 qty.) #4-400 MCM 250 (1qty.) #4-350 MCM 208 840 (2 qty.) 1/0-600 MCM 600 (2 qty.) 250-500 MCM 230 840 (2 qty.) 1/0-600 MCM 600 (2 qty.) 250-500 MCM 110E 460 60 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 575 335 (1 qty.) #4-400 MCM 250 (1qty.) #4-350 MCM 208 840 (2 qty.) 1/0-600 MCM 600 (2 qty.) 250-500 MCM 230 840 (2 qty.) 1/0-600 MCM 600 (2 qty.) 250-500 MCM 120E 460 60 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 575 335 (1 qty.) #4-400 MCM 250 (1qty.) #4-350 MCM 208 840 (2 qty.) 1/0-600 MCM N/A 230 840 (2 qty.) 1/0-600 MCM N/A 130E 460 60 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 575 335 (1 qty.) #4-400 MCM 250 (1qty.) #4-350 MCM 208 840 (2 qty.) 1/0-600 MCM N/A 230 840 (2 qty.) 1/0-600 MCM N/A 135E 460 60 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 575 335 (1 qty.) #4-400 MCM 250 (1qty.) #4-350 MCM See page 33 for all Electrical Data notes. 30 IM 676

Table 26, 140E - 185E Field Wiring Data, Single Point Power Wiring to Wiring to ALR Standard Power Block Optional Disconnect Switch Unit Volts HZ. Terminal Connector Wire Range Terminal Connector Wire Range Size Amps (Copper Wire Only) Amps (Copper Wire Only) 208 840 (2 qty.) 1/0-600 MCM N/A 230 840 (2 qty.) 1/0-600 MCM N/A 140E 460 60 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 575 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 208 840 (2 qty.) 1/0-600 MCM N/A 230 840 (2 qty.) 1/0-600 MCM N/A 145E 460 60 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 575 335 (1 qty.) #4-400 MCM 400 (1 qty.) 250-500 MCM 208 840 (4 qty.) 1/0-600 MCM N/A 230 840 (4 qty.) 1/0-600 MCM N/A 150E 460 60 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 575 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 208 840 (*) (4 qty.) 1/0-600 MCM N/A 230 840 (*) (4 qty.) 1/0-600 MCM N/A 160E 460 60 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 575 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 208 840 (*) (4 qty.) 1/0-600 MCM N/A 230 840 (*) (4 qty.) 1/0-600 MCM N/A 170E 460 60 840 (2 qty.) 1/0-600 MCM 600 (1 qty.) 250-500 MCM 575 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 208 840 (*) (4 qty.) 1/0-600 MCM N/A 230 840 (*) (4 qty.) 1/0-600 MCM N/A 180E 460 60 840 (2 qty.) 1/0-600 MCM 600 (1 qty.) 250-500 MCM 575 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM 208 840 (*) (4 qty.) 1/0-600 MCM N/A 230 840 (*) (4 qty.) 1/0-600 MCM N/A 185E 460 60 840 (2 qty.) 1/0-600 MCM 600 (1 qty.) 250-500 MCM 575 840 (2 qty.) 1/0-600 MCM 400 (1 qty.) 250-500 MCM * There are 2 power blocks, each having 840 terminal amps. (1680 total terminal amps) See page 33 for all other Electrical Data notes. IM 676 31

Table 27, 032E - 075E Field Wiring Data, Multiple Point Power ALR Wiring to Standard Power Block Unit Volts HZ. Terminal Amps Connector Wire Range (Copper Wire Only) Size Circuit 1 Circuit 2 Circuit 3 Circuit 1 Circuit 2 Circuit 3 208 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 230 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 032E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 230 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 035E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 040E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 045E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 050E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 055E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 060E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 065E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 230 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 070E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 230 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 075E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 See page 33 for all Electrical Data notes. 32 IM 676

