SMX Lumi-Hub Installation Guide

Similar documents
THX & TIX Lumi-Hub Installation Guide

SMX 22, SMX52 & SMX 102 Installation and Operating Guide

SMX 92 & SMX 152 Installation and Operating Guide

TIX 402, TIX 802 & TIX 1602 Thru-Hull Light Lumishore SUPRA (dual colour) light Installation and Operating Guide

THX 402, THX 802 & THX 1602 Thru-Hull Light Lumishore SUPRA (dual colour) light Installation and Operating Guide

TIX402 EOS Installation and Operating Guide

SCM-Power Distribution PLUS system Installation and User Instructions:

Single Colour Light. TIX202 Interchangeable Flush Fit Thru-Hull Light. Installation and Operation Guide. Rev

Surface Mount e-lites

User Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring

CO₂ Sensor Replacement (RF598 and RF602) Installation Instructions

ARDUINO 2WD SMART ROBOT CAR KIT

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

TCM D Single Zone, 24 Volt DC Timer Control Module User s Manual D-M-E Company

Single Colour Light. TIX301 Interchangeable Flush Fit Thru-Hull Light. Installation and Operation Guide

3 Year Warranty. heavy duty Wiper systems. Heavy Duty Motor NEW!!! AFI 2.5 Wiper Motor Waterproof Wiper Motor. AFI Ph:

Installation Instructions

Fuse / Circuit Breaker Panels

AquiTron. AT-PIR-SOV Water Shut-Off System INSTALLATION INSTRUCTIONS

Installation Instruction

USER MANUAL QUICK INSTALLATION GUIDE MRGB65B

AUTO ISOLATOR I AN AUTOMATIC LOSSLESS BATTERY ISOLATOR FOR DUAL BATTERY SYSTEMS

Troubleshooting Guide for Stamford Generators

SERVICE MANUAL. Koala

Power Distribution System User s Manual. Model: PDS-100

Table of Contents. Parts Overview 1-3. Tools Needed 4. Recommended Service Parts 4. Gas Fire-Up Check List 5. Troubleshooting Flow Chart 6-9

PIL0478 ISSUE 01/ 07/16

IHS series Hall effect pushbutton switches - bushing Ø 12 mm - momentary Overview IHS SERIES Actuator shapes Electrical function Operating force Termi

Detroit Speed, Inc. RS Electric Headlight Door Kit 1969 Camaro P/N: (3)

POWER WINDOWS Toyota 4Runner DESCRIPTION & OPERATION TROUBLE SHOOTING COMPONENT TESTS POWER WINDOW SWITCH CONTINUITY TEST (DRIVER S SIDE SWITCH)

Instruction & Owner s Manual

poollux Power plx-pw60 & plx-pw100

Pantera Electronics Rocker Switch Installation Manual

Solstice Electric Fryers SE Series Service Manual

PS24/AC Volt AC 16 Amp

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

ARCHITECTURAL CONTROL SYSTEMS, INCORPORATED ST. LOUIS, MISSOURI

Detroit Speed, Inc. RS Electric Headlight Door Kit 1968 Camaro P/N: (3)

Operation and Installation Manual

Installation & Operation Manual

Wiper Motor Windshield Frame Mount Marinco-500. Installation Instructions

PARTS AND CUSTOMER SERVICE BULLETIN

Detroit Speed, Inc. Electric Headlight Door Kit Corvette P/N: &

AUTO PUMP STATUS CENTER

Custom Dynamics Spyder Stingerz Installation Instructions

Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

BlackAir V12 Active Bass Enclosure Model: BLACKAIRV12-V2

MT350 ACCESSORY WIRING

AUXILIARY LIGHTING SPARES // 87-92

SCCP PWM Charge Controller/Load Manager Owner s Manual

Bluefin Led Underwater lights.