Table 28, 080E - 185E Field Wiring Data, Multiple Point Power ALR Wiring to Standard Power Block Unit Volts HZ. Terminal Amps Connector Wire Range (Copper Wire Only) Size Circuit 1 Circuit 2 Circuit 3 Circuit 1 Circuit 2 Circuit 3 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 080E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 085E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 090E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 100E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 110E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 120E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 130E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 230 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 135E 460 60 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 575 175 175 175 (1 qty.) #12-2/0 (1 qty.) #12-2/0 (1 qty.) #12-2/0 208 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 230 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 140E 460 60 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 575 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 208 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 230 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 145E 460 60 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 575 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 208 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 230 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 150E 460 60 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 575 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 208 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 230 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 160E 460 60 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 575 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 208 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 230 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 170E 460 60 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 575 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 208 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 230 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 180E 460 60 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 575 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 208 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 230 175 840 840 (1 qty.) #12-2/0 (2 qty.) 1/0-600 MCM (2 qty.) 1/0-600 MCM 185E 460 60 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM 575 175 335 335 (1 qty.) #12-2/0 (1 qty.) #4-400 MCM (1 qty.) #4-400 MCM See page 33 for all Electrical Data notes. IM 676 33

Notes for Electrical Data Single Point and Electrical Data Multiple Point Power: 1. Unit wire size ampacity (MCA) is equal to 125% of the largest compressor-motor RLA plus 100% of RLA of all other loads in the circuit including the control transformer. 2. If the control transformer option is furnished, no separate 115v power is required. 3. If a separate 115V power supply is used for the control circuit, then the wire sizing amps is: 10 amps for unit sizes ALR032E through ALR075E 12 amps for unit sizes ALR080E through ALR185E 4. Recommended power lead wire sizes for 3 conductors per conduit are based on 100% conductor ampacity in accordance with NEC. Wire sizes for 6 conductors per conduit are based on 80% conductor ampacity in accordance with NEC. Voltage drop has not been included. Therefore, it is recommended that power leads be kept short. All terminal block connections must be made with copper (type THW) wire. 5. The unit power terminal block may have 2 lugs per phase. Single or parallel conductors should be used for power connections as listed under Recommended Power Lead Wire Size. 6. Recommended Fuse Sizes are selected at approximately 150% of the largest compressor RLA, plus 100% of all other loads in the circuit. 7. Maximum Fuse Sizes are selected at approximately 225% of the largest compressor RLA, plus 100% of all other loads in the circuit. 8. The recommended power lead wire sizes are based on an ambient temperature of 86 F. Ampacity correction factors must be applied for other ambient temperatures. Refer to the National Electrical Code Handbook. Voltage Limitations: Unit Nameplate - 208V/60Hz/3Ph: 187V to 253V (except ALR060E through ALR155E: 187V to 220V) Unit Nameplate - 230V/60Hz/3Ph: 187V to 253V (except ALR060E through ALR155E: 207V to 253V) Unit Nameplate - 460V/60Hz/3Ph: 414V to 506V Unit Nameplate - 575V/60Hz/3Ph: 517V to 633V Notes for Compressor and Condenser Fan Amp Draw : 1. Compressor RLA values are for wiring sizing purposes only but do not reflect normal operating current draw at rated capacity. If unit is equipped with SpeedTrol condenser fan motors, the first motor on each refrigerant circuit is a single phase, 1hp motor, with a FLA of 2.8 amps at 460 volts, 5.6 amps at 208, 230, and 575 volts. 2. Compressor LRA for reduced inrush start are for the first winding only. If the unit is equipped with SpeedTrol motors, the first motor is a single phase, 1 hp motor, with a LRA of 7.3 amps at 460 volts, 14.5 amps at 208, 230 and 575 volts. Notes for Field Wiring Data - Both Single and Multiple Point Power: 1. Single point power supply requires a single disconnect to supply electrical power to the unit. This power must be fused. 2. Multiple point power supply requires two independent power circuits each with separate disconnects and a separate control circuit. 3. All field wiring to unit power block or optional non-fused disconnect switch must be copper. 4. All field wire size values given in table apply to 75 C rated wire per NEC. 34 IM 676

Figure 7,ALR 032E through 185E, typical field wiring diagram IM 676 35

Dimensional Data Figure 8, 032E through 100E Dimensions ALR EVAPORATOR WATER CONNECTIONS CENTER OF GRAVITY ISOLATOR LOCATION NUMBER UNIT "A" CONN. B C D E X Y R S T OF SIZE LENGTH SIZE (1) FANS 032E 123 (3124) 4 (102) 96.3 (2446) 11.0 (279) 22.7 (477) 14.9 (378) 55.0 (1397) 41.7 (1059) 13 (330) 43 (1092) 109 (2769) 4 035E 123 (3124) 4 (102) 96.3 (2446) 11.0 (279) 22.7 (477) 14.9 (378) 55.0 (1397) 41.7 (1059) 13 (330) 43 (1092) 109 (2769) 4 040E 123 (3124) 4 (102) 96.3 (2446) 11.0 (279) 22.7 (477) 14.9 (378) 55.0 (1397) 41.7 (1059) 13 (330) 43 (1092) 109 (2769) 4 045E 176 (4470) 4 (102) 98.4 (2499) 13.0 (330) 29.7 (754) 14.9 (378) 77.0 (1956) 41.7 (1059) 13 (330) 58 (1473) 162 (4115) 6 050E 176 (4470) 5 (127) 98.4 (2499) 13.0 (330) 28.6 (726) 15.9 (404) 77.0 (1956) 41.7 (1059) 13 (330) 58 (1473) 162 (4115) 6 055E 176 (4470) 5 (127) 98.4 (2499) 13.0 (330) 28.6 (726) 15.9 (404) 77.0 (1956) 41.7 (1059) 13 (330) 58 (1473) 162 (4115) 6 060E 176 (4470) 5 (127) 98.4 (2499) 13.0 (330) 28.6 (726) 15.9 (404) 77.0 (1956) 41.7 (1059) 13 (330) 58 (1473) 162 (4115) 6 065E 176 (4470) 5 (127) 98.4 (2499) 13.0 (330) 28.6 (726) 15.9 (404) 77.0 (1956) 41.7 (1059) 13 (330) 58 (1473) 162 (4115) 6 070E 229 (5817) 5 (127) 150.6 (3825) 66.8 (1697) 28.6 (726) 15.9 (404) 90.0 (2286) 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 8 075E 229 (5817) 5 (127) 150.6 (3825) 66.8 (1697) 28.6 (726) 15.9 (404) 90.0 (2286) 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 10 080E 229 (5817) 5 (127) 150.6 (3825) 66.8 (1697) 28.6 (726) 15.9 (404) 90.0 (2286) 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 10 085E 229 (5817) 6 (152.4) 117.6 (2987) 13.8 (351) 28.6 (726) 19.5 (495) 88.0 (1059) 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 10 090E 229 (5817) 6 (152.4) 117.6 (2987) 13.8 (351) 28.6 (726) 19.5 (495) 88.0 (1059) 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 10 100E 229 (5817) 6 (152.4) 117.6 (2987) 13.8 (351) 28.6 (726) 19.5 (495) 104.7 (2659) 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 10 36 IM 676