White Light CLASSIC PEDAL KIT. Assembly Instructions WHEN YOU CAN T BUY IT BUILD IT. StewMac RARE / VINTAGE / HARD TO GET

PACIFIC Recumbent Height-Adjustable Bath System Parts Breakdown and Assembly Manual

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Tecomotive - tinycwa User Manual

QUICKSTART. Quickstart. A higher level of performance

Vehicle Service Parts (may be required for reassembly) Legend

3 in 1 TRAIL CHARGER with LOCKOUT

Wiring Harness Replacement Instructions - 3 Phase 2561

Navigator 550 Sodium wet-section

Temperature Control Panel Wiring Diagram Model: ISPA-120-1P-15A

CENTRAL BATTERY UNIT. Installation and maintenance instructions TKT3122

Your Global Flow Control Partner. Series 70 24V On/Off Electric Actuator Operation and Maintenance Manual

Wireless Remote System RC-12v & 24v Standard RF Remote Control System INSTALLATION MANUAL AND OWNERS GUIDE Table of Contents:

STR3. Step Motor Drive. User Manual

- 4 amp (100VA). - 4 amp (100VA). - Eight (8) Fuse Protected Outputs. - Eight (8) PTC Protected Outputs.

FUSE PANEL. Technical Practice N N-L33 10/10 GMT Front Access NEBS Level 3 Certified

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

FUSE PANEL Technical Practice N N-L34 20/20 GMT (23 panel) NEBS Level 3 Certified

Table 3. Pumping Range. 6 in cm. 8 in cm. 16 in cm. 6 in cm. 14 in cm. 18 in cm.

TRAC-Station BT Installation Instructions

SERVICE MANUAL. Chairman. Playman/Robo

Westell FUSE PANEL. Technical Practice N Position Type VDC Floating

ELECTRICAL. Contents - Wiring Diagrams

TIX 802 & TIX 1602 Thru-Hull Light Lumishore EOS Full Colour Change light Installation and Operating Guide

CLASSIC PEDAL KIT. Assembly Instructions WHEN YOU CAN T BUY IT BUILD IT. StewMac Monarch RARE / VINTAGE / HARD TO GET

Elektralite LED Pro Line Pancake USER MANUAL (Version 2)

INSTRUCTION MANUAL DIGITRAC % 2 DIGITAL TENSION READOUT AND CONTROL

Bluefin Led Underwater lights.

Important Information

RK Standby Battery Operator s Manual

SECURITY DOOR CONTROLS

INSTALLATION INSTRUCTIONS FOR PART APPLICATIONS. Mazda For Models With Manual Climate Controls TOOLS REQUIRED:

Troubleshooting Title of Bulletin guide for single phase GFCIs Manual machines

FUSE PANEL. NTI-N NC(Y)/M3 NEBS Level 3 Certified NTI NCD(Y)/M3 Standard Panel with Diodes

SAFE & SECURE ACTUATOR PRODUCT MANUAL

240V UPS Typical Installation Guide

Harness the Power of the Sun

Wiring Harness Replacement Instructions - 1 Phase 2564

EStrong-series Emergency Stop

SURFACE/CEILING & SUSPENDED MOUNT INSTALLATION

TECHNICAL BULLETIN: Instructions for Upgrading to V3.3 Sun Sensors. Sun Sensor Identification:

Electric Stone Hearth Oven

TRAIL CHARGER BASED CHARGING SOLUTIONS

SEAUPS-III Uninterruptible Power Conditioning System. System Manual

MODEL B ELECTRIC HYDRAULIC PUMP

STYLE 3491 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS

PSBSH 2012B. PSBSH 13,8V/2A/7Ah/HERMETIC

Wiring Harness Replacement Instructions - 1 Phase 2565

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Transcription:

SMX Lumi-Hub SMX Lumi-Hub Installation Guide 85mm (3.35in) 70mm (2.76in) 85mm (3.35in) 70mm (2.76in) 151mm (5.94in) Lid Removed 53mm (2.09in) Tools Required Small Flat-Blade Screwdriver Large Screwdriver Long Nose Pliers 4x Mounting Screws 2-Core Power Wire 2 or 4-Core Switch Wire Components Supplied 2x Dual Entry 3x 4x M20 Gland 1x Lumi-Hub 1x Fuse Kit 1 45-0060-REV-5

Installation Instructions & Wiring Guide Before you start! Always ensure that the vessel s power source and battery are disconnected or isolated prior to installation. A qualified professional should carry out both the electrical and mechanical installation. If in doubt please contact LUMISHORE. Refer to product support section. Before you start: 1 Using suitable screws, mount the Lumi-Hub in an accessible dry location within reach of the lights and close to the vessel s power supply. 2 Select the Power cable following the cable gauge guide on page 5. Note : To reduce voltage drop along the cable, keep the power wire from the Battery to the Lumi-Hub as short as possible. 4 Use a suitable wire for the switch cable (20-24AWG), the wire should be 2-Core if using a standard On/Off switch, or a 4-Core if using the optional Lumi-Switch. Note : The switch wire does not carry any current so can be over 100ft in length. 5 Follow the guides on pages 3 to 4 to select the appropriate cable gland insert for the number of lights. The hubs can be daisy chained together if installing more than 4 lights. See page 6. Typical diagram of a 4 light install: Battery Smart-Switch On/Off Mode Lumi-Hub 2