Figure 9, 110E through 185E Dimensions ALR EVAPORATOR CENTER OF GRAVITY ISOLATOR LOCATION NUMBER UNIT "A" CONN. WATER CONNECTIONS X Y R S T OF SIZE LENGTH SIZE (1) B C E FANS 110E 229 (5817) 6 (152.4) 117.6 (2987) 120E 229 (5817) 6 (152.4) 118.5 (3010) 130E 229 (5817) 6 (152.4) 118.5 (3010) 135E 229 (5817) 6 (152.4) 118.5 (3010) 140E 229 (5817) 6 (152.4) 118.5 (3010) 145E 229 (5817) 6 (152.4) 118.5 (3010) 150E 229 (5817) 6 (152.4) 118.5 (3010) 160E 263 (6680) 6 (152.4) 153.2 (3891) 170E 263 (6680) 6 (152.4) 153.2 (3891) 180E 263 (6680) 6 (152.4) 153.2 (3891) 185E 263 (6680) 6 (152.4) 153.2 (3891) 13.8 (351) 19.5 (495) 106.5 (2705) 12.9 (328) 19.5 (495) 106.5 (2705) 12.9 (328) 19.5 (495) 107.0 (2718) 12.9 (328) 19.5 (495) 105.0 (2667) 12.9 (328) 19.5 (495) 108.0 (2743) 12.9 (328) 20.5 (521) 103.0 (2616) 12.9 (328) 20.5 (521) 105.0 (2667) 47.6 (1209) 20.5 (521) 121.0 (3074) 47.6 (1209) 20.5 (521) 119.0 (3023) 47.6 (1209) 20.5 (521) 118.0 (2997) 47.6 (1209) 20.5 (521) 118.0 (2997) 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 10 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 10 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 12 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 12 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 12 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 12 41.7 (1059) 13 (330) 58 (1473) 215 (5461) 12 41.7 (1059) 13 (330) 95 (2413) 250 (6350) 14 41.7 (1059) 13 (330) 95 (2413) 250 (6350) 14 41.7 (1059) 13 (330) 95 (2413) 250 (6350) 14 41.7 (1059) 13 (330) 95 (2413) 250 (6350) 14 IM 676 37

Unit Layout and Principles of Operation Figure 10, Major component locations The figure below illustrates component locations for each unit size. Control Center All electrical controls are enclosed in a weatherproof control center with keylocked, hinged access doors. The control center has two separate compartments, high voltage and low voltage. All high voltage components are located in the compartment on the right side of the unit. The low voltage components are located on the left side with the live terminals behind the deadfront panel. This protects service personnel from live terminals when accessing the adjustable and resettable controls. Control center layouts ALR 032E through 75E Figure 11, Left side, 115V control section Figure 12, Right side, high voltage power section Note: PB1, PB2, PB3 are used with multiple point power wiring 38 IM 676

Control center layouts ALR 080E through 185E Figure 13, Left side, 115V control section Figure 14, Right side, high voltage power section Note: PB1, PB2, PB3 are used with multiple point power wiring Figure 15,Recommended field installed unit disconnect location Hinged Doors on Control Center Stationary Panel 9.5" (241mm) Min. Disconnect Switch 6" (152mm) Min. Power Into Unit Note: Mount disconnect on stationary panel so it does not interfere with hinged doors or with air intake into coil. IM 676 39

Start-up and Shutdown Pre Start-up 1. Open all electric disconnects and check all electric connections for tightness. Check all compressor valve connections for tightness. 2. Inspect all water piping for flow direction and correct connections at the evaporator. 3. Verify thermostat water temperature sensor is installed in the leaving water line (supply to building). On all ALR units the sensor well and sensor are factory mounted. 4. Check compressor oil level. The oil level should be visible in the oil sightglass. 5. Check voltage of the unit power supply and make certain voltage is within ±10% of nameplate rating. 6. Check unit power supply wiring for proper ampacity and a minimum insulation temperature of 75 C. 7. Verify all mechanical and electrical inspections have been completed according to local codes. 8. Verify all auxiliary control equipment is operative and an adequate cooling load is available. 9. Open compressor suction and discharge shutoff valves until backseated. Always replace valve seal caps. 10. Open control stop switch S1(off) and place pumpdown switches PS1 and PS2 on manual pumpdown,. Turn on the main power and control disconnect switches. This will energize crankcase heaters. Wait at least 12 hours before starting up unit. 11. Open all water flow valves and start the chilled water pump. Check all piping for leaks and vent the air from the evaporator as well as from the system piping. Flush the evaporator and system piping to obtain clean, noncorrosive water in the evaporator. NOTE: If LWC1 is a Unit 33 Metasys control, the control must be energized before the chilled water flow switch is closed. CAUTION Most relays and terminals in the unit control center are energized with S1 and the control circuit disconnect on. Do not close S1 until start-up. Start-up 1. Verify compressor suction and discharge shutoff valves are backseated. Always replace valve seal caps. 2. Open oil equalization line valve (ALR 080E through 185E only). 3. Open manual liquid line shutoff valve at the outlet of the condenser subcooler. 4. Set temperature controller LWC1 to the desired chilled water temperature. Set the control band. 5. Start auxillary equipment by turning on the following: Time clock Ambient thermostat and/or remote on/off switch Chilled water pump. 6. Verify pumpdown switches PS1 and PS2 are in manual pumpdown (open) position. If pressures on the low side of the system are above 60 psig (414 kpa), the unit will start and pump down. 40 IM 676

7. After compressor lockout timer TD1 has timed out, start the system by moving pumpdown switches PS1 and PS2 to auto pumpdown position. 8. After running the unit for a short time, check the following: Oil level in each compressor crankcase Rotation of fans Flashing in refrigerant sightglass. 9. Verify superheat temperature is at the factory setting of 8 to 12 degrees F (4.4 to 6.7 degrees C). 10. After system performance has stabilized, complete the Compressorized Equipment Warranty Form (Form No. 415415Y) to obtain full warranty benefits. Return the form to McQuay International through your sales representative. Sequence of Operation The following sequence of operation is typical for ALR SeasonPak air-cooled water chiller, Models ALR 032E through ALR 185E (items in italics apply only to Models ALR 080E through 185E). The sequence varies depending upon options. Start - up With the control circuit power on and the control stop switch S1 closed, 115V power is applied through the control circuit fuse F1 to the compressor crankcase heaters HTR1 and HTR2 (HTR3 and HTR4), the compressor motor protections MP1 and MP2 (MP3 and MP4), and the primary of the 24V control circuit transformer. The 24V transformer provides power to the contacts of the low pressure controls LP1 and LP2 and the compressor lockout timer TD1 and TD2. When the remote time clock or manual shutdown switch turns on the chilled water pump, the flow switch closes and 115V power is applied to the relay contacts on the leaving water control LWC1. The unit will automatically operate in response to the LWC1 if the manual pumpdown switches PS1 and PS2 are closed ( in the auto position); the compressor lockout time relays R5 and R6 (R7 and R8); and the freezestats FS1 and FS2, high pressure controls HP1 and HP2, and the compressor motor protectors MP1 and MP2 (MP3 and MP4) do not sense failure conditions. On a call for cooling, the leaving water control LWC1 completes the circuit to the liquid line solenoid valve SV1 for refrigerant circuit #1, opening the valve and allowing refrigerant to flow through the expansion valve and into the evaporator. As the evaporator refrigerant pressure increases, the low pressure control LP1 closes. This energizes the compressor starting relay R9, starting the compressor via the compressor contactors M1 and M5. Closing the R9 contacts also energizes the condenser fan motor contacts M11 and M12 starting the fan motors. As additional stages of cooling capacity are required, the leaving water control LWC1 energizes the liquid line solenoid valve SV2 of the refrigerant circuit #2. After the compressor sequencing time delay TD11 has closed, the same starting sequence is initiated in refrigerant circuit #2. If still more cooling is required, the leaving water control will start the remaining compressors and then de-energize unloader solenoids until the capacity requirement is met. IM 676 41

Pumpdown As the leaving water control is satisfied, it will unload the compressor(s) and then de-energize the liquid line solenoid valve(s) SV1 and SV2, causing the valve(s) to close. When the compressor has pumped most of the refrigerant out of the evaporator and into the condenser, the low pressure control(s) LP1 and LP2 will open. If the refrigerant leaks into the low side causing the pressure to close the low pressure controls LP1 and LP2, the compressor will start after a two-hour time delay. For normal temperature controlled operation, the timer is bypassed and the compressor will start on a refrigerant pressure rise. Note: Do not shut the unit down without going through the pumpdown cycle. Flow switch, time clock, and ambient lockout thermostat must be wired to allow pumpdown when unit is turned off.. 42 IM 676

13600 Industrial Park Boulevard, P.O. Box 1551, Minneapolis, MN 55440 USA (612) 553-5330