Installation Instructions & Wiring Guide Installation instructions: 1 Mount the Lumi-Hub(s) in place. Run all cables to the Lumi-Hub. On/Off Mom Switch Connections Switch or Lumi-Switch 2 Wire the switch in acordance to the diagram on the left. Viewing from above going from left to right Red (VDC+), Green (VDC-), Blue (Mom) & Yellow (Mom). Check each wire has located correctly and has sound connection. L1 L2 3 fuses into the fuse holders. The number of fuses required will depend on the number of lights connected to the hub. If only 2 lights are connected, use only the first (being at the top) and second fuse holders. Use the fuse table on Page 8 to select the correct fuses for your product. Fuses 10-31v +VDC GND 4 Next step is to wire the hub up to the power. The power connector is located at the top left of the Lumi-Hub, where the Red (VDC+) connection is on the left and Black (GND) connection is on the right. Check each wire has located correctly and has sound connection. 3

Installation Instructions & Wiring Guide 5 Once you have carried out the previous steps it is now time to test the hub. Using your installed switch turn the power On. If eveything has been installed correctly the Lumi-Hub should power up and the fuse LED s will illuminate (depending on number of fuses installed). If none of the LED s light up, power the system Off check all connections have been located correctly and have sound connection, power system back On. If the fuse LED s remain Off please contact Lumishore. 6 Once the hub has been tested the next step is to connect the lights. With the location of the lights on the vessel in mind the lights should be connected to their respective connectors. 1 & 2 on the left, and 3 & 4 on the right. Refer to wiring card supplied with hub. Light 1 Note : between the Lumi-Hub and lights can be extended. Follow the table on pages 7 & 8 to find the maximum overall cable length. 7 Tighten all cable glands and replace lid, ensure they are sealed correctly. Light installation instructions For instructions on how to install the lights, please refer to: Lumishore Supra SMX 22-52 - 102 Installation Manual - 45-0051 Installation guides can be downloaded via our website 4

Installation Guide 2 Light Install Light 1 Power Light 2 1 & 2 3 Light Install Switch Power Light 3 Switch 4 Light Install 1 & 2 Power 3 & 4 Switch 5

Installation Guide - Continued 4+ Light Install Lumi-Hub 1 1 & 2 3 & 4 Switch & to Hub 2 Lumi-Hub 2 5 & 6 7 & 8 from Hub 1 6

Power Chart & Gauge Tables Power Chart Wiring examples; b GND a Example 1 GND Lumi-Hub Battery b Example 2 a Lumi-Hub Battery Length of cable run = Length a + Length b. 12 Volt 24 Volt Total Max Current = 20Amps (4 x SMX 152) Allowing 3% voltage drop. Total Max Current = 10Amps (4 x SMX 152) Allowing 10% voltage drop. Length of cable run (a+b) 0-10ft 12AWG 10-15ft 10AWG 15-20ft 8AWG 20-40ft 6AWG 0-20ft 16AWG Length of cable run (a+b) 20-30ft 14AWG 30-50ft 12AWG 50-100ft 10AWG 7

Extensions & Fuse Tables Light Extensions Extension example; Total Length of 6ft Extension Total length of cable = Length of light cable and extension Model SMX22 SMX52 SMX102 Gauge 16AWG 16AWG 16AWG Total Length of 12V 24V 20ft 12ft 12ft 50ft 50ft 40ft Fuse Table Model SMX22 SMX52 SMX102 Fuse Rating 12V 24V 3.0A 3.0A 4.0A 3.0A A 4.0A AWG to Metric conversion table AWG Size Cross sectional Area diameter 18 16 14 12 10 8 6 4 1mm² 1.3mm² 2.0mm² 3.3mm² 5.2mm² 8.3mm² 13mm² 20mm² 0.8mm 1.3mm 1.6mm 2.0mm 2.5mm 3.2mm 4.1mm 5.1mm 2 33mm² 6.5mm 8